Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Gas Generators: Re Gen

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

®

ULTRA HIGH PURE


GAS GENERATORS
FOR ANALYTICAL INSTRUMENT

re Gen
TM

Precision Laboratory Gas Generators

www.pcianalytics.in ISO 45001:2018


www.pcigenerator.com CERTIFIED
PCI Analytics, an ISO 9001:2015 certified company has long history of manufacturing Laboratory Ultrapure
Gas Generators for Gas Chromatography, LCMS/MS & other Laboratory Analytical Applications LCMS/MS in
India with installation base of over 4500 Gas Generators PAN India & Worldwide.

2022

2021

re Gen
TM

Precision Laboratory Gas Generators

2020

2019

2018

2014

2011

2007

2004

2001
Zero Air Generator for GC/TOC (Online/Offline)
Zero Air Generator produces a continuous flow of high
purity Zero Air at selected pressure
For TOC Analyzer, compressor takes the air from atmosphere,
the hot air is then passed through copper cooling coil
The cool air is then passed through furnace where hydrocarbons
are cracked at high temperature (temp. range 300°C to 400°C) in
presence of catalyst. The furnace reaction at higher temperature
breaks the hydrocarbon into CO & H₂O
Water is drained away through 5μ & 0.01μ filter
The modular pressure swing adsorption (PSA) unit operates with
alternating pressure increase and decrease.
Air flows under pressure through the reaction towers containing
molecular sieve adsorber.
Moisture, CO, CO₂ , HC and other unwanted components in the
air are adsorbed, leaving Zero Air Gas.

Model : ZAG-02/03

Salient Features Schematic Diagram of Zero Air Generator


Micro controller digital display
Deliver constant pressure & flow Purge line
NRV
Fully Automatic System
Easy Maintenance and space saving Solenoid
valve
Effortless and easy operation
Improves instrument performance Adsorbent tower Storage tank
Fully regenerative, durability with PSA technology
Cooling coil
Pressure / flow
Applications controller

GC-FID, FPD, NPD, AED Solenoid


inlet
GC-MS, LC-MS-MS, ICP / NMR Air
Inlet
valve
Solenoid
FTIR / IR, ELSD detector exhaust Dust filter
valves
Purging, Ampule Filling Compressed
air filter Vent Vent
Thermal instruments
Analytical & Laboratory Instruments

Technical Specification for Zero Air Generator


ZAG02 ZAG03
PRINCIPLE SPECIFICATIONS
(for max. 5 GC's) (for TOC Analyser)
Moisture < 5 ppm < 0.3 ppm
Total Hydro Carbon < 0.3 ppm < 0.5 ppm
CO & CO < 2 ppm < 0.2 ppm
Purity UHP grade TOC/XL grade
Micro Particulates < 0.01μ < 0.01μ
Capacity of ZAG upto 4 LPM at 80 Psi 500ml/min at 80 Psi
Method of purification Pressure Swing Adsorption Pressure Swing Adsorption
(PSA) (PSA) & HC Cracking furnace
Room temperature 10 °C to 25°C 5 °C to 25°C
Start up time 5 minutes 30 minutes
Electrical requirements for ZAG 230 VAC, 50 Hz, 1 ph 230 VAC, 50 Hz, 1 ph, 5 Amp
Dimension (in mm) 400H x 600W x 600D 600H x 400W x 600D
Net weight 55 kg. (approx) 55 kg. (approx)
Gas Outlet Port 1/8" OD 1/8" OD

01
Nitrogen Generator for GC Model : NG-02/NG-02(A) / NG-02(M)
Schematic Diagram of Nitrogen Generator

Purge line
NRV

Solenoid
valve

Adsorbent tower Storage tank

Cooling coil
Pressure / flow
controller

Solenoid
inlet
Air valve
Inlet Solenoid
exhaust Dust filter
Compressed valves
air filter Vent Vent

Model : NG-02 / NG-02(A) / NG-02(M)

Nitrogen Generator produces a continuous flow of high purity Nitrogen at selected pressure.
The modular Pressure Swing Adsorption (PSA) unit operates with alternating pressure increase and decrease.
Untreated air flows under pressure through the reaction towers containing carbon molecular sieves adsorber. Moisture,
CO, CO2, THC, O2 and other unwanted components in the air are adsorbed, leaving Nitrogen Gas of required purity.
During the desorption cycle, the trapped substances adsorbed are released again at low pressure and the adsorber
is ready for next cycle.

