AltechCorp - Power Supplies
AltechCorp - Power Supplies
AltechCorp - Power Supplies
ENERGY SAVER
Choose your product from a wide range of features and options, suitable for almost all applications.
Slimline Small in size - narrow footprint Powerful with generous power reserves Simple usage 10W to 100W Single Phase Low Profile Installs in seconds Simple usage Robust plastic case 15W to 100W Industrial Metal Case Single Phase Single Phase Power Supply (75 to 480W) Rugged metal case Industrial Metal Case Three Phase Three Phase Power Supply (240 to 960 W) Rugged metal case High Efficiency Compact Housing Universal input voltage Rugged metal case 150% peak load capacity Wide input voltage Rugged metal case 120W to 480W Accessories Redundancy Buffer Module UPS Module 82-91 72-81 60-71 44-59 34-43 20-33 6-19
92-94 95 94-97 98
Din Rail mount, Wide Power Range (10W-960W) Wide Adjustment Range Rugged for Industrial Use High Efficiency Lightweight and compact Design 3 year warranty
Short circuit Protection Overvoltage Protection Overload Protection Overtemperature Protection Cooling by free air convection Worldwide approvals UL508 Listed and/or UL60950-1 recognized
Multiple output connector for easy wiring Adjustable DC output voltage DC (on) LED indicator
UL508 Listed CE compliance Universal Input Narrow for maximized panel space
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
SPECIFICATIONS
Input
Input Voltage 90-264V AC for single phase 100-550V AC for wide input 340-550V AC for three phase Input Frequency: 47-63 Hz Input Current: 0.6 A to 8A Inrush Current: cold start up to 60 A max Power Factor: All units are EN61000-3-2 compliant
Output
Output Voltage: 5V; 12V; 15V; 24V; 48V Output Voltage Adjustment Range: 10% Initial Set Accuracy: 2% max Ripple & Noise: See data sheet Over-voltage Protection: 115-135% Overload Protection: 105-150%, constant current with auto recovery
General
Efficiency: 72-94% (see data sheets) Isolation: 3000V AC Input to Output 1500V AC Input to Ground 500V AC Output to Ground
Environmental
Power supplies can run at 100% capacity inside the panel, there is no need for oversizing. See derating curves for more information. Operating Temperature: -20 to +60C (-4 to +140F) Operating Humidity: 90% RH, non-condensing Storage Temperature: -20 C to +85 C (-4 to +185F) Vibration: 2G, 10 Hz to 500 kHz, 10 min/cycle for 60 minutes each axis
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
Input voltage range: AC inrush current (max): Cold start: DC adjustment range: Overload protection: Over-voltage protection: Setup, rise, time (max): Withstand voltage: Working temperature: Safety standards: EMC standards:
Military Standard
85-264V AC; 120-370V DC 20A at 115V AC,; 40A at 230V DC 10% rated output voltage 105%-160% constant current limiting (auto- recovery) 115%-135% rated output voltage 500ms, 30ms/230V AC 1000ms, 30ms/115V AC, at full load I/P-O/P: 3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC -20 to +70C (-4 to +158F), refer to output derating curve UL508, EN60950-1 EN55022 class B EN61000-4-2,3,4,5,6,8,11 ENV50204; EN55024; EN61000-6-1; EN61204-3; Light Industry Level criteria A MIL-HDBK-217F
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
PS-S Series
ENERGY SAVER
Features: Universal AC input/Full range Protections: Short circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant (12V,24V,48V only) LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 year warranty
Multiple output connector for easy wiring on PS-S40, PS-S60 and PS-S100 models
DC on LED signal
Easy to understand layout panel CE Compliance UL508 Listed Robust plastic housing Universal Input Slim Series - narrow for maximized panel space
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
10-100W Slimline
POWER SUPPLIES
ENERGY SAVER
Pin No. 1 2 3
PS-S10xx
10
0 22 .5
Universal Input: 85-264V AC, 120-370V DC full range; 0.33A @ 110V AC; 0.21A @ 230V AC Connection: Input - 2 poles, Output 2 poles, single screw terminal Size (WxHxD): 22.5x90x100mm (0.89x3.54x3.94 inches) Packaging: 1/box; 0.37lbs / 0.17Kg
PS-S20 Series
Pin No. 1 2 3
PS-S20xx
10
0 22 .5
Universal Input: 85-264V AC, 120-370V DC full range; 0.55A @ 110V AC; 0.35A @ 230V AC Connection: Input - 2 poles, Output 2 poles, single screw terminal Size (WxHxD): 22.5x90x100mm (0.89x3.54x3.94 inches) Packaging: 1/box; 0.42lbs / 0.19Kg
PS-S40 Series
90
PS-S40xx
10
0 40
Universal Input: 85-264V AC, 120-370V DC full range; 1.1A @ 115V AC, 0.7A @ 370V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 40x90x100mm (1.57x3.54x3.94 inches) Packaging: 1/box; 0.66lbs / 0.3Kg
PS-S60 Series
90
PS-S60xx
10
0 40
Universal Input: 85-264V AC, 120-370V DC full range; 1.8A @ 115V AC, 1A @ 370V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 40x90x100mm (1.57x3.54x3.94 inches) Packaging: 1/box; 0.73lbs / 0.33Kg
Terminal Pin. No Assign. (TB1)
Pin No. 1 2 3 Assignment FG AC/N AC/L
PS-S100 Series
90
PS-S100xx
10
55
Universal Input: 85-264V AC, 120-370V DC full range; 1.3A @ 115V AC, 0.8A @ 230V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 55x90x100mm (2.17x3.54x3.94 inches) Packaging: 1/box; 0.93lbs / 0.42Kg
Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
PS-S10 Series
Specifications
YGRENE REVAS
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant Built in DC OK active signal LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME
PS-S1005
5V 2A 0~2A 10W 80mVp-p 5.0%
PS-S1012
12V 0.84A 0~0.84A 10W 120mVp-p 3.0%
PS-S1015
15V 0.67A 0~0.67A 10W 120mVp-p 3.0%
PS-S1024
24V 0.42A 0~0.42A 10W 150mVp-p 2.0% 1.0% 2.0%
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor Tolerance: includes set up tolerance, line regulation and load regulation.
1.0% 1.0% 1.0% 5.0% 3.0% 3.0% 500ms, 30ms/230VAC; 1000ms, 30ms/115VAC at full load 120ms/230VAC; 25ms/115VAC at full load 85~264VAC; 120~370VDC 47~63Hz 77% 81% 0.33A/115VAC; 0.21A/230VAC COLD START: 35A/115VAC; 70A/230VAC <1mA/ 240VAC Above 105% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVERVOLTAGE PROTECTION OVER TEMPERATURE PROTECTION DC OK AKTIV SIGNAL (max.)
81%
84%
PROTECTION
5.75~6.75V
13.8~16.2V
17.25~20.25V
27.6~32.4V
Power supply shut down at 70C constant current limiting / output voltage goes to 0; re-power on to recover 3.75~6V (50mA) 9~13.5V (40mA) 11.5~16.5V (40mA) 18~27V (20mA) -20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C; 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1compliant NEC class2 / LPS compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-1;EN61204-3; light industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
OTHERS
584K hrs min. MIL-HDBK-217K (25C) 22.5x90x100mm (WxHxD) 0.17Kg; 72pcs / 13.2Kg / 0.91CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
10
Mechanical Specification
22.5 5 5 100
+V -V DC OK
90
N L
5 5
Block Diagram
EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V
I/P
Application of DC OK Signal
5.1V V-
R 1K 2.4K 3K 4.7K V-
Relay
RL
Derating Curve
100
Others
90 80
80
60 40
5V
70 60 50
20
40
-20
10
20
30
40
50
60
70 (VERTICAL)
85
95
100 115
120 140
160 180
200 220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
11
PS-S20 Series
Specifications
ENERGY SAVER
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant Built in DC OK active signal LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME
PS-S2005
5V 3A 0~3A 15W 80mVp-p 4.75 ~ 5.5V 2.0%
PS-S2012
12V 1.67A 0~1.67A 20W 120mVp-p 10.8 ~ 13.2V 1.0%
PS-S2015
15V 1.34A 0~1.34A 20W 120mVp-p 13.5 ~ 16.5V 1.0%
PS-S2024
24V 1A 0~1A 24W 150mVp-p 21.6 ~ 26.4V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 500ms, 30ms/230VAC; 1000ms, 30ms/115VAC at full load 50ms/230VAC; 20ms/115VAC at full load 85~264VAC 120~370VDC 47~63Hz 76% 80% 0.55A/115VAC; 0.35A/230VAC COLD START: 20A/115VAC; 40A/230VAC 1mA/ 240VAC 105% ~ 160% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT
81%
84%
PROTECTION
OVERLOAD PROTECTION OVERVOLTAGE PROTECTION OVER TEMPERATURE PROTECTION DC OK AKTIV SIGNAL (max.)
5.75~6.75V
13.8~16.2V
17.25~20.25V
27.6~32.4V
Power supply shut down at 70C constant current limiting / output voltage goes to 0; re-power on to recover 3.75~6V (50mA) 9~13.5V (40mA) 11.5~16.5V (40mA) 18~27V (20mA) -20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1approved NEC class2 / LPS compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-1;EN61204-3; light industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
OTHERS
MTBF DIMENSION PACKING
236.9K hrs min. MIL-HDBK-217K (25C) 22.5x90x100mm (WxHxD) 0.19Kg; 72pcs / 14.7Kg / 0.91CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
12
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
22.5 5 5 100
+V -V DC OK
+
90
+V ADJ
N L
5 5
Block Diagram
EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V
I/P
Application of DC OK Signal
5.1V V-
R 1K 2.4K 3K 4.7K V-
Relay
RL
Derating Curve
100
80
80 70 60 50
60 40
20
40
-20
10
20
30
40
50
60
70 (VERTICAL)
85
95
100 115
120 140
160 180
200 220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
13
PS-S40 Series
Specifications
ENERGY SAVER
Features:
Universal AC input/full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant (12V,24V,48V only) LED indicator for power on DC OK relay contact No load power consumption < 0.75W 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
PS-S4005
5V 6A 0~6A 30W 80mVp-p 5 ~ 6V 2.0%
PS-S4012
12V 3.33A 0~3.33A 40W 120mVp-p 12 ~ 15V 1.0%
PS-S4024
24V 1.7A 0~1.7A 40.8W 150mVp-p 24 ~ 30V 1.0%
PS-S4048
48V 0.83A 0~0.83A 39.8W 200mVp-p 48 ~ 56V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load 50ms/230VAC; 20ms/115VAC at full load 85~264VAC 120~370VDC 47~63Hz 78% 86% 1.1A/115VAC; 0.7A/230VAC COLD START: 30A/115VAC; 60A/230VAC 1mA/ 240VAC 105% ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
PROTECTION
VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVERVOLTAGE PROTECTION OVER TEMPERATURE PROTECTION DC OK AKTIV SIGNAL (max.)
88%
88%
6.25~7.25V
15.6~18V
31.2~36V
57.6~64.8V
Power supply shut down at 70C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/ 1A resistive -20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 UL60950-1 EN60950-1approved NEC class2 / LPS compliant (12V, 24V, 48V only) I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204 ; EN61000-6-2; EN61204-3; light industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
OTHERS
301.7K hrs min. MIL-HDBK-217K (25C) 40x90x100mm (WxHxD) 0.3Kg; 42pcs / 13.6 Kg / 0.82CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
14
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
40 5 5 5 5 5 100
+V +V-V -V
+
90 +V ADJ
7.5 7.5
Block Diagram
I/P
EMI FILTER
POWER SWITCHING
+V -V
O.L.P.
CONTROL O.V.P.
