M a x i m u m P r e s s u r e.

High Pressure Technology • Testing Equipment


Hydraulics • Pneumatics

Technical Data Sheet G400-2 (L)-5U » Oil service !

G400-2 (L) VE » Water service

Technical Data:
Air drive pressure: 1-10 bar / 14,5 - 145psi
Maximum outlet pressure (oil service): 5,500 bar/ 79,750 psi
Maximum outlet pressure (water service): 4,000 bar/ 58,000 psi
Pressure ratio: 1:796
Displacement volume/double stroke 2.5 cm³/ 0.15 cu.inch
Connections:

Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G400-2 • Page 1 of 3 • DB.01.01.12.09


Inlet: Standard: bottom inlet 1/4 BSP
Outlet 5,500 bar/ 79,750 psi: 5U (5/8-18UNF) oil service
Outlet 4,000 bar/ 58,000 psi: 4H (9/16-18 UNF) water service
G400-2 (L)S-5U
single acting, double air drive head
Air drive: 3/4 BSP
Maximum operating tempreature: 60°C
Net weight: 22.0 kg
Pressure and flow performances, please see enclosed graph.

Wetted materials of construction: Seal package: G400-2(L): Polyurethan, NBR


G400-2(L)VE: UHMWPE, FKM
Pump Body: Stainless Steel
Piston: carbide metal
Fittings: 17-4PH
Approximate Dimensions: Height / Depth / Width: 483 mm / 211 mm / 272 mm

Available Options: Outlet pressure 5,500 bar/ 79,750 psi (oil): G400-2 (L)S-5U (5/8-18 UNF)
Seal material for oil service: G400-2 (L)
Seal material for water service: G400-2(L)VE
Side inlet: G400-2(L)S/ G400-2(L)VES
Special inlet and outlet ports, i.e. NPT: G400-2(L)-NPT / G400-2(L)VE-NPT
Special seal material to handle special fluids on request.

Available Accessories:

Air control units with filter pressure regulator, control pressure gauge and shut off valve: G400-2(L) with C2
To protect the pump against excessive outlet pressures or to limit the outlet pressure, a safety G400-2(L) with C2/SVair (The
valve can be fitted to the air control unit in the air drive line: required outlet pressure has to be
indicated.)

! For operating pressures above 4,000 bar (58,000 psi) common hydraulic fluids can’t be used. We recommend the use of
Maxifluid (Item Code: 1090.0270) which will remain in the liquid phase at pressure levels.

Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including limitations
of our liability, apply to all products and services sold.

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics

Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G400-2 • Page 2 of 3 • DB.01.01.12.09

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de
Leistungsdiagramm/Performance Graph G 400 -2L
Prüfflüssigkeit/Test Liquid: Wasser-Öl-Emulsion/Water Oil Emulsion ca. 1 - 10 cst
7000 3500

8 bar PBmax./Max.outlet pressure 5500 bar


6000 8 bar 3000
Hydraulics • Pneumatics

5000 2500
6 bar
6 bar
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment

4000 2000

4 bar
3000 4 bar 1500

Betriebsdruck/
Luftverbrauch/

Outlet Pressure (bar)


Air consumption (lN/min)

2000 1000

1000 500

0 0

0
5
0
5
0
5
0
5
0

0, 0
0, 0
0, 1
0, 1
0, 2
0, 2
0, 3
0, 3
0, 4

Förderleistung/Flow (l/min)
Betriebsdruck bei/Outlet Pressure at 4 bar Betriebsdruck bei/Outlet Pressure at 6 bar
Betriebsdruck bei/Outlet Pressure at 8 bar Luftverbrauch bei/Air consumption at 4 bar
Luftverbrauch bei/Air consumption at 6 bar Luftverbrauch bei/Air consumption at 8 bar

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de
Release 12 / 2019 • MAXIMATOR • Technical Data Sheet G400-2 • Page 3 of 3 • DB.01.01.12.09

You might also like