EcoFIT PACiS OI TM

To give a new life to your installations


PACiS OI
V3.x up to V4.6
< PACiS EcoSUI ● Original brand: AREVA or older
● System HMI type: PACiS OI

A true extended life time, with more facilities


Without EcoFIT
PACiS OI End of Windows 2000, End of Microsoft®
Commercialisation XP commercialisation support for Windows XP

2003 2005 < 2014

With EcoFIT
Improve the performance of your Control System with the latest technology in computers.
Benefit from Computer and OS upgrading to Windows 7 to get enhanced performances and advanced features
for the new HMI.
PACiS Hardware & OS upgrade solution
Commercialisation With enhanced HMI performances

2013

2003 2012 with EcoFIT <


<

Ongoing

Main characteristics and performances


Without EcoFIT With EcoFIT

PACiS with OI HMI (V3.x to V4.6) PACiS with EcoSUI HMI

Windows 2000 or XP Windows 7 (32/64bits)


Windows server 2008 64bits
One Ethernet network management Multiple IEC61850 client access points
Multi-LAN through IEC/IEC Gateways
Configuration & database generation using SCE Direct IEC61850 configuration by import of SCD file

Off-line modification & Time delayed deployment of Immediate deployment of database modification
database after recompilation
Redundancy switch over within 1 mn Hot redundancy seamless switchover
Maximum handled dataflow 100 Measured Values Handled dataflow up to 3000 MV
archived /sec / server archived /sec /server
EcoFIT PACiS OI TM

EcoFIT PACiS OI Secure configuration, ready for future extensions


New software organisation ● Automatic conversion of PACiS OI configuration
● Configurable by direct import of SCD files
● Promotes incremental addition of IED without disturbing existing
database

Enhanced acquisition properties


● Scalable: multiple simultaneous instances of IEC61850 client
applications
● SNMP V2/V3 management
● OPC DA2 client

Enhanced graphical features


● Built-In bus bar color animation
● Realtime trends of analog values as tooltip
● ZoomIn / ZoomOut
● On line circuit name configuration
● Flash animation integration,
● Monitoring facilities by color bar graph status easy implementation
Typical HMI graphical view Maintenance, Commissioning, Post Fault analysis facilities
● Open alarm grouping functionnality
● Data & curves reporting with export option in generic format
(CSV, PDF)
● VCR (recorder & replay): possibility to replay any substation
sequence of events
● SOE and alarm lists with tree viewer and freeze options
● Application localization with language hot swapping
(not limited to 2 languages)
● Web browser

Typical HMI migration steps What are the Benefits ?


 No impact on existing Ethernet Network, Bay controlers,
Customer site Schneider Electric site Gateways & IEDs, as well as electrical drawings or
Process wiring
PACiS V4.6 HMI

<  Fast implementing without substation shut down


Migration to
PACiS HMI

if V3.x
 Secure Migration managed by the manufacturer
©2013 - Schneider Electric Industries SAS - All rights reserved

 Cost effective solution providing Advanced graphical


if V
4. interface features, enhanced performances
x
 Easiness for future extentions
<

<
Migration to
EcoSUI HMI

Schneider Electric Industries SAS


35, rue Joseph Monier As standards, specifications and designs change from time to time, please ask for confirmation
CS 30323 of the information given in this publication.
F-92505 Rueil-Malmaison cedex (France)
Tel.: +33(0)1 41 29 70 00 This document has been
RCS Nanterre 954 503 439 printed on ecological paper.
Capital social 896 313 776 €
www.schneider-electric.com Publishing: Schneider Electric.
Photos: Schneider Electric
NRJED313543EN
04/2013

You might also like