Comen NC12 SemiModular Patient Monitor
Comen NC12 SemiModular Patient Monitor
Comen NC12 SemiModular Patient Monitor
Environment light
sensor, screen
brightness
Alarm indicator auto-adjustment, save +593 2-252-6858
info@abamedyc.com
NC12 power consumption
light for observation Gaspar de Carvajal N29-141 y Obispo Diaz de la Madrid. | Quito - Ecuador
Wireless and wired Other bed observation, facilitate patients Fanless design, avoid cross contamination on
network; monitoring of the hospital workers; laminar, supreme quiet;
Support external printers(A4 paper), 12 leads 48h all disclosure waveforms review, monitoring records browse
ECG waveforms printing; and review function;
Patient Monitor For the convenience and utility of clinical usage, we seek for innovation wholeheartedly
Simple, reliable, multi-functional remain to be keywords of bed-side patient monitor. Being focused on these keywords,
Comen NC Series patient monitor is created to serve bed-side monitoring with a smarter idea: Semi-modular. Flexible Modular and Comprehensive Care Options
It is lighter, smarter, more powerful, and even more beautiful, than ever. The new generation of Comen’s semi-modular monitors offers the most commonly used parameters, including ECG,
NIBP, SpO2, RESP, TEMP and dual IBP. With its modular design, it is able to be equipped with modules based on clinical
needs. Alternative usage of the modules makes the clinical work more convenient and efficient.
diagnostic. consumption of
ECG acquisition
modules are reduced to
improve coherence of
each lead.
During the process of R&D, our engineers found 4 major reasons that cause high power consumption, they are low power
conversion efficiency, high power consumption on main board, ECG board and screen. Aimed at solving those problems,
Comen’s NC series are changed with a new power conversion IC to improved 10% of its efficiency. Adding overvoltage and
overcurrent protection to make the unit more safety and reliable. With more efficient power management system, the power C.O.
consumption on main board was reduced by 40%. What’s more, its standby current was decreased from 1.2mA to less than
200uA; therefore standby time of the battery was extended. Adopt conventional thermodilution invasively
measure and calculate the cardiac output and
Reducing power consumption also brings a variety of benefits: fanless design, long life time of battery, strong anti-aging other hemodynamic parameters.
ability of the components, long life time and stable performance of the products, meanwhile, the whole unit is smaller and
more delicate. C.O. Display