■Directional Valves

These valve are used for shifting oil flow direction of hydraulic circuit and for actuator starting/stopping as well as the
operating direction shifting of actuator.

● Solenoid Operated Directional Valves

● Solenoid Controlled Pilot Operated Directional Valves

●" " Series Shockless Type Directional Valves

● Pilot /Manually/Mechanically Operated Directional Valves

● Poppet Type Directional Valves

● Check /Pilot Controlled Check Valves

328 Directional Valves


DIRECTIONAL CONTROLS

Hydraulic Fluids
1. Type of Fluids
Any type of hydraulic fluid, listed in the table below can be used.

Type of Fluids Remarks


Petroleum Base Oils Use fluids equivalent to ISO VG32 or VG46.
Use phosphate ester or polyol ester type. When phosphate ester
1)
Synthetic Fluids type fluid is to be used, prefix “F-” to the model number
because a special seal (fluororubber) will be used.
Water Containing Fluids Use water-glycol fluids or W/O emulsion type fluids.

Notes 1: Not applicable with G-DSG and G-DSHG series valves.


2: For two types of manually operated directional valves, DMT- 06 and DMT- 10 , only petroleum base oils
06X 10X
and polyol ester type fluids are available.
3: Water-glycol fluids cannot be used for two types of solenoid operated poppet type two-way valves; CDST-
03✻ and CDSG-03 types.
4: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives is
advance. E
2. Recommended Viscosity and Oil Temperatures
Use hydraulic fluids which satisfy the both recommended viscosity and oil temperatures given in the table below.

Name Viscosity Oil Temperature

Directional Valves
DSG-005 series Solenoid Operated Directional Valves 20 – 200 mm2/s –15 – +60°C
(100 – 900 SSU) (5 – 140°F)
Solenoid Operated Directional Valves
Solenoid Controlled Pilot Operated Directional Valves
Poppet Type Solenoid Operated Directional Valves
Multi Purpose Control Valves
Solenoid Operated Poppet Type Two-Way Valves 15 – 400 mm2/s –15 – +70°C
Pilot Controlled Directional Valves (80 – 1800 SSU) (5 – 160°F)
Manually Operated Directional Valves
Mechanically Operated Directional Valves
Check Valves
Pilot Controlled Check Valves
G Series Shockless Type Solenoid Operated Directional Valves 15 – 200 mm2/s –15 – +60°C
(Shifting Time Adjustable) (80 – 900 SSU) (5 – 140°F)

3. Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorter the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
12. Use 25 µm or finer line filter (In case of DSG-005 series Solenoid Operated Directional Valves, NAS1638-Grade
11. Use 20 µm or finer line filter).

Directional Valves 329


■ Water-proof, dust-proof and vibration-resistance
There properties are in compliance with the following standards.
(The marking of indicates compliance)

Compliance
(S-/T-/L-)DSG-01
DSHG-01 G-DSG-01
DSLG
Item Standard Type Description DSHG-03 E-DSG-01 G-DSG-03
DSG-005 (S-)DSHG-04 (S-/E-/T-/L-) G-DSHG-04 DSLHG CDS❇
(S-)DSHG-06 DSG-03 G-DSHG-06 DSP❇
(S-)DSHG-10
JIS F8001 Class 1 water spray Drip-proof construction
Water-proof test
for marine Class 2 water spray Froth-roof construction
electric appliance
Damp-proof test M1 Test to examine damp-resistance of parts

JIS D0203 Damp-proof test M2 Test to examine functions of part under high
temperature and high humidity
Damp-proof and
Water-proof test
for automobile Splash-proof test R1 Test to examine functions of parts which are
likely to be exposed to water splash.
parts
Splash-proof test R2 Test to examine functions of parts which are
indirectly exposed to stormy weather or water splash.
★2 JIS C0920 Drip-proof type Not affected by water dropping at vertical angle of 15 degrees or less.
Water-proof Water-proof test
for electro- Rain-proof type Not affected by rain fall at vertical angle of 60 degrees or less.
mechanical parts Froth-proof type Not affected by water drip from any dirction.
an wiring
materials Jet-flow proof type Not affected by jet flow from any direction.
Protection Class 2: Not affected by water drip falling at vertical angle of
Drip-proof type (2) 15 degrees or less.
Protection Class 3: Not affected by rain falling at vertical angle of 60
(I.E.C) Rain-proof type degrees or less.
PUBL. 529 Protection Class 4: Not affected by water drip from any direction.
Froth-proof type
Protection Class 5: Not affected by jet flow from any direction.
Jet-flow proof type
(I.E.C)
Dust-proof Protection Class 6 Fully protected from entry of dust.
PUBL. 529
Vibration range: 7-59.5 Hz
Resonace test (IC) Duplex amplitude: 0.1 mm
Grade 1: duplex amplitude-0.5 mm
JIS C0911 Fixed frequency Grade 2: duplex amplitude-1.2 mm (2D✻)★1 (2D✻)★1 ★1
Frequence: 20 Hz
Vibration test for resistance test (IIC) Grade 3: duplex amplitude-1.8 mm (2D✻)★1 (2D✻)★1 ★1
small electric
appliances Grade 4: duplex amplitude-2.4 mm (2D✻)★1 (2D✻)★1 ★1
Vibration-
resistance Grade 1: duplex amplitude-0.3 mm (2D✻)★1 (2D✻)★1 ★1
Variable frequency
Frequency range: 7-59.5 Hz
Grade 2: duplex amplitude-0.5 mm (2D✻)★1 (2D✻)★1 ★1
resistance test (IIIC)
Grade 3: duplex amplitude-0.75 mm (2D✻)★1 (2D✻)★1 ★1
Grade A: Parts mounted on spring of body or chassis
JIS D1601 Class 1: having relatively low vibration. (2D✻)★1 (2D✻)★1
Vibration test for mainly for parts of
automobile parts passenger car Grade B: Parts mounted on spring of body or chassis
having relatively low vibration. (2D✻)★1 (2D✻)★1
Grade C: Parts mounted in engine having relatively low (2D✻)★1 (2D✻)★1
vibration
★1 : No-spring detented type (2D✻) and No-spring type (2N✻) can be used when energised continous for position holding.
★2 : For outdoor use, protect equipment with a cover, etc., to prevent direct exposure to water.

