Design Calculation For 9 MM Fibrous Plaster Ceiling
Design Calculation For 9 MM Fibrous Plaster Ceiling
Design Calculation For 9 MM Fibrous Plaster Ceiling
Design limitation
1) Ceiling batten dimension
a) 32.0 mm x 12 mm x 0.35 bmt ceiling batten
2) 9.0 mm thick Fibrous Plasterboard, weight considered = 7.00 kg/m2
3) Ceiling batten frame design to carry it self-weight = 2.0 kg/m2
4) Total Dead Load, DL = 9.00 kg/m2 = 0.09 kPa
5) No internal pressure considered in the design calculation
6) Maximum allowable services loading = 0.05 kPa
7) Strength Check , 1.4 G + 1.7 U(In accordance to AS 2785)
8) Deflection Limit: L/360 & shall not be greater than 12mm under services
loading 1.0 G +1.0 U
9) Ceiling Suspension 32 mm x 12 mm x 0.35 bmt @ 900 mm
10) Primary Section 32 mm x 12 mm x 0.35 bmt @ 900 mm
11) Secondary Section 32mm x 12 mm x 0.35bmt @ 406 mm
12) Ceiling Drop Considered = 2000 mm
1|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Design Calculation
for CB3212 - 9 mm Fibrous Plaster Ceiling.docx
R1 R2 R3
L L
Section Properties
Profile : TECHNO
U-Metal32
32mm
mm xx 12
12 mm
mmxx0.35
0.35bmt
bmtCeiling
CeilingBatten
batten
I xx : 3.25E-09 m4
Analysis Input
Total Length : 3.6 m
L: 0.9 m
Loading and Spacing Section Analysis
Spacing = 0.9 m R1 = R3 = 0.0483 kN
2
Pressure, U = 0.03 kN/m R2 = 0.16099 kN
U= 0.027 kN/m V 1 = V max = 0.08049 kN
Design Factor = 1.7 M1 = 0.01449 kNm
weight = 0.09 kN/m2 M2 = 0.00815 kNm
G= 0.081 kN/m d= 0.58926 mm
Design Factor = 1.2 < 2.5, L/1527.34 >L/360; Satisfatory
Total Factored Load = 0.1431 kN/m
Total Unfactored Load = 0.108 kN/m
2|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
3|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Design Capacities
5.651 kN = ØNty (Ø = 0.90)
5.4438 kN = ØNtu (Ø = 0.90)
0.051294 kNm = ØMsx+ (Ø = 0.95)
0.051294 kNm = ØMsx- (Ø = 0.95)
0.011736 kNm = ØMsy+ (Ø = 0.90)
0.011766 kNm = ØMsy- (Ø = 0.95)
0.019909 kNm = ØMbx+ (Ø = 0.90)
0.019909 kNm = ØMbx- (Ø = 0.90)
0.009581 kNm = ØMby+ (Ø = 0.90)
0.011766 kNm = ØMby- (Ø = 0.90)
0.059996 kNm = ØMsfx+ (Ø = 0.95)
0.059996 kNm = ØMsfx- (Ø = 0.95)
0.031213 kNm = ØMsfy+ (Ø = 0.90)
0.012388 kNm = ØMsfy- (Ø = 0.95)
1.3427 kN = ØVvx (Ø = 0.90)
1.1992 kN = ØVvy (Ø = 0.90)
[ - ] kN = ØRbx (Ø = 0.85)
0.45198 kN = ØRby (Ø = 0.85)
3.2566 kN = ØNs (Ø = 0.85)
0.71723 kN = ØNcft (Ø = 0.85)
3.0528 kN = ØNcd (Ø = 0.85)
0.045264 kNm = ØMbdx+ (Ø = 0.90)
0.045264 kNm = ØMbdx- (Ø = 0.90)
0.0094774 kNm = ØMbdy+ (Ø = 0.90)
[ - ] kNm = ØMbdy- (Ø = 0.90)
Cross-Sectional Dimensions
0.00035 m = Thickness (t)
0.032 m = Overall depth (D)
4|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Miscellaneous Parameters
3.9831E005 kPa = fox, Elastic buckling stress for buckling about principal x-axis
45976 kPa = foy, Elastic buckling stress for buckling about principal y-axis
95278 kPa = foz, Elastic buckling stress for torsional buckling about z-axis
45976 kPa = foc, Elastic buckling stress
40321 kPa = fn, Inelastic buckling stress
8.3364 kN = Nox, Elastic flexural buckling load about x-axis (used for moment amplification)
0.96225 kN = Noy, Elastic flexural buckling load about y-axis (used for moment amplification)