DC OK Relay Contact
age.
Derating Curve
100
80
80 70 60 50
60 40
20
40
-20
10
20
30
45
55
60
70 (VERTICAL)
85
95
100 115
120 140
160 180
200 220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
15
PS-S60 Series
Specifications
ENERGY SAVER
Features:
Universal AC input/full range Protections: Short Circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable NEC class 2 / LPS compliant (24V,48V only) LED indicator for power on No load power consumption < 0.75W 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME
PS-S6005
5V 10A 0 ~ 10A 50W 80mVp-p 5 ~ 6V 2.0%
PS-S6012
12V 5A 0 ~ 5A 60W 120mVp-p 12 ~ 15V 1.0%
PS-S6024
24V 2.5A 0 ~ 2.5A 60W 150mVp-p 24 ~ 30V 1.0%
PS-S6048
48V 1.25A 0 ~ 1.25A 60WRIPPLE & 200mVp-p 48 ~ 56V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
1.0% 1.0% 1.0% 1.5% 1.0% 1.0% 500ms, 30ms/230VAC; 500ms, 30ms/115VAC at full load 50ms/230VAC / 20ms/115VAC at full load 85 ~ 264VAC 120 ~ 370VDC 47~63Hz 78% 86% 1.8A/115VAC; 1A/230VAC COLD START: 60A/230VAC 1mA/ 240VAC 105% ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVERVOLTAGE PROTECTION OVER TEMPERATURE PROTECTION DC OK AKTIV SIGNAL (max.)
88%
87%
PROTECTION
6.25 ~ 7.25V
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
Power supply shut down at 70C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/1A resistive -20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 UL60950-1 EN60950-1approved NEC class2 / LPS compliant (24V, 48V only) I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; light industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
OTHERS
299.2K hrs min. MIL-HDBK-217K (25C) 40x90x100mm (WxHxD) 0.33Kg; 42pcs / 14.8Kg / 0.82CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
16
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
40 5 5 5 5 5 100
+V +V-V -V
+
90 +V ADJ
7.5 7.5
Block Diagram
I/P
EMI FILTER
POWER SWITCHING
+V -V
O.L.P.
CONTROL O.V.P.
DC OK Relay Contact
age.
Derating Curve
100
12V,24V,48V
90
80
80 70
60 50 40
5V
60 50
20
40
-20
10
20
30
45
55
60
70 (VERTICAL)
85
95
100 115
120 140
160 180
200 220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
17
PS-S100 Series
Specifications
YGRENE REVAS
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Overvoltage / Over temperature ZCS/ZVS technology to reduce power dissipation Cooling by free air convection DIN rail mountable DC OK relay contact No load power consumption < 1W LED indicator for power on 100% full load burn-in test 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME
PS-S10012
12V 7.5A 0 ~ 7.5A 90W 120mVp-p 12 ~ 15V 1.0%
PS-S10024
24V 4A 0 ~ 4A 96W 150mVp-p 24 ~ 30V 1.0%
PS-S10048
48V 2A 0 ~ 2A 96W 200mVp-p 48 ~ 56V 1.0% 1.0% 1.0%
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
1.0% 1.0% 1.0% 1.0% 3000ms, 50ms/230VAC; 3000ms, 50ms/115VAC at full load 50ms/230VAC; 20ms/115VAC at full load 85 ~ 264VAC 120 ~ 370VDC
Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
INPUT
HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (max) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE SHORT CUIRCUIT PROTECTION
Deating maybe needed under low input voltages, please check the derating curve for more detail
PROTECTION
47~63Hz PF 0.95/230VAC; PF 0.98/115VAC at full load 85% 86% 1.3A/115VAC; 0.8A/230VAC COLD START: 30A/115VAC; 60A/230VAC 1mA/ 240VAC 105% ~ 150% rated output power
88%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
15.6 ~ 18V
31.2 ~ 36V
57.6 ~ 64.8V
ENVIRONMENT
DC OK AKTIV SIGNAL (max.) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION
Power supply shut down at 70C constant current limiting / output voltage goes to 0; re-power on to recover Relay contact rating (max.): 30V/1A resistive -10 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1compliant I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25C/70% RH Compliance to EN55011 EN55022 (CISPR22) EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; light industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
OTHERS
346K hrs min. MIL-HDBK-217K (25C) 55x90x100mm (WxHxD) 0.42Kg; 30pcs / 13.6Kg / 0.82CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
18
Mechanical Specification
Block Diagram
DC OK Relay Contact
Derating Curve
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
19
Input voltage range: AC inrush current: DC adjustment range: Overload protection: Over-voltage protection: Setup, rise, hold up time: Withstand voltage: Working temperature: Safety standards: EMC standards:
Military Standard:
85-264V AC; 120-370V DC Cold start: 15A at 115V AC, 30A at 230V DC (PS-30xx) 10% rated output voltage 105%-160% constant current limiting, auto-recovery 115%-135% rated output voltage 100ms, 30ms, 100ms at full loadand 230V AC (PS-30xx) I/P-O/P:3KV AC, I/P-FG:1.5KV AC -20 to +50C (-4 to +122F) at 100% and +60C (+140F) at 80% load UL60950-1, UL508 EN55022 class B EN61000-4-2,3,4,5,6,8,11 ENV50204 EN61204-3 MIL-HDBK
20
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
ENERGY SAVER
Features: Universal AC input/Full range Protections: Short circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty
DC on LED signal Adjustable DC output voltage 35mm DIN Rail Mounting Easy to understand layout panel UL508 Listed Robust plastic housing Universal Input
21
POWER SUPPLIES
ENERGY SAVER
NOTES
ENERGY SAVER
NOTES
22
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
56 25
Universal Input: 85-264V AC, 120-370V DC full range; 0.88A @ 115V AC; 0.48A @ 230V AC Connection: Input - 2 poles, Output 2 poles, single screw terminal Size (WxHxD): 25x93x56mm (0.98x3.66x2.20 inches) Packaging: 1/box; 0.22lbs / 0.1Kg
Terminal Pin. No Assignment
Pin No. 1 2 3,4 Assignment Pin No. Assignment AC/L 5,6 -V AC/N LED 7 +V ADJ. +V 8
PS-30 Series
93
56
78
Universal Input: 85-264V AC, 120-370V DC full range; 0.88A @ 115V AC; 0.48A @ 230V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 78x93x56mm (3.07x3.66x2.20 inches) Packaging: 1/box; 0.60lbs / 0.27Kg
PS-45 Series
93
67
78
Universal Input: 85-264V AC, 120-370V DC full range; 1.5A @ 115V AC, 0.75A @ 230V AC Connection: Input - 3 poles, Output 2 poles, double screw terminal Size (WxHxD): 78x93x67mm (3.07x3.66x2.64 inches) Packaging: 1/box; 0.68lbs / 0.31Kg
PS-60 Series
93
56
78
Universal Input: 88-264V AC, 124-370V DC full range; 1.2A @ 115V AC, 0.8A @ 230V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 78x93x56mm (3.07x3.66x2.20 inches) Packaging: 1/box; 0.66lbs / 0.30Kg
PS-100 Series
93
56
10
Universal Input: 88-264V AC, 124-370V DC full range; 3A @ 115V AC, 1.6A @ 230V AC Connection: Input - 2 poles, Output 2 poles, double screw terminal Size (WxHxD): 100x93x56mm (3.94x3.66x2.20 inches) Packaging: 1/box; 0.77lbs / 0.35Kg
Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
23 12
PS-15 Series
Specifications
ENERGY SAVER
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on No load power consumption<0.5W 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) OVERLOAD
PS-1505
5V 2.4A 0 ~ 2.4A 12W 80mVp-p 4.75 ~ 5.5V 2.0%
PS-1512
12V 1.25A 0 ~ 1.25A 15W 120mVp-p 10.8 ~ 13.2V 1.0%
PS-1515
15V 1A 0 ~ 1A 15W 120mVp-p 13.5 ~ 16.5V 1.0%
PS-1524
24V 0.63A 0 ~ 0.63A 15.2W 150mVp-p 21.6 ~ 26.4V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
INPUT
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load 70ms / 230VAC 16ms / 115VAC at full load 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 77% 84% 0.88A / 115VAC 0.48A / 230VAC COLD START 35A / 115VAC 65A / 230VAC 105 ~ 160% rated output power
83.50%
85%
PROTECTION
Protection type: Constant current limiting recovers automatically after fault condition is removed (Hiccup mode) Constant current operation region is within 60 ~ 100% rated output voltage.
OVERVOLTAGE
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55011 EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
1172.3K hrs min. MIL-HDBK-217K (25C) 25x93x56mm (WxHxD) 0.1Kg; 140pcs / 15Kg / 0.92CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
24
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
56 25 5 26.7 47
+V
-V
Block Diagram
I/P
EMI FILTE R
POWE R SWITCHING
+V -V
Derating Curve
100
80
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (VERTICAL)
80 70 60 50
60 40
20
40
-20
85
95
100
115
120
140
160
180
200
220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
25
PS-30 Series
Specifications
Features:
Universal AC input/ full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
PS-3005
5V 3A 0 ~ 3A 15W 80mVp-p 4.75 ~ 5.5V 2.0% 1.0% 1.0% 100ms, 30ms / 230VAC 100ms / 230VAC
PS-3012
12V 2A 0 ~ 2A 24W 120mVp-p 10.8 ~ 13.2V 1.0%
PS-3015
15V 2A 0 ~ 2A 30W 120mVp-p 13.5 ~ 16.5V 1.0%
PS-3024
24V 1.5A 0 ~ 1.5A 36W 150mVp-p 21.6 ~ 26.4V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
1.0% 1.0% 1.0% 1.0% 100ms, 30ms / 115VAC at full load 21ms / 115VAC at full load
INPUT
PROTECTION
VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) OVERLOAD OVERVOLTAGE
85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 74% 81% 0.88A / 115VAC 0.48A / 230VAC COLD START 15A / 115VAC; 30A / 230VAC 105 ~ 160% rated output power
82%
83%
Protection type: Constant current limiting recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms / 500VDC Compliance to EN55011 EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
441.5K hrs min. MIL-HDBK-217K (25C) 78x93x56mm (WxHxD) 0.27Kg; 48pcs / 14Kg / 1.02CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
26
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
56 78 5 37.75 5 5 5 12.2 27.4 47
3 4 5 6 7 93 45 3 68 8
Block Diagram
I/P
E MI FILTE R
1 2
POWE R SWITCHING
+V -V
Derating Curve
100
80
80
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (VERTICAL)
60 40
70 60 50
20
40
-20
85
95
100
115
120
140
160
180
200
220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
27
PS-45 Series
Specifications
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage/ Overtemperature Cooling by free air convection DIN rail mountable UL508 approved LED indicator for power on Fix switching frequency at 100kHz 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PS-4505
5V 5A 0 ~ 5A 25W 100mVp-p 4.75 ~ 5.5V 2.0%
PS-4512
12V 3.5A 0 ~ 3.5A 42W 200mVp-p 10.8 ~ 13.2V 1.0%
PS-4515
15V 2.8A 0 ~ 2.8A 42W 240mVp-p 13.5 ~ 16.5V 1.0% 1.0% 1.0%
PS-4524
24V 2A 0 ~ 2A 48W 480mVp-p 21.6 ~ 26.4V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
INPUT
1.0% 1.0% 1.0% 1.0% 800ms, 60ms / 230VAC at full load 60ms / 230VAC at full load 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 72% 77% 1.5A / 115VAC 0.75A / 230VAC COLD START 28A / 115VAC; 56A / 230VAC 1mA / 240VAC 105 ~ 160% rated output power
77%
80%
PROTECTION
Protection type: Constant current limiting recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
ENVIRONMENT
WORKING TEMPERATURE WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
-10 ~ +50C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
364.6K hrs min. MIL-HDBK-217K (25C) 93x78x67mm (LxWxH) 0.31Kg; 48pcs / 16.1Kg / 1.3CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
28
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
78 7.5 8.5 29 67
3 4
93
Block Diagram
I/P E MI FILTE R RE CTIFIE RS & FILTE R POWE R SWITCHING PWM CONTR OL FG RE CTIFIE RS & FILTE R DE TE CTION CIRCUIT +V -V
Derating Curve
100
77
28
80
300 250 200 150 100 50 70 80 100 120 140 160 180 200 220 240 260
24
60 40
20 16 12
20
8
-10 0 10 20 30 40 50 60 (VERTICAL)
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
32
350
LOAD (%)
LOAD (%)
29
PS-60 Series
Specifications
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) OVERLOAD OVERVOLTAGE
PS-6005
5V 6.5A 0 ~ 6.5A 32.5W 80mVp-p 4.75 ~ 5.5V 2.0% 1.0% 1.0% 100ms, 30ms / 230VAC 100ms / 230VAC
PS-6012
12V 4.5A 0 ~ 4.5A 54W 120mVp-p 11.1 ~ 13.2V 1.0%
PS-6015
15V 4A 0 ~ 4A 60W 120mVp-p 13.5 ~ 16.5V 1.0%
PS-6024
24V 2.5A 0 ~ 2.5A 60W 150mVp-p 21.6 ~ 26.4V 1.0% 1.0% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor
INPUT
1.0% 1.0% 1.0% 1.0% 200ms, 30ms / 115VAC at full load 23ms / 115VAC at full load
PROTECTION
85 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 76% 82% 1.2A / 115VAC 0.8A / 230VAC COLD START 18A / 115VAC; 36A / 230VAC 105 ~ 160% rated output power
83%
84%
Protection type: Constant current limiting recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL60950-1 EN60950-1approved Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55011 EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; EN61204-3; heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
216.2K hrs min. MIL-HDBK-217K (25C) 78x93x56mm (WxHxD) 0.3Kg; 48pcs / 15.4Kg / 1.02CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature
30
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
56 78 5 37.75 5 5 5 12.2 27.4 47
1 2
3 4 5 6 7 93 45 3 68 8
Block Diagram
I/P
E MI FILTE R
POWE R SWITCHING
+V -V
O.L.P.