330 Directional Valves


Solenoid Operated Directional Valves
Solenoid Controlled Pilot Operated Directional Valves
“ ” Series Shockless Type Directional Valves
Pilot / Manually / Mechanically Operated Directional Valves

Maximum Flow
Max. U.S.GPM
Operating .3 .5 1 2 5 10 20 50 100 200 500 1000
Valve Type Graphic Symbols Pressure Page
1 2 5 10 20 50 100 200 500 1000 2000 5000
MPa (PSI) L /min
25 (3600) DSG-005 336
16 (2320) L-DSG-01
25 (3600) S-DSG-01 344
Solenoid Operated A B

Directional Valves a b 35 (5080) DSG-01


P T
16 (2320) L-DSG-03
25 (3600) S-DSG-03 361
31.5 (4580) DSG-03
Low Wattage (5W) Type A B
E-DSG-01
Dolenoid Operated a b
16 (2320) 378
Directional Valves P T E-DSG-03
25 (3600) T-S-DSG-01
Electronic Relay A B 379
a b
Incorporated 35 (5080) T-DSG-01
Solenoid Operated P T

Directional Valves 25 (3600) T-S-DSG-03 379


31.5 (4580) T-DSG-03
21 (3050) DSHG-01

Solenoid Controlled 25 (3600) DSHG-03


A B
Pilot Operated a b 381
DSHG-04/S-DSHG-04
Directional Valve Y P T
31.5 (4580) DSHG-06/S-DSHG-06
DSHG-10/S-DSHG-10
“ ” Series Shockless Type A B
a b G-DSG-01 412
Solenoid Operated 25 (3600)
Directional Valves P T G-DSG-03
“ ” Series Shockless Type A B
a b G-DSHG-04 418
Solenoid Controlled Pilot 25 (3600)
Y P T
Operated Directional Valves G-DSHG-06
A B
Pilot Operated 423
Directional Valves 31.5 (4580) DHG-04 06  10
X Y
P T

Manually Operated
A B 21 (3050) Threaded Connection (DMT)    03  06  10 429
Directional Valves 31.5 (4580) Sub-plate connection (DMG) 01
P T 03 04 06 10
A B

Mechanically Operated
7 (1020) Rotary (DR T
G) 02
P T
A
441
Directional Valves B

P T
25 (3600) Cam Operated (DC T
G)  01   03

Directional Valves 331


■ Spool Types
Spool types are classified to the condition of flow at the neutral position.

Spool Type Graphic Symbols Schematic Drawing Functions and Applications


(Centre Position)

A B
2 Holds pump pressure and cylinder position at neutral. Care
should be paid if used as a 2-position type because shock
( Closed Centre
All Ports ) P T
occurs when each port is blocked in transit.
T B P A

A B
3 Pump can be unloaded and actuator is floating at neutral.
( Open Centre
All Ports ) P T
If a 2-position type is used, shock is reduced as each ports is
released to tank in transit.
T B P A

A B Pump pressure is held and actuator is floated at neutral.


4 2-position type is used when system pressure is required to be
(Open Centre A, B&T) held in transit. Shock during transit is less compared to spool
P T T B P A type “2”.

40 A B
In a variation of spool type “4”, a restrictor is provided in A-T
( Open Centre A, B&T
Restricted Flow ) and B-T ports. Making it faster at stopping the actuator.
P T T B P A

A B
5 It can be used when a pump is unloading at neutral and actuator
(Open Centre P, A&T) is halted at one way flow.
P T T B P A

A B
6 Pump is unloading and actuator position held at neutral.
( Open Centre P&T
Closed Crossover ) P T
Suitable for series operation.
T B P A

A B
60 It is a variation of spool type “6”.
( Open Centre P&T
Open Crossover ) Shock is reduced as each port is released to tank on transit.
P T T B P A

A B
7
( Open Centre All Ports
Restricted Flow ) Mainly used as a 2-position type. Shock is reduced on transit.

P T T B P A

A B
Pump pressure and cylinder position is held at neutral in the
8
same way as spool type “2”.
(2-Way)
It is used as 2 way type.
P T T B P A

A B
9 Regenerative circuit is provided at neutral.
(Open Centre P, A&B)
P T T B P A

A B
10 Prevent actuator from one direction drift by leakage of P port at
(Open Centre B&T) neutral.
P T T B P A

A B
11 Halt actuator movement positively at B, T ports blocked P, A
(Open Centre P&A) ports connected at neutral.
P T T B P A

A B
12 Prevent actuator from one direction drift by leakage of P port at
(Open Centre A&T) neutral.
P T T B P A

332 Directional Valves


DIRECTIONAL CONTROLS

■ Mounting Surface
Mounting surface dimensions conform to ISO 4401, Hydraulic fluid power-Four-Port directional control valves-
Mounting surfaces.

Model Numbers ISO Code of Mounting Surface

()
S–
L–
E– DSG–01
T–
G– ISO 4401–AB–03–4–A
DSHG–01
DMG–01
DCG–01

()
S–
L–
E– DSG–03
T– ISO 4401–AC–05–4–A
G–
DMG–03
DCG–03

E
DSHG–03 ISO 4401–AC–05–4–A✻

( )
S– DSHG–04
G– ISO 4401–AD–07–4–A
DHG–04
DMG–04

( )
S– DSHG–06
G–
ISO 4401–AE–08–4–A
DHG–06
DMG–06
(S–) DSHG–10

Directional Valves
DHG–10 ISO 4401–AF–10–4–A
DMG–10
✻ The main port conform to the ISO 4401–AC–05–4–A.
The pilot and drain ports is sccordance with the ISO original draft.

Interchangeability in Installation between Current and New Design

Model change has been made on the following product.


The difference between current and new design has been described on the paragraph of “Interchangeability in
Installation between Current and New Design.” Refer to relevant pages on each series.

Model Numbers Interchangeability Related


Name Major Changes
Currrent New in Installation Page

DSG–005 Series Solenoid DSG–005– DSG–005– – –40/4090 ● High Flow


– –30/3090 DSG–005– – – N –40/4090 Yes — ● Low Pressure Drop
Operated Directional Valves N1 ● Din-connector type solenoid in addition
DSG–01 Series Solenoid
Operated Directional Valves ( )
S–
L– DSG–01–
T–
– –60/6090 ( )
S–
L– DSG–01–
T–
– –70/7090 Yes 357


High Pressure and High Flow
Low Pressure Drop
1/8,3/8 Solenoid Controlled DSHG–01– – –13/1390 DSHG–01– – –14/1490 ● Pilot valve has been changed
Pilot Operated Directional Yes — from DSG-01, 60 design to 70 design.
Valves DSHG–03– – –13/1390 DSHG–03– – –14/1490
1/2 Solenoid Controlled ● Pilot valve has been changed
Pilot Operated Directional (S–) DSHG–04– – –51/5190 (S–) DSHG–04– – –52/5290 Yes — from DSG-01, 60 design to 70 design.
Valves
3/4,1–1/4 Solenoid Controlled (S–) DSHG–06– – –52/5290 (S–) DSHG–06– – –53/5390 ● Pilot valve has been changed
Pilot Operated Directional (S–) DSHG–10– – –42/4290 (S–) DSHG–10– – –43/4390 Yes — from DSG-01, 60 design to 70 design.
Valves

Directional Valves 333


■ Solenoid Operated / Solenoid Controlled Operated Directional Valves
WIDE RANGE OF MODELS – Choose the optimum valve to
meet your needs from a largeselection available.

S H

1100
(291)
H : High Pres., High Flow, Low Pres. Drop Type
(S–)DSHG–10

S : Shockless Type

G : Shockless Type [Shifting Time Adjustable] S H


500
(132) P : Low Pressure Drop Type
(S–)DSHG–06
E : Low Wattage Type
S H
G
Maximum Flow L / min (U.S.GPM)

300
(79.3)
(S–)DSHG–04
250
(66.1) G–DSHG–06
G
S
160
(42.3)
P
DSHG–03 G–DSHG–04

S H
120
(31.7)
S–DSG–03 DSG–03 H
100
(26.4) G DSG–01
80
(21.1)
G–DSG–03
E S
63
(16.6)
E–DSG–03 S–DSG–01
L-DSG-03 [60 L/min (15.9 U.S.GPM)]
S G
E
40
(10.6) E–DSG–01 DSHG–01 G–DSG–01
E
30
(7.9)
E–DSG–01

15
(4.0) DSG–005
0 16 21 25 31.5 35
(2320) (3050) (3630) (4570) (5080)

Pressure MPa (PSI)

334 Solenoid Operated / Solenoid Controlled Operated Directional Valves


DIRECTIONAL CONTROLS

Instructions
● Mounting
DSG-005 No mounting restrictions for any model.

