This document provides specifications for four high static ducted air conditioning units with cooling capacities ranging from 66,000 BTU to 204,000 BTU. It lists key details such as model numbers, dimensions, cooling and power specifications, component details, and installation requirements for each unit size. Piping sizes, insulation thickness, pre-charge refrigerant quantities, and electrical specifications vary depending on the unit capacity.
This document provides specifications for four high static ducted air conditioning units with cooling capacities ranging from 66,000 BTU to 204,000 BTU. It lists key details such as model numbers, dimensions, cooling and power specifications, component details, and installation requirements for each unit size. Piping sizes, insulation thickness, pre-charge refrigerant quantities, and electrical specifications vary depending on the unit capacity.
This document provides specifications for four high static ducted air conditioning units with cooling capacities ranging from 66,000 BTU to 204,000 BTU. It lists key details such as model numbers, dimensions, cooling and power specifications, component details, and installation requirements for each unit size. Piping sizes, insulation thickness, pre-charge refrigerant quantities, and electrical specifications vary depending on the unit capacity.
This document provides specifications for four high static ducted air conditioning units with cooling capacities ranging from 66,000 BTU to 204,000 BTU. It lists key details such as model numbers, dimensions, cooling and power specifications, component details, and installation requirements for each unit size. Piping sizes, insulation thickness, pre-charge refrigerant quantities, and electrical specifications vary depending on the unit capacity.
Description Unit 66K HSD 102K HSD 132K HSD 204K HSD Model No/ Qty MCAD66WSC2 MCAD102WSC2 MCAD132WSC2 MCAD204WSC2 FG Code 224050061210 224050038300 224050061220 224050041860 IDU Code 224050038250 224050038280 224050041810 224050041840 ODU Code 224050038260 224050038290 224050041820 224050041850 Qty of unit (IDU/ODU) Nos 1/1 1/1 1/2 1/2 Cooling Capacity TR / Kw / BTU 5.5 / 19.3 / 66000 8.5 / 29.9 / 102000 11 / 19.3 / 132000 17 / 29.9 / 204000 Operating Power (IDU/ ODU) V-ph-Hz 220~200-1-50 / 380~415-3-50 Total Input Power/ Current Watts / A 6500 / 11.5 9200 / 16.2 13500 / 24 20200 / 34 Air Flow Volume (Max) CMH / cfm 3740 / 2200 5780 / 3400 7476 / 4400 11560 / 6800 Static Pressure Pa/ mm of WG 200 / 20 280 / 28 350 / 35 Noise Level (Max-Min) dB 65 72 75 77 Compressor Make / Type/ Qty Danfoss / Emerson/ Scroll/ 1 Danfoss / Emerson/ Scroll/ 2 Pipe Size (Liquid / Gas) Inch / Qty 1/2" / 7/8" x 1 Set 5/8" / 1-1/8" x 1 Set 1/2" / 7/8" x 2 Set 5/8" / 1-1/8" x 2 Set Metering Device TXV Thermostatic Expansion Valve with pressure equalizer located at IDU Insulation Thickness (Liquid/ Gas) mm Nitrile Rubber tube of 19mm thick for 7/8" & 1-1/8" Gas pipe, not mandatory for Gas pipe Max. Pipe length Meters 35 Max. Height Difference Meters 20 U Trap (ODU above) Nos / meters 1 No at every 4 meter vertical length in Gas pipe Main input Power Location IDU/ ODU at ODU Main Power wire Spec./ODU Type/ Sqmm/ Core (Cu / 4 / 4 + E) 1 set (Cu / 6 / 4 + E) 1 set (Cu / 4 / 4 + E) 2 set (Cu / 6 / 4 + E) 2 set Inter Connecting wire Spec./ODU Type/ Sqmm/ Core Cu / 1.5 / 3 + E Cu / 1.5 / 5 + E Pre gas charge qty for 7.5 M length Kg/ODU R 410a - 2.3 R 410a - 3.25 R 410a - 2.3 R 410a - 3.35 Additional Gas qty/ Mtrs/ Circuit gm 100 150 100 150 Net dimension IDU (W x D x H) mm 1200 x 725 x 345 1619 x 675 x 460 1875 X 700 X 460 2150 X 850 X 560 Net dim. ODU (W x D x H) mm 900 x 320 x 800 900 x 580 x 960 900 x 320 x 800 900 x 580 x 960 Net weight (IDU/ ODU) Kg 50 / 80 77 / 135 130 175 Air outlet mouth size (W x H) mm 876 x 143 968 x 273 1083 x 270 1600 x 270 Trap Door dimension (W x D) mm 1600 x 1025 2020 x 975 2275 x 1000 2550 x 1150 Air Filter built-in Yes / No Yes Drain Pump/ Head mm Optional / 750 Drain Pipe Dia mm ODΦ32 ODΦ32 ODΦ32 ODΦ32 Ambient operating Range ᵒC 18 ~ 50 Remote (Coded / Cordless) Inbuilt / Optional MCB Rating Pole / Class- Amp/ Qty TPN / C- 20 / 1 TPN / C- 32 / 1 TPN / C- 20 / 2 TPN / C- 32 / 2 1- All dimensions are in mm ODU Châssis Dimension & Foot-print in mm 2- Mouth size- 874 x 140 Chassis Wedth Depth Height Mounting Mounting 3- Refrigerant Filter Drier fitted in right side where control panel fitted in left side of unis Types (W) (D) (H) Hole (A) Hole (B) NXG- B 900 320 820 600 360 1- All dimensions are in mm 2- Mouth size- 968 x 269 3- Refrigerant Filter Drier fitted in right side where control panel fitted in left side of unis ODU Châssis Dimension & Foot-print in mm 1- All dimensions are in mm Chassis Wedth Depth Height Mounting Mounting 2- Mouth size- 1019 x 270 Types (W) (D) (H) Hole (A) Hole (B) 3- Refrigerant Filter Drier fitted in right side where control panel fitted in left side of unis NXG- B 900 320 820 600 360 1- All dimensions are in mm 2- Mouth size- 1599 x 270 3- Refrigerant Filter Drier fitted in right side where control panel fitted in left side of unis