DSHG 06
DSHG 06
DSHG 06
These valve are used for shifting oil flow direction of hydraulic circuit and for actuator starting/stopping as well as the
operating direction shifting of actuator.
Hydraulic Fluids
1. Type of Fluids
Any type of hydraulic fluid, listed in the table below can be used.
Directional Valves
DSG-005 series Solenoid Operated Directional Valves 20 – 200 mm2/s –15 – +60°C
(100 – 900 SSU) (5 – 140°F)
Solenoid Operated Directional Valves
Solenoid Controlled Pilot Operated Directional Valves
Poppet Type Solenoid Operated Directional Valves
Multi Purpose Control Valves
Solenoid Operated Poppet Type Two-Way Valves 15 – 400 mm2/s –15 – +70°C
Pilot Controlled Directional Valves (80 – 1800 SSU) (5 – 160°F)
Manually Operated Directional Valves
Mechanically Operated Directional Valves
Check Valves
Pilot Controlled Check Valves
G Series Shockless Type Solenoid Operated Directional Valves 15 – 200 mm2/s –15 – +60°C
(Shifting Time Adjustable) (80 – 900 SSU) (5 – 140°F)
3. Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorter the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
12. Use 25 µm or finer line filter (In case of DSG-005 series Solenoid Operated Directional Valves, NAS1638-Grade
11. Use 20 µm or finer line filter).
Compliance
(S-/T-/L-)DSG-01
DSHG-01 G-DSG-01
DSLG
Item Standard Type Description DSHG-03 E-DSG-01 G-DSG-03
DSG-005 (S-)DSHG-04 (S-/E-/T-/L-) G-DSHG-04 DSLHG CDS❇
(S-)DSHG-06 DSG-03 G-DSHG-06 DSP❇
(S-)DSHG-10
JIS F8001 Class 1 water spray Drip-proof construction
Water-proof test
for marine Class 2 water spray Froth-roof construction
electric appliance
Damp-proof test M1 Test to examine damp-resistance of parts
JIS D0203 Damp-proof test M2 Test to examine functions of part under high
temperature and high humidity
Damp-proof and
Water-proof test
for automobile Splash-proof test R1 Test to examine functions of parts which are
likely to be exposed to water splash.
parts
Splash-proof test R2 Test to examine functions of parts which are
indirectly exposed to stormy weather or water splash.
★2 JIS C0920 Drip-proof type Not affected by water dropping at vertical angle of 15 degrees or less.
Water-proof Water-proof test
for electro- Rain-proof type Not affected by rain fall at vertical angle of 60 degrees or less.
mechanical parts Froth-proof type Not affected by water drip from any dirction.
an wiring
materials Jet-flow proof type Not affected by jet flow from any direction.
Protection Class 2: Not affected by water drip falling at vertical angle of
Drip-proof type (2) 15 degrees or less.
Protection Class 3: Not affected by rain falling at vertical angle of 60
(I.E.C) Rain-proof type degrees or less.
PUBL. 529 Protection Class 4: Not affected by water drip from any direction.
Froth-proof type
Protection Class 5: Not affected by jet flow from any direction.
Jet-flow proof type
(I.E.C)
Dust-proof Protection Class 6 Fully protected from entry of dust.
PUBL. 529
Vibration range: 7-59.5 Hz
Resonace test (IC) Duplex amplitude: 0.1 mm
Grade 1: duplex amplitude-0.5 mm
JIS C0911 Fixed frequency Grade 2: duplex amplitude-1.2 mm (2D✻)★1 (2D✻)★1 ★1
Frequence: 20 Hz
Vibration test for resistance test (IIC) Grade 3: duplex amplitude-1.8 mm (2D✻)★1 (2D✻)★1 ★1
small electric
appliances Grade 4: duplex amplitude-2.4 mm (2D✻)★1 (2D✻)★1 ★1
Vibration-
resistance Grade 1: duplex amplitude-0.3 mm (2D✻)★1 (2D✻)★1 ★1
Variable frequency
Frequency range: 7-59.5 Hz
Grade 2: duplex amplitude-0.5 mm (2D✻)★1 (2D✻)★1 ★1
resistance test (IIIC)
Grade 3: duplex amplitude-0.75 mm (2D✻)★1 (2D✻)★1 ★1
Grade A: Parts mounted on spring of body or chassis
JIS D1601 Class 1: having relatively low vibration. (2D✻)★1 (2D✻)★1
Vibration test for mainly for parts of
automobile parts passenger car Grade B: Parts mounted on spring of body or chassis
having relatively low vibration. (2D✻)★1 (2D✻)★1
Grade C: Parts mounted in engine having relatively low (2D✻)★1 (2D✻)★1
vibration
★1 : No-spring detented type (2D✻) and No-spring type (2N✻) can be used when energised continous for position holding.
