Best Practices For Using Multiple Network Interfaces

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 26

Best Practices for Using

Multiple Network Interfaces


(NICs) with NI Products
Updated Mar 2, 2022


Overview
It is becoming commonplace to have more than one Ethernet adapter in a PC or embedded
controller, especially in systems where wired and wireless adapters are both present.
However, the presence of more than one Network Interface Card (NIC) can cause
connectivity problems if each network interface is not carefully configured to account for
the overall network layout. This tutorial outlines basic Ethernet networking concepts,
explains why incorporating multiple NICs can cause problems, and provides best practices
to follow when working with a multi-NIC system. In addition, several common scenarios are
explored, including an NI Real-Time Hypervisor system that features a complex network
configuration.

Contents
 Background: Ethernet Networking Concepts
 Guidelines for Configuring Multi-NIC Systems
 Example Scenarios
 Additional Resources

Background: Ethernet Networking Concepts


Before explaining best practices for configuring controllers with multiple NICs, it is necessary
to understand some basic concepts related to Ethernet networking. This section explains
how individual NICs are addressed, how packets are routed on Ethernet networks, and what
a typical Ethernet packet transfer looks like. 
If you are already familiar with these concepts or are not concerned about the "why" behind
the recommendations in this paper, then you can skip to the Guidelines for Configuring
Multi-NIC Systems section.

Data Link Layer: MAC Addressing


Just like a home or business address must be specified in order to send a piece of postal
mail, every port on every Ethernet adapter is assigned a unique address called a Medium
Access Control (MAC) address by the manufacturer. MAC addresses consist of 48 bits, and
are commonly expressed in groups of 2 hexadecimal digits (e.g. 01:23:45:67:89:ab). The MAC
address or addresses for a specific Ethernet adapter are commonly printed on a label on the
device itself, and are also accessible via operating system networking settings. 

When Ethernet data is sent between two computers, it is sent in small pieces called
"packets", and those packets contain the MAC address of the receiving interface. Each
interface is continually listening for packets sent to its unique address.

Figure 1. Each network interface controller (NIC) in a computer has a unique medium access
control (MAC) address. If multiple NICs are installed in one computer, they each have their
own MAC addresses.

Internet Layer Addressing


If every computer in the world were connected to one large wire and knew every other
computer's MAC address, then no further addressing schemes would be required. However,
this is impractical for several reasons. First, with such a large shared connection packet
collisions would occur frequently, causing communication to be unreliable. Second, storing
the address of every other computer on the planet on each machine would require a large
amount of memory, and is not a good strategy due to the constant addition of new devices.

IP Addresses (IPv4)

Clearly, a different scheme of addressing is needed to enable computers to communicate


with each other via Ethernet. In practice, users can assign one or more Internet Protocol (IP)
addresses to each MAC address, and set these IP addresses up in such a way that most
network traffic occurs in small "pools" rather than across a wider group of machines. In
practice, IP addresses are typically specified by a 32-bit value, and are commonly written as
four groups of 3-digit decimal values (e.g. 192.168.100.100). Consider a network with 10
computers configured such that the computers have IP addresses ranging from
192.168.100.0 to 192.168.100.9. If all machines follow a rule where all addresses with format
192.168.100.xxx are assumed to be inside the internal network, then it is easy to tell whether
communicating with a given IP address requires accessing some other network or not.

Sample rule: all interfaces with IP addresses in the range 192.168.100.0 to 192.168.100.255


are inside of the local network, and interfaces with other addresses are outside.

Inside or Outside Local Network?


(following the sample rule)

Inside

Inside

Outside

Outside

Table 1. Since IP addresses can be assigned to individual NICs by the user, it is possible to
assign similar IP addresses to a group of interfaces and then easily determine whether a
given IP address is inside or outside of the local network.

This simple idea has significant benefits. Whereas MAC addresses do not typically follow a
pattern in a given set of machines (they are randomly distributed by vendor), since IP
addresses are user-configurable they can be set up to follow a logical, hierarchical pattern.
Using this pattern, small groups of computers can communicate with each other with only
local traffic, therefore reducing data collisions in the larger network. In addition, since there
are more than 2^32 connected Ethernet devices on the planet, IP addresses can be reused
across multiple smaller networks while those machines are still accessible via a process
called Network Address Translation (NAT). A detailed discussion of NAT is beyond the scope
of this tutorial.