PWM CONTR OL
Derating Curve
100
80
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (VERTICAL)
80 70 60 50
60 40
20
40
-20
85
95
100
115
120
140
160
180
200
220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
31
PS-100 Series
Specifications
YGRENE REVAS
Features:
Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on No load power consumption<1W 100% full load burn-in test 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) OVERLOAD
PS-10012
12V 7.5A 0 ~ 7.5A 90W 120mVp-p 12 ~ 15V 2.0% 1.0% 1.0% 2700ms, 80ms / 230VAC 50ms / 230VAC
PS-10015
15V 6.5A 0 ~ 6.5A 97.5W 120mVp-p 15 ~ 18V 1.0% 1.0% 1.0% 2700ms, 80ms / 115VAC at full load 18ms / 115VAC at full load
PS-10024
24V 4.2A 0 ~ 4.2A 100.8W 150mVp-p 24 ~ 29V 1.0% 1.0% 1.0%
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
PROTECTION
88 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 87% 87% 3A / 115VAC 1.6A / 230VAC COLD START 30A / 115VAC; 45A / 230VAC 105 ~ 135% rated output power
89%
Protection type: Constant current limiting recovers automatically after fault condition is removed Under short circuit or overload 150% conditions, output voltage may shut down for 5 sec. and then go into constant current protection mode
OVERVOLTAGE OVERTEMPERATURE
16 ~ 20V
19 ~ 23V
30 ~ 35V
ENVIRONMENT
90C 15C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover -20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
UL60950-1 EN60950-1compliant Design refer to EN50178 WITHSTAND VOLTAGE I/P-O/P: 3KVAC ISOLATION RESISTANCE I/P-O/P: 100M Ohms/500VDC (25C; 70% RH) EMI CONDUCTION & RADIATION Compliance to EN61204-3; EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3
Harmonic current test @ 90% load
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; EN61204-3; heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
OTHERS
486K hrs min. MIL-HDBK-217K (25C) 100x93x56mm (WxHxD) 0.35Kg; 36pcs / 13.6Kg / 0.89CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
32
Mechanical Specification
56 100 5 64.75 5 5 5 7.5 27.4 47
1 2
3 4 5 6 7
93 45 3 68 8
Block Diagram
I/P
EMI FILTER
POWER SWITCHING
+V -V
O.L.P.
PWM CONTROL
Derating Curve
100
80
LOAD (%)
LOAD (%)
0 10 20 30 40 45 50 60 70 (VERTICAL)
80 70 60 50
60 40
20
40
-20
88
95
100 110
120 140
160 180
200 220
240
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
33
Industrial Metal Case Single Phase and Three Phase Power Supply
The Altech Industrial metal case power supplies have been optimized for use in practically any DC power applications, with a wide range of AC/DC inputs and an extended temperature range of -20 C up to +70 C. These metal case power supplies feature a small housing design and high power reserve. Excellent electrical specifications and high immunity against fluctuations in input voltage make these metal case modules the best choice to industrial automation. Altechs metal case power supplies are available in six single-phase and four three-phase models with 12VDC (75W and 120W), 24 VDC and 48VDC output voltages, and up to 40A output currents. This voltage range enables the Industrial metal case supplies to be used in virtually any single-phase or three-phase application. The Industrial metal case power supply series offers users easy wiring with screw terminal blocks and snap-on DIN-rail mounting. Designed for use in numerous applications around the world, this power supplies are UL and CSA approved, CE marked and ROHS compliant. They feature a rugged metal housing, vibration- and shock-proof construction and provide a cost-effective power delivery solution for basic functionality requirements. Single Phase Power Supply:
Input voltage range: AC inrush current: Cold start: Overload voltage protection: Over-voltage protection: Setup, rise, hold up time: Working temperature: 85-264V AC / 120-370V DC 20A at 115V AC, 40A at 230V AC 105%-160% constant current limiting auto-recovery 115%-135% rated output voltage 500ms; 70ms; 30ms at full load and 230V AC -20 to +50C (-4 to +122F) at 100% +60C (+140F) at 80% load
Single Phase 75-240W.............................................................................pages 36-45 480W and 480W Switch Select..........................................pages 46-51 Three Phase 240-960W...........................................................................pages 52-59
34
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Multiple output connector for easy wiring Narrow for maximized panel space
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
35
POWER SUPPLIES
SWITCH SELECT
HIGH INPUT
240W Single Output DIN Rail Power Supply with PFC Function
Cat. No. PSP-24024 PSP-24048 Output V DC A 24V DC 48V DC 10A 5A Tol. % 1% 1% Ripple & Noise 80 mVp-p 150 mVp-p Efficiency 84% 85% NOTES
36
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
SPECIFICATIONS
PS-75 Series
12 5.2
Universal Input:
10
55
.5
85-264V AC, 120-370V DC full range, 1.6A @ 115V AC, 0.96A @ 230V AC Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 55.5x125x100mm (2.20x4.95x3.95 inches) Packaging: 1/box; 1.35lbs / 0.60Kg
PS-120 Series
(Switch Select)
12 5.2
10
65
.5
Switch select Input: 88-132V AC / 176-264 V AC, 248-370V DC range, 2.6A @ 115V AC, 1.6A @ 230V AC Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 65.5x125x100mm (2.56x4.95x3.95 inches) Packaging: 1/box; 1.75lbs / 0.79Kg
12
5.2
10
65
.5
340-550V AC, 480-780V DC range, 0.65A @ 400V AC, 0.6A @ 500V AC Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 65.5x125x100mm (2.56x4.95x3.95 inches) Packaging: 1/box; 1.65lbs / 0.75Kg
PSP-240 Series
25 .2
Universal Input:
10
12
5.5
85-264V AC, 120-370V DC full range, 2.8A @ 115V AC, 1.4A @ 230V AC Built in active Power Factor Correction function. PF>0.95 Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 125x125x100mm (4.95x4.95x3.95 inches) Packaging: 1/box; 2.7lbs / 1.2Kg Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
37
PS-75 Series
Specifications
Features:
Univers al AC input / full range Protections: Short Circuit / Over load / Overvoltage / Over temperature Cooling by free air convection DIN rail mountable UL508 (industrial control equipment) approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 50KHz 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PS-7512
12V 6.3A 0 ~ 6.3A 76W 100mVp-p 12 ~ 14V 2.0% 0.5% 1.0% 1000ms, 60ms / 230VAC 60ms / 230VAC
PS-7524
24V 3.2A 0 ~ 3.2A 76.8W 150mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 1800ms, 60ms / 115VAC at full load 12ms / 115VAC at full load
PS-7548
48V 1.6A 0 ~ 1.6A 76.8W 240mVp-p 48 ~ 53V 1.0% 0.5% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
PROTECTION
85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 76% 1.6 A / 115VAC 0.96A / 230VAC COLD START 20A / 115VAC 1mA / 240VAC 105 ~ 150% rated output power
81%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
15 ~ 16.5V
29 ~ 34V
58 ~ 65V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
-10 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2) heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
123.1K hrs min. MIL-HDBK-217K (25C) 55.5x125.2x100mm (WxHxD) 0.6Kg; 20pcs / 13Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
38
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
55.5
1 2 3 4 3 2 1
125.2
TB2 LE D
TB1
100
Block Diagram
RECTIFIERS & FILTER RECTIFIERS & FILTER
I/P
EMI FILTER
POWER SWITCHING
+V -V
FG
Derating Curve
100
24V,48V
90
80
LOAD (%)
LOAD (%)
50 60 (VERTICAL)
12V
80 70 60 50
60 40
20
40 0 10 20 30 45
-10
85
90
105
125
145
165
185
205
225
245 265
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
39
PS-120 Series
Specifications
Features:
Universal AC input / full range Protections: Short Circuit / Over load / Overvoltage/Over temperature Cooling by free air convection DIN rail mountable TS-35/ 7.5 or 1 5 UL 508 (industrial control equipment) approved LED indicator for power on 100% full load burn-in test Fix switching frequency at 50KHz 3 year warranty
SWITCH SELECT
110/220V
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
PS-12012
12V 10A 0 ~ 10A 120W 80mVp-p 12 ~ 14V 2.0% 0.5% 1.0% 500ms, 70ms / 230VAC 36ms / 230VAC
PS-12024
24V 5A 0 ~ 5A 120W 80mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 500ms, 70ms / 115VAC at full load 32ms / 115VAC at full load 248 ~ 370VDC
PS-12048
48V 2.5A 0 ~ 2.5A 120W 100mVp-p 48 ~ 53V 1.0% 0.5% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PROTECTION
88 ~ 132VAC / 176 ~ 264VAC by switch 47 ~ 63Hz 80% 84% 2.6 A / 115VAC 1.6A / 230VAC COLD START 20A / 115VAC 40A / 230VAC 3.5mA / 240VAC 105 ~ 150% rated output power
85%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Protection type: Shut down overvoltage, re-power on to recover Protection type: Shut down overvoltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-10 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 UL60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
MTBF DIMENSION PACKING
136.8K hrs min. MIL-HDBK-217K (25C) 65.5x125.2x100mm (WxHxD) 0.79Kg; 20pcs / 16.5Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
40
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
100
TB2 1 2 3 4 230VAC
125.2
115VAC
TB1
1 2 3
65.5
LE D
Block Diagram
230 115
RECTIFIERS & FILTER RECTIFIERS & FILTER
I/P
EMI FILTER
POWER SWITCHING
+V -V
FG
Derating Curve
100
28
80
LOAD (%)
60 40
LOAD (%)
24 20 16 12
12V,24V
20
8
-10 0 10 20 30 45 50 60 (VERTICAL)
80 160
85 170
90 180
95 190
100 200
105 210
110 220
115 230
120 240
125 250
130 260
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
41
48V
32
350
HIGH INPUT
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME
PSH-12024
24V 5A 0 ~ 5A 120W 80mVp-p 24 ~ 28V 1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
PSH-12048
48V 2.5A 0 ~ 2.5A 120W 80mVp-p 48 ~ 55V 1.0% 0.5% 0.5% 1000ms, 120ms, 30ms / 500VAC at full load
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
0.5% 0.5% 1700ms, 120ms, 16ms / 400VAC 340 ~ 550VAC 480 ~ 780VDC 47 ~ 63Hz 85% 0.65A / 400VAC 0.6A / 500VAC COLD START 50A 3.5 mA / 530VAC 105 ~ 160% rated output power
INPUT
VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (max.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
86%
PROTECTION
Protection type: Constant current limiting, recovers automatically after fault condition is removed
30 ~ 36V
Protection type: Shut down overvoltage, re-power on to recover
59 ~ 66V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY
-20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL60950-1 approved IEC60950-1 CB approved by SIQ I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55011 (CISPR11); EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
178.7K hrs min. MIL-HDBK-217K (25C) 65.5x125.2x100mm (WxHxD) 0.75Kg; 20pcs / 16Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
42
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
100
TB2 1 2 3 4 125.2 TB1 1 2 3 65.5 LED
1 2 3
Block Diagram
EMI FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL O.V.P.
