XEC 12 VDC Electric Actuators For Choke Valves
XEC 12 VDC Electric Actuators For Choke Valves
XEC 12 VDC Electric Actuators For Choke Valves
The XEC Series is our standard recommendation for use with choke valves.
Please see our full product line of electric actuators for applications with other
requirements.
»» XE Series 12 VDC should be used instead for cases where the customer is
using a valve controller (such as TotalFlow by ABB®).
»» XC Series (XC-00690B) is available for applications that are required to meet
CSA Approved Class I, Division 1 & 2, Groups C, D standards. Motor control
C US
258948
board is not available in CSA model.
262375
Wiring Diagram
in
USA
PWR
by ABB®).
»» XC Series (XC-00690B) is
TB1
12VDC 1
POWER
2
available for applications that
3
4 TRIAC
are required to meet CSA
approved standards: Class I,
TM-12VDC-AMP
5
TRIP CONTACT
CLOSE ON TRIP 6
Division 1 & 2, Groups C, D.
TRIP
P1
TRIP
Motor control board is not
US available in CSA model.
1. CONNECT 12VDC (BATTERY SOURCE) TO TERMINALS 1 & 2.
POSITIVE ON TERM 1 / NEGATIVE ON TERM 2 - ACTUATOR WILL DRIVE CW C
POSITIVE ON TERM 2 / NEGATIVE ON TERM 1 - ACTUATOR WILL DRIVE CCW 258948
262375
2. IF TRIP SETTING NEED AJUSTMENT AFTER VALVE ASSEMBLY HAS BEEN INSTALLED IN THE FIELD
TURN THE TRIP POTENIOMETER CCW UNTIL IT STOPS.
WHILE THE ACTUATOR IS MOVING TURN THE TRIP POTENTIOMETER CW UNTIL THE TRIP RED LED GOES OUT. JOG THE ACTUATOR BACK AND FORTH
MAKING SURE THE TRIP LED STAYS TURNED OFF.
3. CONNECT PLC DISCRETE INPUT TO TERMINALS 5 & 6. PLC LOGIC SHOULD DE-ENERGIZE ACTUATOR OR REVERSE ACTUATOR TO CLEAR VALVE JAM. THE
TM-12VDC-AMP CIRCUIT BOARD DOES NOT CONTROL THE ACTUATOR, ONLY COMMUNICATES WHEN THE ACTUATOR MOTOR HAS STALLED.
Dimensions (IN)
Model ISO 5211 A B C D sq E F G H I J K L M N O P Q X Y Z
XEC-690B* F07 M8 0.47 2.756 0.669 3.46 0.12 1.26 1.97 6.18 2.01 3.94 2.76 6.57 2.09 1.57 2.36 4.72 10.16 6.69 9.25