-DSG-01 No-spring detented models not energised continuously must be installed so that
-DSG-03 the spool axis L-L’ is horizontal. Otherwise there is no mounting restrictions. L L’

-DSG-01/03

DSHG-01
DSHG-03
(S-) DSHG-04 No-spring models not energised continuously must be installed so that the spool
(S-) DSHG-06 axis L-L’ is horizontal. Otherwise there is no mounting restrictions. ,
(S-) DSHG-10 L L

-DSHG

● Energisation
1. No-Spring Type
E
One of two solenoids should be energised continuously to avoid malfunction.
2. On double solenoid valves do not energise both at the same time as it will result in coils burning out.
● Valve Tank Port
Avoid connecting the valve tank port to a line with possible surge pressure.
Piping end of tank line should be submerged in oil.

Solenoid Operated / Solenoid Operated Controlled


● Pilot Drain Port for Solenoid Controlled Pilot Operated Valve
Avoid connecting the valve pilot drain port to a line with possible surge pressure.
Piping end of drain should be submerged in oil.
● Shockless Type
In order to benefit from a shockless operation, it is necessary to fill the lbf. N
30 150
tank line with operating oil. 05
G-0

Directional Valves
100 r DS
Operating

Only after the tank line has been filled with operating oil should the 20 pt fo
exce
Force

valve be used on a regular basis. 10 50 05


DSG-0
0
● Operating Force be Manual Actuator 0 1 2 3 4 MPa
Take care as the operating force by the manual actuator increases in 0 100 200 300 400 500 PSI
proportion to the tank line back pressure. (See the graph right.) Tank Line Back Pressure

Solenoid
■ Solenoid connector (DIN connector) ■ R type Models with Current Rectifier and DC
The solenoid connector is in accordance with the Solenoid
international standard ISO 4400 (Fluid power systems Specially designed DC solenoid and receptacle (or
and components-Three-pin electrical plug connectors- connector) containing AC-DC rectifier and transient
Characteristics and requirements). peak suppressor are provided. Connection to be made
■ AC Solenoid to AC power source as with conventional AC solenoid.
Remarkably high reliability and long life and other
50-60 Hz common service solenoids do not require re-
advantages including quiet valve operation. No over-
wiring when the applied frequency is changed. heating of coil due to the spool sticking and protection
■ DC Solenoid ( -series Solenoid Operated against transient voltage peaks are assured.
Directional Valve) ■ RQ type Models with Current rectifier and Quick
These valves differ from conventional DC solenoid Return Solenoid
operated directional valves and have the following Valve characteristics are identical to R type except for
characteristics: the fast return time of the spool after deenergisation.
1. The spark between the relay contacts has been
■ Insulation Class of Solenoid
eliminated and therefore the valve can be operated by
miniature relays. Model numbers Insulation Class
2. The surge voltage is approximately 10 % of that
DSG-005, DSG-01, S-DSG01
normally experienced. L-DSG-01, E-DSG-01, T-DSG-01
3. Time lag on de-energisation is reduced by DSG-03, S-DSG-03, L-DSG-03 Class H
approximately 50 %. E-DSG-03, T-DSG-03
DSHG-01/03/04/06/10, S-DSHG-04/-06/10
G-DSG-01, G-DSG-03 Class F

Solenoid Operated / Solenoid Controlled Operated Directional Valves 335


DIRECTIONAL CONTROLS

■ Solenoid Controlled Pilot Operated Directional Valves


These valves are composed of a solenoid operated pilot valve and a pilot
operated slave valve. When a solenoid is energised the pilot valve
directs the flow to move the spool of the slave valve, thus changing the
direction of flow in the hydraulic circuit.

● High Pressure High Flow


High pressure [31.5 MPa (4570 PSI)] along which high flow means
compact system design.

● Lower Pressure Drop


System energy saving increased as pressure drop of each valve has been
greatly reduced.

Specifications

Pilot Operated Directional Valves


★1 Max. Min. ★2 Max. T-Line Back Max. Change-
Valve Max. Flow Operating Max. Pilot Required Pressure over Frequecy Mass
Model Numbers L/min Pressure MPa (PSI) Cycles/Min {min–1} kg
Type Pressure Pilot Pres.
(U.S.GPM)
MPa (PSI) MPa (PSI) MPa (PSI) Ext. Drain Int. Drain AC DC R (1bs.)

Solenoid Controlled
DSHG-01-3C - -14/1480/1490 3.2 (7.1)
40 (10.6) 21 (3050) 21 (3050) 1.0 (145) 16 (2320) 16 (2320) 120 120 120
DSHG-01-2B - -14/1480/1490 2.7 (6.0)
DSHG-03-3C - -14/1490 6.9 (15.2)
DSHG-03-2N - -14/1490 160 (42.3) 25 (3630) 25 (3630) 0.7 (100) 16 (2320) 16 (2320) 120 120 120 6.9 (15.2)
Standard DSHG-03-2B - -14/1490 6.4 (14.1)
Type (S-)DSHG-04-3C - -52/5290 8.5 (18.7)
(S-)DSHG-04-2N - -52/5290 300 (79.3) 31.5 (4570) 25 (3630) 0.8 (120) 21 (3050) 16 (2320) 120 120 120 8.5 (18.7)
(S-)DSHG-04-2B - -52/5290 8.0 (17.6)
(S-)DSHG-06-3C - -53/5390 ★3
12.4 (27.3)
(S-)DSHG-06-2N - -53/5390 25 (3630) 0.8 (120) 120 120 120 12.4 (27.3)
500 (132) 31.5 (4570) 21 (3050) 16 (2320)
(S-)DSHG-06-2B - -53/5390 11.9 (26.2)
Shockless (S-)DSHG-06-3H - -53/5390 21 (3050) 1.0 (145) 110 110 110 13.2 (29.1)
Type (S-)DSHG-10-3C - -43/4390 120 120 100 45.0 (99.2)
25 (3630)
(S-)DSHG-10-2N - -43/4390 ★3 100 100 100 45.0 (99.2)
1100 (291) 31.5 (4570) 1.0 (145) 21 (3050) 16 (2320)
(S-)DSHG-10-2B - -43/4390 44.5 (98.1)
21 (3050) 60 60 50
(S-)DSHG-10-3H - -43/4390 52.9 (116.6)

★1. Maximum flow indicates a ceiling flow. As the ceiling flow depends on the type of
spool and operating condition, refer to the List of Spool Functions on pages 386 to 390 Yuken can offer flanged connection valves described below.
for details. Consult us for the details.
★2. Pilot pressure of internal pilot drain models must always exceed tank line back pressure Rated Flow Max. Pressure
by a minimum required pilot pressure. Model Numbers
l/min (U.S.GPM) MPa (PSI)
★3. Min. pilot pressure of with pilot piston in 1.8 MPa (260 PSI).
DSHF-10- - -27 315 (83) 21 (3050)
DSHF-16- - -37 500 (132) 21 (3050)
■ Solenoid Ratings DSHF-24- - -28 1200 (317) 21 (3050)
Solenoid ratings of pilot valve are identical with those of standard solenoid DSHF-32- - -27 2400 (634) 21 (3050)
valve. Refer to relevant solenoid ratings described on the page below.
Model Pilot Valve Model Solenoid Ratings described
Numbers Numbers on the page below CSA Approved Solenoid Valve
DSHG-01
Available to supply DSHG-06 series valve approved
DSHG-03 by the CSA (Canadian Standards Association).
(S-)DSHG-04 DSG-01- - -70 345 Consult us for details.
(S-)DSHG-06
(S-)DSHG-10