When configuring IP addresses, you are likely to run across addresses of the form 10.x.x.x,
192.168.x.x, or 172.x.x.x. Each of these ranges have been specially designated for private
network use, so you can be sure that no other public server (e.g. google.com) will use the
same IP address if you use one of these.

It should be noted that the information in this section pertains to the most commonly used
version of the Internet Protocol called IPv4. The next version of the Internet Protocol, IPv6,
uses 128-bit addresses but is not widely used today (although adoption is expected to grow
in the next several years).

Subnet Masks

So, when looking at an IP address to send data to, how does a given computer decide if it is
inside of the local network, or whether it will rely accessing an outside network? In other
words, if we want computers to follow a rule as was the case with the example in the
previous section, how is that rule specified?

The key component here is the subnet mask, a group of 32 bits expressed in 4 groups of
numbers just like the IP address (e.g. 255.255.255.192). A binary 1 value in one of the 32 bit
positions means that if the IP address bit is different in this position between the sender and
receiver, then Ethernet packets must be routed to an outside network. On the contrary, a
binary zero in a given position means that if the IP address bit is different then it does not
matter; if all other bits are the same between the sender and receiver's IP address then the
receiver is assumed to be on the same local network.
Figure 2. Subnet masks provide a way to specify the "rule" for which IP addresses are
included in a local network and which fall outside of the local network.

Gateways and Default Gateways

How are Ethernet packets passed between local and outside networks? This task is typically
performed by a device called a router, that is also often referred to as a network gateway (in
this tutorial the two terms will be used interchangeably). For each Ethernet adapter
connected to a computer, the user often specifies an IP address, subnet mask, and default
gateway. The default gateway is the address of the router that should be used when packets
must be sent outside of the local network.

ARP Requests
At this point, note that at the lowest level, every single Ethernet packet that is sent must be
sent to a MAC address. IP addresses provide some advantages including the use of subnets,
but keep in mind that simply knowing the IP address of a remote computer's interface is not
enough information to ensure that a packet reaches that computer. For example, to
communicate between two computers on remote networks it may be necessary to pass
through several routers. At a low-level, one packet must be sent between the sending
computer and the first router, then another packet from the first router to the next, and so
forth until the final packet finally reaches the destination computer. For the packet to be
sent between each link, knowing the MAC address of the receiving router or computer's
interface is critical.

Imagine starting with an IP address of a destination computer on the local network: how
does the originating computer obtain the correct MAC address to send packets to? The
Address Resolution Protocol (ARP) is used for this. Continuing with the example, the
sending computer will send a special type of broadcast message called an ARP request on
the local network (requesting the MAC address for a certain IP address). All Ethernet devices
on the network are continually listening for these special requests, and will respond back to
the sender with their MAC address if they match the IP address specified. Once the MAC
address is received by the sending computer, that computer will usually store the MAC
address / IP address pair in a cache table for later usage. This prevents the continual need to
send ARP requests for the same destination interface.

Figure 3. For a computer to send data to a remote Ethernet interface, it must know the
MAC address of that interface. In the case that the MAC address is not known, a computer
can send an Address Resolution Protocol (ARP) request to a specified IP address, and the
destination machine will reply back with its MAC address.
If a router on the network knows that the IP requested is external to the local network, then
it can also respond to the ARP request with its own MAC address. This is called "proxy ARP".

Summary: Anatomy of an Ethernet Packet Transfer


Let us walk through the (simplified) process of sending a single Ethernet packet from a
source PC to a destination PC. We will assume that the Source PC contains multiple Ethernet
interfaces.