★2 : For outdoor use, protect equipment with a cover, etc., to prevent direct exposure to water.
Maximum Flow
Max. U.S.GPM
Operating .3 .5 1 2 5 10 20 50 100 200 500 1000
Valve Type Graphic Symbols Pressure Page
1 2 5 10 20 50 100 200 500 1000 2000 5000
MPa (PSI) L /min
25 (3600) DSG-005 336
16 (2320) L-DSG-01
25 (3600) S-DSG-01 344
Solenoid Operated A B
Manually Operated
A B 21 (3050) Threaded Connection (DMT) 03 06 10 429
Directional Valves 31.5 (4580) Sub-plate connection (DMG) 01
P T 03 04 06 10
A B
Mechanically Operated
7 (1020) Rotary (DR T
G) 02
P T
A
441
Directional Valves B
P T
25 (3600) Cam Operated (DC T
G) 01 03
A B
2 Holds pump pressure and cylinder position at neutral. Care
should be paid if used as a 2-position type because shock
( Closed Centre
All Ports ) P T
occurs when each port is blocked in transit.
T B P A
A B
3 Pump can be unloaded and actuator is floating at neutral.
( Open Centre
All Ports ) P T
If a 2-position type is used, shock is reduced as each ports is
released to tank in transit.
T B P A
40 A B
In a variation of spool type “4”, a restrictor is provided in A-T
( Open Centre A, B&T
Restricted Flow ) and B-T ports. Making it faster at stopping the actuator.
P T T B P A
A B
5 It can be used when a pump is unloading at neutral and actuator
(Open Centre P, A&T) is halted at one way flow.
P T T B P A
A B
6 Pump is unloading and actuator position held at neutral.
( Open Centre P&T
Closed Crossover ) P T
Suitable for series operation.
T B P A
A B
60 It is a variation of spool type “6”.
( Open Centre P&T
Open Crossover ) Shock is reduced as each port is released to tank on transit.
P T T B P A
A B
7
( Open Centre All Ports
Restricted Flow ) Mainly used as a 2-position type. Shock is reduced on transit.
P T T B P A
A B
Pump pressure and cylinder position is held at neutral in the
8
same way as spool type “2”.
(2-Way)
It is used as 2 way type.
P T T B P A
A B
9 Regenerative circuit is provided at neutral.
(Open Centre P, A&B)
P T T B P A
A B
10 Prevent actuator from one direction drift by leakage of P port at
(Open Centre B&T) neutral.
P T T B P A
A B
11 Halt actuator movement positively at B, T ports blocked P, A
(Open Centre P&A) ports connected at neutral.
P T T B P A
A B
12 Prevent actuator from one direction drift by leakage of P port at
(Open Centre A&T) neutral.
P T T B P A
■ Mounting Surface
Mounting surface dimensions conform to ISO 4401, Hydraulic fluid power-Four-Port directional control valves-
Mounting surfaces.
()
S–
L–
E– DSG–01
T–
G– ISO 4401–AB–03–4–A
DSHG–01
DMG–01
DCG–01
()
S–
L–
E– DSG–03
T– ISO 4401–AC–05–4–A
G–
DMG–03
DCG–03
E
DSHG–03 ISO 4401–AC–05–4–A✻
( )
S– DSHG–04
G– ISO 4401–AD–07–4–A
DHG–04
DMG–04
( )
S– DSHG–06
G–
ISO 4401–AE–08–4–A
DHG–06
DMG–06
(S–) DSHG–10
Directional Valves
DHG–10 ISO 4401–AF–10–4–A
DMG–10
✻ The main port conform to the ISO 4401–AC–05–4–A.
The pilot and drain ports is sccordance with the ISO original draft.
S H
1100
(291)
H : High Pres., High Flow, Low Pres. Drop Type
(S–)DSHG–10
S : Shockless Type
300
(79.3)
(S–)DSHG–04
250
(66.1) G–DSHG–06
G
S
160
(42.3)
P
DSHG–03 G–DSHG–04
S H
120
(31.7)
S–DSG–03 DSG–03 H
100
(26.4) G DSG–01
80
(21.1)
G–DSG–03
E S
63
(16.6)
E–DSG–03 S–DSG–01
L-DSG-03 [60 L/min (15.9 U.S.GPM)]
S G
E
40
(10.6) E–DSG–01 DSHG–01 G–DSG–01
E
30
(7.9)
E–DSG–01
15
(4.0) DSG–005
0 16 21 25 31.5 35
(2320) (3050) (3630) (4570) (5080)
Instructions
● Mounting
DSG-005 No mounting restrictions for any model.