Solenoid Controlled Pilot Operated Directional Valves 381


■ Model Number Designation
F- S- DSHG -06 -2 B 2 A -C2 -E T
Special Series No. of Special Two Models with Pilot Drain
Type Valve Spool-Spring Spool
Seals Number Valve Position Pilot Choke Connec- Connec-
Size Arrangement Type
Position Valve Valve tion tion

2, 3, 4
C: 40, 5, 60
3
Spring Centred 7, 9, 10
01 11, 12
B: 2, 3, 4
2
Spring Offset 40, 7

None: 2, 3, 4
Standard 3 C: 40, 5, 60
Type Spring Centred 7, 9, 10
11, 12
03
N: 2
F: No-Spring 3
For DSHG: 2 4
Phos- Solenoid B: 40
Controlled Spring Offset 7 None: None:
phate C1 : Internal External
Ester Pilot
Operated 2, 4, 40 With C1 Pilot Drain
Type Choke
Directional 3 C: 60, 10, 12
Fluids ★1
Spring Centred 3, 5, 6
Valve, ( )
(Omit
required )
if not
Sub-plate
Mounting 04
7, 9, 11 C2 :
With C2
E:
External
E:
Internal
N: 2, 4, 40 A ★2 Drain
(3, 7) ★1 Choke Pilot
No-Spring (Omit if not required)
2
★2
B: 2, 4, 40 A B★2
None: Spring Offset (3, 7) ★1 (Omit if not required)
C1C2 :
Standard With C1 &
Type H: 2, 4, 40 C2 Choke
Pressure Centred 60, 10, 12
06 3 3, 5, 6 ★1
S: C: (7, 9, 11 )
Shock-
less
Spring Centred (Omit
required )
if not

Type N: 2, 4, 40 A ★2
No-Spring (3, 7) ★1 (Omit if not required)

10 2
B: 2, 4, 40 A
★2
B★2
Spring Offset (3, 7) ★1 (Omit if not required)

Note: In spool type “3”, “5”, “6”, “60”, and “7”, the combination applicable between pilot system and drain system is as described in the table below.

Pilot Connection Drain Connection Care in Application


Hold back pressure in the tank line so that the difference between
External Drain pilot pressure and drain pressure is always more than minimum
Internal Pilot required pilot pressure.
Internal Drain (T) Combination is not applicable
External Drain
External Pilot (E) No restrictions in the combination on us
Internal Drain (T)

382 Solenoid Controlled Pilot Operated Directional Valves


DIRECTIONAL CONTROLS

-R2 -A100 -C -H -N -53 - -L


★3
Spool Control Manual Bult-in Type of Elec- Design Models with
Coil Design
Modification Override of Orifice for trical Conduit Standard Reverse Mtg.
Type Number
(Omit if not required) Pilot Valve Pilot Line Connection of Solenoid

AC: 14 None:
A100 , A200 Japanese
A120 , A240 Standard L
"JIS" (Omit if not required)
DC:
D12 , D24
D48
R2 : None:
AC → DC Terminal
With Stroke 90:
R100 , R200 Box Type

E
Adjustment, None : 14 N.
Both Ends Manual American
Override Design
RA : Pin Standard
With Stroke L
(Omit if not required)
Adjustment,
Port "A" End
RB : None:
With Stroke Japanese

Pilot Operated Directional Valves


Adjustment, Standard
Port "B" End "JIS" &
52
AC: C: European
A100 , A200 Push Design

Solenoid Controlled
A120 , A240 Button & N: Standard L
Lock Nut Push-in (Omit if not required)
DC: Connector
D12 , D24 Type 80:
R2 : With Stroke Adj., D48 European
Both Ends 53 Design
RA : With Stroke Adj., AC → DC H: Standard
Port "A" End R100 , R200 Refer to ★5
N1 : (Applicable
RB : With Stroke Adj., Push-in
★4 only for
Port "B" End Connector DSHG-01)
P2 : With Pilot Piston, with
Both Ends 90:
Indicator
N.
PA : With Pilot Piston, Light 43 American L
Port "A" End
Design (Omit if not required)
PB : With Pilot Piston, Standard
Port "B" End

★1. Shekless type (S-DSHG) are not available for spool type marked ( ).
★2. As for the details of the valve using the neutral position and the side position (either SOL a or SOL b side), please refer to page 391.
Furthermore, the spool types other than “2”, “4”, “40” (3, 7) are also available.
★3. In spool-spring arrangement “H” (Pressure centred models), the valves with stroke adjustment (R*) and pilot-piston (P*) are not available.
★4. NI stands for Plug-in connector with solenoid indicator light. NI is not available for R-type solenoids.
★5. In spool-spring arrangement “H” (pressure centred models), in case the pilot pressure is more than 10 MPa (1450 PSI), please specify that the
valve should have the built-in orifice to the pilot line.

In the table above, the symbols and numbers highlighted with shade represent the optional extras.
The valves with model number having such optional extras are handles as options, therefore
please confirm the time of delivery with us before ordering.

Solenoid Controlled Pilot Operated Directional Valves 383


Sub-plates
Japanese Standard "JIS" European Design Standard N. American Design Standard
Valve
Approx. Approx. Approx.
Model Sub-plate Thread Sub-plate Thread Sub-plate Thread
Mass Mass Mass
Numbers Model Numbers Size Model Numbers Size Model Numbers Size
kg (1bs.) kg (1bs.) kg (1bs.)
DSGM-01-31 Rc 1/8 0.8 (1.8) DSGM-01-3080 1/8 BSP.F 0.8 (1.8) DSGM-01-3090 1/8 NPT 0.8 (1.8)
DSHG-01 DSGM-01X-31 Rc 1/4 0.8 (1.8) DSGM-01X-3080 1/4 BSP.F 0.8 (1.8) DSGM-01X-3090 1/4 NPT 0.8 (1.8)
DSGM-01Y-31 Rc 3/8 0.8 (1.8) DSGM-01Y-3090 3/8 NPT 0.8 (1.8)
DSGM-03-40 Rc 3/8 3.0 (6.6) DSGM-03-2180 3/8 BSP.F 3.0 (6.6) DSGM-03-2190 3/8 NPT 3.0 (6.6)
DSGM-03X-40 Rc 1/2 3.0 (6.6) DSGM-03X-2180 1/2 BSP.F 3.0 (6.6) DSGM-03X-2190 1/2 NPT 3.0 (6.6)
DSHG-03
DSGM-03Y-40 Rc 3/4 4.7 (10.4) DSGM-03Y-2180 3/4 BSP.F 4.7 (10.4) DSGM-03Y-2190 3/4 NPT 4.7 (10.4)
DHGM-03Y-10 Rc 3/4 4.7 (10.4) DHGM-03Y-1080 3/4 BSP.F 4.7 (10.4) DHGM-03Y-1090 3/4 NPT 4.7 (10.4)
DHGM-04-20 Rc 1/2 4.4 (9.7) DHGM-04-2080 1/2 BSP.F 4.4 (9.7) DHGM-04-2090 1/2 NPT 4.4 (9.7)
DSHG-04
DHGM-04X-20 Rc 3/4 4.1 (9.0) DHGM-04X-2080 3/4 BSP.F 4.1 (9.0) DHGM-04X-2090 3/4 NPT 4.1 (9.0)
DHGM-06-50 Rc 3/4 7.4 (16.3) DHGM-06-5080 3/4 BSP.F 8.5 (18.7) DHGM-06-5090 3/4 NPT 7.4 (16.3)
DSHG-06
DHGM-06X-50 Rc 1 7.4 (16.3) DHGM-06X-5080 1 BSP.F 8.5 (18.7) DHGM-06X-5090 1 NPT 7.4 (16.3)
DHGM-10-40 Rc 1-1/4 21.5 (47.4) DHGM-10-4080 1-1/4 BSP.F 21.5 (47.4) DHGM-10-4090 1-1/4 NPT 21.5 (47.4)
DSHG-10
DHGM-10X-40 Rc 1-1/2 21.5 (47.4) DHGM-10X-4080 1-1/2 BSP.F 21.5 (47.4) DHGM-10X-4090 1-1/2 NPT 21.5 (47.4)
DSGM-03 is available only for Internal pilot-Internal drain type (Use DHGM-03Y for other valves).
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.