0.022122 kNm = Mox+, Elastic lateral buckling moment for positive bending about x-axis
0.022122 kNm = Mox-, Elastic lateral buckling moment for negative bending about x-axis
0.013694 kNm = Moy+, Elastic lateral buckling moment for positive bending about y-axis
0.3096 kNm = Moy-, Elastic lateral buckling moment for negative bending about y-axis
-7.8297E-005 m = x-ordinate of C(full)->C(effective) (fy)
0 m = y-ordinate of C(full)->C(effective) (fy)
3.8151E-007 m = x-ordinate of C(full)->C(effective) (fn)
0 m = y-ordinate of C(full)->C(effective) (fn)
[ - ] m4 = Ie_Mx*, Effective second moment of area for design Mx*
5|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
R1 R2 R3
L L
Section Properties
Profile : TECHNO 32 mm
U-Metal x 12xmm
32 mm 12 xmm
0.35xbmt
0.35Ceiling batten Batten
bmt Ceiling
I yy : 3.75E-10 m4
Analysis Input
Total Length : 3.6 m
L: 0.9 m
Loading and Spacing Section Analysis
Spacing = 0.406 m R1 = R3 = 0.02179 kN
2
Pressure, U = 0.03 kN/m R2 = 0.07262 kN
U = 0.01218 kN/m V 1 = V max = 0.03631 kN
Design Factor = 1.7 M1 = 0.00654 kNm
2
weight = 0.09 kN/m M2 = 0.00368 kNm
G = 0.03654 kN/m d= 2.3038 mm
Design Factor = 1.2 < 2.5, L/390.66 >L/360; Satisfatory
Total Factored Load = 0.06455 kN/m
Total Unfactored Load = 0.04872 kN/m
6|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
7|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
8|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Miscellaneous Parameters
3.9831E005 kPa = fox, Elastic buckling stress for buckling about principal x-axis
45976 kPa = foy, Elastic buckling stress for buckling about principal y-axis
3.4268E005 kPa = foz, Elastic buckling stress for torsional buckling about z-axis
45976 kPa = foc, Elastic buckling stress
40321 kPa = fn, Inelastic buckling stress
8.3364 kN = Nox, Elastic flexural buckling load about x-axis (used for moment amplification)
0.96225 kN = Noy, Elastic flexural buckling load about y-axis (used for moment amplification)
0.041953 kNm = Mox+, Elastic lateral buckling moment for positive bending about x-axis
0.041953 kNm = Mox-, Elastic lateral buckling moment for negative bending about x-axis
0.04476 kNm = Moy+, Elastic lateral buckling moment for positive bending about y-axis
0.34067 kNm = Moy-, Elastic lateral buckling moment for negative bending about y-axis
-7.8297E-005 m = x-ordinate of C(full)->C(effective) (fy)
0 m = y-ordinate of C(full)->C(effective) (fy)
3.8151E-007 m = x-ordinate of C(full)->C(effective) (fn)
0 m = y-ordinate of C(full)->C(effective) (fn)
[ - ] m4 = Ie_Mx*, Effective second moment of area for design Mx*
9|Page
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Units
-----
Length: Metres
Force: KiloNewtons
Mass: Kilograms
Input Parameters
----------------
- Member and section capacity checks conducted.
- Design actions come first-order elastic structural analysis.
- Thin-walled theory is used for calculation of cross-section properties.
- Square corners are used for calculation of torsional section properties.
- Shear centre and warping constant are calculated on-the-fly.
