Faultfinding TrumaticC 10 GB
Faultfinding TrumaticC 10 GB
Faultfinding TrumaticC 10 GB
Design / components
Ignitor
10 / 20 Hz 50 Hz 35 Hz
Low setting Crushing
Input side 12 V
TrumaticC_10_GB – 07/10 – rb, Seite 13 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components Remote control
Electric safety and drain valve Continuous +
connection
Board
Connection at
Solenoid coil heater
cable harness
Microswitch
Do not kink
drain hose,
Articulated lever route downwards.
Extension cable
Cut off end of drain
hose at an angle
TrumaticC_10_GB – 07/10 – rb, Seite 14 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components
Elasi remote control
Locking
indicator
Electric
opener
Off position
TrumaticC_10_GB – 07/10 – rb, Seite 15 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components
Control panels
Control panel
as of 05/02
Summer operation
40/60 °C
Off position
Difference between
series 1 and series 2 Winter operation
is lettering without water
reheating
Winter operation
with water
reheating
Technical Information:
Lighting:
12 V / 145 mA (Standard)
Replace bulb if voltage is 24V.
Programming:
3 switch-on times in
7 day period
Switch-on duration max. 2 hours
TrumaticC_10_GB – 07/10 – rb, Seite 17 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components
Recirculated air fan
up to 06/01 for External housing
C 3402 / C 6002 separation (old)
Possible production
of odours with
housing up to 06/01
(external separation)
TrumaticC_10_GB – 07/10 – rb, Seite 18 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components Internal housing
Recirculated air fan separation
as of 07/01
(Serial no. 12200001)
Fuse F2 1,25 AF
status actuell fixed fuse
Cable
Fuse F1 4 AT
harness J9
Connection 12 V
Cable
Voltmeter ground
harness J1
TrumaticC_10_GB – 07/10 – rb, Seite 20 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components
C 3402 electronics overview
DC motor
with red/black
connecting cable
34000-70500
(like C 6002 up to 06/01)
Electronic C 34 E/1
Electronic C 34/2 kW var. /3 /4 as of 05/02
up to 04/02 Spare part for electronics
C 34/2 kW var. /3 /4
TrumaticC_10_GB – 07/10 – rb, Seite 21 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components Room sensor
C 4002 electronics connector contacts
Designation
Control panel
as of 09/06:
connector J2
ROHS
C40E/5/6 = lead-free
BF /
C40E/3/4 = not
lead-free
C40E/1/2 = not
lead-free, no F3
Accessory
connector J3
Input fuse
F1 6.3 AT Cable harness
12 V connection connector J9
TrumaticC_10_GB – 07/10 – rb, Seite 23 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Design / components Room sensor
electronic C 6002 connector contacts
Designation
as of (05/07): Control panel
C60E/5/6 = lead-free connector J2
ROHS
BF /
C60E/3/4 = not
lead-free
C60E/1/2 = not
lead-free, no F3
C60D/1 = more powerful
air circulation motor
C60/2/3/4 = for
motor with red/black
cable
Accessory connectorJ3
Control panel fuse
F3 1,6 AT Cable harnness
Input fuse F1 6,3 AT connector J9
Electronics
C 60 E/5 BF
C 60 / 2 kW electronics C 60 D/1 electronics C 60 E/1/2/3/4
C 60 E/6 ROHS
var. /3 /4 up to 06/01 (for more powerful electronics (for
lead-free
DC motor) more powerful
Must not be replaced from 07/01 to 04/02 DC motor) from 05/02
Must not be used as
with electronics spare part for other
C 60 E/1/2/3/4/5/6 or Spare part for
electronics.
C 60 D/1 C 60 D/1 electronics
TrumaticC_10_GB – 07/10 – rb, Seite 26 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Electronic system, control panel and remote/room sensor combinations
Room sensor needed
Control panel as of 05/02
Adapter Room sensor (FFC 2)
Electronic
system
up to 04/02 + Connecting cable
TrumaticC_10_GB – 07/10 – rb, Seite 27 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Electronic system, control panel and remote/room sensor combinations
Remote sensor accessories
Control panel up to 04/02
Remote sensor old version
Cut off jack
Electronic Cut off temp.
from remote sensor
system sensor beneath
as of 05/02 transparent
and crimp a flat
+ cap
connector onto the
- cable.
Electronic
system
up to 04/02
TrumaticC_10_GB – 07/10 – rb, Seite 28 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Electronic system, control panel and remote/room sensor combinations
Room sensor accessories
Control panel up to 04/02
Adapter Room sensor (FFC 2)
Electronic
system + Connecting
up to 04/02 cable
TrumaticC_10_GB – 07/10 – rb, Seite 29 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Electronic system, control panel and remote/room sensor combinations
Control panel up to 04/02
Electronic
system The sensor in the control panel
up to 04/02 deals with temperature control
Standard up to 04/02
TrumaticC_10_GB – 07/10 – rb, Seite 30 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Connection Drawing
Connection 10 A
+
-
Connecting the 12 V power supply
Attention:
Do not disconnect the connectors from the
electronics until the power supply has been
12 V
Gas pipe switched off. Connect heater to fuse
protected vehicle power supply with a
Pipe clip 2x2.5 mm2 cable (up to 6 m long) or
2x4 mm2 cable (6 m or above in length). Central ground
If the heater is being directly connected
Pressure
to the battery, the positive and negative
regulator
leads must have fuse protection. The
heater must be disconnected from the 12 V
Gas vehicle power supply when welding work
cylinder is being carried out on the body.