Mounting Bolt
Mouting Bolt
Model
Japanese Standard "JIS" Tightening Torque
Numbers Name N. American Design Standard Qty.
European Design Standard Nm (in. 1bs.)
1
3 MBK-01-01-30 MBK-01-01-3090 1
DSHG-01 Mtg. Bolt Kit 2 1 set 5-6 (43 - 52)
MBK-01-02-30 MBK-01-02-3090 2
DSHG-03 Soc. Hd. Cap Screw M6 35 Lg. 1/4-20 UNC 1-3/4 Lg. 4 12 - 15 (104 - 130)
M6 45 Lg. 1/4-20 UNC 1-3/4 Lg. 2 12 - 15 (104 - 130)
(S-)DSHG-04 Soc. Hd. Cap Screw
M10 50 Lg. 3/8-16 UNC 2 Lg. 4 58 - 72 (504 - 625)
(S)-DSHG-06 Soc. Hd. Cap Screw M12 60 Lg. 1/2-13 UNC 2-1/2 Lg. 6 100 - 123 (868 - 1068)
(S)-DSHG-10 Soc. Hd. Cap Screw M20 75 Lg. 3/4-10 UNC 3 Lg. 6 473 - 585 (4106 - 5078)

1. For Internal Pilot-Internal Drain.


2. For External Pilot or External Drain.
3. Mounting bolt kit is common to that of 01 series modular valves.
Refer to figure below for the dimensions of bolt kit.

Stud Bolt
"B " Thd.
Both Ends

9 9
(.35) (.35)
A
DIMENSIONS IN
MILLIMETRES (INCHES)
Nut "B " Thd.

Model Numbers A mm (In.) "B " Thd.


8.5 Dia.

MBK-01-01-30 94 (3.70 )
(.33)

M5
MBK-01-02-30 134 (5.28 )
MBK-01-01-3090 94 (3.70 )
No.10-24 UNC
4 MBK-01-02-3090 134 (5.28 )
9
(.16)
(.35)
15
(.59)

384 Solenoid Controlled Pilot Operated Directional Valves


DIRECTIONAL CONTROLS

Options
Models with Pilot Choke Adjustment Pressure Centred Models (3H )
When the adjustment screw is turned clockwise, The pressure centered type can be used when the
changeover speed of the main spool becomes slow. In returning of the main spool to the neutral position is
case of the spring centred valves in particular, making required to be firmily.
slow of the returning speed of the main spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with the
valves of spring centred, no-spring, offset, pressure Graphic Symbols (Ex.: External Pilot-External Drain)
centred and the valves with stroke adjustment.
(Only for 3H6, 3H60)
Graphic Symbols (Ex.: Spring Centred) A B A B
a a
DSHG-01,06,10 P T
b b
C2 Choke Y V
X Y P T V X

C1 Choke
E
b a
Models with Stroke Adjustment (R2, RA, RB)
Y When the adjustment screw is screwed in , the main
P
T
spool stroke becomes short and flow rate reduces.
Graphic Symbols (Ex.: Spring Centred)
A B
"R2" Models
DSHG-03, 04
C2 Choke A B

Pilot Operated Directional Valves


a b
Y P T

a b
C1 Choke "RA" Models

Solenoid Controlled
Y
P A B
T a b
Y P T

A B
"RB" Models
A B
a b
Y P T
Models with Pilot Piston(P2, PA, PB)
The valves with a pilot piston can be used when the high
speed changeover of the main spool is required. Additional Mass of Options
However, please not that in case of spring centered
valves, there is no change in the returning speed of the Add the mass described below to the mass of standard
main spool to the neutral position even with the pilot models on page 381, if options are required.
piston.
kg (1bs.)
Graphic Symbols (Ex.: Spring Centred) Model with Pilot Models with Models with
Model Choke Adj. Pilot Piston Stroke Adj.
"P2" Models Numbers PA PA
C1, C2 C1C2 P2 P2
A B PB PB
a b
DSHG-03 0.65(1.4) 1.3(2.9) 0.6(1.3) 0.3 (.7)
W V
Y P T (S-)DSHG-04 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5 (1.1)
(S-)DSHG-06 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1) 1.2(2.6) 06 (1.3)
"PA" Models (S-)DSHG-10 0.65(1.4) 1.3(2.9) 3.6(7.9) 1.8(4.0) 3.7(8.2) 1.85 (4.1)
A B
a b

V
Y P T
Options on Pilot Valve
"PB" Models
The same options to DSG-01 series valves are available.
A B
Please refer to page 345 for the details.
a b

W
Y P T

Solenoid Controlled Pilot Operated Directional Valves 385


DIRECTIONAL CONTROLS

Reverse Mounting of Solenoid.


In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b
position (side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in
the reverse position - SOL a side - is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.