- Princpial (x-y) axes are used.
10 | P a g e
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
11 | P a g e
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Design Capacities
-----------------
5.5092 kN = ØNty (Ø = 0.90)
5.3072 kN = ØNtu (Ø = 0.90)
0.049974 kNm = ØMsx+ (Ø = 0.95)
0.049974 kNm = ØMsx- (Ø = 0.95)
0.010963 kNm = ØMsy+ (Ø = 0.90)
0.011026 kNm = ØMsy- (Ø = 0.95)
0.0037903 kNm = ØMbx+ (Ø = 0.90)
0.0037903 kNm = ØMbx- (Ø = 0.90)
0.0024968 kNm = ØMby+ (Ø = 0.90)
0.011026 kNm = ØMby- (Ø = 0.90)
0.057219 kNm = ØMsfx+ (Ø = 0.95)
0.057219 kNm = ØMsfx- (Ø = 0.95)
0.029363 kNm = ØMsfy+ (Ø = 0.90)
0.011572 kNm = ØMsfy- (Ø = 0.95)
1.2822 kN = ØVvx (Ø = 0.90)
1.2188 kN = ØVvy (Ø = 0.90)
[ - ] kN = ØRbx (Ø = 0.85)
0.45282 kN = ØRby (Ø = 0.85)
3.2559 kN = ØNs (Ø = 0.85)
0.13051 kN = ØNcft (Ø = 0.85)
3.0786 kN = ØNcd (Ø = 0.85)
0.04421 kNm = ØMbdx+ (Ø = 0.90)
0.04421 kNm = ØMbdx- (Ø = 0.90)
0.0089927 kNm = ØMbdy+ (Ø = 0.90)
[ - ] kNm = ØMbdy- (Ø = 0.90)
Cross-Sectional Dimensions
--------------------------
0.00035 m = Thickness (t)
0.032 m = Overall depth (D)
0.012 m = Overall flange width (B)
0.0023 m = Stiffener length (L)
0.00035 m = Internal corner radius (R)
12 | P a g e
Design Calculation for 9 mm Fibrous Plaster Ceiling with CB3212 Ceiling Frame
Miscellaneous Parameters
------------------------
77689 kPa = fox, Elastic buckling stress for buckling about principal x-axis
8580.4 kPa = foy, Elastic buckling stress for buckling about principal y-axis
20560 kPa = foz, Elastic buckling stress for torsional buckling about z-axis
8580.4 kPa = foc, Elastic buckling stress
7525 kPa = fn, Inelastic buckling stress
1.5852 kN = Nox, Elastic flexural buckling load about x-axis (used for moment amplification)
0.17508 kN = Noy, Elastic flexural buckling load about y-axis (used for moment amplification)
0.0042115 kNm = Mox+, Elastic lateral buckling moment for positive bending about x-axis
0.0042115 kNm = Mox-, Elastic lateral buckling moment for negative bending about x-axis
0.0027742 kNm = Moy+, Elastic lateral buckling moment for positive bending about y-axis
0.057887 kNm = Moy-, Elastic lateral buckling moment for negative bending about y-axis
5.7697E-005 m = x-ordinate of C(full)->C(effective) (fy)
0 m = y-ordinate of C(full)->C(effective) (fy)
0 m = x-ordinate of C(full)->C(effective) (fn)
0 m = y-ordinate of C(full)->C(effective) (fn)
[ - ] m4 = Ie_Mx*, Effective second moment of area for design Mx*
[ - ] m3 = Ze_Mx*, Effective section modulus for design Mx*
[ - ] m4 = Ie_My*, Effective second moment of area for design My*
[ - ] m3 = Ze_My*, Effective section modulus for design My*
1.8368E005 kPa = fodc, Distortional buckling stress in pure compression
3.4039E005 kPa = fodx+, Distortional buckling stress in bending
3.4039E005 kPa = fodx-, Distortional buckling stress in bending
4.1731E005 kPa = fody+, Distortional buckling stress in bending
[ - ] kPa = fody-, Distortional buckling stress in bending
-End-
13 | P a g e