I/P
POWER SWITCHING
+V -V
FG
Derating Curve
100
80
60 50 40
20
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
43
PSP-240 Series
Specifications
Features:
Universal AC input / full range Built in active PFC function Protections: Short Circuit / Overload / Overvoltage / Over temperature Cooling by free air convection DIN rail mountable UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 100KHz 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
PSP-24024
24V 10A 0 ~ 10A 240W 80mVp-p 24 ~ 28V 1.0%
Tolerance: includes set up tolerance, line regulation and load regulation.
PSP-24048
48V 5A 0 ~ 5A 240W 150mVp-p 48 ~ 53V 1.0% 0.5% 1.0% 800ms, 40ms / 115VAC at full load 24ms / 115VAC at full load 120 ~ 370VDC
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT
Derating may be needed under low input voltages, please check the derating curve for more detail
PROTECTION
OVERLOAD OVERVOLTAGE OVERTEMPERATURE
47 ~ 63Hz 0.96 / 230VAC 0.99 / 115VAC at full load 84% 2.8A / 115VAC; 1.4A / 230VAC COLD START 27A / 115VAC 45A / 230VAC 3.5mA / 240VAC 105 ~ 150% rated output power
85%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
30 ~ 36V
Protection type: Shut down overvoltage, re-power on to recover
54 ~ 60V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -10 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC Compliance to EN55011; EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
MTBF DIMENSION PACKING 289.9K hrs min. MIL-HDBK-217K (25C) 125.5x125.2x100mm (WxHxD) 1.2Kg; 12pcs / 15.5Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
44
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
125.5
100
125.2
TB1 3 2 1
LED
TB2 4 3 2 1
1 2 3
Block Diagram
RECTIFIERS & FILTER CONSTANT CURRENT LIMITING & DETECTION CIRCUIT O.V.P. O.T.P.
I/P
PFC CIRCUIT
POWER SWITCHING
+V -V
FG
O.L.P.
Derating Curve
100
230VAC
90
80
80
60
70
110VAC
40
60 50
20
40
-10 0 10 20 30 40 50 55 60 70 (VERTICAL) Vin: -- 230VAC 110VAC
85
100
110
135
155
230
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
45
POWER SUPPLIES
480W 220V AC Single Output DIN Rail Power Supply with PFC Function
Cat. No. 220V ONLY PSP-48024 PSP-48048 Output V DC A 24V DC 48V DC 20A 10A Tol. % 1% 1% Ripple & Noise 120 mVp-p 120 mVp-p Efficiency 89% 89% NOTES
480W Switch Select 110/220V AC Single Output DIN Rail Power Supply with PFC Function
SWITCH SELECT
110/220V
Cat. No.
Tol. % 1% 1%
NOTES
46
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
SPECIFICATIONS
1 2 3
AC/L AC/N FG
1,2 3,4
DC OUTPUT +V DC OUTPUT -V
12
5.2
22 10 0
Wide range Input: 180-264V AC only, 250-370V DC, 4A @ 230V AC Built in passive Power Factor Correction function compliance to EN61000-3-2, PF>0.7 Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 227x125x100mm (8.95x4.95x3.95 inches) Packaging: 1/box; 5.3lbs / 2.4Kg
1 2 3
AC/L AC/N FG
1,2 3,4
DC OUTPUT +V DC OUTPUT -V
12
5.2
22 10 0
Switch select Input: 90-132V AC / 180-264 V AC, 254-370V DC range 8A @ 115V AC, 3.2A @ 230V AC Built in passive Power Factor Correction function compliance to EN61000-3-2, PF>0.7/230V AC only Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 227x125x100mm (8.95x4.95x3.95 inches) Packaging: 1/box; 5.8lbs / 2.6Kg
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
47
PSP-480 Series
Specifications
220V ONLY
Features:
Built-in passive PFC function compliance to EN61000-3-2 High efficiency 89% and low dissipation Protections: Short Circuit / Overload / Overvoltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
PSP-48024
24V 20A 0 ~ 20A 480W 120mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 1200ms, 40ms / 230VAC at full load 16ms / 230VAC
PSP-48048
48V 10A 0 ~ 10A 480W 120mVp-p 48 ~ 53V 1.0% 0.5% 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
PROTECTION
VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
180 ~ 264 VAC by switch 250 ~ 370VDC 47 ~ 63Hz 0.7 89% 4A / 230VAC COLD START 27A / 115VAC 45A / 230VAC 3.5mA / 240VAC 105 ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
30 ~ 36V
54 ~ 60V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +70C (Refer to output load derating curve) 20 ~ 95% RH non-condensing -20 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55022 (CISPR22); Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-6-2 (EN50082-2); heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
180.9K hrs min. MIL-HDBK-217K (25C) 227x125.2x100mm (WxHxD) 2.4Kg; 6pcs / 15Kg / 1.75CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
48
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
227 100
TB1 3 2 1
LE D
TB2 4 3 2 1
Block Diagram
EMI FILTER PASSIVE PFC RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT PWM CONTROL O.V.P. +V -V
I/P
FG
O.L.P. O.T.P.
Derating Curve
100
80
LOAD (%)
LOAD (%)
80 70 60 50
60 40
20
40 0 10 20 30 40 50 60 70 (VERTICAL)
-20
180
125.2
190
200
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
49
PSP-480S Series
Specifications
SWITCH SELECT
Features:
AC input range selectable by switch Built-in passive PFC function compliance to EN61000-3-2 High efficiency 89% and low dissipation Protections: Short Circuit / Overload / Overvoltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 year warranty
110/220V
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PSP-480S24
24V 20A 0 ~ 20A 480W 120mVp-p 24 ~ 28V 1.0%
PSP-480S48
48V 10A 0 ~ 10A 480W 120mVp-p 48 ~ 55V 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
0.5% 0.5% 1.0% 1.0% 1200ms, 40ms / 230VAC 1200ms, 40ms / 115VAC at full load 23ms / 230VAC 23ms / 115VAC at full load 90 ~ 132VAC / 180 ~ 264 VAC by switch 254 ~ 370VDC 47 ~ 63Hz 0.7 / 230VAC only 89% 8A / 115VAC 3.2A / 230VAC COLD START 27A / 115VAC 45A / 230VAC 3.5mA / 240VAC 105 ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
30 ~ 36V
59 ~ 66V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +70C (Refer to output load derating curve) 20 ~ 95% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 EN60950-1 approved I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25C / 70% RH Compliance to EN55011 (CISPR11); EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2 (EN50082-2); heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
187.9K hrs min. MIL-HDBK-217K (25C) 227x125.2x100mm (WxHxD) 2.6Kg; 6pcs / 16.6Kg / 1.75CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
50
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
227 100
TB1 3 2 1
LE D
TB2 4 3 2 1
Block Diagram
230 115
EMI FILTER PASSIVE PFC RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT PWM CONTROL O.V.P. +V -V
I/P
FG
O.L.P. O.T.P.
Derating Curve
100
80
80
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 70 (VERTICAL)
60 40
70 60 50 40
20
-20
90 180
100 190
115 230
132 264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
51
POWER SUPPLIES
52
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
SPECIFICATIONS
PST-240 Series
TB1 Terminal Pin. No Assignment
Pin No. 1 2 3 4 Assignment FG AC/L3 AC/L2 AC/L1
12
5.2
10
12
5.5
Three phase input: 340-550V AC wide range, 480-780V DC 0.95A @ 400V AC, 0.75A @ 500V AC Connection: Input - 4 poles, Output 4 poles screw terminal Size (WxHxD): 125x125x100mm (4.95x4.95x3.95 inches) Packaging: 1/box; 2.87lbs / 1.3Kg
PST-480 Series
TB1 Terminal Pin. No Assignment
Pin No. 1 2 3 4
12 5.2 27
2 10 0
Three phase input: 340-550V AC wide range, 480-780V DC 1.7A @ 400V AC, 1.3A @ 500V AC Connection: Input - 4 poles, Output 4 poles screw terminal Size (WxHxD): 227x125x100mm (9.95x4.95x3.95 inches) Packaging: 1/box; 5.5lbs / 2.5Kg
PST-960 Series
TB1 Terminal Pin. No Assignment
Pin No. 1 2 3 4
5.2
27 6
Parallel Only
12
10
Three phase input: 340-550V AC wide range, 2.4A @ 400V AC, 1.9A @ 500V AC Connection: Input - 4 poles, Output 6 poles screw terminal Size (WxHxD): 276x125x100mm (10.87x4.95x3.95 inches) Packaging: 1/box; 7.3lbs / 3.3Kg
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
53
PST-240 Series
Specifications
Features:
Three-Phase AC 340 ~ 550V wide range input High efficiency 89% and low dissipation Protections: Short Circuit / Overload / Overvoltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test Fixed switching frequency at 70KHz 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PST-24024
24V 10A 0 ~ 10A 240W 80mVp-p 24 ~ 28V 1.0%
PST-24048
48V 5A 0 ~ 5A 240W 80mVp-p 48 ~ 55V 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
0.5% 0.5% 0.5% 0.5% 1200ms, 40ms, 20ms / 400VAC; 800ms, 40ms, 40ms / 500VAC at full load Three Phase 340 ~ 550VAC (Dual Phase operation possible) Dual phase operation: derating of 20% is required 47 ~ 63Hz 89% 0.95A / 400VAC; 0.75 / 500VAC COLD START 50A 3.5 mA / 530VAC 105 ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
480 ~ 780VDC
PROTECTION
30 ~ 36V
59 ~ 66V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A,
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION EMS IMMUNITY
OTHERS
114.6K hrs min. MIL-HDBK-217K (25C) 125.5x125.2x100mm (WxHxD) 1.3Kg; 12pcs / 16.6Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
54
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
125.5 100
TB1 4 3 2 1
LE D
TB2 4 3 2 1
125.5
Block Diagram
EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL O.V.P. +V -V
I/P
FG
Derating Curve
100
80
80
LOAD (%)
LOAD (%)
60 40
20
-20
10
20
30
40
50
60
70 (VERTICAL)
340
355
370
385
400
415 430
460 475
490
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
55
PST-480 Series
Specifications
Features:
Three-Phase AC 340 ~ 550V wide range input High efficiency 89% and low dissipation Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PST-48024
24V 20A 0 ~ 20A 480W 80mVp-p 24 ~ 28V 1.0%
PST-48048
48V 10A 0 ~ 10A 480W 80mVp-p 48 ~ 55V 1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
0.5% 0.5% 0.5% 0.5% 1200ms, 40ms, 16ms / 400VAC; 800ms, 40ms, 35ms / 500VAC at full load Three Phase 340 ~ 550VAC (Dual Phase operation possible) Dual phase operation: derating of 20% is required 47 ~ 63Hz 89% 90% 1.7A / 400VAC; 1.3A / 500VAC COLD START 50A 3.5mA / 530VAC 105 ~ 150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
480 ~ 780VDC
PROTECTION
30 ~ 36V
59 ~ 66V
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
-20 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C: 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
MTBF DIMENSION PACKING
91.1K hrs min. MIL-HDBK-217K (25C) 227x125.2x100mm (WxHxD) 2.5Kg; 6pcs / 16Kg / 1.75CUFT
All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
56
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
227 100
TB1 4 3 2 1
LED
TB2 4 3 2 1
Block Diagram
EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.L.P. O.T.P. PWM CONTROL O.V.P. +V -V
I/P
FG
Derating Curve
100
125.2
80
LOAD (%)
LOAD (%)
60 40
20
40
-20
10
20
30
40
50
60
70 (VERTICAL)
340
355
370
385
400
415 430
460 475
490
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
57
PST-960 Series
Specifications
Features:
Three-Phase AC 340 ~ 550V wide range input High efficiency 91% and low dissipation Protections: Short Circuit / Overload / Over Voltage / Overtemperature Optional parallel function(1+1) Cooling by free air convection DIN rail mountable UL 508(industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT
PST-96024 / PST-960P24*
24V 40A 0 ~ 40A 960W 80mVp-p
PST-96048 / PST-960P48*
48V 20A 0 ~ 20A 960W 80mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
24 ~ 28V 48 ~ 55V 1.0% 1.0% Tolerance: includes set up tolerance, line regulation and load regulation. 0.5% 0.5% 0.5% 0.5% 200ms, 60ms, 14ms / 400VAC 200ms, 60ms, 30ms / 500VAC at full load Three Phase 340 ~ 550VAC (Dual Phase operation possible in connecting L1, L3, FG)
Dual phase operation (connecting L1, L3, FG) is allowed under certain derating to output load. Please refer to the derating curves for details.