-DSG-01 No-spring detented models not energised continuously must be installed so that
-DSG-03 the spool axis L-L’ is horizontal. Otherwise there is no mounting restrictions. L L’
-DSG-01/03
DSHG-01
DSHG-03
(S-) DSHG-04 No-spring models not energised continuously must be installed so that the spool
(S-) DSHG-06 axis L-L’ is horizontal. Otherwise there is no mounting restrictions. ,
(S-) DSHG-10 L L
-DSHG
● Energisation
1. No-Spring Type
E
One of two solenoids should be energised continuously to avoid malfunction.
2. On double solenoid valves do not energise both at the same time as it will result in coils burning out.
● Valve Tank Port
Avoid connecting the valve tank port to a line with possible surge pressure.
Piping end of tank line should be submerged in oil.
Directional Valves
100 r DS
Operating
Only after the tank line has been filled with operating oil should the 20 pt fo
exce
Force
Solenoid
■ Solenoid connector (DIN connector) ■ R type Models with Current Rectifier and DC
The solenoid connector is in accordance with the Solenoid
international standard ISO 4400 (Fluid power systems Specially designed DC solenoid and receptacle (or
and components-Three-pin electrical plug connectors- connector) containing AC-DC rectifier and transient
Characteristics and requirements). peak suppressor are provided. Connection to be made
■ AC Solenoid to AC power source as with conventional AC solenoid.
Remarkably high reliability and long life and other
50-60 Hz common service solenoids do not require re-
advantages including quiet valve operation. No over-
wiring when the applied frequency is changed. heating of coil due to the spool sticking and protection
■ DC Solenoid ( -series Solenoid Operated against transient voltage peaks are assured.
Directional Valve) ■ RQ type Models with Current rectifier and Quick
These valves differ from conventional DC solenoid Return Solenoid
operated directional valves and have the following Valve characteristics are identical to R type except for
characteristics: the fast return time of the spool after deenergisation.
1. The spark between the relay contacts has been
■ Insulation Class of Solenoid
eliminated and therefore the valve can be operated by
miniature relays. Model numbers Insulation Class
2. The surge voltage is approximately 10 % of that
DSG-005, DSG-01, S-DSG01
normally experienced. L-DSG-01, E-DSG-01, T-DSG-01
3. Time lag on de-energisation is reduced by DSG-03, S-DSG-03, L-DSG-03 Class H
approximately 50 %. E-DSG-03, T-DSG-03
DSHG-01/03/04/06/10, S-DSHG-04/-06/10
G-DSG-01, G-DSG-03 Class F
Specifications
Solenoid Controlled
DSHG-01-3C - -14/1480/1490 3.2 (7.1)
40 (10.6) 21 (3050) 21 (3050) 1.0 (145) 16 (2320) 16 (2320) 120 120 120
DSHG-01-2B - -14/1480/1490 2.7 (6.0)
DSHG-03-3C - -14/1490 6.9 (15.2)
DSHG-03-2N - -14/1490 160 (42.3) 25 (3630) 25 (3630) 0.7 (100) 16 (2320) 16 (2320) 120 120 120 6.9 (15.2)
Standard DSHG-03-2B - -14/1490 6.4 (14.1)
Type (S-)DSHG-04-3C - -52/5290 8.5 (18.7)
(S-)DSHG-04-2N - -52/5290 300 (79.3) 31.5 (4570) 25 (3630) 0.8 (120) 21 (3050) 16 (2320) 120 120 120 8.5 (18.7)
(S-)DSHG-04-2B - -52/5290 8.0 (17.6)
(S-)DSHG-06-3C - -53/5390 ★3
12.4 (27.3)
(S-)DSHG-06-2N - -53/5390 25 (3630) 0.8 (120) 120 120 120 12.4 (27.3)
500 (132) 31.5 (4570) 21 (3050) 16 (2320)
(S-)DSHG-06-2B - -53/5390 11.9 (26.2)
Shockless (S-)DSHG-06-3H - -53/5390 21 (3050) 1.0 (145) 110 110 110 13.2 (29.1)
Type (S-)DSHG-10-3C - -43/4390 120 120 100 45.0 (99.2)
25 (3630)
(S-)DSHG-10-2N - -43/4390 ★3 100 100 100 45.0 (99.2)
1100 (291) 31.5 (4570) 1.0 (145) 21 (3050) 16 (2320)
(S-)DSHG-10-2B - -43/4390 44.5 (98.1)
21 (3050) 60 60 50
(S-)DSHG-10-3H - -43/4390 52.9 (116.6)
★1. Maximum flow indicates a ceiling flow. As the ceiling flow depends on the type of
spool and operating condition, refer to the List of Spool Functions on pages 386 to 390 Yuken can offer flanged connection valves described below.
for details. Consult us for the details.