Salient Features Applications


Generator with PSA Technologies with auto generation GC-FID, FPD, NPD, TCD, AED
Generator with all digital control for precise pressure control GC-MS, LC-MS-MS, ICP / NMR
Generator has in built pressure switch which shuts off the generator in FTIR / IR, ELSD detector, CAD detector
case of over pressure built up All Analytical Instruments
Generator with programming facility to save power consumption &
user friendly parameters
Flow rate from 200 ml/min 2000 ml/min.
CE certified

Technical Specification for Nitrogen Generator

PRINCIPLE SPECIFICATIONS N2 Specification: NG-02 (A) for 2 GC N2 Specification: NG-02 for 5 GC


Moisture < 5 ppm < 5 ppm
Oxygen < 5 ppm < 5 ppm
Total Hydrocarbon < 0.5 ppm < 0.5 ppm
Purity UHP (GC grade) UHP (GC grade)
Micron particulates 0.01 μ 0.01 μ
CO & CO2 < 2ppm < 2 ppm
Capacity 200 ml/min at 80 psi 500 ml/min at 80 psi
Method of purity Pressure Swing Adsorption (PSA) Pressure Swing Adsorption (PSA)
Room temperature 5 °C to 25°C 5 °C to 25°C
Startup time 2 hr / programmable by Timer 2 hr / programmable by Timer
Electrical requirement 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph
Dimenssion (in mm) 400 (W) x 700 (H) x 700 (D) mm 400 (W) x 700 (H) x 700 (D) mm
Weight 55 kg (approx) 55 kg (approx)
Gas Outlet Port 1/8" OD 1/8" OD

02
Nitrogen-Air Combination Generator for GC Model: NAG-01/NAG-01(A)/NAG-01(M)

Schematic Diagram of Nitrogen Generator & Zero Air Generator

Purge line
NRV

Solenoid
valve

Adsorbent tower Storage tank

Cooling coil
Pressure / flow
controller

Solenoid
inlet
Air valve
Inlet Solenoid
exhaust Dust filter
Compressed valves
air filter Vent Vent

Model : NAG-01 / NAG-01(A) / NAG-01(M)

Nitrogen & Air Generator produces a continuous flow of high purity Nitrogen & Zero Air at selected pressure.
The modular Pressure Swing Adsorption (PSA) unit operates with alternating pressure increase and decrease.
Air flows under pressure through the reaction towers containing molecular sieve adsorber.
Moisture, CO, CO₂, HC, Oxygen and other unwanted components in the air are adsorbed, leaving Nitrogen
Gas of required purity & in another set of towers Moisture, CO, CO₂ , HC and other unwanted components in the
air are adsorbed, leaving Zero Air Gas.
Nitrogen & Air combination generator is compact (2 in 1) & also cost effective and the compressor for generating both
the gases is common.