PROTECTION
30 ~ 36V
59 ~ 66V
110C 5C (TSW1) detect on heat sink of power transistor 85C 5C (TSW2) detect on heat sink of power diode Protection type: Shut down overvoltage, recovers automatically after temperature goes down -20 ~ +60C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 approved UL60950-1 I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
122.5K hrs min. MIL-HDBK-217K (25C) 276x125.2x100mm (WxHxD) 3.3Kg; 4pcs / 14.2Kg / 1.14CUFT
All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
Mechanical Specification
276 100
TB1 4 3 2 1
ALARM LE D
TB2 6 5 4 3 2 1
125.2
Parallel Only
PSU
PSU
TB1 4 3 2 1
LED
TB2 8 7 6 5 4 3 2 1
TB1 4 3 2 1
LED
TB2 8 7 6 5 4 3 2 1
+V LOAD
-V
Block Diagram
I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.V.P. +V -V
O.T.P. FG PHASE-SHIFT
Derating Curve
100
80
80
LOAD (%)
LOAD (%)
60 50 40
20
-20
10
20
30
40 45 50
60
70 (VERTICAL)
340
355
380
385
400
415430
460
475 490
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
59
Over temperature protection: Withstand voltage: Working temperature: Safety standards: EMC standards:
60
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
PS-C Series
ENERGY SAVER
Features: High efficiency up to 94% and low power dissipation Universal AC Input / Full Range 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short circuit / Overload / Overvoltage / Over temperature Cooling by free air convection Din rail mountable LED indicator for power on UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test Built-in DC OK relay contact 3 year warranty
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
61
62
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
SPECIFICATIONS
PS-C120 Series
Terminal Pin. No Assign. (TB1)
Pin No. 1 2 3
12 5.2
11
3.5
40
Universal Input: 88-264V AC, 124-370V DC full range, 1.4A/115V AC, 0.7A/230V AC Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 40x125.2x113.5mm (1.57x4.93x4.47 inches) Packaging: 1/box; 1.48lbs / 0.67Kg
PS-C240 Series
Terminal Pin. No Assign. (TB1)
Pin No. 1 2 3
12 5.2
11
3.5
63
Switch select Input: 88-264V AC, 124-370V DC range, 2.6A/115V AC, 1.3A/230V AC Connection: Input - 3 poles, Output 6 poles screw terminal Size (WxHxD): 63x125.2x113.5mm (2.48x4.93x4.47 inches) Packaging: 1/box; 2.27lbs / 1.03Kg
PS-C480 Series
Terminal Pin. No Assign. (TB1)
Pin No. 1 2 3
12 5.2
8.5
85
.5
Pin No. 1 2 3
Universal Input: 90-264V AC, 127-370V DC full range, 5A/115V AC, 2.5A/230V AC Connection: Input - 3 poles, Output 12 poles screw terminal Size (WxHxD): 85.5x125.2x128.5mm (3.37x4.93x5.06 inches) Packaging: 1/box; 3.53lbs / 1.6Kg
Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
63
PS-C120 Series
Specifications
ENERGY SAVER
Features:
High efficiency 91% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2 (EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD
PS-C12012
PS-C12024
PS-C12048
48V 2.5A 0 ~ 2.5A 120W 3.75A
12V 24V 10A 5A 0 ~ 10A 0 ~ 5A 120W 120W 15A 7.5A 180W (3 sec.) 3 seconds max., please refer to peak loading curves 100mVp-p 100mVp-p 12 ~ 14V 1.0% 0.5% 1.0% 1500ms, 60ms / 230VAC 20ms / 230VAC 88 ~ 264VAC 24 ~ 28V 1.0% 0.5% 1.0% 3000ms, 60ms / 115VAC at full load 20ms / 115VAC at full load 124 ~ 370VDC
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
Deating may be needed under low input voltages, please check the derating curve for more detail
PROTECTION
47 ~ 63Hz 0.93 / 230VAC 0.96 / 115VAC at full load 89% 91% 1.4A / 115VAC 0.7A / 230VAC 35A / 115VAC 70A / 230VAC 1 mA / 240VAC
90.50%
OVERVOLTAGE OVERTEMPERATURE
Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage 150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down overvoltage after 3 seconds 14 ~ 17V 29 ~ 33V 56 ~ 65V
Protection type: Shut down overvoltage, re-power on to recover
30VDC / 1A
ENVIRONMENT
WORKING TEMP.
20 ~ 95% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
289.9K hrs min. MIL-HDBK-217K (25C) 40x125.2x113.5mm (WxHxD) 0.67Kg; 20pcs / 14.4Kg / 1.16CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
64 12
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
TB2
40
1 2 3 4
113. 5
+V ADJ.
1 2 3
Assignment 1,2 3 4
125.2
DC OK Relay Contact
age.
Block Diagram
EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.C.P. U.V.P. FG PFC CONTROL O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. +V -V
I/P
Peak Loading
180W 180W
120W
60W
Derating Curve
150
112.5
12V Others
80 70
100
75
Continuous
60
12V
50 40
60
-25
10
20
30
40
50 55 60
70 (VERTICAL)
88
TB1
1 2 3
100
110
135
155
230
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
65 12
PS-C240 Series
Specifications
ENERGY SAVER
Features:
High efficiency 94% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD
PS-C24024
PS-C24048
24V 48V 10A 5A 0 ~ 10A 0 ~ 5A 240W 240W 15A 7.5A 360W (3 sec.) 3 seconds max., please refer to peak loading curves 100mVp-p 120mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
24 ~ 28V 1.0% 0.5% 1.0% 1500ms, 60ms / 230VAC 20ms / 230VAC 88 ~ 264VAC
48 ~ 55V 1.0% 0.5% 1.0% 3000ms, 60ms / 115VAC at full load 20ms / 115VAC at full load 124 ~ 370VDC
INPUT
Deating may be needed under low input voltages, please check the derating curve for more detail
PROTECTION
OVERVOLTAGE OVERTEMPERATURE
47 ~ 63Hz 0.93 / 230VAC 0.99 / 115VAC at full load 94% After 30 minutes of burn-in. 2.6A / 115VAC 1.3A / 230VAC 33A / 115VAC 65A / 230VAC 1 mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery 150% rated power, constant current limiting with autorecovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V
Protection type: Shut down overvoltage with auto-recovery
ENVIRONMENT
DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A 30VDC / 1A 30VAC / 0.5A RESISTIVE LOAD WORKING TEMP. -25 ~ +70C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
20 ~ 95% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
169.3K hrs min. MIL-HDBK-217K (25C) 63x125.2x113.5mm (WxHxD) 1.03Kg; 12pcs / 13.4Kg / 1.06CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
66 12
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
113. 5
Mechanical Specification
TB2 1 2 3 4 5 6
+V ADJ.
+
1 2 3
125.2
1 TB1
63
DC OK Relay Contact
age.
Block Diagram
EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.C.P. U.V.P. FG PFC CONTROL O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. +V -V
I/P
Peak Loading
360W 360W
240W
120W
Derating Curve
150
112.5
80
100
70
75
Continuous
60 50
60
40
-25 0 10 20 30 40 50 60 70 (VERTICAL)
88
100
110
135
155
230
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
67 12
PS-C480 Series
Specifications
ENERGY SAVER
Features:
High efficiency 94% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.94 Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL 508(industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD
PS-C48024
PS-C48048
24V 48V 20A 10A 0 ~ 20A 0 ~ 10A 480W 480W 30A 15A 720W (3 sec.) 3 seconds peak power max. and the average output power should not exceed the rate power 100mVp-p 120mVp-p
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
24 ~ 28V 1.2%
48 ~ 55V 1.0%
INPUT
0.5% 0.5% 1.0% 1.0% 1500ms, 150ms / 230VAC 3000ms, 150ms / 115VAC at full load 14ms / 230VAC at full load 90 ~ 264VAC 127 ~ 370VDC
Deating may be needed under low input voltages, please check the derating curve for more detail
PROTECTION
OVERVOLTAGE OVERTEMPERATURE
5A / 115VAC 2.5A / 230VAC 40A / 115VAC 80A / 230VAC 0.8 mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery 150% rated power, constant current limiting with auto-recovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V
Protection type: Shut down overvoltage with auto-recovery on re-power on to recovery
ENVIRONMENT
DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. -25 ~ +70C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
20 ~ 95% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
112.9K hrs min. MIL-HDBK-217K (25C) 85.5x125.2x128.5mm (WxHxD) 1.6Kg; 8pcs / 13.8Kg / 0.9CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
68 12
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
128.5
TB2 1 2 3 4 5 6 7 8
1 2 3
DC OK Relay Contact
age.