★2. Pilot pressure of internal pilot drain models must always exceed tank line back pressure Rated Flow Max. Pressure
by a minimum required pilot pressure. Model Numbers
l/min (U.S.GPM) MPa (PSI)
★3. Min. pilot pressure of with pilot piston in 1.8 MPa (260 PSI).
DSHF-10- - -27 315 (83) 21 (3050)
DSHF-16- - -37 500 (132) 21 (3050)
■ Solenoid Ratings DSHF-24- - -28 1200 (317) 21 (3050)
Solenoid ratings of pilot valve are identical with those of standard solenoid DSHF-32- - -27 2400 (634) 21 (3050)
valve. Refer to relevant solenoid ratings described on the page below.
Model Pilot Valve Model Solenoid Ratings described
Numbers Numbers on the page below CSA Approved Solenoid Valve
DSHG-01
Available to supply DSHG-06 series valve approved
DSHG-03 by the CSA (Canadian Standards Association).
(S-)DSHG-04 DSG-01- - -70 345 Consult us for details.
(S-)DSHG-06
(S-)DSHG-10
2, 3, 4
C: 40, 5, 60
3
Spring Centred 7, 9, 10
01 11, 12
B: 2, 3, 4
2
Spring Offset 40, 7
None: 2, 3, 4
Standard 3 C: 40, 5, 60
Type Spring Centred 7, 9, 10
11, 12
03
N: 2
F: No-Spring 3
For DSHG: 2 4
Phos- Solenoid B: 40
Controlled Spring Offset 7 None: None:
phate C1 : Internal External
Ester Pilot
Operated 2, 4, 40 With C1 Pilot Drain
Type Choke
Directional 3 C: 60, 10, 12
Fluids ★1
Spring Centred 3, 5, 6
Valve, ( )
(Omit
required )
if not
Sub-plate
Mounting 04
7, 9, 11 C2 :
With C2
E:
External
E:
Internal
N: 2, 4, 40 A ★2 Drain
(3, 7) ★1 Choke Pilot
No-Spring (Omit if not required)
2
★2
B: 2, 4, 40 A B★2
None: Spring Offset (3, 7) ★1 (Omit if not required)
C1C2 :
Standard With C1 &
Type H: 2, 4, 40 C2 Choke
Pressure Centred 60, 10, 12
06 3 3, 5, 6 ★1
S: C: (7, 9, 11 )
Shock-
less
Spring Centred (Omit
required )
if not
Type N: 2, 4, 40 A ★2
No-Spring (3, 7) ★1 (Omit if not required)
10 2
B: 2, 4, 40 A
★2
B★2
Spring Offset (3, 7) ★1 (Omit if not required)
Note: In spool type “3”, “5”, “6”, “60”, and “7”, the combination applicable between pilot system and drain system is as described in the table below.
AC: 14 None:
A100 , A200 Japanese
A120 , A240 Standard L
"JIS" (Omit if not required)
DC:
D12 , D24
D48
R2 : None:
AC → DC Terminal
With Stroke 90:
R100 , R200 Box Type
E
Adjustment, None : 14 N.
Both Ends Manual American
Override Design
RA : Pin Standard
With Stroke L
(Omit if not required)
Adjustment,
Port "A" End
RB : None:
With Stroke Japanese
Solenoid Controlled
A120 , A240 Button & N: Standard L
Lock Nut Push-in (Omit if not required)
DC: Connector
D12 , D24 Type 80:
R2 : With Stroke Adj., D48 European
Both Ends 53 Design
RA : With Stroke Adj., AC → DC H: Standard
Port "A" End R100 , R200 Refer to ★5
N1 : (Applicable
RB : With Stroke Adj., Push-in
★4 only for
Port "B" End Connector DSHG-01)
P2 : With Pilot Piston, with
Both Ends 90:
Indicator
N.
PA : With Pilot Piston, Light 43 American L
Port "A" End
Design (Omit if not required)
PB : With Pilot Piston, Standard
Port "B" End
★1. Shekless type (S-DSHG) are not available for spool type marked ( ).
★2. As for the details of the valve using the neutral position and the side position (either SOL a or SOL b side), please refer to page 391.
Furthermore, the spool types other than “2”, “4”, “40” (3, 7) are also available.
★3. In spool-spring arrangement “H” (Pressure centred models), the valves with stroke adjustment (R*) and pilot-piston (P*) are not available.
★4. NI stands for Plug-in connector with solenoid indicator light. NI is not available for R-type solenoids.
★5. In spool-spring arrangement “H” (pressure centred models), in case the pilot pressure is more than 10 MPa (1450 PSI), please specify that the
valve should have the built-in orifice to the pilot line.
In the table above, the symbols and numbers highlighted with shade represent the optional extras.
The valves with model number having such optional extras are handles as options, therefore
please confirm the time of delivery with us before ordering.