1. An Ethernet packet is ready to be sent by the source machine (this could be associated with a
specific application or OS process). The packet contains information about the IP address of
the receiver (this may have been obtained from a Domain Name Service (DNS) server).
2. If there is already a cached ARP entry containing the MAC address corresponding to the
receiver's IP address, then proceed to step 4.
3. The Sender looks at the IP address of the packet, and the subnet mask of its Ethernet
interfaces.
A. If the IP address falls within the subnet of a specific interface, then an ARP request is sent
from that interface.
B. If the IP address falls outside of the subnet of any interfaces, then the sender looks at the
default gateway entry for each interface.
i. If there is only one default gateway entry for all interfaces, then use its MAC address as
contained in the ARP table or send a new ARP request to find the MAC address of the
gateway.
ii. If there are multiple default gateway entries, then use the one with the lowest metric
(determined by several factors depending on the OS used). Find its MAC address in the
ARP table, or send a new ARP request to find the MAC address of the gateway.
iii. If there are no default gateway entries, send an ARP request on one or more interfaces to
see if a gateway responds with its own MAC (proxy ARP).
4. Send the Ethernet packet using the MAC address from the ARP cache or ARP request. If the
ARP request does not produce a result, then the packet is not deliverable. If the receiver is on
a remote subnet, then the packet is sent to a router and it is the router's job to send the
packet over the next link so that it ultimately reaches the receiver.

Back to top

Guidelines for Configuring Multi-NIC


Systems
When working with a computer that features multiple network interfaces, you must pay
closer attention to networking settings to avoid difficult-to-debug connectivity problems.
Follow these guidelines to ensure the best operation of your multi-NIC system. This includes
any PC or embedded controller running a desktop OS and LabVIEW, as well as any LabVIEW
Real-Time target with multiple Ethernet interfaces.

Rule 1: Be Careful About Automatic IP Assignment (via DHCP or


link-local addressing)
Most OSs are configured by default to obtain TCP/IP settings (IP address, subnet mask, and
default gateway) automatically using a Dynamic Host Configuration Protocol (DHCP) server.
If no DHCP server is found, then it is common practice for OSs to assign an IP address in the
169.254.x.x range,  which is referred to as a link-local IP address.

Make sure that you are familiar with the DHCP server(s) on your network, and what IP
address ranges and subnets they make use of. Likewise, make sure that you know if any
adapters in your computer use DHCP and no DHCP server is on the network, resulting in the
use of a 169.254.x.x address. If you are not familiar with the automatic IP assignment details
for your network, then there is a much higher chance that you will break Rule 2 or Rule 3
below.

If possible given your network configuration, it is best to manually specify IP settings for
each NIC in your multi-NIC PC. However, if you are on a network with other DHCP clients,
using DHCP may be unavoidable.

Rule 2: Avoid Assigning Multiple NICs in the Same Computer to


the Same Subnet
Using multiple NICs on the same subnet is the #1 cause of connectivity issues on
multi-NIC systems. While some OSs may be able to gracefully handle the presence of
multiple NICs on one subnet, others may mistakenly attempt to send packets out of the
wrong interface. You can remedy this issue by statically assigning one NIC (and the other
networked computers attached to that NIC) to the 192.168.x.x range with subnet mask
255.255.0.0, and another NIC on the 10.0.x.x range with subnet mask 255.255.0.0. Note that
this is just one possible configuration, any combination of two or more different subnets will
work. It is recommended that you use one of the designated private IP address ranges to
avoid conflicts with public servers on the internet.

In practice, there is rarely a good reason to use multiple NICs on the same subnet. One
advanced configuration that warrants this setup is using multiple adapters to increase
bandwidth is called adapter teaming, however this configuration is beyond the scope of this
paper.
Figure 4. When configuring a controller with multiple NICs, each NIC should communicate
with a different subnet. Configuring two or more NICs on the same subnet may cause
communication problems.

One of the most common scenarios resulting in multiple NICs being assigned to the same
subnet is when both a wired and wireless interface are used to connect to the same
network. Once again, while some OSs may handle this case gracefully, it is a best practice to
either configure the wired and wireless networks to exist on different subnets or to disable
one network interface when using the other.

Rule 3: Avoid Specifying a Default Gateway for More Than One


NIC
When a destination IP address does not fall within the subnet of any NIC, then a default
gateway is used to relay packets to the outside network. If multiple default gateways exist,
then packets may be routed to the wrong outside network, causing them to be
undeliverable. 

In most cases, you should be able to address all computers attached to a network interface
on the same private subnet, and leave the default gateway blank for that
interface. Typically only one NIC with a gateway to the internet or corporate network
should have a default gateway address specified. 