Nitrogen-Air Combination Generator for 2 GC & 5 GC Model


PRINCIPLE For 2 GC model NAG - 01(A) For 5 GC model NAG - 01
SPECIFICATION N2 Specification Zero Air Specification N2 Specification Zero Air Specification
Moisture < 5 ppm < 5 ppm < 5 ppm < 5 ppm
Oxygen < 5 ppm - < 5 ppm —
Total Hydrocarbon 0.5 ppm 0.3 ppm 0.5 ppm 0.3 ppm
Purity UHP (GC grade) UHP (GC grade) UHP (GC grade) UHP (GC grade)
CO & Co2 < 2 ppm < 2 ppm < 2 ppm < 2 ppm
Micron Particulates 0.01 μ 0.01 μ 0.01 μ 0.01 μ
Capacity 200 ml/min at 80 Psi 1500 ml/min at 80 psi 500 ml/min at 80 psi 4000 ml/min at 80 Psi
Method of purity Pressure Swing Adsorption (PSA) Pressure Swing Adsorption (PSA) Pressure Swing Adsorption (PSA) Pressure Swing Adsorption (PSA)
Air Compressor Inbuilt External
Start-up time 2 hr / programmable by Timer 10 min 2 hr / programmable by Timer 10 min
Electrical requirement 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph
Dimension (in mm) 400(W) x 700(H) x 700(D) mm 400(W) x 700(H) x 700(D) mm 400(W) x 700(H) x 700(D) mm 400(W) x 700(H) x 700(D) mm
Weight 60 kg (approx) 60 kg (approx)
Gas Outlet Port 1/8" OD 1/8" OD 1/8" OD 1/8" OD

Nitrogen-Air Combination Generator for 5 GC & TOC Model : NAG01+TOC


PRINCIPLE SPECIFICATION N2 Specification for GC Zero Air Specification for GC Zero Air Specification for TOC
Moisture < 5 ppm < 5 ppm < 0.3 ppm
Oxygen < 5 ppm - -
Total Hydrocarbon < 0.5 ppm 0.3 ppm < 0.1 ppm
Purity UHP (GC grade) UHP (GC grade) UHP (TOC grade)
CO & CO2 < 2 ppm < 2 ppm < 0.2 ppm
Micron particulates 0.01 μ 0.01 μ 0.01 μ
Capacity 500 ml/min a 5 kg/cm² 4000 ml/min a 5 kg/cm² 500 ml/min a 5 kg/cm²
Method of purity Pressure Swing Adsorption Pressure Swing Adsorption Pressure Swing Adsorpon
(PSA) & Depressurisation (PSA) (PSA) & HC Cracking Furnace
Room temperature 5 °C to 25°C 5 °C to 25°C 5 °C to 25°C
Start-up time 2 hr / programmable by Timer 10 min 30 min
Electrical requirement 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph 230 V AC, 50 Hz, 1 ph
Size of NAG 400(W) x 700(H) x 700(D) mm 400(W) x 700(H) x 700(D) mm 400(W) x 700(H) x 700(D) mm
Weight 55 kg (approx) 55 kg (approx) 55 kg (approx)
Gas Outlet Port 1/8" OD 1/8" OD 1/8" OD

03
Hydrogen Gas Generator
Technical Specification
PGH-300 PGH-500 PGH-1000
Max Hydrogen Flowrate 300 ml/min 500 ml/min 1000 ml/min
Delivery Pressure 0-60 psig (0-0.4 Mpa)
% purity 99.999%
Power 198-242V (AC); 50Hz,1 Phase
Min/max Temperature 5-40°C
Suitable Environment non-corrosive and dust-free
Dimensions 420 x 210 x 350mm (LxWxH)
Weight 20 kg (approx)
Fluid Tank Capacity 3 Ltr.
Gas Outlet Port 1/8" OD
* Higher capacity model also available like 2 LPM & 3 LPM

Salient Features
Low working pressure & continuous UHP grade flow (99.999%)
Generate hydrogen with PEM technology
Generator has in built pressure switch which shuts off the generator in case of Over pressure built up.
Sleep mode in case no use of H2 gas.
Hydrogen leak detection facility inside the generator. (Optional)
Any leak detected will shut the system and hyrogen production is halted. (Optional)
Low Water Level Alarm (Optional)

Applications
GC-FID

Hydrogen is produced in the PGH Series Hydrogen Generators by the most advanced electrolytic membrane technology.
The application of voltage across the electrolyte results in hydrolysis, breaking down the water molecule into hydrogen
and oxygen gas, which are separated by the gas permeable membrane.
Once separated, the hydrogen gas goes through a series of purification and moisture removal systems to achieve the
desired level of purity while the oxygen gas is being discharged into the atmosphere.
Electrolytic membrane technology has its advantages over alternative hydrogen generating techniques as it is clean,
requires less maintenance and there is no need to store chemicals to maintain operation.
Only pure double distilled water (initially some KOH), is required to provide trouble free long term operation.
Membrane separation is also less time consuming as only water is needed for routine maintenance.
Another model with no acid and alkaline solution (KOH & NaoH) is also available.