Mounting Bolt
Mouting Bolt
Model
Japanese Standard "JIS" Tightening Torque
Numbers Name N. American Design Standard Qty.
European Design Standard Nm (in. 1bs.)
1
3 MBK-01-01-30 MBK-01-01-3090 1
DSHG-01 Mtg. Bolt Kit 2 1 set 5-6 (43 - 52)
MBK-01-02-30 MBK-01-02-3090 2
DSHG-03 Soc. Hd. Cap Screw M6 35 Lg. 1/4-20 UNC 1-3/4 Lg. 4 12 - 15 (104 - 130)
M6 45 Lg. 1/4-20 UNC 1-3/4 Lg. 2 12 - 15 (104 - 130)
(S-)DSHG-04 Soc. Hd. Cap Screw
M10 50 Lg. 3/8-16 UNC 2 Lg. 4 58 - 72 (504 - 625)
(S)-DSHG-06 Soc. Hd. Cap Screw M12 60 Lg. 1/2-13 UNC 2-1/2 Lg. 6 100 - 123 (868 - 1068)
(S)-DSHG-10 Soc. Hd. Cap Screw M20 75 Lg. 3/4-10 UNC 3 Lg. 6 473 - 585 (4106 - 5078)
Stud Bolt
"B " Thd.
Both Ends
9 9
(.35) (.35)
A
DIMENSIONS IN
MILLIMETRES (INCHES)
Nut "B " Thd.
MBK-01-01-30 94 (3.70 )
(.33)
M5
MBK-01-02-30 134 (5.28 )
MBK-01-01-3090 94 (3.70 )
No.10-24 UNC
4 MBK-01-02-3090 134 (5.28 )
9
(.16)
(.35)
15
(.59)
Options
Models with Pilot Choke Adjustment Pressure Centred Models (3H )
When the adjustment screw is turned clockwise, The pressure centered type can be used when the
changeover speed of the main spool becomes slow. In returning of the main spool to the neutral position is
case of the spring centred valves in particular, making required to be firmily.
slow of the returning speed of the main spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with the
valves of spring centred, no-spring, offset, pressure Graphic Symbols (Ex.: External Pilot-External Drain)
centred and the valves with stroke adjustment.
(Only for 3H6, 3H60)
Graphic Symbols (Ex.: Spring Centred) A B A B
a a
DSHG-01,06,10 P T
b b
C2 Choke Y V
X Y P T V X
C1 Choke
E
b a
Models with Stroke Adjustment (R2, RA, RB)
Y When the adjustment screw is screwed in , the main
P
T
spool stroke becomes short and flow rate reduces.
Graphic Symbols (Ex.: Spring Centred)
A B
"R2" Models
DSHG-03, 04
C2 Choke A B
a b
C1 Choke "RA" Models
Solenoid Controlled
Y
P A B
T a b
Y P T
A B
"RB" Models
A B
a b
Y P T
Models with Pilot Piston(P2, PA, PB)
The valves with a pilot piston can be used when the high
speed changeover of the main spool is required. Additional Mass of Options
However, please not that in case of spring centered
valves, there is no change in the returning speed of the Add the mass described below to the mass of standard
main spool to the neutral position even with the pilot models on page 381, if options are required.
piston.
kg (1bs.)
Graphic Symbols (Ex.: Spring Centred) Model with Pilot Models with Models with
Model Choke Adj. Pilot Piston Stroke Adj.
"P2" Models Numbers PA PA
C1, C2 C1C2 P2 P2
A B PB PB
a b
DSHG-03 0.65(1.4) 1.3(2.9) 0.6(1.3) 0.3 (.7)
W V
Y P T (S-)DSHG-04 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5 (1.1)
(S-)DSHG-06 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1) 1.2(2.6) 06 (1.3)
"PA" Models (S-)DSHG-10 0.65(1.4) 1.3(2.9) 3.6(7.9) 1.8(4.0) 3.7(8.2) 1.85 (4.1)
A B
a b
V
Y P T
Options on Pilot Valve
"PB" Models
The same options to DSG-01 series valves are available.
A B
Please refer to page 345 for the details.
a b
W
Y P T
A B A B SOL a
SOL b
APB
b APB a
P T X A B P T Y
X A B
Y
Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B).
(Example) In case of Spool Type "2"
E
Neutral Position
SOL. a Energised SOL. b Energised
Position Position
A B
a b
Y P T
Solenoid Controlled
Y P T Y P T
Graphic
Graphic Symbols Graphic Symbols
Symbols
Model Numbers Model Numbers Model Numbers
Standard Reverse Standard Reverse Standard
Mtg. Mtg. Type Mtg. Mtg. Type Mtg.