Vehicle frame
Ground
TrumaticC_10_GB – 07/10 – rb, Seite 31 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Basics of summer operation Normal Mode
2 Heat up water (2kW setting)
Burner start-up Solenoid valve opens
Room thermostat without function;
Gas flow starts
1 D.C. motor will not start; Ignitor active
undervoltage detection;
Flame created
Pre-purge time - 18 seconds;
Flame monitoring active
Residual gases are blown out
4 6 8 3 Fault no flame
Re-ignite for 10 sec.
Shut-off
Reset fault
manually
Water temperature
5 90 °C – 95 °C (WTS)
Burner safety shut-off
7 Air temperature
190 °C +/- 5 °C (LTS)
Burner safety shut-off
Note
The WTS and LTS switches only open if the WTF and LTF sensors are defective.
TrumaticC_10_GB – 07/10 – rb, Seite 33 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Basics of winter operation without controlled water temperature Normal Mode
Burner start-up Heating
Room thermostat 5 – 30 °C;
2 Solenoid valve opens
1 D.C. motor starts; Gas flow starts
Low-voltage detection; Ignitor active; flame created
Pre-purge time 18 seconds; Flame monitoring active
Residual gas is blown out autom. load regulation active:
C 34: 2kW – 3,4 kW
C 40: 2kW – 4 kW
C 60: 2 kW – 4 kW – 6 kW
4 6 8 Automatic
Room temperature 5 – 30 °C
restart
10 reached
when temp. deviates 3
D.C. motor shut off
by 0,5 °C from
burner shut-off
set room temp.
Air overtemperature LÜT reached
5 (LTF) ULM-coasting
Burner shut-off at 150 °C
Burner cut-in at 120 °C
4 6 8 3 Fault no flame
Re-ignite for 10 sec.
Shut-off
Note
The WTS and LTS switches only open if the WTF and LTF sensors are defective.
TrumaticC_10_GB – 07/10 – rb, Seite 35 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Basics of winter operation with controlled water temperature Normal Mode
Burner start-up 2 Heating
Room thermostat 5 – 30 °C; Solenoid valve opens
D.C. motor starts; Gas flow starts
1 Ignitor active; flame created
Low-voltage detection;
Pre-purge time 18 seconds; Flame monitoring active
Residual gas is blown out autom. load regulation active:
C 34: 2kW – 3,4 kW
C 40: 2kW – 4 kW
C 60: 2 kW – 4 kW – 6 kW
3 Room temperature 5 – 30 °C
5 7 Automatic reached
restart D.C. motor shut off (LTF)
9
when temp. deviates burner shut-off if
by 2 °C from water temperature reaches (WTF)
set room temp.
or Air overtemperature LÜT reached
water temperature (LTF) ULM-coasting
4
Burner shut-off at 150 °C
Burner cut-in at 120 °C
8 Water temperature exceeded
6 Water overheat condition WÜT
(WTF), ULM after-run reached (WTF)
D.C. motor on at 62 °C ULM-cont.running
D.C. motor off at 60 °C Burner locked at 77 °C
as of year of manufacture 2005 Burner released at 68 °C
TrumaticC_10_GB – 07/10 – rb, Seite 36 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Basics of winter operation with controlled water temperature Lockout
1 2
Burner start-up Heating
4 6 8 3 Fault
no flame
Re-ignite for 10 sec.
Shut-off
Reset fault
5 Air temperature
manually
190 °C +/- 5 °C (LTS)
Burner safety shut-off
7 Water temperature
90 °C – 95 °C (WTS)
Burner safety shut-off
Note
The WTS and LTS switches only open if the WTF and LTF sensors are defective.
TrumaticC_10_GB – 07/10 – rb, Seite 37 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Elasi - + (30)
Wiring diagram
Connector J1
Large magnetic coil
As of 05/02 AW HW
Voltage
connection
on electronics
(parallel to cable - +
harness)
1 2 4 5 7 8 9 10 11 12 14 16 18 20
J1 3 6 13 15 17 19
- +
Ignitor Motor Motor
- +
-
AW HW Recirculated
Combustion
Housing ground air
Small magnetic coil
TrumaticC_10_GB – 07/10 – rb, Seite 38 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Wiring diagram
Connector J9
LTS
190°C
C 4002
bn
bn
2 3 4 6 7 8 9 10 11 12
J9
1 5
gr
ge
ge
gn
gn
or
gr
or
90°C
TrumaticC_10_GB – 07/10 – rb, Seite 39 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Pre-purge flow diagram
J1-1
J1-4
F1
J9-11 J9-4
Combustion air
temperature sensor
TrumaticC_10_GB – 07/10 – rb, Seite 40 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Summer operation flow diagram
J1-1 Fault signal Flame
5-10 sec. monitoring
J1-4
-0,65 V
F1
J1-7 J1-19
J1-8 Pre-purge time
Ignitor
18-20 sec.