Block Diagram
I/P
& RECTIFIERS
PFC CIRCUIT
POWER SWITCHING
TB1
85.5
125.2
Assignment
+ +V ADJ
NC
+V -V
Peak Loading
720W 720W
480W
240W
Derating Curve
150
120
80
100
70
80
Continuous
60 50
60
40
-25 0 10 20 30 40 50 60 70 (VERTICAL)
90
100
110
135
155
230
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
69 12
PS-C480P Series
With Parallel Function
Features:
High efficiency 94% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.94 Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable Current sharing up to 380W (1+7) UL 508(industrial control equipment)approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
Specifications
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD
PS-C480P24
24V 20A 0 ~ 20A 480W 30A 720W (3 sec.) 100mVp-p 24 ~ 28V 1.2% 0.5% 1.0% 1500ms, 150ms, 14ms / 230VAC 90 ~ 264VAC 47 ~ 63Hz 0.94 / 230VAC 94% 127 ~ 370VDC
PS-C480P48
48V 10A 0 ~ 10A 480W 15A
3 seconds peak power max. and the average output power should not exceed the rate power
120mVp-p 48 ~ 55V 1.0% 0.5% 1.0% 3000ms, 150ms / 115VAC at full load
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
Deating may be needed under low input voltages, please check the derating curve for more detail
PROTECTION
5A / 115VAC 2.5A / 230VAC 40A / 115VAC 80A / 230VAC 0.6 mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down overvoltage with auto-recovery 150% rated power, constant current limiting with auto-recovery within 2 seconds and shut down overvoltage after 2 seconds 29 ~ 33V 56 ~ 65V
Protection type: Shut down overvoltage with auto-recovery on re-power on to recovery
OVERVOLTAGE OVERTEMPERATURE
ENVIRONMENT
CURRENT SHARING Please see function diagram DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY -25 ~ +70C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
20 ~ 95% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 EN60950-1 compliant I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2; (EN50082-2), EN61204-3; heavy industry level; criteria A, SEMI F47, GL approved
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
112.9K hrs min. MIL-HDBK-217K (25C) 85.5x125.2x128.5mm (WxHxD) 1.6Kg; 8pcs / 13.8Kg / 0.9CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
70
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
128.5 85.5
1 2 3 4 5 6 7 8
TB2
DC OK
125.2
DC OK
+
+V A D J
DC OK Relay Contact
Contact Close Contact Open Contact Ratings (max.) When the output voltage reaches the adjusted output volt age. When the output voltage drop below 90% output voltage. 30V/1A resistive load
Peak Loading
(1) 720W (2) 720W
480W
50 sec. 3 sec.
240W
15 sec. 3 sec.
TB1
DC OK
Block Diagram
I/P EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.C.P. U.V.P. FG PFC CONTROL O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. +V -V
Function Diagram
1. Current sharing (1)Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required. (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. (4) In parallel operation 8 units is the maximum, please consult the manufacture for other applications. (5) When in parallel operation, the minimum output load should be greater than 3% of total output load. (Min. load > 3% rated current per unit x number of unit)
LOAD
+ - DC OK P+ P-
+ - DC OK P+ P-
+ - DC OK P+ P-
+ - DC OK P+ P-
+ - DC OK P+ P-
+ - DC OK P+ P -
+ - DCOK P+ P -
+ - DCOK P+ P -
PSU
PSU
PSU
PSU
PSU
PSU
PSU
PSU
Derating Curve
150
120
80 70
100
80
Continuous
60 50
60
40
0 10 20 30 40 50 60 70 (VERTICAL)
-25
90
100
110
135
155
230
264
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
71
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
72 12
PSW Series
YGRENE REVAS
ENERGY SAVER
Single and two phase wide input range 180~550VAC Universal AC Input / Full Range High efficiency up to 93% and low power dissipation Protections: Short circuit / Overload / Overvoltage / Over temperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
Multible output connector for easy wiring Adjustable DC Output Voltage DC on LED signal
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
73 12
ENERGY SAVER
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
74 12
SPECIFICATIONS
PSW-120 Series
)2BT( .ngissA oN .niP lanimreT )1BT( .ngissA oN .niP lanimreT
5.2 12
11 3.5
40
PSW-240 Series
)2BT( .ngissA oN .niP lanimreT )1BT( .ngissA oN .niP lanimreT
5.2 12
11 3.5
63
PSW-480 Series
5.5 8 2 5.8 1 2.5 21
12 8.5
5.5
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
tnemngissA .oN niP tcatnoC yaleR 2,1 V- TUPTUO CD 4,3 V+ TUPTUO CD 6,5
tnemngissA .oN niP V+ TUPTUO CD 2,1 V- TUPTUO CD 4,3 tcatnoC yaleR 6,5
tnemngissA .oN niP V+ TUPTUO CD 2,1 V- TUPTUO CD 4,3 tcatnoC yaleR 6,5
36
04
11 5.3
1 5.3
2.5 21
1 2.5 21
Universal Input: 180-550V AC, 254-780V DC full range, 0.55A/400V AC, 1.2A/230V AC Connection: Input - 3 poles, Output 4 poles screw terminal Size (WxHxD): 40x125.2x113.5mm (1.57x4.93x4.47 inches) Packaging: 1/box; 1.433lbs / 0.65Kg
Universal Input: 180-550V AC, 254-780V DC full range, 1A/400V AC, 2A/230V AC Connection: Input - 3 poles, Output 6 poles screw terminal Size (WxHxD): 63x125.2x113.5mm (2.48x4.93x4.47 inches) Packaging: 1/box; 2.337lbs / 1.06Kg
Pin No. 1 2 3
Pin No. 1 2 3
Universal Input: 180-550V AC, 254-780V DC full range, 1.6A/400V AC, 4A/230V AC Connection: Input - 3 poles, Output 12 poles screw terminal Size (WxHxD): 85.5x125.2x128.5mm (3.37x4.93x5.06 inches) Packaging: 1/box; 3.748lbs / 1.7Kg
75 12
PSW-120 Series
Specifications
YGRENE REVAS
Features:
Single and two phase wide input range 180 ~ 550VAC Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection Built-in constant current limiting circuit DIN rail mountable UL508 (industrial control equipment) approved EN61000-6-2 (EN50082-2) industrial immunity level 100% full load burn-in test Built-in DC OK relay contact 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE HOLD UP TIME
PSW-12012
12V 10A 0 ~ 10A 120W 120mVp-p 12 ~ 15V 1.5% 0.5% 0.5% 2000ms, 70ms, 50ms / 400VAC
PSW-12024
24V 5A 0 ~ 5A 120W 120mVp-p 24 ~ 29V 1.0%
PSW-12048
48V 2.5A 0 ~ 2.5A 120W 150mVp-p 48 ~ 58V 1.0%
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
0.5% 0.5% 0.5% 0.5% 2000ms, 70ms, 10ms / 230VAC at full load
Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quick may lead to increase of the set up time.
INPUT
VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE OVERTEMPERATURE
PROTECTION
180 ~ 550VAC 254 ~ 780VDC 47 ~ 63Hz 89.5% / 400V 91% / 400V 0.55A / 400VAC 1.2A / 230VAC COLD START 50A 3.5 mA / 530VAC 105 ~ 130% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
92% / 400V
16 ~ 18V
31 ~ 37V
60 ~ 67V
105C 5C (12V), 110C 5C (24V) (TSW1) detect on heat sink of power switch transistor; 100C 5C (48V) (TSW1) detect on heat sink of power diode
Protection type: Shut down overvoltage, re-power automatically after temperature goes down
ENVIRONMENT
DC OK SIGNNAL WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS
Relay contact rating (max.): 30V / 1A resistive -25 ~ +70C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Mounting clip: Compliance to IEC60068-2-6
UL508 approved IEC60950-1 compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC (25C; 70% RH) EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN61204-3; EN61000-6-2; (EN50082-2), heavy industry level; criteria A,
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
MTBF DIMENSION PACKING
268K hrs min. MIL-HDBK-217K (25C) 40x125.2x113.5mm (WxHxD) 0.65Kg; 20pcs / 14Kg / 1.16CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature.
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
76
2.521
1 2 3
1 2 3 4
2BT
1BT
Mechanical Specification
113. 5
1 2 3 4
DC OK +V ADJ. DC OK
125.2
1 2 3
40
TB1
TB2
+
Block Diagram
RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT CURRENT LIMIT O.L.P. PWM CONTROL O.T.P. O.V.P.
Derating Curve
100
055 025
005
094 054
KO CD
V+ V-
004
063013
) 2 B T ( t n e m n g i s s A . o N n i P a n i m r eT l
scitsiretcarahC citatS
092
052
NOITCETED TIUCRIC
SREIFITCER & R E TL I F
TNERRUC TIMIL
002
.P .V . O
.P .T . O
091
081
5 .311
001
04
05
06
07
08
09
REWOP GNIHCTIWS
) 1 B T ( t n e m n g i s s A . o N n i P a n i m r eT l
) L A C I TR E V ( 0 7
MWP LORTNOC
srehtO
06
+
SREIFITCER & R E TL I F
.P . L . O
KO CD .JDA V+
KO CD
04
05
V21
.oN niP 1 2 3
04
03
noitacificepS lacinahceM
IME R E TL I F
02
01
evruC gnitareD
margaiD kcolB
P/I
GF
52001 02 04 06 08
DC OK
I/P
EMI FILTER
POWER SWITCHING
+V -V
FG
Static Characteristics
Others
100 90
80
80
60 40
12V
70 60 50
20
40
-25
10
20
30
40
50
60
70 (VERTICAL)
180
190
200
250
290
310360
400
450 490
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
77
PSW-240 Series
Specifications
YGRENE REVAS
Features:
Single and two phase wide input range 180~550VAC High efficiency 91% and low power dissipation Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable UL 508 (industrial control equipment) approved EN61000-6-2 (EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE
PSW-24024
24V 10A 0 ~ 10A 240W 150mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 800ms, 150ms, 18ms / 400VAC 180 ~ 550VAC 47 ~ 63Hz 91% 1A / 400VAC COLD START 50A 3.5 mA / 530VAC 254 ~ 780VDC
PSW-24048
48V 5A 0 ~ 5A 240W 150mVp-p 48 ~ 55V 1.0% 0.5% 1.0% 1500ms, 150ms, 18ms / 230VAC at full load
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
Derating may be needed under low input voltage. Please check the derating curve for more details
2A / 230VAC
PROTECTION
29 ~ 33V
56 ~ 65V
Protection type: Shut down overvoltage, re-power on to recovery Under over-voltage condition, If input voltage 200VAC, the power supply will shut down and then may have auto-recovery after several seconds
OVERTEMPERATURE
ENVIRONMENT
90C 5C (TSW) detect on heat sink of power switch Protection type: Shut down overvoltage, recovers automatically after temperature goes down DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS -30 ~ +70C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
20 ~ 95% RH non-condensing -40 ~ +85C; 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 approved IEC 60950-1 compliant Design refer to GL I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG :0.5KVAC O/P-DC OK: 0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) EN55022 (CISPR22), Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN 55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A approved;
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
141.1K hrs min. MIL-HDBK-217K (25C) 63x125.2x113.5mm (WxHxD) 1.06Kg; 12pcs / 13.7Kg / 1.06CUFT
All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
78
1BT
2.521
2BT
1 2 3 4 5 6
Mechanical Specification
1 2 3 4 5 6
TB2
125.2
TB1
63
1 2 3
Block Diagram
DC OK Relay Contact
Derating Curve
100
5 .311
.JDA V+
055
V+ V-
005
054
NOITCETED TIUCRIC
.P . C . O
004
.P .V . O
003
SREIFITCER & R E TL I F
tnemngissA
002
081 001 09 05 06 07 08 04
REWOP GNIHCTIWS
) L A C I TR E V 0 7 (
.P . L . O
06
36
05
.P .V . U
04
1 2 3
CFP LORTNOC
CFP TIUCRIC
03
02
noitacificepS lacinahceM
01
tcatnoC yaleR KO CD
evruC gnitareD
margaiD kcolB
03001 02 04 06 08
P/I
GF
113. 5
+V ADJ.
I/P
PFC CIRCUIT
POWER SWITCHING
+V -V
DETECTION CIRCUIT
O.V.P.
