TECHNICAL DATA
Generator Constant potential, microprocessor-controlled
Working frequency 145-230 KHz (typically 175 KHz)
Focal spot 0.4 mm (IEC 336)
Anode current 4 / 8 mA
06/2021
Voltage at X-ray tube 60 / 65 / 70 kV (*)
Exposure time 0.020 – 1.000 seconds, R’10 and R’20 scale RXDC
Source-skin distance 20 and 30 cm
X-ray unit
erSphe
yp
re
Te y
c h n ol o g
www.my-ray.com
BU Medical Equipment
Plant - Via Bicocca, 14/c - 40026 Imola - Bo (Italy) tel. +39 0542 653441 - fax +39 0542 653555
Headquarters - Cefla s.c. Via Selice Provinciale, 23/a - 40026 Imola - Bo (Italy) tel. +39 0542 653111 - fax +39 0542 653344
Cefla North America, Inc. 6125 Harris Technology Blvd. Charlotte, NC 28269 - U.S.A. Toll Free: (+1) 800.416.3078 Fax: (+1) 704.631.4609
2 RXDC, X-ray unit with HyperSphere technology 3
erSphe
yp
RXDC
re
Te
Hyper Technology.
c y
h n ol o g
FREE TO MOVE
Maximum freedom of movement
with innovative ball joint
(Patented).
Innovative design, revolutionary ergonomics, advanced technology.
RXDC - HyperSphere technology brings the best of DC X-ray units
into your surgery.
MyRay, just right for you.
The wireless remote A constant potential The RXDC unit Built from high quality
controller, the multi- head tube (8 mA) features HyperSphere materials and featuring
mode option and the with a tiny focal spot technology which, a comprehensive array
28 adjustment levels (0.4 mm at 30 cm) thanks to the full-swivel of equipment. Versatile
(depending on sensor produces optimal ball joint, can reach any and easy to install, this
sensitivity) ensure full images under all position with ease. X-ray unit is reliable
adaptability whatever circumstances. whatever the situation.
your operating
requirements.
Hyper Ergonomy.
RXDC - HyperSphere technology allows attainment of any
position with ease thanks to the revolutionary ball joint.
EASY TOUCH
Outstanding ergonomics ensures all your diagnostic needs are Effortless locking, release and
repositioning.
met effortlessly.
HyperSphere technology gives the RXDC unit electro-brake with touch-sensitive control
full rotation capability. The tube revolves freely
around the joint, allow it to reach practically any infinite position range
position, including the vertical. maximum versatility
RXDC - HyperSphere technology also features COMFORT POSITIONING
an automatic touch-sensitive device for simple, complete reliability Two comfortable handles for a
secure grip and the best possible
efficient locking/release of the X-ray head tube positioning.
so it can be repositioned effortlessly between
one exposure and the next. Ergonomic zones
on the sides of the head provide a firm grip for
effective positioning.
Extensive positioning.
MULTI-MODE
Maximum flexibility to meet your diagnostic needs.
Automatic parameter modulation ensures exposure
Hyper Performance.
power and time are always selected according
to the patient’s build and the specific region of
investigation.
1% 10% 100%
Sharp images at all times RXDC - HyperSphere
IMAGE BLURRING OPTIMAL DEFINITION
technology provides your surgery with
FOCAL SPOT optimum X-ray quality whatever the type of
0,4 mm sensor connected. Now even more powerful,
FOCAL SPOT with 70 kV and 8 mA, even more flexible and
COMPLETE EQUIPMENT SET
0,8 mm suitable for all commercially available sensors. RXDC - HyperSphere technology features a 30 cm
The constant potential head tube, associated cone with a circular and rectangular collimator.
with the smallest intraoral imaging focal spot The rectangular collimator is ideal for reducing the
available (0.4 mm), ensures the best images X-ray dose administered to the patient as it limits
whatever your diagnostic needs. the irradiated body area to the effective capture
capacity of the sensor.
High definition diagnostic.
DETECTOR DETECTOR