Flow Diagram of Hydrogen Generator

Fluid Input

Oxygen

Molecular
Electrolysis Sieve
Fluid Chamber
Tank Pressure
Monitoring
System

Hydrogen
Electrolysis Output
Control System Pressure
Gauge
Pressure
Control System

Flow Display

04
3 IN 1 Combination Gas Generator for N2, ZA & H2

Model : NHZA-03A (Modular & Stackable)


Combination Gas Generator for UHP Nitrogen, Zero Air & Hydrogen.
Nitrogen & Air Generator produces a continuous flow of high purity
Nitrogen at selected pressure.
The modular Pressure Swing Adsorption (PSA) unit operates with
alternating pressure increase and decrease.
Air flows under pressure through the reaction towers containing
molecular sieve adsorber.
Moisture, CO, CO₂, HC, Oxygen and other unwanted components in the
air are adsorbed, leaving Nitrogen Gas of required purity & in another
set of towers Moisture, CO, CO₂ , HC and other unwanted components
in the air are adsorbed, leaving Zero Air Gas.
High Purity Hydrogen Gas Generator.
Hydrogen is produced in the PGH Series Hydrogen Generators by the
most advanced electrolytic membrane technology.
The application of voltage across the electrolyte results in hydrolysis,
breaking down the water molecule into hydrogen and oxygen gas,
which are separated by the gas permeable membrane.
Modular & Stackable, Floor Space Saving design with small footprint.

Purge line
Flow Diagram of Hydrogen Generator NRV
Fluid Input
Solenoid
Oxygen valve

Adsorbent tower Storage tank


Molecular
Electrolysis Sieve
Fluid Chamber
Tank Pressure Cooling coil
Monitoring Pressure / flow
System
controller
Hydrogen
Electrolysis Output Solenoid
Control System Pressure
inlet
Air valve
Gauge
Pressure Inlet Solenoid
Control System exhaust Dust filter
Compressed valves
Flow Display air filter Vent Vent

Principle of 3 in1 Gas Generator Model-NHZA-03 for 2 to 3 GC / Model-NHZA-05 for 5 GC

Principle N2 Gas Zero Air H2 Gas


Moisture < 5 ppm <5ppm <5ppm
Oxygen < 5 ppm - <5ppm
Total Hydrocarbon 0.5ppm 0.3ppm 0.3ppm
CO & CO2 <2ppm <2ppm <2ppm
Purity UHP UHP UHP
Micron particles 0.01μ 0.01μ 0.01μ
Capacity of NHZA-03 / 200ml/min at 5kg/cm² / 1500ml/min at 5kg/cm² / 300ml/min at 4kg/cm² /
NHZA-05 500 ml/min at 5 kg/cm² 4000 ml/min at 5 kg/cm² 500 ml/min at 4 kg/cm²
Air Compressor Inbuilt Inbuilt NA
Method of Purification Pressure Swing Adsorption Catalytic conversion Filtration PEM Technology
and Depressurization
Room Temperature 10°C to 25°C
Start uptime 2hr/programmable by timer 10 min 30min
Electrical Supply 230 V AC, 50Hz, 1ph, 5 amp
Size of the 3 in1 Generator 1100H X 350W X 600D mm
Weight (approx.) 90 kg
Power Consumption 600W
Gas Outlet Port 1/8” OD 1/8” OD 1/8” OD
05
Nitrogen Gas Generator for ELSD and CAD
Nitrogen Generator produces a continuous flow of
high purity Nitrogen at selected pressure.
The modular pressure swing adsorption (PSA) unit
operates with alternating pressure increase and decrease.
Untreated air flows under pressure through the reaction
towers containing carbon molecular sieves adsorber.
Moisture, CO, CO2, THC, O2 and other unwanted
components in the air are adsorbed, leaving
Nitrogen Gas of required purity.
During the desorption cycle, the trapped substances
adsorbed are released again at low pressure and the
adsorber is ready for next cycle.
Salient Features
No external compressor required.
Inbuilt silent oil free air compressor.
Automatic heatless air dryer timer based operation.
Microcontroller based Nitrogen Generator with
2 Channel Analog Sensors for pressure and with four
relay output.
Model : NG-02 (M) for ELSD & CAD
Designed as plug & play system.

