ATA 71: 1.features of PW1100G-JM Engine Are
ATA 71: 1.features of PW1100G-JM Engine Are
ATA 71: 1.features of PW1100G-JM Engine Are
2.“PW1130G-JM” means:
A. Engine is rated at max thrust of 25300 lbs to install in the Airbus A/C
B. Engine is rated at max thrust of 30000 lbs to install in the Airbus A/C
C. Engine is rated at max thrust of 25000 lbs to install in the Airbus A/C
4. Fan cowls:
A. Each of the 3 fan cowl door latches has a fan cowl door proximity sensor which is able to
detect weather the relative latch is locked to alert the ground crew to the fan cowl’s
position
B. Fan cowl door has two fan cowl door proximity sensors which are able to detect weather
the relative latch is locked to alert the ground crew to the fan cowl’s position
C. Fan cowl door has a fan cowl door proximity sensor which is able to detect weather the
relative latch is locked to alert the ground crew to the fan cowl’s position
ATA 72:
{ATA71}
1.How many percent of fuel saving between A321Neo and A321Ceo? =
(10-12%)
(17-18%*)
(20-22%) {ATA71}
2. What is the Significant improvement on Engine PW1100G? =
(LOW NOISE, FAN DRIVE GEAR SYSTEM, THERMAL EFFICIENCY*)
(LOW NOISE, FAN DRIVE GEAR SYSTEM,)
(FAN DRIVE GEAR SYSTEM, THERMAL EFFICIENCY)
3. What technology used to make compressor blades on Engine PW1100G? =
(Ingrate bladed rotor*)
(welding blade and shaft)
(Casting)
4. What is the ratio of the bypass Ratio on PW1100G =
(12:1*)
(5:1)
(7:1)
5. How many latches on fan cowl door lock system? =
(1)
(2)
(3*)
6. How many are Hold open rod on fan cowl door? =
(Forward telescopic type hold-open rod and the aft fixed-length type rod*)
(02 telescopic type hold-open rod)
(01 Forward telescopic type hold-open rod)
7. How many fan cowl strakes in one engine? =
(01 on outboard engine)
(02 on bothside engine*)
(01 on inboard engine)
8. How many proximities sensor on fan cowl door? =
(1)
(2)
(3*)
9. Which port of Drain Mast has “no leak” permit? =
(IDG)
(FDGS)
(2.5 Bleed valve*)
{ATA 72 - ENGINE CONSTRUCTION}
1. What is the rotation of each shaft in PW1100G when look backward =
(Fan - Counter CW, N1 - CW, N2 -CW)
(Fan - CW, N1 - counter CW, N2 - CW*)
(Fan - Counter CW, N1 - CW, N2 - counter CW)
{ATA 74 - IGNITION}
Where is the Exciter installed in? =
(Core Area)
(Fan Area*)
(Do not install Exciter on PW1100G)
Exciter is cooling by... =
(Outside Air*)
(Bleed Air from stage 2.5)
(Discharge air from stage 2.5)
{ATA 75 - AIR}
1. How many start bleed valve on PW1100G? =
(2)
(3*)
(4)
2. Which stage the start bleed valve install on? =
(6th*)
(7th)
(8th)
3. What is 5 major function of air system on PW1100G?
1. increase engine operability and stability,
2. reduce noise from engine
3. cool engine parts
4. improve fuel effiency,
5. remove ingested debris from the airstream.
6. supply bleed air for ESC
7. pressurize and seal bearing compartments, =
(1, 2, 3, 4, 5)
(1, 3, 4, 5, 7*)
(1, 3, 4, 6, 7)
5. What is the fail safe postion of 2.5 Bleed valve actuator? =
(Fully Close)
(Fully open*)
(30% open)
6. The HPC Stator Vane Actuator can control how many stage of HPC? =
(2)
(3*)
(4)
7. What is the purpose of Buffer air heat exchanger? =
(Provides discrete (on/off) control of HPC 3rd Stage bleed air supply to the Bearing Ventilation
System.)
(Use station 2.5 bleed air to cool HPC 3rd Stage Air before its delivery to the No4 Bearing
housing.*)
(Provide cooling buffer air to the engine main bearing compartment and prevent oil leakage)
8. What is the purpose of LPBSOV - Low pressure buffer shutoff valve? =
(Provides discrete (on/off) control of HPC 3rd Stage servo pressure sent to the LPBSOV)
(Direct buffer air to the Bearing Ventilation System)
(Provides discrete (on/off) control of HPC 3rd Stage bleed air supply to the Bearing Ventilation
System.*)
{ATA 78 - REVERSER}
1. What is the type of Reversere? =
(Translating Sleeve*)
(Blocker door)
2. How many Hold Open Rod on each Reverser half? =
(1*)
(2)
(3)
3. How many blocker door on each reverser half? =
(5*)
(6)
(4)
4. How many latches are used to fully closed reversers? =
(7*)
(5)
(6)
5. Where is HCU Inhibit Lever located in? =
(On HCU)
(On RH fancase)
(On LH Fancase*)
6. How many locking actuator installed in 1 engine? =
(1 on LH Reverser only)
(2*)
(1 on RH Reverser only)
7. How many locking feedback actuator install in 1 engine? =
(1 on RH side only)
(2*)
(1 on LH side only)
1. What is the type of bearing in FDGS?- =
(Journal Bearing*)
(Tapered roller bearing)
(Oil firm Bearing)
2. How many warning level can main oil filter triggered? =
(None)
(Clogged)
(Degraged and Cloggged*)
3. Which computer control JOSV? =
(EEC)
(EIU)
(No computer, only mechanical.*)
4. Which computer control VORV? =
(No computer, only mechanical.)
(EEC*)
(EIU)
5. What is the Fail Safe postion of VORV? =
(Fully Open*)
(Fully Close)
(30% open)
6. How many pump inside the Journal Bearing? =
(0)
(1)
(2*)
7. What is the new component on Oil Monitoring system compare to V2500? =
(Master Magnetic Chip Detector)
(Oil Debris Monitoring*)
(Last Chance Strainer)
8. What is the pressure maintain on oil tank assembly by Deaerator? =
(8 psi)
(12 psi*)
(20 psi)
9. Which side of engine where most of oil system component installed in? =
(LH side*)
(RH side)
(Both side)
10. How many pump stage on LSOP? =
(1 supply pump and 6 scavenge pumps*)
(2 supply pumps and 5 scavenge pumps)
(1 supply pump and 5 scavenge pumps)
1. What is the different in starting sequence of PW1100G with V2500? =
(Cooling time (auto drycranking)*)
(Ignition sequence)
(High pressure bleed air)
3. How can we manual open Start valve? =
(By an access door in RH fan cowl)
(By an access door in LH Reverser)
(By an access door in RH Reverser*)
4. Start valve control by =
(Torque motor)
(Solenoid*)
(LVDT)
5. Air Starter used oil for cooling and lubricating from… ? =
(Starter lubricating system)
(Engine Lubricating system*)
(IDG lubricating system)
6. What is fail safe postion of Starter Valve? =
(Fully closed*)
(Do not have fail safe position)
(Partition open)