Page No. : 4
Inspection & Test Plan Document. No. : 8015-0151-00-AL-CD 1133/19-GF-OGF4-J-
VD-9503-00001
Rev. No. / Date :00 / 05/02/2020
H : Mandatory Hold Point, The Supplier cannot carry out the specified controls and tests without Inspector attendance.
Description : W : Witness Point, The manufacturer shall notify the client and TPI Inspector, but there is no hold on the production.
LP - GV IC
SW : Spot Witness, Vendor may proceed with the work with agreement of the Contractor and/or the Employer
Monolithic Insulating Joints
18" R : Review Point, Review document, which includes the review of quality control records, test reports, etc.
-
2 Inspection Test Plan Test to be carry out & Delivery 100% As per delivery Date H R R ITP-519-19
ASTM D709 G10 and minimum Material Data sheets equivalent to EN Sub-Supplier Data
6 Acceptance of insulating material Check of Material Certification 100% H R R
Hardness 75 Shore D 10204 2.2 level Sheet
GF-OGF4-P-SP-1003
NDE on all machined Forgings and ASME V Art. 7 & 25 ASME VIII Div.1 App.6
8 NDE H R R MT REPORT
Pipes (MPI) 8015-0151-00-AL-CD 1133/19-GF- Absence of defects
OGF4-J-VD-9508-00001
GF-OGF4-P-SP-1003
R
Radiographic Examination On Butt ASME V Art. 2 & 22 8015-
11 NDE ASME VIII Div.1 UW51 H (RT films R RT REPORT
Welds N° [W1] & [W2] 0151-00-AL-CD 1133/19-GF-OGF4-J-
review)
VD-9506-00001
8015-0151-00-AL-CD 1133/19-GF-
12 Assembling Insulating Joints Assembling Insulating Joints Conformity to DWG 519/19 H / /
OGF4-J-VD-9502-00001
GF-OGF4-P-SP-1003
ASME V Art. 7 & 25 ASME VIII Div.1 App.6
14 NDE MT On Closure Welds N°[F] H R R MT REPORT
8015-0151-00-AL-CD 1133/19-GF- Absence of defects
OGF4-J-VD-9508-00001
19 NDE
GF-OGF4-P-SP-1003 and ASME V
Art. 7 & 25 No lamination cracks, no
MT On final bevels 100% H R R MT REPORT
8015-0151-00-AL-CD 1133/19-GF- discontinuities
OGF4-J-VD-9508-00001
2 joint (1st
Immersion Test before Electrical produced GF-OGF4-P-SP-1003
Check: and 1 8015-0151-00-AL-CD 1133/19-GF- R≥5MOhm @ 1000V DC H R R EI REPORT
12h immersion in 3% NaCl solution selected by OGF4-J-VD-9509-00001
PCIHBV)