Principle Specification / Model Model for ELSD Model for CAD


Technology PSA PSA
Inbuilt Air Compressor Silent Oil Free Silent Oil Free
Air Compressor Air Compressor
Oxygen 0.1 % 0.1 %
Nitrogen/ Outlet Purity 99.9 % N2 and 99.9 % N2 and
other inert Gases other inert Gases
Max Flow 5 LPM 5 LPM
Max Pressure 5 kg/cm² 5 kg/cm²
Particles < 0.01μm < 0.01μm
Room Temperature 5 °C to 25 °C 5 °C to 25 °C
Gas Outlet Connection 1/8" OD Connection 1/8" OD Connection
Electrical Requirements 220 V AC 50 HZ, 4 A 220 V AC 50 HZ, 4 A
Dimensions (mm) WxDxH 200 x 700 x 700 200 x 700 x 700
Weight (kg) 70 (Approx) 70 (Approx)
Gas Outlet Port 1/4" OD 1/4" OD

06
Nitrogen Generator for Nitrogen Concentrator / Turbo Evaporator
Technical Specification
PRINCIPLE SPECIFICATIONS NG-02T
Moisture 50-200 ppm
Total Hydro Carbon < 10 ppm
CO & CO2 < 10 ppm
Purity 98%
Micro Particulates < 0.01μ
Capacity of N2 Generator 50 LPM to 200 LPM at 60 psig (as per selection of model)
Method of purification Pressure Swing Adsorption (PSA)
Room temperature 5 °C to 25 °C
Start up time 1 hrs
Electrical requirements 230 V AC, 50 Hz, 1 Phase & Air Compressor
440VAC, 50Hz
Dimension of N2 Generators in mm. 650W X 650D X 1200H (for 50 LPM)
650W X 650D X 1500H (for 100 LPM)
700W X 700D X 1500H (for 140 LPM)
700W X 700D X 1500H (for 200 LPM)

NG-02T Net Weight 100 kg - 300kg (as per selection of model)

High Capacity Nitrogen Generator

Schematic Diagram of Gas Generator


Nitrogen Generator High Capacity for Plant /
Production / Purging / Reactors etc. SV
CONTROL PANEL

Complete system Skid Mounting with Inter


PG
AIR FROM
COMPRESSOR
PRESSURE
TEMP SWITCH

Connection Piping.
SENSOR
OIL
REMOVAL
WET AIR REFRIGERATION PREFILTER FILTER
RECEIVER AIR
DRYER

Complete System with Compressor, Dryer, Receiver,


ADV

PG
DRY
AIR

Analyzer, Automatic Change Over System from


ADV ADV

TO D RAIN TO D RAIN PILOT AIR FOR HEADER


OPERATION OF DRY
ADV
VALVES AIR

Generator v/s Cylinder etc.


TO D RAIN ADV RECEIVER

TO D RAIN

PG PG

Flow Range from 10 Nm³ to 100 Nm³ as per


SV

PG P SA P SA
SILENCER

PURE

selection of model
ADSORBER ADSORBER
NITROGEN SV No. 1 No. 2
ROTAMETER

PG

Purity ranging from 95% to 99.99% as per selection


NITROGEN
N RV

VESSEL

BACK
PRESSURE NITROGEN
PRESSURE

of model.
CONTROLLER SURGE
SWITCH VESSEL
AFTER FILTER

Higher capacity other than mentioned are also


OXYGEN
ANALYZER

available.