NIC 2
e Network and Internet Connected to Local Network

0.8 IP Address: 10.0.3.7

.0.0 Subnet Mask:255.255.255.0


168.1.1 Default Gateway: 0.0.0.0 (or blank)

Table 2. When choosing TCP/IP settings for a multi-NIC system, it is a best practice to
specify a default gateway for only one adapter. This is also true when one of the default
gateway addresses is obtained via DHCP.

In other cases where gateways are attached to subnets that connect with different network
interfaces, you can either manually specify network routes (this is an advanced practice) or
leave the default gateway blank for all interfaces.

While it is more efficient to specify a default gateway on one interface (this avoids the need
for an ARP on many packets transmitted to outside networks), leaving all default gateway
entries blank can help avoid problems in networks with multiple gateways. However, this
strategy will only work if network gateways support proxy ARP.

Back to top

Example Scenarios
Case 1: Connecting to One Public and One Private Network
In this scenario, a host PC is connected to both a corporate network (via NIC #1) which
allows internet access as well as a private network (via NIC #2) with several LabVIEW Real-
Time targets. The corporate network is setup to assign a DHCP address in the range of
10.0.x.x with subnet mask 255.255.0.0 to NIC #1. The default gateway (router) address is
10.0.0.1.
Figure 5. In this scenario, a multi-NIC controller is connected to both a corporate network
(with internet access) and a local private network.

Following the guidelines above, we can configure NIC #2, attached to the private network,
with a static IP outside of the 10.0.x.x subnet range. While it might be acceptable to use an
address in the 10.1.x.x range, as it is in a different subnet, it is possible that other 10.x.x.x IP
addresses are used for additional corporate servers, etc. Therefore, it is safer to use the
192.168.x.x range for the private network.

Since we are working with a small number of LabVIEW Real-Time targets in the private
network, we can use a subnet mask of 255.255.255.0 and assign each a static IP address in
the range 192.168.0.x; this will allow for up to 255 connected interfaces in the subnet. For
simplicity, the IP address of the host computer (NIC #2) will be set to 192.168.0.1.

It is important to leave the default gateway blank on the NIC #2 settings for the host
machine. In this way, only the NIC #1 default gateway will be used, which is what we want in
order to access the internet from the host. In addition, the default gateway can be left blank
on the LabVIEW Real-Time devices, as they should only be communicating within the local
subnet (there are no gateways connected).

NIC 2
e Network and Internet Connected to Local Private Network

0.0.x.x IP Address: 192.168.0.1

255.255.0.0 Subnet Mask: 255.255.255.0

HCP) 10.0.0.1 Default Gateway: 0.0.0.0 (unspecified)

Table 3. This table shows one possible IP address configuration for the system shown in
Figure 5 above. Notice that the two NICs connect to different subnets, and that only one
Default Gateway address is specified.

Case 2: Configuring an NI Real-Time Hypervisor System with


Virtual Ethernet Connection (local development)
NI Real-Time Hypervisor systems run a host OS (Windows or Linux) alongside LabVIEW
Real-Time simultaneously. Each physical NIC in these systems can be assigned to either the
host OS or LabVIEW Real-Time, and a virtual NIC (emulated in software) is also presented to
each OS to simplify inter-OS communication.

Figure 6. In this scenario, a Real-Time Hypervisor controller is running both Windows XP
and LabVIEW Real-Time in parallel. Both OSs are connected to each other through a set of
virtual NICs, and each OS has a physical NIC to connect to the corporate network & internet
as well.

In this scenario we will work with a Real-Time Hypervisor system that has two physical NICs,
and has the internal Virtual Ethernet connection enabled. One physical interface will be
assigned to Windows XP, and the other to LabVIEW Real-Time. Therefore, each OS will have
access to two NICs (the Virtual Ethernet connection and one physical connection). The
Windows XP side of the hypervisor system will be used for LabVIEW Real-Time application
development and deployment.

Assume that the physical connections are used to enable communication to the internet
from either OS via a corporate network. The virtual interface will be used only for
communication between LabVIEW Real-Time and Windows XP. The IP address of both
physical adapters connected to the corporate network will be dictated via DHCP, and will be
in the range 10.0.0.x with subnet mask 255.255.255.0. The gateway address is set to 10.0.0.1.