04 A B A B 04 A B A B 04 A B
b a b a a b
DSHG-06 -2B A DSHG-06 -2B B DSHG-06 -2N A
Y P T P T Y Y P T P T Y
10 10 10 Y P T
10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
410 (108) 310 (81.9) 420 (111)
"2" (S-)DSHG-06-3C2 500 (132) 500 (132) (S-)DSHG-06-3H2 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
"3" DSHG-06-3C3 500 (132) 500 (132) 460 (122) 370 (97.8) DSHG-06-3H3 500 (132) 500 (132) 500 (132) 500 (132)
"5" DSHG-06-3C5 500 (132) 500 (132) 425 (112) 350 (92.5) DSHG-06-3H5 500 (132) 500 (132) 500 (132)
470 (124)
500 (132)
420 (111)
E
"6" DSHG-06-3C6 475 (125) 390 (103) 300 (79.3) 230 (60.8) DSHG-06-3H6 500 (132) 500 (132) 500 (132)
500 (132)
420 (111)
"60" (S-)DSHG-06-3C60 475 (125) 420 (111) 340 (89.8) 280 (74.0) (S-)DSHG-06-3H60 500 (132) 500 (132) 500 (132)
500 (132)
"7" DSHG-06-3C7 500 (132) 500 (132) 450 (119) 360 (95.1) DSHG-06-3H7 500 (132) 500 (132) 500 (132) 500 (132)
Solenoid Controlled
"10" (S-)DSHG-06-3C10 500 (132) 500 (132) (S-)DSHG-06-3H10 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
410 (108) 310 (81.9) 460 (122)
"11" DSHG-06-3C11 500 (132) 500 (132) DSHG-06-3H11 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
410 (108) 310 (81.9) 460 (122)
"12" (S-)DSHG-06-3C12 500 (132) 500 (132) (S-)DSHG-06-3H12 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
Spool Type a b b
L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T
10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
"2" (S-)DSHG-06-2N2 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B2 500 (132) 500 (132) 500 (132) 500 (132)
"3" DSHG-06-2N3 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B3 500 (132) 500 (132) 500 (132) 500 (132)
"4" (S-)DSHG-06-2N4 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B4 500 (132) 500 (132) 500 (132) 500 (132)
"40" (S-)DSHG-06-2N40 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B40 500 (132) 500 (132) 500 (132) 500 (132)
"7" DSHG-06-2N7 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B7 500 (132) 500 (132) 500 (132) 500 (132)
Notes:1. The relation between max. flow and pilot pressure in the table above is as shown
below.
(Example) Pilot Pressure at 0.8 MPa (120 PSI).
410 (108) In case pressure centred models, pilot pressure
Maximum flow rate is constant regardless of pilot pressure. 500 (132) is more than 1 MPa (150 PSI)
Pilot Pressure more than 0.8 MPa (120 PSI). 500 (132)
In case pressure centred models, pilot pressure is more than Pilot Pressure at 1.5 MPa (220 PSI).
1 MPa (150 PSI).
2. Max. flow in the table above represents the value in the flow condition of P A
B T (or P B A T) as shown in the circuit diagram right. A B
In case the valve is used in the condition that either A or B port is blocked, the a b
maximum flow differs according to a hydraulic circuit, therefore, please consult us
P T
for details.
DSHG-06, S-DSHG-06
DSHG-06
1
PSI MPa 2 Pressure Drop Pressure Drop
300 2.0 Spool Spool
3 Curve Numbers Curve Numbers
Type Type
P
250 4 P AB TP BA TP T P AB TP BA TP T
1.6
Pressure Drop
200 5 2 8 5 8 7 60 6 5 6 7 1
1.2 3 6 4 6 7 4 7 6 4 6 7
150 6
0.8 7 4 8 5 8 7 9 6 5 6 7
100
40 8 5 8 7 10 8 5 8 7
50 0.4 8
5 8 4 5 7 1 11 8 4 5 7
0
0 6 5 3 5 4 1 12 8 5 8 7
0 100 200 300 400 500 L /min
E
Type Type
P AB TP BA TP T P AB TP BA TP T
2 6 1 6 2 60 6 2 6 3 1
4 6 2 6 2 10 8 5 8 7
40 8 5 8 7 12 8 5 8 7
DSHG-10, S-DSHG-10
Solenoid Controlled
4
P
250
1.6
P AB TP BA TP T P AB TP BA TP T
5 2 9 6 9 8 60 8 5 8 5 3
Pressure Drop
200
1.2 6 3 7 6 7 7 5 7 7 6 7 7
150
7 4 9 6 9 6 9 7 6 7 8
0.8
100 8 40 9 6 9 8 10 9 5 9 8
50 0.4 9 5 9 6 8 6 1 11 9 6 8 7
0
0 6 5 3 5 2 2 12 9 7 9 6
0 200 400 600 800 10001100 L /min
For any other viscosity, multiply the factors in the table below.
mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity
SSU 77 98 141 186 232 278 324 371 417 464
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula right.