07
Nitrogen Generator for LC-MS / LC-MS-MS (PSA Technology)

Nitrogen Generator produces a continuous flow of high purity


Nitrogen at selected pressure.
The modular pressure swing adsorption (PSA) unit operates
with alternating pressure increase and decrease.
Untreated air flows under pressure through the reaction
towers containing carbon molecular sieves adsorber.
Moisture, CO, CO₂, HC, Oxygen and other unwanted
components in the air are adsorbed, leaving Nitrogen Gas of
required purity.
During the desorption cycle, the trapped substances
adsorbed are released again at low pressure and the adsorber
is ready for next cycle.
Flow range available from 10 LPM to 100 LPM.
Microcontroller digital display.

NG02LS / Sciex Model

Principle Specification For LC-MS (NG-02L) For LC-MS-MS (NG-02LS (for Sciex model)
Moisture 5 ppm 5 ppm
Total Hydro Carbon < 0.5 ppm < 0.5 ppm
CO & CO2 < 2 ppm < 2 ppm
Purity 99.9% 99.9%
Micro Particulates < 0.01μ < 0.01μ
Capacity of N Generator 6 to 30 LPM at 100 psig 12 LPM at 60 psig (pure nitrogen)
(as per selection of model) 18 LPM at 100 psig ( filtered zero air)
18 LPM at 60 psig (purified dry air)
Method of purification Pressure Swing Adsorption (PSA) Pressure Swing Adsorption (PSA)
Room temperature 5 °C to 25 °C 5 °C to 25 °C
Start up time 1 hrs / programmable timer 1 hrs/ programmable timer
Electrical requirements without Compressor 230 V AC, 50 Hz, 1 Ph, 2 Amp 230 V AC, 50 Hz, 1 Ph, 2 Am p
Dimension of N2 Generators in mtr. 1.5H x 0.8W x 0.8D (approx) 2H x 1W x 1D (approx)
(without compressor) (approx.)
Net Weight (without compressor) (approx.) 100 kg - 200kg 100 kg - 200 kg
(as per selection of model) (as per selection of model)
Gas Outlet Port 6 mm PU 6 mm PU

Installation Diagram for Nitrogen Generator for LCMS / LCMSMS (PSA Technology)

Outlet

Prefilter Air Dryer er filter

N2 Generator
Receiver
Tank
Air Compressor

08
Gas Generator for LCMS / LC-MS-MS (Membrane Technology)

Model : NGLC - 32A Model : NAG - LCSPA Model : NAG - LCSA


( Nitrogen for LCMS) For Perkin Elmer For Sciex LCMS
Q- Sight / Shimadzu

Features & Benefits


Inbuilt Silent oil free air compressor. N2
Inbuilt Air Storage tank for inbuilt compressor.
Designed as plug & play system.
Cost effective & Economical compared to imported generators.
Gas on demand, no health hazards, no need to worry about running
out of gas.
Suitable for all Climatic conditions.
Exstock / Fast service / Spares readily available.
Customised gas generators also available on request.
Floor mounted model with caster wheel.

Technical Model : NGLC - 32A Model : NAG - LCSPA Model : NAG - LCSA
Specifications ( Nitrogen for LCMS) For Perkin Elmer Q- Sight & Shimadzu For Sciex LCMS
Maximum Flow Rate N2 32 LPM @100 psig 1) N2 32 LPM @100 psig for Perkin Q Sight
2) N2 32 LPM @100 psig for Shimadzu
1) N2 (Curtain Gas) 12 LPM @100 psig
2) Exhaust Gas 18 LPM @ 100 psig
3) Dry Air 70 LPM @60 psig for Perkin Q Sight 3) Source Gas (Dry Air) 18 LPM @ 60 psig
4) Dry Air 25 LPM @60 psig for Shimadzu

