Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Non-Ferrous Birotor Plus (Models Ab270, Ab280, Ab290) : Technical Data

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Technical Data

Non-Ferrous BiRotor Plus

(Models AB270, AB280, AB290)

General Design Features


The Non-Ferrous BiRotor Plus meter is a volumetric • Total Quality, High Performance, Completely
flow measuring device designed for the accurate mea- Non-Ferrous
surement of petroleum liquids in aircraft refueling. This • Highest accuracy of any positive displacement meter
double case meter combines the rugged durability and • +/-0.10% accuracy meeting ATA-103 specification
long service life of the traditional BiRotor meter with • Electronic output eliminates high maintenance me-
the improved accuracy and pulse output associated with chanical registers
today’s most sophisticated devices. • Double case construction improves meter factor
stability
Utilizing single or dual outputs, with two non-wetted pick- • No metal-to-metal contact
offs mounted 90° out of phase, the Non-Ferrous BiRotor • Light weight - small footprint
Plus complies with API Level B pulse output standards. • Victaulic connections
Output signals are amplified and shaped by a preampli- • Capable of operating @ 400 cst. max viscosity
fier mounted directly on the meter for transmission to • Capable of Bi-Directional Flow (Consult Factory)
accessories such as totalizing counters, digital readout
devices, provers and other control equipment and instru-
mentation.

The typical application is for aviation fuel measurement


where the meter must be of non-ferrous material. This
includes fueling and defueling where the meter comes
in direct contact with the airplane or helicopter. The
meter is designed for use on refueling trucks and hydrant
trucks/carts. With a maximum operating pressure of 200
psig, the meter meets the SAE specifications for hydrant
refuelers.

Technical Data DS Non-Ferrous Plus R03 Page 1/4


Performance Preamplifier Performance
Repeatability: +/- 0.02% Inputs
Linearity: +/- 0.1% or better over 20:1 flow range Supply Voltage: 10 to 30 Vdc
• Premium Linearity of Less than 0.1% Available Sensor Type: Reluctance
(Consult Factory) Type: Sine Wave
• AB270: +/- 0.1% over std. flow range Amplitude: 40 mV peak to peak minimum
• AB280: +/- 0.075% over std. flow range Outputs
• AB290: +/- 0.075% over std. flow range Powered Pulse Output
• Type: Square Wave
Materials of Construction • Frequency Range: 0 to 5 kHz
Housing: Cast Aluminum • Amplitude : 0 to 5 V
Measuring Unit • 1 kOhm interval pull-ups, 20 mA max.
• End Plates: Cast Aluminum Variable Voltage Output
• Rotors: Cast Aluminum, Hard Anodized • Type: Square Wave
• Rotor Shafts: 17-4 ph Stainless Steel • Frequency Range: 0 to 5 kHz.
• Rotor Bearings: Hybrid Ceramic • Amplitude: 0 to Supply Voltage
O-Rings: Viton Standard (Other elastomers available) • 1 kOhm internal pull-ups, 70 mA max.
Open Collector Output (Per Channel)
Specifications - Electrical • Type: Square Wave
Dual channel preamplifier • Frequency Range: 0 to 5 kHz.
Single or dual, non-wetted, reluctance pick-offs • Max. Voltage: 30 Vdc
• Max. Current: 125 mA
• Max. Power: 0.5 watts
Temperature: -20 to 180°F (-29 to 82°C)
Pick-off Temperature: -20 to 180°F (-29 to 82°C)

Technical Data DS Non-Ferrous Plus R03 Page 2/4


Typical Pressure Drop Curve Typical Accuracy Curve

Specifications - Meter
Maximum Extended Flow Range
Maximum Nominal
Model Safe
Connections Safe Working Standard Flow Intermittent K Factor
Number Working Minimum*
Pressure Maximum +/- 10%
Temp
AB270 3" Victaulic 200 PSI -20 to 180 F 43 - 425 GPM 30 GPM 550 GPM
160 PUL/GAL
76.20 mm 42 PUL/L
AB270 1378 Kpa -29 to 82 C 163 - 1609 LPM 114 LPM 2082 LPM
Victaulic
AB280 4" Victaulic 200 PSI -20 to 180 F 70 - 700 GPM 33 GPM 1000 GPM
101.60 mm 265 - 2650
AB280 1378 Kpa -29 to 82 C 125 LPM 3785 LPM
Victaulic LPM 96 PUL/GAL
AB290 6" Victaulic 200 PSI -20 to 180 F 100 - 1000 GPM 40 GPM 1200 GPM 25 PUL/L
152.40 mm
AB290 1378 Kpa -29 to 82 C 379 - 3785 LPM 151 LPM 4542 LPM
Victaulic

ANSI Flange (optional) - 200 PSI Rating


* Linearity +/- 0.15 for conditions between extended maximum flow and standard minimum flow.

Technical Data DS Non-Ferrous Plus R03 Page 3/4


Dimensions

Model A B C D E F G H J
18-15/16 6 14-9/16 11-1/2 5-3/4 3-11/16 1-3/8 4-3/4 9-1/2
AB270 (481) (152) (370) (292) (146) (94) (35) (121) (241)
26-1/2 6-11/16 15-7/8 13-1/8 6-9/16 6 1-3/8 6-11/16 13-1/8
AB280 (673) (170) (403) (333) (167) (167) (35) (170) (333)
25-5/8 6-11/16 15-15/16 13-1/8 6-9/16 5-9/16 1-3/8 6-1/4 13-1/8
AB290 (651) (170) (405) (333) (167) (141) (35) (159) (333)

NOTE:
Do not operate this instrument in excess of the
specifications listed. Failure to heed this warning
could result in serious injury and/or damage to the
equipment.

Brodie International

P.O. Box 450 (30459-0450)


19267 Highway 301 North
Statesboro, GA 30461
USA

Phone: +1 (912) 489-0200


Fax: +1 (912) 489-0294

Technical Data DS Non-Ferrous Plus R03 Page 4/4