Following the guidelines above, we should set a static IP for each of the Virtual Ethernet
adapters using a different subnet than is used with the physical adapter on each OS.
Although other addresses in the 10.x.x.x range could be used, to be conservative we will set
the IP addresses of the Windows XP and LabVIEW Real-Time adapters to 192.168.0.1 and
192.168.0.2 respectively. The subnet mask of each is set to 255.255.255.0.
Because we want both Windows XP and LabVIEW Real-Time to access the internet via the
physical NICs, they should be the only adapters that have a default gateway set. Therefore,
we will leave the default gateway entry for both Virtual Ethernet NICs empty. Note that each
OS ultimately has only one default gateway specified.

LV RT Win XP Win XP
Virtual NIC Virtual NIC Physical NIC

IP Address:   IP Address:
0.0.0.x IP Address: (DH
192.168.0.2 192.168.0.1

Subnet Mask:
255.255.255.0 Subnet Mask: 255.255.255.0 Subnet Mask: (D
255.255.255.0

HCP) 10.0.0.1 Default Gateway: 0.0.0.0 (unspecified) Default Gateway: 0.0.0.0 (unspecified) Default Gateway

Table 4. This table shows one possible IP address configuration for the system shown in
Figure 6 above. Since there are two OSs running on a single hypervisor controller in this
case, the important thing to note is that each OS connects to separate subnets with each
NIC, and a maximum of one default gateway.

Case 3: Configuring an NI Real-Time Hypervisor System with


Virtual Ethernet (remote development)
In this scenario, two physical NICs are also used in a Real-Time Hypervisor system with the
Virtual Ethernet connection enabled as in Case 2 above. However, the physical NIC assigned
to LabVIEW Real-Time will be used for deployment from a networked host PC rather than
for internet access.

Figure 7. In this scenario, the LabVIEW Real-Time side of an NI Real-Time Hypervisor system
is connected to a remote Windows PC for LabVIEW Real-Time application development.
The Windows physical adapter will still be assigned a DHCP address in the range 10.0.0.x
with subnet mask 255.255.255.0. The Virtual Ethernet adapters on Windows XP and LabVIEW
Real-Time will once again use static IP addresses of 192.168.0.1 and 192.168.0.2 respectively,
with subnet masks of 255.255.255.0 and no default gateway.

To ensure that the physical NIC used with LabVIEW Real-Time is on a different subnet than
the Virtual Ethernet NIC, we can use an IP address of the form 192.168.1.x with subnet mask
255.255.255.0. Therefore, the remote PC adapter and LabVIEW Real-Time adapter connected
together can use static IP addresses of 192.168.1.1 and 192.168.1.2 respectively with subnet
masks of 255.255.255.0. Once again, no default gateway is needed since neither adapter
needs to access an outside network (no gateways are present on this subnet).

LV RT LV RT Win XP Win XP
Physical NIC Virtual NIC Virtual NIC Physica

IP Address: IP Address:   IP Address:


IP Add
192.168.1.2 192.168.0.2 192.168.0.1

Subnet Mask: Subnet


.255.0 Subnet Mask: 255.255.255.0 Subnet Mask: 255.255.255.0
255.255.255.0 255.25

0.0 Default Gateway: 0.0.0.0 Default Gateway: 0.0.0.0 Default Gateway: 0.0.0.0 Default
(unspecified) (unspecified) (unspecified) 10.0.0.

Table 5. With a remote LabVIEW Real-Time development machine added to this scenario, IP
address settings must be chosen such that the remote PC can connect with the LabVIEW
Real-Time side of the hypervisor system. 

Many other configurations are also possible, including using DHCP with the remote
development PC and LabVIEW Real-Time target (to allow connection with the internet), or
using additional NICs in the LabVIEW Real-Time target or remote host computer to connect
to the internet.

Case 4: Connecting to Two Routed Networks (advanced)


One more advanced scenario involves configuring a computer (running only one OS this
time) with two NICs that communicate with two local networks. Each network features a
gateway that can be used to relay packets to additional outside networks.
Figure 8. In this advanced scenario, a multi-NIC computer connects to two routed networks.
This TCP/IP configuration is more difficult to set up, especially if the outside networks are
not supersets of the local network subnets.