80
80
60
70 60 50
40
20
40
-30 0 10 20 30 40 50 60 70 (VERTICAL)
180
200
300
400
450
500
550
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
79
PSW-480 Series
Specifications
YGRENE REVAS
Features:
Single and two phase wide input range 180~550VAC High efficiency 93% and low power dissipation Protections: Short Circuit / Overload / Over Voltage / Overtemperature Cooling by free air convection DIN rail mountable UL 508(industrial control equipment) approved EN61000-6-2 (EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 year warranty
ENERGY SAVER
OUTPUT
Cat. No.
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD UP TIME VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD OVERVOLTAGE
PSW-48024
24V 20A 0 ~ 20A 480W 100mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 800ms, 150ms, 18ms / 400VAC 180 ~ 550VAC 47 ~ 63Hz 92% 1.6A / 400VAC COLD START 50A 3.5 mA / 530VAC 254 ~ 780VDC
PSW-48048
48V 10A 0 ~ 10A 480W 150mVp-p 48 ~ 55V 1.0% 0.5% 1.0% 2000ms, 150ms, 16ms / 230VAC at full load
TNEMNORIVNE
NOITCETORP
SREHTO
TUPTUO TUPNI
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
INPUT
Derating may be needed under low input voltage. Please check the derating curve for more details
93% 4A / 230VAC
PROTECTION
29 ~ 33V
56 ~ 65V
Protection type: Shut down overvoltage; auto recovery after 1 minute if the fault condition is removed Under over-voltage condition, If input voltage 200VAC, the power supply will shut down and then may have auto-recovery after several seconds.
OVERTEMPERATURE
ENVIRONMENT
DC OK RELAY CONTACT RATINGS (max.) 60VDC / 0.3A; 30VDC / 1A; 30VAC / 0.5A resistive load WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING SAFETY STANDARDS -30 ~ +70C (Refer to output load derating curve)
Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
20 ~ 95% RH non-condensing -40 ~ +85C; 10 ~ 95% RH 0.03% / C (0 ~ 50C) 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 UL508 approved IEC 60950-1 compliant Design refer to GL I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25C; 70% RH) EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN 55024; EN61000-6-2; (EN50082-2); EN61204-3; heavy industry level; criteria A approved;
The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives.
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY
OTHERS
112.8K hrs min. MIL-HDBK-217K (25C) 85.5x125.2x128.5mm (WxHxD) 1.7Kg; 8pcs / 14.6Kg / 0.9CUFT
All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
80
1BT
2.521
2BT
1 2 3 4 5 6
125.2
TB2
1 2 3 4 5 6
TB1
85.5
V+ V-
055
005
054
NOITCETED TIUCRIC
.P . C . O
004
.P .V . O
003
SREIFITCER & R E TL I F
002
tnemngissA
081
5.821
001
05
06
07
08
09
04
REWOP GNIHCTIWS
) L A C I TR E V (
07
.P . L . O
06
5.58
JDA V+ +
05
.P .V . U
04
CFP LORTNOC
1 2 3
CFP TIUCRIC
03
noitacificepS lacinahceM
02
tcatnoC yaleR KO CD
01
evruC gnitareD
margaiD kcolB
03001 02 04 06 08
P/I
GF
Mechanical Specification
128.5
+ +V ADJ
1 2 3
Block Diagram
EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.C.P. U.V.P. O.L.P. DETECTION CIRCUIT O.V.P. +V -V
I/P
DC OK Relay Contact
Derating Curve
100
80
80
60
70 60 50
40
20
40
-30 0 10 20 30 40 50 60 70 (VERTICAL)
180
200
300
400
450
500
550
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
81
Accessories
Power Supply Redundancy Buffer Module PS-RDN20 is a 20A redundancy (decoupling) module for the 24V DC power system. Containing 2 sets of 20A Or-ing diodes with wonderful heat dissipation deployment, PS-RDN20 give you a new option for safe connection of 1+1 redundant set-up. Not only perfectly decouple power sources from each other as well as from the load, PS-RDN20 also provides users monitoring signals for both input channels through the built-in relays. Since theres no switching components inside the module, PS-RDN20 will not arise additional EMI issues and should provide you a worry-free application platform! DC input voltage range Reverse voltage DC output current DC output voltage drop Input voltage alarm Relay contact rating Working Temperature EMC standards Connection 21~28V, 20A max. x 2 channels 30V 20A max. 0.5V max. When input is > 20V(5%) or <30V(5%), relay contacts 30VDC, 1A -20~+70C EN55022 class B, EN61000-4-2,3,4,5,6,8, ENV50204 I/P: 4 poles, O/P: 2 poles screw DIN terminal, Single output: 4 poles
UPS Battery Module PS-UPS40 is a 40A max. DC UPS (battery control) module for the 24 V DC power system. Accompany with external batteries, it can back-up up to 40A of current to critical loads for certain period of time depending on the capacity of batteries. With complete monitoring signals and LED indicators for DC BUS OK, Battery Fail, Battery Discharge and the repeated Battery Test function to check the situation of external batteries. Users can customize their own DC UPS system to back up critical loads and capture the status of the whole system easily. DC input / DC bus Battery inout voltage Battery input current Charge current (typ.) External battery (typ.) DC bus ok Battery fail 24~29V, 40A max. 21~29V 0~40A 2A 24V, 4AH / 7AH / 12AH Relay status: Short when DC voltage between 21~29V(3%), relay contacts Relay status: Short when battery failure is observed through the battery test function, relay contacts LED (red): Battery over-discharge warning or battery broken: light; battery OK: dark Relay status: Short when battery in discharge condition, relay contacts LED (yellow): Battery discharging: light; battery is not discharging or discharging current <2A: dark -20~+70C EN55022 class B, EN61000-4-2,3,4,5,6,8, ENV50204 I/P: 2 poles, O/P: 2 poles screw DIN terminal, Single output: 6 poles
Battery discharge
82
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Alarm A and B Relay Contact LED indicator for input failure alarm (or DC BUS OK) Easy to understand layout panel CE Compliance
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
83
Accessories
Connection: Terminal 1 - 4 poles, Terminal 2 - 6 poles Size (WxHxD): 55.5x125x100mm (2.19x4.95x3.95 inches) Packaging: 1/box; 1.1lbs / 0.5Kg
DC Fail Block Diagram
Connection: Terminal 1 - 4 poles, Terminal 2 - 6 poles Size (WxHxD): 55.5x125x100mm (2.19x4.95x3.95 inches) Packaging: 1/box; 1.21lbs / 0.55Kg
84
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Derating Curve
100
80
LOAD (%)
60 40
12
5.2
1 2 3 4
20
Alarm A1 Alarm A2
-10
10
20
30
40
50
60
70 (VERTICAL)
Applications:
PS U
..............
Vin A Vin A
Vout
PS-UPS40 Series
Terminal Pin. No Assign. (TB1)
1 2 3 4
12 5.2
Derating Curve
100
80
LOAD (%)
60 40
20
10
55
.5
-10
10
20
30
40
50
60
70 (VERTICAL)
PS-UPS40
PS-RDN20
24V Battery
Load
24V Battery
+
BAT DC - - +
Vout
PSU
+ - - - B+ A+ +
Vin
Load
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
85
PS-RDN20
Specifications
Features:
Suitable for redundant operation of 24V system Installed on DIN Rail TS35 / 7.5 or 15 Relay contact signal output and LED indicator for input failure alarm Cooling by free air convection 3 year warranty
OUTPUT
Cat. No.
REVERSE VOLTAGE (max.) OUTPUT CURRENT (max.) VOLTAGE DROP LED INDICATORS
PS-RDN20
30V 20A 0.5V Two green LEDs indicating each input is OK or fail
INPUT
INPUT VOLTAGE RANGE NUMBER OF INPUTS INPUT CURRENT (max.) 21 ~ 28V Two 20A per input When input is 20V (5%) or 30V (5%) relay contacts 30VDC, 1A
FUNCTION
INPUT VOLTAGE ALARM RELAY CONTACT RATING (max.)
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION MOUNTING -20 ~ +70C 20 ~ 90% RH non-condensing -40 ~ +85C, 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6
OTHERS
MTBF DIMENSION PACKING 996.8Khrs min. MIL-HDBK-217K (25C) 55.5x125.2x100mm (WxHxD) 0.5Kg; 20pcs / 11Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at 24V DC input, rated load and 25C of ambient temperature.
86
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
100
LED 125.2
Terminal Pin. No Assignment (TB1) Pin No. Assignment Vout+ 1 Vout2 Vin3,4 5 Vin B+ Vin A+ 6
1 2 3 4 5 6
55. 5
TB1
TB2
1 2 3 4
Terminal Pin. No Assignment (TB2) Pin No. Assignment Alarm B1 1 Alarm B2 2 Alarm A1 3 Alarm A2 4
Block Diagram
Vout+ Vin/VoutRELAY B + RELAY A Vin A+ Alarm A +
Derating Curve
100
80
60 40
20
-20
10
20
30
45
50
60
70
(VERTICAL)
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
87
PS-UPS40
Specifications
Features:
Battery controller for DIN Rail UPS system Parallel connection to DC BUS Suitable for 24V system up to 40A Installed on DIN Rail TS35/ 7.5 or 15 Built-in battery test function Battery polarity protection Relay contact signal output and LED indicator for DC BUS OK, Battery fail, and battery discharge Cooling by free air convection 3 year warranty
Cat. No.
DC VOLTAGE (Typ.) RATED CURRENT
PS-UPS40
24 ~ 29V 40A
VOLTAGE RANGE (Typ.) CURRENT RANGE CHARGE CURRENT (Typ.) EXTERNAL BATTERY (Typ.)
FUNCTION
30VDC, 1A Relay contact: Short when DC voltage between 21 ~ 29V (3%), relay contacts LED (Green): DC BUS OK: light; DC BUS fail: dark Relay contact: Short when battery failure is observed through the battery test function, relay contacts LED (Red): Battery over- discharge warning or battery broken: light; Battery OK: dark
Every 25 seconds, unit will send out test signal through Battery Fail relay contact and LED indicator once the battery is fail.
BATTERY DISCHARGE
Relay contact: Short when battery in discharge condition, relay contacts LED (Yellow): Battery discharging: light; Battery is not discharging or discharging current 2.0A: dark
ENVIRONMENT
-20 ~ +70C 20 ~ 90% RH -20 ~ +85C, 10 ~ 95% RH 10 ~ 500Hz, 2G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6
OTHERS
MTBF DIMENSION PACKING 161.9Khrs min. MIL-HDBK-217K (25C) 55.5x125.2x100mm (WxHxD) 0.55Kg; 20pcs / 12Kg / 1.29CUFT
All parameters NOT specially mentioned are measured at rated load and 25C of ambient temperature.
88
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Mechanical Specification
55. 5 100
125.2
LED 1 2 TB1 3
TB2
Terminal Pin. No Assignment (TB1) Pin No. Assignment BATTERY INPUT + 1 BATTERY INPUT 2 3 DC INPUT 4 DC INPUT +
1 2 3 4 5 6
Terminal Pin. No Assignment (TB2) Pin No. Assignment BAT DISC 1 1 BAT DISC 2 2 BAT OK 1 3 BAT OK 2 4 DC OK 1 5 DC OK 2 6
Block Diagram
LOAD + BAT. TEST 25Ax2 + CHARGE CIRCUIT LIMIT
24V BATTERY
DETECTION CIRCUIT
DISCHARGE
Derating Curve
100
80
60 40
20
-20
10
20
30
45
50
60
70
(VERTICAL)
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com
89
Accessories
POWER SUPPLIES
DIN MOUNTING RAILS
Altech DIN Rails comply with DIN 50045, 50022 and 50035 Standards. The use of DIN Rails enhances design capabilities, saves space and reduces labor. Standard rails are made of steel with zinc plating and chromate passivation and are available in various configurations. DIN Rails are 35mm wide and available in 7.5 and 15mm depths. They are supplied in 1 m (3'3") and 2 m (66) lengths. Upon request they can be cut to custom lengths and punched with holes or perforations. DIN35 DIN35
(7.5 mm deep) Type Perforated Steel Cat. No. 2511120 2511120/1M 2511110 2511110/1M Length Std. Pk. 2m 1m 2m 1m 20 40 20 40 Type Perforated Steel Cat. No. CA701-15/S-2M CA701-15/S CA701-15-2M CA701-15
Unperforated Steel
Unperforated Steel
SUPPORT BRACKETS
Support Brackets elevate DIN Rails away from the panel to facilitate component mounting and to increase wiring access. Angled brackets tilt the rail by 45 to improve visibility. Straight brackets are available in three heights for optimum positioning of the rail. Brackets mount with 2 screws to any panel or flat surface and have tapped center holes for rail mounting. Bracket material is steel, zinc plated yellow chromate.