A B A B SOL a
SOL b
APB
b APB a

P T X A B P T Y
X A B
Y

Standard Mtg. of Solenoid Reverse Mtg. of Solenoid ("L")

Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B).
(Example) In case of Spool Type "2"
E
Neutral Position
SOL. a Energised SOL. b Energised
Position Position
A B

a b

Y P T

Pilot Operated Directional Valves


2B2A 2B2B
A B A B
b b

Solenoid Controlled
Y P T Y P T

"A": Use of Neutral and "B": Use of Neutral and


SOL. a Energised SOL. b Energised
Position Position

Graphic
Graphic Symbols Graphic Symbols
Symbols
Model Numbers Model Numbers Model Numbers
Standard Reverse Standard Reverse Standard
Mtg. Mtg. Type Mtg. Mtg. Type Mtg.
04 A B A B 04 A B A B 04 A B
b a b a a b
DSHG-06 -2B A DSHG-06 -2B B DSHG-06 -2N A
Y P T P T Y Y P T P T Y
10 10 10 Y P T

(S-)DSHG- -2B2A (S-)DSHG- -2B2B (S-)DSHG- -2N2A

DSHG- -2B3A DSHG- -2B3B DSHG- -2N3A

(S-)DSHG- -2B4A (S-)DSHG- -2B4B (S-)DSHG- -2N4A

(S-)DSHG- -2B40A (S-)DSHG- -2B40B (S-)DSHG- -2N40A

DSHG- -2B5A DSHG- -2B5B DSHG- -2N5A

DSHG- -2B6A DSHG- -2B6B DSHG- -2N6A

(S-)DSHG- -2B60A (S-)DSHG- -2B60B (S-)DSHG- -2N60A

DSHG- -2B7A DSHG- -2B7B DSHG- -2N7A

DSHG- -2B9A DSHG- -2B9B DSHG- -2N9A

(S-)DSHG- -2B10A (S-)DSHG- -2B10B (S-)DSHG- -2N10A

DSHG- -2B11A DSHG- -2B11B DSHG- -2N11A

(S-)DSHG- -2B12A (S-)DSHG- -2B12B (S-)DSHG- -2N12A

Solenoid Controlled Pilot Operated Directional Valves 391


DIRECTIONAL CONTROLS

List of Spool Functions and Maxmum Flow (DSHG-06/S-DSHG-06)


Three Positions
Spring Centred Pressure Centred
Graphic Symbol Graphic Symbol
A B
Maximum Flow A B
Maximum Flow
Spool Type a b
L /min (U.S.GPM)
a b
L /min (U.S.GPM)
Y P T Y P T V

10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
410 (108) 310 (81.9) 420 (111)
"2" (S-)DSHG-06-3C2 500 (132) 500 (132) (S-)DSHG-06-3H2 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)

"3" DSHG-06-3C3 500 (132) 500 (132) 460 (122) 370 (97.8) DSHG-06-3H3 500 (132) 500 (132) 500 (132) 500 (132)

410 (108) 310 (81.9) 420 (111)


"4" (S-)DSHG-06-3C4 500 (132) 500 (132) (S-)DSHG-06-3H4 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
410 (108) 310 (81.9) 420 (111)
"40" (S-)DSHG-06-3C40 500 (132) 500 (132) (S-)DSHG-06-3H40 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)

"5" DSHG-06-3C5 500 (132) 500 (132) 425 (112) 350 (92.5) DSHG-06-3H5 500 (132) 500 (132) 500 (132)
470 (124)
500 (132)
420 (111)
E
"6" DSHG-06-3C6 475 (125) 390 (103) 300 (79.3) 230 (60.8) DSHG-06-3H6 500 (132) 500 (132) 500 (132)
500 (132)
420 (111)
"60" (S-)DSHG-06-3C60 475 (125) 420 (111) 340 (89.8) 280 (74.0) (S-)DSHG-06-3H60 500 (132) 500 (132) 500 (132)
500 (132)

"7" DSHG-06-3C7 500 (132) 500 (132) 450 (119) 360 (95.1) DSHG-06-3H7 500 (132) 500 (132) 500 (132) 500 (132)

Pilot Operated Directional Valves


450 (119) 360 (95.1)
"9" DSHG-06-3C9 500 (132) 500 (132) DSHG-06-3H9 500 (132) 500 (132) 500 (132) 500 (132)
500 (132) 500 (132)
410 (108) 310 (81.9) 460 (122)

Solenoid Controlled
"10" (S-)DSHG-06-3C10 500 (132) 500 (132) (S-)DSHG-06-3H10 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
410 (108) 310 (81.9) 460 (122)
"11" DSHG-06-3C11 500 (132) 500 (132) DSHG-06-3H11 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
410 (108) 310 (81.9) 460 (122)
"12" (S-)DSHG-06-3C12 500 (132) 500 (132) (S-)DSHG-06-3H12 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)

Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
Spool Type a b b
L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T

10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)

"2" (S-)DSHG-06-2N2 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B2 500 (132) 500 (132) 500 (132) 500 (132)

"3" DSHG-06-2N3 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B3 500 (132) 500 (132) 500 (132) 500 (132)

"4" (S-)DSHG-06-2N4 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B4 500 (132) 500 (132) 500 (132) 500 (132)

"40" (S-)DSHG-06-2N40 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B40 500 (132) 500 (132) 500 (132) 500 (132)

"7" DSHG-06-2N7 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B7 500 (132) 500 (132) 500 (132) 500 (132)

Notes:1. The relation between max. flow and pilot pressure in the table above is as shown
below.
(Example) Pilot Pressure at 0.8 MPa (120 PSI).
410 (108) In case pressure centred models, pilot pressure
Maximum flow rate is constant regardless of pilot pressure. 500 (132) is more than 1 MPa (150 PSI)
Pilot Pressure more than 0.8 MPa (120 PSI). 500 (132)
In case pressure centred models, pilot pressure is more than Pilot Pressure at 1.5 MPa (220 PSI).
1 MPa (150 PSI).

2. Max. flow in the table above represents the value in the flow condition of P A
B T (or P B A T) as shown in the circuit diagram right. A B
In case the valve is used in the condition that either A or B port is blocked, the a b
maximum flow differs according to a hydraulic circuit, therefore, please consult us
P T
for details.

Solenoid Controlled Pilot Operated Directional Valves 389


DIRECTIONAL CONTROLS

DSHG-06, S-DSHG-06
DSHG-06
1
PSI MPa 2 Pressure Drop Pressure Drop
300 2.0 Spool Spool
3 Curve Numbers Curve Numbers
Type Type
P

250 4 P AB TP BA TP T P AB TP BA TP T
1.6
Pressure Drop

200 5 2 8 5 8 7 60 6 5 6 7 1
1.2 3 6 4 6 7 4 7 6 4 6 7
150 6
0.8 7 4 8 5 8 7 9 6 5 6 7
100
40 8 5 8 7 10 8 5 8 7
50 0.4 8
5 8 4 5 7 1 11 8 4 5 7
0
0 6 5 3 5 4 1 12 8 5 8 7
0 100 200 300 400 500 L /min

0 20 40 60 80 100 120 140 U.S.GPM


Flow Rate
S-DSHG-06
Pressure Drop Pressure Drop
Spool Spool
Curve Numbers Curve Numbers

E
Type Type
P AB TP BA TP T P AB TP BA TP T
2 6 1 6 2 60 6 2 6 3 1
4 6 2 6 2 10 8 5 8 7
40 8 5 8 7 12 8 5 8 7

DSHG-10, S-DSHG-10

Pilot Operated Directional Valves


DSHG-10
1 2
PSI MPa Pressure Drop Pressure Drop
300 2.0 3 Spool Spool
Curve Numbers Curve Numbers
Type Type

Solenoid Controlled
4
P

250
1.6
P AB TP BA TP T P AB TP BA TP T
5 2 9 6 9 8 60 8 5 8 5 3
Pressure Drop

200
1.2 6 3 7 6 7 7 5 7 7 6 7 7
150
7 4 9 6 9 6 9 7 6 7 8
0.8
100 8 40 9 6 9 8 10 9 5 9 8
50 0.4 9 5 9 6 8 6 1 11 9 6 8 7
0
0 6 5 3 5 2 2 12 9 7 9 6
0 200 400 600 800 10001100 L /min

0 50 100 150 200 250 300 U.S.GPM


Flow Rate
S-DSHG-10
Pressure Drop Pressure Drop
Spool Spool
Curve Numbers Curve Numbers
Type Type
P AB TP BA TP T P AB TP BA TP T
2 8 3 8 4 60 8 4 8 4 2
4 8 5 8 6 10 9 5 9 8
40 9 6 9 8 12 9 7 9 6

For any other viscosity, multiply the factors in the table below.
mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity
SSU 77 98 141 186 232 278 324 371 417 464
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula right.
P' = P(G'/0.850)

Solenoid Controlled Pilot Operated Directional Valves 393


Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.