P' = P(G'/0.850)
Test Conditions
Coil Type : D (Models with DC solenoids)
Voltage : Rated Voltage
Oil Viscosity : 35 mm 2/s (164 SSU)
DSHG-04 DSHG-10
ms ms
250
150
3C
SOL"ON"
Changeover Time
SOL"OFF" 200
100
2B
SOL"ON" 3C
Changeover Time
2N SOL"OFF"
SOL"OFF" 150
50 SOL"ON"
2B
2N SOL"ON","OFF"
0 100
0 5 10 15 20 25 MPa
50
0 1000 2000 3000 3600 PSI
Pilot Pressure 0
0 5 10 15 20 25 MPa
DSHG-06
0 1000 2000 3000 3600 PSI
ms
150
Pilot Pressure
3C
SOL"ON"
Changeover Time
SOL"OFF"
100
2B
2N SOL"ON"
SOL"OFF"
50
0
0 5 10 15 20 25 MPa
Pilot Pressure
Mounting surface:
Terminal Box Type: (S-)DSHG-06- - -53/5390 ISO 4401-AE-08-4-A
Solenoid Indicator Light Pressure Port "P"
Tank Port "T"
255(10.04) Pilot Drain Port "Y"
(For External Drain Models Only)
13.5(.53) Dia. Through 50.5 130.2
20(.79) Dia. Spotface (1.99) (5.13)
53.2 Model Numbers "C" Thd.
6 Places
(2.09)
T P Y (S-)DSHG-06- - -53 G 1/2
(S-)DSHG-06- - -5390 1/2 NPT
(3.63)
(4.65)
L L′
92.1
118
(1.81)
46.1
X A B
Pilot Pressure Port "X"
(For External Pilot Models Only) 77
(.51)
13
(3.03) 156
Cylinder Port "A" (6.14) Cylinder Port "B"
AC :196.4(7.73)
DC,R:204.4(8.05)
95
AC :45.5(1.79) Space Needed to Remove
DC,R:50(1.97) Solenoid-Each End
AC :50.7(2.00) 46
E
(3.74) DC,R:54.7(2.15) (1.81) Electrical Conduit Connection
Double Solenoid "C" Thd. (Both Ends)
Models Only
Manual Actuator
SOL a SOL b 6(.24) Dia.
200.8(7.91)
APB
182.5(7.19)
135.5(5.33)
Nut
L L′
(1.61)
Solenoid Controlled
41
(O-Rings Furnished)
DIMENSIONS IN
MILLIMETRES (INCHES)
Plug-in Connector Type: (S-)DSHG-06- - - N -53/5390
N1
Cable Departure
H Cable Applicable:
Outside Dia. ...... 8-10 mm (.31 - .39 IN.)
102 J Conductor Area ... Not Exceeding 1.5 mm2 (.0023 Sq. IN.)
(4.02) C
F
D
SOL a SOL b
Position of cable
departure can be
changed. For details,
refer to DSHG-01
E
(5.33)
135.5
Dimensions mm (Inches)
Model Numbers
C D E F H J K
(S-)DSHG-06- -A -N/N1 39 (1.54) 53 (2.09) 200.5 (7.95) 27.5 (1.08) 196.4 (7.73) 47.2 (1.86) 45.2 (1.78)
(S-)DSHG-06- -D -N/N1 39 (1.54) 64 (2.52) 211.5 (8.33) 27.5 (1.08)
204.4 (8.05) 51.2 (2.02) 49.2 (1.94)
(S-)DSHG-06- -R -N 53 (2.09) 57.2 (2.25) 214.5 (8.44) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".
DHGM- 06 -50/5090
06X Sub-plate F
"C" Thd. "D" Thd. "E" Thd.
204 Model Numbers mm (in.)
(8.03)
DHGM-06-50 Rc 3/4
12 180 Rc 1/4 M12 24 (.94)
(.47) (7.09) DHGM-06X-50 Rc 1
25 130.2 DHGM-06-5090 3/4 NPT
(.98) (5.13) 1/4 NPT 1/2-13 UNC 26 (1.02)
DHGM-06X-5090 1 NPT
112.7
(4.44)
11(.43) Dia.
94.5 "D" Thd. (From Rear)
(3.72) 4 Places
77
(3.03)
"E" Thd. " F" Deep
53.2 6 Places
(2.09)
29.4(1.16)
5.6(.22)
TP Y
(3.81)
(4.57)
(3.63)
V 96.9
92.1
116
(2.94)
(2.88)
74.6
73.1
A
(1.81)
X B
46.1
19.1(.75)
17.5(.69)
(.47)
34(1.34)
12
DIMENSIONS IN
MILLIMETRES (INCHES)
DHGM- 06 -5080
06X
D
E
M12 Thd. 1/4 BSP.F Thd.