DIN35
DIN35
Std. Pk. 25
Height 1 2 3
Std. Pk. 25 25 25
90
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
CA202
CA802
CA302
CA402
CASP
15.960
AEx eII EEx eII Terminal Width Height x Length Stripping Length Insulation Material Type of Connection Approvals
C US C US C US
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
91
92
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Why I cannot turn on the power supply smoothly when the loads are motors, light bulbs or capacitive loads? If you connect the switching power supply to motors, light bulbs, or high capacitive loads, you will have a high output surge current when you turn on the S.P.S. and this high surge current will cause failure of start up. We suggest using switching power supply with over load protection and constant current limiting protection to deal with these loads. Why did the power supply shuts down during operation and after turning it off, I can restart the power supply again? In general there are two circumstances that will cause the power supply to shut down. The first one is the activation of the over-load-protection (OLP). To deal with this situation, we suggest increasing the rating of the output power or modifying the OLP point. The second one is the activation of over-temperature protection (OTP) when the internal temperature reaches the pre-set value. All of these conditions will let the switching power supply enter protection mode and shut down. After these conditions are removed, the switching power supply will be back to normal. The output ground (GND) and frame ground (FG) is the same point in my system, can ALTECH's power supplies be used in such system? Yes. Since our products are designed based on isolation concept, it will be no problem that the output ground (GND) and frame ground (FG) is the same point in your system. But, EMI may be affect by this connection. During the operation of ALTECH power supply, there is some leakage current on the case. Is this normal? Will this leakage current hurt human body? Due to the requirement of EMI, there will be some Y capacitors between line and neutral to the FG (case) to improve EMC. These Y capacitors will cause some leakage current flow from line or neutral to the case (normally case will be connected to earth ground). For example, IEC-60950-1 requires that this current should be less than 3.5mA for IT equipment, so basically the leakage current you find on the case will not hurt human body. Proper connection to Earth ground will solve the leakage current problem. What should be noticed when installing a power supply in vertical and horizontal directions? Most small wattage power supplies are mainly installed in the horizontal position. If you have to install it vertically because of mechanical limitation, you should consider the output derating due to the heat concern. The temperature derating curve can be found on the spec sheet. What is "Input - Inrush Current"? What will we notice? At input side, there will be (1/2 ~1 cycle, ex. 1/120 ~ 1/60 seconds for 60 Hz AC source) large pulse current (20~60A based on the design of S.P.S.) at the moment of power on and then back to normal rating. This "Inrush Current" will appear every time you turn on the power. Although it will not damage the power supply, we suggest not turning the power supply ON/OFF very quickly within a short time. Besides, if there are several power supplies turning on at the same time, the circuit breaker of AC source may shut off and go into protection mode because of the huge inrush current. It is suggested that these power supplies start up one by one if possible. What is PFC? PFC stands for Power Factor Correction. The purpose of PFC is to improve the ratio of apparent power and real power. The power factor is only 0.4~0.6 in non-PFC models. In PFC models, the power factor can reach above 0.95. The calculation formulas are as below: Apparent Power=Input Voltage x Input Current (VA) Real Power= Input Voltage x Input Current x Power Factor (W) From the environment friendly point, the electric power plant needs to generate a power which is higher than apparent power in order to steadily provide electricity to the market. The real usage of electricity should be defined by real power. Assuming the power factor is 0.5, the power plant needs to produce more than 2VA to satisfy 1W real power. On the contrary, if the power factor is 0.95, the power plant only needs to generate more than 1.06VA to provide 1W real power need. It will be more effective. What is the difference between -V, +V and COM which are marked on the output side? COM(COMMON) means common ground. Single output: Positive pole (+V), Negative pole (-V) +V; COM and V can be attained by using two switching power supplies in series. Example: (2x PS-S2012) + +
In ALTECH's catalog, we see AC and DC at input, what is it all about? Due to different circuit designs, ALTECH power supply's input consists of three types as below: (2=1,414 1.414 x AC = DC) +12V COM -12V A.85~264VAC;120~370VDC B.176~264VAC;250~370VDC C.85~132VAC/176~264VAC by Switch; 250~370VDC In the case of option A and B inputs models, power supply can work properly no matter under AC or DC input. Some models need correct connection of input poles, positive pole connects to AC/L; negative pole connects to AC/N. Others may require opposite connection, positive pole to AC/N; negative pole to AC/L. If customers make a wrong connection, the power supply will not be broken. You can just reverse the input poles and power supply will still work. In the case of option C input models, please make sure that you switch the 115/230V input correctly. If the switch is on the 115V side and the real input is 230V, the power supply will be damaged.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com
93
Subjects Creepage distance/ Clearance distance Working Voltage: Max. 250Vrms Electric Strength Test
IEC60950-1 Basic Insulation Supplementary Insulation Basic Insulation Supplementary Insulation 2.5mm/2mm 5mm/4mm 1500Vac 3000Vac Handheld: 0.75mA CLASS I
IEC60601-1 4mm/2.5mm 8mm/5mm 1500Vac 4000Vac Leakage current of grounding Leakage current of grounding Leakage current of grounding 2 40C 0.3mA 0.1mA 0.1mA
Others: 3.5mA
What is MTBF? Is it different from Life Cycle? MTBF and Life Cycle are both indicators of reliability. Altech uses MIL-HDBK-217F as the core of MTBF. An expected reliability is forecasted through accounting component's number. The exact meaning of MTBF is after continuously using of power supply in a certain time, the probability of operating properly is 36.8%e-1=0.368). If power supply is continuously used at double the MTBF time, the probability of operating properly becomes 13.5%e-2=0.135). Life Cycle is found through using the temperature rise of electrolytic capacitor to estimate the approximate life of power supply. For example, PS-S10 series MTBF=584K hours; electrolytic capacitor C108 Life Cycle=202K hours (Ta=45 C).
POWER SUPPLY LEGAL DISCLAIMER Power supply data sheet specifies devices but can not promise to deliver any specific characteristics. No warranty or guaranty is given regarding performance or suitability. The customer shall test and ensure that each power supply would work for the anticipated use. Altech Corp. reserves the right to make modification to its power supply data sheets or specifications at any time without prior notice. Please visit www.altechcorp.com/power for more information.
94
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Selection Guide
U ni ve r Sw sal itc Inp u h U Se t L 50 lec U 8 L t In L 60 iste put d N 950 EC -1 C Cla Rec E . m ss ar 2 C R oh ked om s pl R Co ia ea nt m ch p D C lian C om t O pl Sh K ia nt or t O Cir ve c rlo uit ad O ve r O Vol ve ta ge r EM Tem pe C ra C tu B re
Output voltage
5 PS-S10xx PS-S20xx PS-S40xx PS-S60xx PS-S100xx PS-15xx PS-30xx PS-45xx PS-60xx PS-100xx PS-75xx PS-120xx PSH-120xx PSP-240xx PSP-480xx PSP-480Sxx PST-240xx PST-480xx PST-960xx PST-960Pxx PS-C120xx PS-C240xx PS-C480xx PS-C480Pxx PSW-120xx PSW-240xx PSW-480xx PS-RDN PS-UPS
TP = three phase input WR = wide range input
12 X X X X X X X X X X X X
15 24 48 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X
X X X X X X X X X X X X X X V X TP TP TP TP X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X* X* X*
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X
X X 21-28 21-28
X X X
X WR X WR X WR
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
95
Index
Part No. Page
32 32 32 40 40 40 24 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 38 38 38 64 64 64 66 66 68 68 70 70 86 18 18 18 10 10 10 10 12 12 12 12 14 14 14 14
Part No.
Page
PS-10012 .........................................22, PS-10015 .........................................22, PS-10024 .........................................22, PS-12012 .........................................36, PS-12024 .........................................36, PS-12048 .........................................36, PS-1505 ...........................................22, PS-1512 ...........................................22, PS-1515 ...........................................22, PS-1524 ...........................................22, PS-3005 ...........................................22, PS-3012 ...........................................22, PS-3015 ...........................................22, PS-3024 ...........................................22, PS-4505 ...........................................22, PS-4512 ...........................................22, PS-4515 ...........................................22, PS-4524 ...........................................22, PS-6005 ...........................................22, PS-6012 ...........................................22, PS-6015 ...........................................22, PS-6024 ...........................................22, PS-7512 ...........................................36, PS-7524 ...........................................36, PS-7548 ...........................................36, PS-C12012 ......................................62, PS-C12024 ......................................62, PS-C12048 ......................................62, PS-C24024 ......................................62, PS-C24048 ......................................62, PS-C48024 ......................................62, PS-C48048 ......................................62, PS-C480P24 ....................................62, PS-C480P48 ....................................62, PS-RDN20 .......................................84, PS-S10012.........................................8, PS-S10024.........................................8, PS-S10048.........................................8, PS-S1005...........................................8, PS-S1012...........................................8, PS-S1015...........................................8, PS-S1024...........................................8, PS-S2005...........................................8, PS-S2012...........................................8, PS-S2015...........................................8, PS-S2024...........................................8, PS-S4005...........................................8, PS-S4012...........................................8, PS-S4024...........................................8, PS-S4048...........................................8,
PS-S6005...........................................8, 16 PS-S6012...........................................8, 16 PS-S6024...........................................8, 16 PS-S6048...........................................8, 16 PS-UPS40........................................84, 88 PSH-12024 ......................................36, 42 PSH-12048 ......................................36, 42 PSP-24024.......................................36, 44 PSP-24048.......................................36, 44 PSP-48024.......................................46, 48 PSP-48048.......................................46, 48 PSP-480S24 ....................................46, 50 PSP-480S48 ....................................46, 50 PST-24024 .......................................52, 54 PST-24048 .......................................52, 54 PST-48024 .......................................52, 56 PST-48048 .......................................52, 56 PST-96024 .......................................52, 58 PST-96048 .......................................52, 58 PST-960P24 .....................................52, 58 PST-960P48 .....................................52, 58 PSW-12012......................................74, 76 PSW-12024......................................74, 76 PSW-12048......................................74, 76 PSW-24024......................................74, 78 PSW-24048......................................74, 78 PSW-48024......................................74, 80 PSW-48048......................................74, 80 Accessories: 15.960 ....................................................91 2511110 .................................................90 2511110/1M...........................................90 2511120 .................................................90 2511120/1M...........................................90 CA202 ....................................................91 CA302 ....................................................91 CA402 ....................................................91 CA603 ....................................................90 CA701-15...............................................90 CA701-15-2M ........................................90 CA701-15/S ...........................................90 CA701-15/S-2M.....................................90 CA703 ....................................................90 CA802 ....................................................91 CA803 ....................................................90 CA903 ....................................................90 CASP .....................................................91 CGT10U .................................................91 CGT4N ...................................................91 CGT6N ...................................................91
96
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.
Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490
97