Imagine that local network A uses IP addresses of the form 10.0.0.x with subnet mask
255.255.255.0, and local network B uses IP addresses of the form 10.0.1.x with subnet mask
255.255.255.0. Local network A is connected via a gateway to outside network C, which uses
IP addresses of the form 192.168.0.x with subnet mask 255.255.255.0. Likewise, local
network B is connected to outside network D via a gateway, which uses IP addresses of the
form 192.168.1.x with subnet mask 255.255.255.0.

The goal is for our multi-NIC PC to be able to access any of the networks. We can connect
one NIC to local network A and assign the IP address 10.0.0.5 with subnet mask
255.255.255.0, and we can connect the second NIC to local network B and assign the IP
address 10.0.1.5 with subnet mask 255.255.255.0. If any default gateway were assigned, then
packets destined for the outside networks may be sent through the wrong gateway, and so
this is undesirable.

To solve this problem, we can leave the default gateway entries blank for the two NICs and
configure packet routing more manually in the OS. While all OSs are configured differently,
most enable the manual addition of routes by the user, and these routes can be configured
to persist across reboots of the system. Specifically, we need to add a route with IP address
192.168.0.x and subnet mask 255.255.255.0 to use the IP address of the gateway between
networks A and C (e.g. 10.0.0.1). The same needs to be done with IP address 192.168.1.x and
subnet mask 255.255.255.0 for the gateway between networks B and D (e.g. address
10.0.1.1).
NIC 2

IP Address: 10.0.1.5

.255.0 Subnet Mask:255.255.255.0

0.0 (unspecified) Default Gateway: 0.0.0.0 (unspecified)

C 1 and gateway 10.0.0.1 to route to 192.168.0.x Special Route: Use NIC 2 and gateway 10.0.1.1 to route to 19

Table 6. While typically only one NIC in a controller will connect with a gateway (to a
corporate network or the internet), more advanced configurations such as the one pictured
in Figure 8 above may require special OS routing entries to function properly. 

Additional routes may need to be added as the number of distinct subnets increases. In
practice, most networks are set up to avoid the need for this complex configuration by
ensuring that each computer is connected to only one gateway. 

Setting Up Dual Ethernet Port


Real-Time Controllers
Updated Aug 20, 2021


Environment
 

Hardware
 PXI Controller
 CompactRIO Controller
Software
 LabVIEW Real-Time Module
 Measurement & Automation Explorer (MAX)

This tutorial discusses communication between a host PC, or HMI, and a private
network target, which is connected to the secondary port of a dual Ethernet port
LabVIEW Real-Time controller.

Ethernet port 1 is used for communication between the dual port controller and the host
PC. This includes communicating with the controller via LabVIEW and Measurement &
Automation Explorer (MAX). Ethernet port 2 is used to communicate with a private
network, which is not visible to the host PC.

The LabVIEW project Dual Ethernet Ports on RT.lvproj provides a method for
communicating between the host PC and the private network.

In this example a cRIO 9074 is used for the dual port LabVIEW Real-Time controller;
however, this process can be used for any dual port LabVIEW Real-Time controller. A
cRIO 9012 is used as the private network target in this example.
 
Requirements
 Any dual Ethernet port LabVIEW Real-Time controller
 LabVIEW 8.5 or later
 LabVIEW Real-Time 8.5 or later
 NI-RIO 2.3.1 or later
 Ethernet crossover cable

Configure the targets


Initially, we will configure both targets to use DHCP and communicate with the host PC.
Once communication is established, we will deploy a startup application and Shared
Variable library to the private network target.

1. Configure the host PC, dual port controller, and private network target as shown
in Figure 1 below
Figure 1. Set-up configuration
 

2. Open Measurement & Automation Explorer (MAX) on the host PC. Both


LabVIEW Real-Time targets should be visible in MAX under Remote
Systems (see below). If a LabVIEW Real-Time target does not appear in MAX,
enable the IP RESET DIP switch on the controller, reboot the controller, and then
disable the IP RESET DIP switch. This will reset the IP address to 0.0.0.0.

3. Select the dual port controller under Remote Systems. Ensure that Obtain IP
address from DHCP server is selected in the IP Settings field. If Obtain IP
address from DHCP server is not selected, select it and click Apply.
Click Yes to reboot the controller. Wait for the controller to reboot.
 

