Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ecosui: Simple and User-Friendly Iec 61850 Based Substation Hmi

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

01

Graphical user interface

EcoSUI
Simple and user-friendly IEC 61850 based Substation HMI

EcoSUI offers a simple, intuitive, modern and


customizable interface dedicated to electrical
substations supervision.
EcoSUI software is based on the IEC 61850
standard data model for its design, configuration
and communication within the substation.
EcoSUI complies with IEC 61850 top-down
engineering process with import of IEC 61850-6
SCL files such as SSD, SCD and/or CID.
EcoSUI can therefore evolve in a multi-vendor
system context.
EcoSUI is the cornerstone HMI technology for
the retrofit of legacy systems in the associated
ECOFIT™ solutions offer.

PACiS OI V3/V4
CUSTOMER BENEFITS
 Flexible and scalable system


PSCN3020 HMI
SeeFox HMI
< EcoSUI
architectures
 MiCOM S10 HMI
 Complies with IEC 61850

 Efficient engineering

 Contributes to deploy interoperable


cyber secure solutions

 Cost effective legacy PACiS OI and EcoSUI contributes to deploy


PSCN3020 modernization solutions applicable cyber-security
 Attractive user experience international standard solutions.
02
Graphical user interface EcoSUI

Technical datasheet
Software capabilities Data acquisition and data management
 Hot redundancy of I/O server  Multiple LAN connections
 Distributed, multiple server architectures  IEC61850-8-1 Edition 1 client
 Web access  Modbus TCP/IP Client
 Multi-protocol acquisition  EFIP Client
 Dataflow: up to 3000 stored data/second  SNMP V2/V3 Client
 Virtual data creation by formulas
Configuration tools
 Legacy systems database migration tools Real time control and monitoring
 Graphical editor supporting SVG  Single Line Diagram animation with unambiguous identification of
(Scalable Vector Graphics) format devices
 Objects and templates libraries  Busbar automatic coloring
 IEC61850-6 SCL files import  Select Before Operate and Direct Execute control sequences

Operating Systems Alarms and events management


 Windows 7 Professional 32/64 bits  Alarms and events lists with 1ms time-stamped data
 Windows 7 Ultimate 32/64 bits  Alarm audibility on klaxon or buzzer
 Windows Server 2008 R2 64 bits  Alarm grouping
 Up to 5 levels of alarms severity
Cyber-security
 Tree viewer to navigate in electric topology
 Role-Based Access Control
 Active Directory synchronization Analysis facilities
 System security logs recording  Measurement real time trend curves in dedicated view or as tooltip
 Malware prevention by anti-virus or  Data & curves reporting with export option in generic format
whitelisting (CSV, PDF)
 OS and application hardening  Disturbance file extraction, storage and visualization via
 Compliance: MiCOM S1 Studio integrated viewer.
NERC-CIP,  Record and replay a sequence of events (VCR)
IEC62351,
WIB, Specific functions
BDEW,  Historian based on mySQL with optional licensed support.
 Configurable depth, purge and backup
IEEE1686
 Supports Python scripting
 On-line graphical modifications
 Zooming: ZoomIn / ZoomOut and screen resizing for
Laptop adaptation
 Localization: supports multiple languages with possibility of
language hot swapping, not limited to 2 languages
© 2014 Schneider Electric - All rights reserved

Schneider Electric
35, rue Joseph Monier As standards, specifications and designs change from time
CS 30323 to time, please ask for confirmation of the information given
F - 92506 Rueil Malmaison Cedex (France) in this publication.
Tel.: +33 (0) 1 41 29 70 00
RCS Nanterre 954 503 439 Design: Schneider Electric
Capital social 928 298 512 € Photos: Schneider Electric and © iStockphoto This document has been
www.schneider-electric.com Printed: printed on recycled paper.

NRJED314600EN 12-2014