SLAB BEAM Model - RAKESH
SLAB BEAM Model - RAKESH
SLAB BEAM Model - RAKESH
SB1
SB2 GENERAL NOTES
SBR4
17'-11"
SBR4
SBR3
SB4
SB4
TWO WAY SLAB
18'-3"x 11'-0" SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
8# @ 6"C/C DIST. BAR
SB6 SB2
2'-2" 4'-4" 6'-8" 3'-3" SB3 SBR3
SB5
SB6
HB 3'-1" 5'-4"
5'-6"
5'-6"
5'-6"
11" SUNK 8'-2" 4'-5"
SB5
B B
3'-10"
3'-10"
3'-10"
HB
ONE WAY SLAB
TOILET DRESS SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
P A S S A G E
14'-6"
DOWN SB1
WASH
4'-5"x 14'-10"
10'
6'
SB1
SB1
SB3
SB4
W I D E
KITCHEN
MLB
C3 C3
TWO WAY SLAB
15'-4"
15'-4"
15'-4"
14'-6"x 10'-0" ONE WAY SLAB
SLAB THICK. 5"
LOBBY 6'
SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
LIFT 10# @ 6"C/C MAIN BAR
8# @ 6"C/C DIST. BAR
8# @ 6"C/C DIST. BAR
6'-1"x 15'-4" NOTES : -
6'-0"x 6'-0" SB4 SBR3
6 '
SB1
ONE WAY SLAB
SLAB THICK. 5"
20'-6" IS 13920
6' 10# @ 6"C/C MAIN BAR
A C3 C3
C1
A SB1 8# @ 6"C/C DIST. BAR
4'
1. ANCHORAGE LENGTH OF TOP/BOTTOM BARS OF
UP MLB BEAMS & COLUMNS IS TO BE TAKEN AS 60 DIA
SB2
10'-6"
10'-6"
OF BARS.
SB3
TWO WAY SLAB
DINING 7'-8" 5'-8" SLAB THICK. 5" 2. ANCHORAGE BARS FROM BOTTOM TO TOP ARE TO
10# @ 6"C/C MAIN BAR
C2 BALCONY BE TAKEN OUT FROM COLUMN AND TAKEN AS TOP
SB5
C1 18'-10" x 11'-2" 8# @ 6"C/C DIST. BAR
5'-2"
5'-2"
11" SUNK RFT. IN BEAMS UPTO 0.25 L.
TOILET DRESS 4'-5"x 10'-10"
7'-0"x 5'-6"
ONE WAY SLAB ONE WAY SLAB
3. EXTERNAL JOINTS OF BEAMS & COLUMNS MUST
7'-8"x 5'-6" SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
SB4 SBR3
8# @ 6"C/C DIST. BAR 8# @ 6"C/C DIST. BAR
HAVE AT LEAST ONE STIRRUPS IN THE FORM OF
4'-4"
U-STIRRUPS & CROSS TIES AS PER I.S.13920 FOR
EARTHQUAKE RESISTANT DUCTILE JOINT.
SB3
SB3
ONE WAY SLAB
SB4
14' SLAB THICK. 5"
10# @ 6"C/C MAIN BAR 14'-6"
3'
C2
8# @ 6"C/C DIST. BAR
4. INTERNAL BEAM & COLUMN JOINTS MUST HAVE
SB5 ATLEAST ONE STIRRUP IN THE FORM OF U-
4'-4" STIRRUPS & CROSS TIES.
TWO WAY SLAB 11" SUNK 5. ALL STIRRUPS & TIES MUST HAVE 10 DIA HOOK.
TWO WAY SLAB
SLAB THICK. 5"
SLAB THICK. 5" 6. IN TOP & BOTTOM HEIGHT OF H/6 OF COLUMNS,
12'
12'
10# @ 6"C/C MAIN BAR
10# @ 6"C/C MAIN BAR
6'-10"
8# @ 6"C/C DIST. BAR
8# @ 6"C/C DIST. BAR TIES AT 100 (4") ARE TO BE COVERED.
M.BEDROOM
TOILET BEDROOM ONE WAY SLAB
14'-0" x 12'-0"
SLAB THICK. 5"
10# @ 6"C/C MAIN BAR
14'-6"x 12'-0" 8# @ 6"C/C DIST. BAR
(B) GENERAL NOTES AS PER IS 456-2000
5'-0"x 7'-2"
SBR3
SBR3
SBR3
SBR3
C2
C2 C2 C2 1. ALL DIMENSIONS ARE IN FEET & INCHES
SB6 2. ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED.
3. P.C.C. (1:5:10).
SB2 SB2 4. CONCRETE MIX= M-20 (1:1.5:3).
5. H.Y.S.D. TOR STEEL BARS SHOULD BE USED.
6. CONCRETE CLEAR COVER TO MAIN RFT. SHALL BE
C D STILT, FIRST & SECOND FLOOR AS FOLLOWS :-
COLUMNS = 25MM ALL SIDES.
FOOTING = 50MM AT BOTTOM & SIDES.
BEAMS = 25MM AT TOP, BOTTOM & SIDES.
SLAB =15 MM AT TOP & BOTTOM.
7. OVERLAP IN COLUMNS IS TO BE PROVIDED AT THE
MID HEIGHT OF COLUMN WITH STAGGER IN THE
MAIN BAR.
8. OVERLAP IN TOP BEAM BARS IS TO BE PROVIDED
NEAR TO THE MID SPAN IN A STAGGERED MANNER.
2 nos. - 12# straight top
2 nos. - 12# straight top L/3 L/3 9. OVERLAP IN BOTTOM BEAM BARS IS TO BE
5"
5"
2 nos. - 16# straight top +1 nos. - 12# extra top 8Ø.@ 6''C/C. STIRRUP PROVIDED NEAR THE SUPPORTS IN A STAGGERED
5" +2 nos. - 12# extra top A
STRAIGHT TOP B EXTRA TOP
MANNER.
11½"
8 # stirrup @ 6''c/c.
11½"
8 # stirrup @ 6''c/c. 10. ALL DIMENSIONS ARE TO BE CHECKED WITH
11½"
2 nos. - 12# straight bottom 8 # stirrup @ 6''c/c.
+2 nos. - 12# extra bottom 2 nos. - 12# straight bottom A' STRAIGHT EXTRA BOTTOM ARCHITECTURAL DRAWINGS .
2 nos. - 16# straight bottom +1 nos. - 12# extra bottom BOTTOM B'
8"
+2 nos. - 12# extra bottom 8" L
8" L/7 L/7
SB1- 8" X 16½" SB5 - 8" X 16½" TYPICAL SLAB BEAM SECTION
SB3 - 8" X 16½"
3 nos. - 12# straight top 3 nos. - 16# straight top 3 nos. - 16# straight top
5"
5"
5"
+3 nos. - 12# extra top +2 nos. - 16# extra top +2 nos. - 16# extra top
2 nos. - 16# straight top
5"
4 nos. - 12# straight top +2 nos. - 12# extra top
5"
11½"
15½"
15½"
3"
4 nos. - 12# straight bottom
11½"
3 nos. - 12# straight bottom 8 # stirrup @ 6''c/c.
+3 nos. - 12# extra bottom 8"
8"
3 nos. - 16# straight bottom
+2 nos. - 16# extra bottom 2 nos. - 16# straight bottom 3 nos. - 16# straight bottom
8" SB6 - 8" X 8" 8" 8"
SB2- 8" X 16½"
SB4 - 8" X 20½" SLAB BEAM LAYOUT
PROPOSED RESIDENCE FOR MR. RAKESH
GUPTA AT DURG, C.G.