Test Conditions
Coil Type : D (Models with DC solenoids)
Voltage : Rated Voltage
Oil Viscosity : 35 mm 2/s (164 SSU)

DSHG-04 DSHG-10
ms ms
250
150
3C
SOL"ON"
Changeover Time

SOL"OFF" 200
100
2B
SOL"ON" 3C

Changeover Time
2N SOL"OFF"
SOL"OFF" 150
50 SOL"ON"
2B
2N SOL"ON","OFF"
0 100
0 5 10 15 20 25 MPa

50
0 1000 2000 3000 3600 PSI

Pilot Pressure 0
0 5 10 15 20 25 MPa

DSHG-06
0 1000 2000 3000 3600 PSI
ms
150
Pilot Pressure
3C
SOL"ON"
Changeover Time

SOL"OFF"
100
2B
2N SOL"ON"
SOL"OFF"
50

0
0 5 10 15 20 25 MPa

0 1000 2000 3000 3600 PSI

Pilot Pressure

394 Solenoid Controlled Pilot Operated Directional Valves


DIRECTIONAL CONTROLS

Mounting surface:
Terminal Box Type: (S-)DSHG-06- - -53/5390 ISO 4401-AE-08-4-A
Solenoid Indicator Light Pressure Port "P"
Tank Port "T"
255(10.04) Pilot Drain Port "Y"
(For External Drain Models Only)
13.5(.53) Dia. Through 50.5 130.2
20(.79) Dia. Spotface (1.99) (5.13)
53.2 Model Numbers "C" Thd.
6 Places
(2.09)
T P Y (S-)DSHG-06- - -53 G 1/2
(S-)DSHG-06- - -5390 1/2 NPT

(3.63)

(4.65)
L L′

92.1

118
(1.81)
46.1
X A B
Pilot Pressure Port "X"
(For External Pilot Models Only) 77

(.51)
13
(3.03) 156
Cylinder Port "A" (6.14) Cylinder Port "B"

AC :196.4(7.73)
DC,R:204.4(8.05)
95
AC :45.5(1.79) Space Needed to Remove
DC,R:50(1.97) Solenoid-Each End
AC :50.7(2.00) 46
E
(3.74) DC,R:54.7(2.15) (1.81) Electrical Conduit Connection
Double Solenoid "C" Thd. (Both Ends)
Models Only
Manual Actuator
SOL a SOL b 6(.24) Dia.
200.8(7.91)

APB
182.5(7.19)
135.5(5.33)

Nut

Pilot Operated Directional Valves


27(1.06) Hex.

L L′
(1.61)

Solenoid Controlled
41

AC :45.2(4.78) 6(.24) Dia. Two Locating Pins


(.24)

Mounting Surface DC,R:49.2(1.94)


6

(O-Rings Furnished)

DIMENSIONS IN
MILLIMETRES (INCHES)
Plug-in Connector Type: (S-)DSHG-06- - - N -53/5390
N1

Cable Departure
H Cable Applicable:
Outside Dia. ...... 8-10 mm (.31 - .39 IN.)
102 J Conductor Area ... Not Exceeding 1.5 mm2 (.0023 Sq. IN.)
(4.02) C
F
D

SOL a SOL b
Position of cable
departure can be
changed. For details,
refer to DSHG-01
E
(5.33)
135.5

valve on page 396.

Dimensions mm (Inches)
Model Numbers
C D E F H J K
(S-)DSHG-06- -A -N/N1 39 (1.54) 53 (2.09) 200.5 (7.95) 27.5 (1.08) 196.4 (7.73) 47.2 (1.86) 45.2 (1.78)
(S-)DSHG-06- -D -N/N1 39 (1.54) 64 (2.52) 211.5 (8.33) 27.5 (1.08)
204.4 (8.05) 51.2 (2.02) 49.2 (1.94)
(S-)DSHG-06- -R -N 53 (2.09) 57.2 (2.25) 214.5 (8.44) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".

Solenoid Controlled Pilot Operated Directional Valves 399


Sub-plate

DHGM- 06 -50/5090
06X Sub-plate F
"C" Thd. "D" Thd. "E" Thd.
204 Model Numbers mm (in.)
(8.03)
DHGM-06-50 Rc 3/4
12 180 Rc 1/4 M12 24 (.94)
(.47) (7.09) DHGM-06X-50 Rc 1
25 130.2 DHGM-06-5090 3/4 NPT
(.98) (5.13) 1/4 NPT 1/2-13 UNC 26 (1.02)
DHGM-06X-5090 1 NPT
112.7
(4.44)
11(.43) Dia.
94.5 "D" Thd. (From Rear)
(3.72) 4 Places
77
(3.03)
"E" Thd. " F" Deep
53.2 6 Places
(2.09)
29.4(1.16)

5.6(.22)

TP Y
(3.81)
(4.57)

(3.63)

V 96.9
92.1
116

(2.94)

(2.88)
74.6

73.1

A
(1.81)

X B
46.1
19.1(.75)

17.5(.69)
(.47)

34(1.34)
12

17.5 11(.43) Dia. Through


(.69) 17.5(.69) Dia. Spotface
4 Places 35(1.38)
29.5
7(.28) Dia. (1.16)
8(.31) Deep 100.8 23(.91) Dia. 50
2 Places (3.97) "C" Thd. (From Rear) (1.97)
4 Places
12.5 126.2
(.49) (4.97)
156
(6.14)

DIMENSIONS IN
MILLIMETRES (INCHES)
DHGM- 06 -5080
06X
D

E
M12 Thd. 1/4 BSP.F Thd.
204 24(.94) Deep 4 Places F
(8.03) 6 Places
12 180 50 H
(.47) (7.09) (1.97)
25 130.2 35 J
(.98) (5.13) (1.38)

T Y P T
PY
(5.28)

(4.33)

(3.63)

(4.57)
92.1
110

V
116

W V
134

(2.94)
(2.88)
(.47)
11.9

74.6
73.1

W B A
(1.81)

X A B
46.1

X
(.35)

(.69)

(.75)
17.5

19.1
8.9
(.47)

12.5 N
12

11(.43) Dia.
(.49)
4 Places
156 L
(6.14) "C" Thd.
24.5(.96) Dia. 4 Places
4 Places K

Sub-plate Dimensions mm (Inches)


"C" Thd.
Model Numbers D E F H J K L N
DHGM-06-5080 3/4 BSP.F 151.2 (5.95) 137.7 (5.42) 102 (4.02) 54.4 (2.14) 30.6 (1.20) 125.8 (4.95) 78.2 (3.08) 42.5 (1.67)
DHGM-06X-5080 1 BSP.F 155.2 (6.11) 148 (5.83) 106 (4.17) 50 (1.97) 25 (.98) 130 (5.12) 74 (2.91) 32 (1.26)
For other dimensions, refer to "DHGM-06 -50/5090" above.
For Uses of Port "X", "Y", "V", "W", refer to DHGM-10 on the following page.