4. Repeat step 3 for the private network target.


5. Select the dual port controller and click on Advanced Ethernet Settings to
launch the configuration window.
6. Select the MAC address of the secondary port. The IP Address field is the IP
address of the secondary port on the dual port controller. This IP address is static
and must not reside in the subnet of the primary port.
 

7. Set the IP Address and click OK.

 
Deploy the application
1. Open Dual Ethernet Ports on RT.lvproj  in LabVIEW 8.5 or later, on the host
PC.
2. In the project, right-click on Dual Port Controller and select Properties.
Select General from the left menu, enter the IP address of the dual port
LabVIEW Real-Time controller. Click OK.
 

3. Repeat step 2 for Private Network Target.


4. Expand Private Network Target in the project and open Private Network
Target VI.vi
5. Select Window»Show Block Diagram. This VI reads the USER 1 DIP switch on
the controller and writes the value to a locally hosted Shared Variable
named Private Network Target USER1 Switch.
6. In the project, right-click on Private Network Target SVs and ensure
that Autodeply Variables is not checked as seen below.  
 

7. In the project, right-click on Private Network Target SVs and


select Deploy. This will deploy the library of Shared Variable to the controller.
8. Expand Build Specifications under the Private Network Target.
9. Right-click on My Real-Time Application and ensure that the application is set
as startup (Unset as startup will be present as shown below).
 

10. Right-click on My Real-Time Application and select Deploy. This will deploy the


startup application to the controller.
11. Reboot the controller by pressing the RESET button, and wait for it to reboot.
12. Ensure that the USER1 LED toggles when the USER1 DIP switch is toggled.

Configure the target for a private network


The private network target is now ready for use, after deploying the Shared Variable
library, and LabVIEW application as a startup executable. We will now configure this
controller for use on a private network, allowing communication with Ethernet port 2 of
the dual port controller.
The following steps will configure the private network target with a static IP address,
which resides in the same subnet as the secondary port of the dual port controller. (i.e.
192.168.1.4 for the secondary port and 192.168.1.5 for the private network target, with a
subnet mask of 255.255.255.128).
1. Open MAX and select the private network target under Remote Systems.
2. Select Edit the IP settings in the IP Settings field. Enter an IP address that
resides in the same subnet as the secondary port of the dual Ethernet port
controller (i.e. 192.168.1.5).

3. Click Apply. Click OK on all dialog boxes and Yes to reboot.  You have now
configured the system as shown below. (Note: The host PC will most likely lose
all ability to communicate with the private network target. This behavior is
expected, since the private network target is on a different subnet. Useful Tip: To
maintain communication with both targets, use a second NIC in your
development machine, configured with a static IP that resides in the same subnet
as the private network target.)   

 
4. Disconnect the private network target from the switch or hub.
5. Now connect the private network target directly to Ethernet port 2 of the dual
port controller, using a crossover cable as seen below in Figure 2.

Figure 2. Deployment Configuration


 

6. Reboot the private network target to run the startup application.

 
Establishing communication between the host PC and private
network target
The private network target is now running a LabVIEW startup application and publishing
data via Shared Variables to its Ethernet port. Lastly, we will configure the Shared
Variable nodes on the dual port controller to communicate with the private network
controller.

1. In the project, right-click on Private Network Target and select Properties.


Select General from the left menu, enter the static IP address of the private
network target from step 2 in the previous section. Click OK. This will cause the
Shared Variable nodes to look at the correct IP address.
2. In the project expand Dual Port Controller.
3. Open Dual Port Controller RT VI.vi and open the Block Diagram. This VI reads
the value of the Shared Variable, which is hosted on the private network target,
and writes it to a different Shared Variable, which is hosted locally. Essentially,
Ethernet port 2 of the dual port controller is acting as a client of the Shared
Variable Engine on the private network target.
4. Run Dual Port Controller RT VI.vi
5. From the project, open Host PC VI.vi and view the Block Diagram. This VI
simply reads the value of the Shared Variable hosted on the dual port controller.
6. Now toggle the USER1 DIP switch on the private network target. The value
change will propagate to the dual port controller, and then to the host PC.

 
Congratulations! You are now successfully communicating between the host PC and
the private network target.
 