01 Atomic Absorption Spectrophotometer
Model : iCE 3500
True Double Beam system.
Advanced design flame atomizer

 Wide range PMT


 Wavelength Range : 180-900 nm.
 Monochromator : High energy, silica coated, sealed optical system with self calibrating
Echelle monochromator .
 Monochromator with 1800 l/mm grating .
 Reciprocal Linear Dispersion 0.5 nm/mm at 200 nm
 Slit: Spectral band pass/ bandwidth of 0.1, 0.2, 0.5 or 1.0 nm automatically selectable.
 Accepts GFS35 or GFS35Z Graphite Furnace and Auto-sampler Modules
 Graphite Furnace TeleVision (GFTV) included for simplified method development
 Change over from flame to furnace analysis with no manual intervention .
 Detector : Wide range Photo-multiplyer .
 Lamp carousel : 6 Lamp positions each with a dedicated power supply. Accepts
single/multielement and coded/uncoded lamps.
 Background correction: Deuterium lamp background correction system modulated at
200/240 Hz,
 Guaranteed background correction for up to 2 Abs of background with maximum error
of 2%.
 GUARANTEED Quadline background correction.
Sample Nebulizer: An inert fluoroplastic spray chamber incorporating an externally adjustable
inert impact bead and flow spoiler.
• Auto burner height optimization and fully inert spray chamber.
• The nebulizer is inert and has a Pt/Ir capillary and PTFE venture as standard and this is
oprimized in the factory .
•Burner : Universal Finned Titanium 50 mm burner suitable for air/acetylene and nitrous
oxide/acetylene flame types supplied as standard .
•An inert over-pressure membrane is housed in the rear of the spray chamber for maximum
operator safety.
Gas Control: Automatic gas system using binary flow control and programmable array state
logic for reliability
•Safety: Full safety interlocks, including pressure sensors on both lines, power failure protection,
burner interlock and flame sensor
•Fuel and oxidant flow rates software controllable
•Automatic flame ignition.
•One spray chamber configuration and burner for all gas mixtures and sample types
•Automatic flame optimization

SOLAAR software supplied as standard


• Operating AA software supplied as standard
• Compatible with Windows 2000, XP Professional and VISTA Ultimate
• Wizard based interface
• Context sensitive help
• Automatic programming of up to 16 elements
• Instrument is operated through an appropriate data station computer.
• Facility to record lamp usage
• Capable of automatically switching lamps on and off in an intelligent manner to preserve
lamp life but also ensure lamps are warmed up sufficiently at time of use
• Normal, standard addition and standard curve calibration methods supported
• Flexible and comprehensive results database filters to select and display the required data
Flat No: B1, House No : 119, Block : F, Banani, Dhaka –1213, Bangladesh
Tel : 8852557, Fax: 8857842, Email : aranir@bangla.net / invent@bangla.net
• Export of data to other applications is possible.
• Integrated Quality Control protocols
• Language options.

• CookBook: Complete user help facility to provide a comprehensive AA Cookbook for all
elements. The cook book contains sample preparation principles and method of analysis of
different elements fo sample like soil , sludge, sediment, drinking and waste water , oil , fuel ,
food , poultry and other feeds for both Flame and GF Analysis .It also includes procedure
required for Vapor Hydride analysis .

• QC Protocols: Ten Quality Control tests for flame and vapor and furnace , QC Blank,
QC Standard, QC Spike, Matrix Spike, Lab Control Sample, Duplicate, Precision (replicate
%RSD), Correlation Coefficient and Detection Limit tests. – To be complied.
Cadmium Data Coded Hollow Cathode Lamp

Magnesium Data Coded Hollow Cathode Lamp

Zinc Data Coded Hollow Cathode Lamp

Cobalt Data Coded Hollow Cathode Lamp

Copper Data Coded Hollow Cathode Lamp


Iron Data Coded Hollow Cathode Lamp
Manganese Data Coded Hollow Cathode Lamp
Molybdenum Data Coded Hollow Cathode Lamp
Lead Data Coded Hollow Cathode Lamp
Cadmium Data Coded Hollow Cathode Lamp
Chromium Data Coded Hollow Cathode Lamp

Hydride Generation System:


Vapour Generation System with accessories

VP100 Continuous Flow Vapour Generation System for Flame Heating Hydride generation
system
[ Air/acetylene flame system ] .

 For the determination of the hydride forming elements giving improved sensitivity and
reduced interferences when compared with conventional flame analysis.
 Employs the continuous flow principle for high precision and self-cleaning after each
sample.
 The system is fully automatic and controlled by the data station and SOLAAR
software.
 Suitable for 220/240V and 110/120V operation.
Specifications:
 Absorption Cell: Open ended T-shaped quartz cell, 120mm long, 8mm internal
diameter
 Cell heating: Air/acetylene flame on 50mm burner
 Gas purge: Argon or nitrogen
 Inlet pressure: 0.35 bar (5 lb/in2)
 Consumption rate: Up to 600 ml/min
 Reducing agents: Normally sodium borohydride but tin II chloride may be used for
mercury analysis
 Solution transport: Peristaltic pump, 2 channels, using contiuous flow principle
 Flow rates: Reductant channel: 3.2ml/min Sample channel: 7.8ml/min
Flat No: B1, House No : 119, Block : F, Banani, Dhaka –1213, Bangladesh
Tel : 8852557, Fax: 8857842, Email : aranir@bangla.net / invent@bangla.net
 Flow selection: By inert valve
 Reagent bottles: One litre square plastic bottles

Spare Silica [ Quartz] T Cells for Hydirde generation system , 2 pcs per pack . 5
LH Universal Accessory Mount 1
Acetylene Gas Pressure Regulator 01
Nitrous Oxide Gas Pressure Regulator 01
Acetylene Flashback Arrestor - Highly Recommended 01
Argon Gas Pressure Regulator 01

Local Items to be purchased in Locally against the following value :

Accessories : ( Local )
SL# Item
1 10 KVA UPS
2 •Acetylene Gas Cylinder 47 Lit
3 • Nitrous Oxide Gas Cylinder 47 Lit
4 • Argon Gas Cylinder 47 Lit
5 • Desktop Computer with Printer as per tender spec
6 • Stainless Steel Hood

Flat No: B1, House No : 119, Block : F, Banani, Dhaka –1213, Bangladesh