402 Solenoid Controlled Pilot Operated Directional Valves


Options

Models with Pilot Choke Valve


Terminal Box Type Plug-in Connector Type
DSHG-03- -C1/C2/C1C2 DSHG-03- -C1/C2/C1C2- N
N1
Fully Fully Extended
Extended 37.5 59
37.5 59 (1.48) (2.32)
(1.48) (2.32)

SOL a SOL b
SOL a SOL b A

J
C
D

E
E

F
F

H
H

(S-)DSHG-04- -C1/C2/C1C2 (S-)DSHG-04- -C1/C2/C1C2- N


N1
Fully Extended Fully Extended
59 59
(2.32) (2.32)

SOL a SOL b SOL a SOL b

J
C
D

E
E

F
H

H
(S-)DSHG-06
10 - -C1/C2/C1C2 (S-)DSHG-06
10 - -C1/C2/C1C2- N
N1
Fully Extended Fully Extended
59 59
(2.32) (2.32)

SOL a SOL b SOL a SOL b

J
C
D

E
E

F
F

H
H

1. "C1" Choke Adj. Screw 6 (.24) Hex.


2. "C2" Choke Adj. Screw 6 (.24) Hex.
DIMENSIONS IN
3. Lock Nut 12 (.47) Hex. MILLIMETRES (INCHES)

Dimensions mm (Inches)
Model Numbers J
C D E F H
AC SO L DC SO L R SOL
DSHG-03- -C1 100 (3.94)
198.8 (7.83) 180.5 (7.11) 133.5 (5.26) 198.5 (7.81) 209.5 (8.25) 212.5 (8.37)
DSHG-03- -C2 100 (3.94)
DSHG-03- -C1C2 223.8 (8.81) 205.5 (8.09) 158.5 (6.24) 125 (4.92) 100 (3.94) 223.5 (8.80) 234.5 (9.23) 237.5 (9.35)
(S-) DSHG-04- -C1 106 (4.17)
204.8 (8.06) 186.5 (7.34) 139.5 (5.49) 204.5 (8.05) 215.5 (8.48) 218.5 (8.60)
(S-) DSHG-04- -C2 106 (4.17)
(S-) DSHG-04- -C1C2 229.8 (9.05) 211.5 (8.33) 164.5 (6.48) 131 (5.16) 106 (4.17) 229.5 (9.04) 240.5 (9.47) 243.5 (9.59)
(S-) DSHG-06- -C1 127 (5.00)
225.8 (8.89) 207.5 (8.17) 160.5 (6.32) 225.5 (8.88) 236.5 (9.31) 239.5 (9.43)
(S-) DSHG-06- -C2 127 (5.00)
(S-) DSHG-06- -C1C2 250.8 (9.87) 232.5 (9.15) 185.5 (7.30) 152 (5.98) 127 (5.00) 250.5 (9.86) 261.5 (10.30) 264.5 (10.41)
(S-) DSHG-10- -C1 190 (7.48)
288.8 (11.37) 270.5 (10.65) 223.5 (8.80) 288.5 (11.36) 299.5 (11.79) 302.5 (11.91)
(S-) DSHG-10- -C2 190 (7.48)
(S-) DSHG-10- -C1C2 313.8 (12.35) 295.5 (11.63) 248.5 (9.78) 215 (8.46) 190 (7.48) 313.5 (12.34) 324.5 (12.78) 327.5 (12.89)

404 Solenoid Controlled Pilot Operated Directional Valves


DIRECTIONAL CONTROLS

Options

Models with Stroke Adjustment

DSHG-03- -R Fully Extended


252 (9.92)

Lock Nut 17(.67) Hex.


SOL a SOL b

(1.38)
35
Stroke Adj. Screw (Port "A" End) 99 (3.90) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex. Fully Extended 13 (.51) Hex.

(S-)DSHG-04- -R Fully Extended


289 (11.38)
E
SOL a SOL b
Lock Nut 17(.67) Hex.

(1.30)
33

Pilot Operated Directional Valves


Stroke Adj. Screw (Port "A" End)
93 (3.66) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex.
Fully Extended 13 (.51) Hex.

(S-)DSHG-06- -R

Solenoid Controlled
10 Fully Extended
C

SOL a SOL b

Lock Nut 24(.94) Hex.


E

Stroke Adj. Screw (Port "A" End) Stroke Adj. Screw (Port "B" End)
17 (.67) Hex. D 17 (.67) Hex.
Fully Extended

Model Numbers C D E
(S-)DSHG-06- -R2 376 (14.80) 111 (4.37) 40 (1.57)
(S-)DSHG-10- -R2 558 (21.97) 164.5 (6.48) 65 (2.56)

DIMENSIONS IN
MILLIMETRES (INCHES)

Pressure Centred Model s Models with Pilot Piston


(S-)DSHG- 06-3H (S-)DSHG- 06- -P
10 C
10 C

SOL a SOL b SOL a SOL b

D
D

Model Numbers C D Model Numbers C D


(S-)DSHG-06-3H 306.5 (12.07) 102 (4.02) (S-)DSHG-06- -P2 323 (12.72) 84 (3.31)
(S-)DSHG-10-3H 456 (17.95) 149.5 (5.89) (S-)DSHG-10- -P2 479 (18.86) 125 (4.92)

Solenoid Controlled Pilot Operated Directional Valves 405


DIRECTIONAL CONTROLS

■ List of Seals and Pilot Valves

(S-)DSHG-04- - -52/5290

15 14 16 17

Pipe Plug
Pipe Plug Removed for Internal
11 Removed for Internal Pilot Models
Drain Models
SOL a SOL b 11

X
Y 12

E
X Y Section Y-Y Section X-X
18 10 5 4 1 3 9 13 8 2 7

(S-)DSHG-06- - -53/5390

Pilot Operated Directional Valves


(S-)DSHG-10- - -43/4390
Pipe Plug
15 14 16 17 Removed for Internal

Solenoid Controlled
Pipe Plug Drain Models
Removed for Internal
Pilot Models 11
11

SOL a SOL b

21 21 12
X

X 12
Section X-X

Section Y-Y 11 Pipe Plug


Y Removed for External
18 2 10 5 3 1 9 13 8 4 7 Drain Models

Note: Item 21 orifice marked is applicable to pressure centred models


(3H ) with pilot pressure more than 10 MPa (1450 PSI).

List of Seals Pilot Valves


Part Numbers See page 408 for the pilot valve model numbers to
Item Name Qty. be used.
(S-)DSHG-04 (S-)DSHG-06 (S-)DSHG-10
8 SO-NB-P9 SO-NB-P14 SO-NB-P20 2
9 SO-NB-P22 SO-NB-P30 SO-NB-P42 4
O-Ring
10 SO-NB-P34 SO-NB-P40 SO-NB-P65 2
18 SO-NB-P9 SO-NB-P10 SO-NB-P14 2

Note: When ordering the o-rings, please specify the seal kit number listed in page
408. In addition to the above o-rings, o-rings for pilot valve is included in
the seal kit.
For the detail of the pilot valve o-rings, see page 359.

Solenoid Controlled Pilot Operated Directional Valves 407