F2 1 Hz
clock Speed Solenoid valve
monitor shutt-off
J2-10 J2-4 Under-
Water VBLM
voltage 10,5V temperature J9-2
sensor
Water temperature
monitor (WTW)
J9-11 J9-4 90-95 °C
J9-3
Combustion air
temperature sensor
J9-5
(bei C 4002
J9-12 J9-6 J1-11 Air temperature J9-7)
switch (LTS)
190 °C
J9-1
J1-14 Restraining J1-16
Changeover
coil
2 kW
310-340 Ω
J1-12
Attracting
coil 8-9 Ω
TrumaticC_10_GB – 07/10 – rb, Seite 41 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Winter Operating Heating Flow Diagram
J1-1 Fault Flame
signal monitoring
J1-4 5-10 sec.
-0,65 V
F1
J1-7 J1-19
J1-8 Pre-purge time
Ignitor
18-20 sec.
F2 1 Hz
clock Speed Solenoid
monitoring valve shut-off TIST-
TSOLL
J2-10 J2-4 Undervoltage
VBLM
10,5 V J9-2 Motor
control
Water temperature
J2-7 monitor (WTW)
Activating
winter operating
J9-11 90-95 °C
J9-10
J9-3
Combustion air LTF
temperature sensor
J9-5
(bei C 4002
J9-12 J1-11 J9-8
Air temperature J9-7)
switch (LTS)
190 °C
J1-18
J9-1
J1-14 Restraining J1-16 J1-17 Restraining
J1-15 Umluft-
Changeover Changeover
coil coil motor
2 kW 3,4 / 4 kW
310-340 Ω 310-340 Ω
TrumaticC_10_GB – 07/10 – rb, Seite 42 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Flow diagram, heating and hot water re-heating in winter operation
J1-1 Fault Flame
signal monitoring
J1-4 5-10 sec.
-0,65 V
F1
J1-7 J1-19
J1-8 Vorspülzeit
Ignitor
18-20 sec.
F2 1 Hz
clock Drehzahl- Magnetventil-
überwach. abschaltg. TIST-
TSOLL
J2-10 J2-4 Undervoltage
Water VBLM
10,5 V
temperature J9-2 Motor
sensor control
Water temperature
J2-7 monitor (WTW)
Activating
winter
J9-11 J9-4 90-95 °C
operating
J9-10
J9-3
Combustion air LTF
temperature sensor
J9-5
(bei C 4002
J9-12 J9-6 J1-11 J9-8
Air temperature J9-7)
switch (LTS)
190 °C
J1-18
J9-1
J1-14 Restraining J1-16 J1-17 Restraining
J1-15 Umluft-
Changeover Changeover
coil coil motor
2 kW 3,4 / 4 kW
310-340 Ω 310-340 Ω
TrumaticC_10_GB – 07/10 – rb, Seite 44 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Measuring Sheet with J9 connector disconnected - measurement
of temperature monitors and switches (Heater switched off)
Component Contact plug J9 measuring Setpoint (kOhms) Remark
point
LTS (190 °C) Measure and check for Connection / 0 Switch must
Air temperature connection between J9-1 bn be closed
switch and J9-5 bn
WTW (95 °C) Measure and check for Connection/ 0 Switch must
Water temperature connection between J9-2 ge be closed
switch (yellow and J9-3 ge
strand)
WTF Measure resistance between 0 °C = 35,563 Resistance
Water temperature J9-4 or and J9-6 or 10 °C = 20,860 value (NTC)
sensor (orange 20 °C = 12,683 is
strand) 25 °C = 10,000 temperature-
30 °C = 7,942 dependent Connectors J9-1 to J9-12
40 °C = 5,074
50 °C = 3,336
LTF Measure resistance between 0 °C = 326,500 Resistance LTF
Air temperature J9-8 gn and J9-10 gn 10 °C = 199,000 value (NTC) LTS
sensor 20 °C = 124,900 is
25 °C = 100,000 temperature-
30 °C = 80,570 dependent
40 °C = 53,270
50 °C = 36,030
VBLTF Measure resistance between 0 °C = 28,250 Resistance VBLTF
Combustion J9-11 gr and J9-12 gr 10 °C = 18,361 value (NTC)
temperature 20 °C = 12,161 is
25 °C = 10,000 temperature-
30 °C = 8,276 dependent WTW
40 °C = 5,736
50 °C = 4,067 WTF
TrumaticC_10_GB – 07/10 – rb, Seite 45 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Measuring Sheet with J1 connector connected
Electrical consumer measurement (heater switched on)
TrumaticC_10_GB – 07/10 – rb, Seite 46 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
Values of resistance of the room temperature sensor
(Do not measure while wired)
TrumaticC_10_GB – 07/10 – rb, Seite 47 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications
Trumatic C
DC motor C 4002 / C 6002 (EH)
TrumaticC_10_GB – 07/10 – rb, Seite 48 Copyright by Truma Gerätetechnik, Putzbrunn Right reserved to make technical modifications