Inbuilt Air Compressor Yes Yes Yes


Nitrogen Outlet Purity 95% - 99.9% 95% - 99.9% 95% - 99.9%
(Depends on flow) (Depends on flow) (Depends on flow)
Particulates <0.01μm <0.01μm <0.01μm
Phthalates None None None
Suspended Liquids None None None
Gas Outlet Connection 1/4" OD 1/4" OD 1/4" OD
Electrical Requirements 230 V 50 Hz, 8.5 A 230 V 50 Hz, 12.5 A 230 V 50 Hz, 12.5 A
Power Consumption 2500 Watts 3400 Watts 3400 Watts
Suitable for Agilent, Waters, Thermofisher LCMS Perkin Elmer QSight, Shimadzu AB Sciex
Dimensions LxBxH 62x64x62 cm 62x64x62 cm 62x64x62 cm
Weight (Kg) 80 80 80
Gas Outlet Port 6 mm PU 6 mm PU 6 mm PU

09
Wall Mounting Generator for LCMS (Membrane Technology)

Model: NGLC 32 Model: NAGLCSP Model: NAGLCS


(Wall mounted Nitrogen (Wall mounted Generator (Wall mounted Generator
for LCMS) for Perkin Elmer QSight/Shimadzu) for Sciex LCMS)

Features & Benefits


Compact Design
Cost effective & Economical compared to imported generators. N2
External air dryer and Oil free Air compressor to be provided by
customer.
Gas on demand, no health hazards, no need to worry about running
out of gas.
Suitable for all Climatic conditions.
Fast service / Spares readily available.
Customised gas generators also available on request.

Technical Model : NGLC - 32 Model : NAG - LCSP Model : NAG - LCS


Specifications ( Nitrogen for LCMS) For Perkin Elmer Q- Sight & Shimadzu For Sciex LCMS
Maximum Flow Rate N2 32 LPM @100 psig 1) N2 32 LPM @100 psig for Perkin Q Sight
2) N2 32 LPM @100 psig for Shimadzu
1) N2 (Curtain Gas) 12 LPM @100 psig
2) Exhaust Gas 18 LPM @ 100 psig
3) Dry Air 70 LPM @60 psig for Perkin Q Sight 3) Source Gas (Dry Air) 18 LPM @ 60 psig
4) Dry Air 25 LPM @60 psig for Shimadzu

Oil free Air Compressor External External External


Nitrogen Outlet Purity 95% - 99.9% 95% - 99.9% 95% - 99.9%
Particulates (Depends on flow) (Depends on flow) (Depends on flow)
Phthalates <0.01μm <0.01μm <0.01μm
Suspended Liquids None None None
Power Consumption None None None
Gas Outlet Connection 1/4" OD 1/4" OD 1/4" OD
Electrical Requirements NA NA NA
Power Consumption NA NA NA
Suitable for Agilent, Waters, Thermofisher LCMS Perkin Elmer QSight, Shimadzu AB Sciex
Dimensions LxBxH cm 25 x 25 x 73 25 x 25 x 73 25 x 25 x 73
Weight (Kg) 15 15 15
Gas Outlet Port 6 mm PU 6 mm PU 6 mm PU

PCI Analytics Pvt. Ltd.


® A-71, Road No.22, Wagle Industrial Estate, Opp. Lodha Grandezza, Near Spraytech Circle,
(Tata Motors Bus Stop), Thane (W), Maharashtra, India. 400604.
Tel.: +91 22 6831 9393 | Mob.: +91 93237 00351 | Email : info@pcianalytics.in | Web : www.pcianalytics.in
Regd. Office : 3/14, Bhandup Industrial Estate, Pannalal Compound, L.B.S Marg, Bhandup (W), Mumbai - 400078.
Ahmedabad Chandigarh Chennai Delhi Hyderabad Kolkata Pune Vadodara Bangladesh UAE

You might also like