204 24(.94) Deep 4 Places F
(8.03) 6 Places
12 180 50 H
(.47) (7.09) (1.97)
25 130.2 35 J
(.98) (5.13) (1.38)
T Y P T
PY
(5.28)
(4.33)
(3.63)
(4.57)
92.1
110
V
116
W V
134
(2.94)
(2.88)
(.47)
11.9
74.6
73.1
W B A
(1.81)
X A B
46.1
X
(.35)
(.69)
(.75)
17.5
19.1
8.9
(.47)
12.5 N
12
11(.43) Dia.
(.49)
4 Places
156 L
(6.14) "C" Thd.
24.5(.96) Dia. 4 Places
4 Places K
SOL a SOL b
SOL a SOL b A
J
C
D
E
E
F
F
H
H
J
C
D
E
E
F
H
H
(S-)DSHG-06
10 - -C1/C2/C1C2 (S-)DSHG-06
10 - -C1/C2/C1C2- N
N1
Fully Extended Fully Extended
59 59
(2.32) (2.32)
J
C
D
E
E
F
F
H
H
Dimensions mm (Inches)
Model Numbers J
C D E F H
AC SO L DC SO L R SOL
DSHG-03- -C1 100 (3.94)
198.8 (7.83) 180.5 (7.11) 133.5 (5.26) 198.5 (7.81) 209.5 (8.25) 212.5 (8.37)
DSHG-03- -C2 100 (3.94)
DSHG-03- -C1C2 223.8 (8.81) 205.5 (8.09) 158.5 (6.24) 125 (4.92) 100 (3.94) 223.5 (8.80) 234.5 (9.23) 237.5 (9.35)
(S-) DSHG-04- -C1 106 (4.17)
204.8 (8.06) 186.5 (7.34) 139.5 (5.49) 204.5 (8.05) 215.5 (8.48) 218.5 (8.60)
(S-) DSHG-04- -C2 106 (4.17)
(S-) DSHG-04- -C1C2 229.8 (9.05) 211.5 (8.33) 164.5 (6.48) 131 (5.16) 106 (4.17) 229.5 (9.04) 240.5 (9.47) 243.5 (9.59)
(S-) DSHG-06- -C1 127 (5.00)
225.8 (8.89) 207.5 (8.17) 160.5 (6.32) 225.5 (8.88) 236.5 (9.31) 239.5 (9.43)
(S-) DSHG-06- -C2 127 (5.00)
(S-) DSHG-06- -C1C2 250.8 (9.87) 232.5 (9.15) 185.5 (7.30) 152 (5.98) 127 (5.00) 250.5 (9.86) 261.5 (10.30) 264.5 (10.41)
(S-) DSHG-10- -C1 190 (7.48)
288.8 (11.37) 270.5 (10.65) 223.5 (8.80) 288.5 (11.36) 299.5 (11.79) 302.5 (11.91)
(S-) DSHG-10- -C2 190 (7.48)
(S-) DSHG-10- -C1C2 313.8 (12.35) 295.5 (11.63) 248.5 (9.78) 215 (8.46) 190 (7.48) 313.5 (12.34) 324.5 (12.78) 327.5 (12.89)
Options
(1.38)
35
Stroke Adj. Screw (Port "A" End) 99 (3.90) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex. Fully Extended 13 (.51) Hex.
(1.30)
33
(S-)DSHG-06- -R
Solenoid Controlled
10 Fully Extended
C
SOL a SOL b
Stroke Adj. Screw (Port "A" End) Stroke Adj. Screw (Port "B" End)
17 (.67) Hex. D 17 (.67) Hex.
Fully Extended
Model Numbers C D E
(S-)DSHG-06- -R2 376 (14.80) 111 (4.37) 40 (1.57)
(S-)DSHG-10- -R2 558 (21.97) 164.5 (6.48) 65 (2.56)
DIMENSIONS IN
MILLIMETRES (INCHES)
D
D
(S-)DSHG-04- - -52/5290
15 14 16 17
Pipe Plug
Pipe Plug Removed for Internal
11 Removed for Internal Pilot Models
Drain Models
SOL a SOL b 11
X
Y 12
E
X Y Section Y-Y Section X-X
18 10 5 4 1 3 9 13 8 2 7
(S-)DSHG-06- - -53/5390
Solenoid Controlled
Pipe Plug Drain Models
Removed for Internal
Pilot Models 11
11
SOL a SOL b
21 21 12
X
X 12
Section X-X
Note: When ordering the o-rings, please specify the seal kit number listed in page
408. In addition to the above o-rings, o-rings for pilot valve is included in
the seal kit.
For the detail of the pilot valve o-rings, see page 359.