B - LUB - BSB - DS 100litros

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

BS-B Lubricator

Electric, Grease

General
The BS-B Lubricator is used in cases where a lot of lubrication points shall centrally and reliably be
supplied with lubricant. BS-B is also suitable for filling and lubrication systems.

Application
The BS-B pump is ideally suitable for applications where long extended main line runs and a large
number of friction points are to be reliably served from one central station. In conjunction with
distributors type ZV-B downstream the pump is predominantly used in dual-line centralized systems,
but also as filling-or greasing pump.

Operation When using a hydraulic changeover valve,


do not exceed the maximum operating
Basically it consists of a body with plunger assembly and reservoir. The rotation is converted inside pressure rating of valve.
the pump head into an oscillating movement. The BS-B double-acting pump has two pairs of plunger
(feed pistons and pilot pistons) which move simultaneously into a common bore.
The BS-B pump should always be mounted
Whilst one pair of pistons is on the suction stroke in one bore, the other pair forces the lubricant in a in a vertical position. Check motor
second bore into the pressure channel. The pilot pistons are positively-controlled i.e. they are connections so that rotation of the pump
shaft is counter-clockwise (motor fan
displaced mechanically into is end position following each cycle, thus preventing blocking, as is likely runs in a counter-clockwise direction).
to occur with hydraulically-or spring-controlled plungers.

The required feed pressure is adjustable thanks to an integral pressure relief valve. In the event of
an inadmissibly overpressure situation occuring an additional safeguard (burst plates) is
incorporated to protect the pump element from damage. The pump need not be bled.

Features
++ High reliability due to forced control
++ Pump can be supplied complete with a geared motor
++ Long service life thanks to the use of wear-resistant high-grade steel
++ Compact and rugged design
++ Surface signal grey RAL 7004

Technical Data
Maximum working pressure 5800 psi (400 bar)
Discharge 7, 14 & 22 liter/h, dependant upon driving speed
Maximum outputs, nominal 80 rpm 7.3 cu. in./min. (120cc/min.)
(ref. motor sizes)
160 rpm 14.3 cu. in./min (235cc/min.)
250 rpm 22.2 cu. in./min. (365cc/min.)
Reservoir capacity 60 liter (126 lb), 100 liter (210 lb)
BIJUR DELIMON INTERNATIONAL
Grease Up to NLGI grade 2
(919) 465 4448 LOCAL
Other greases and oils Consult Bijur Delimon (800) 631 0168 TOLL-FREE
(includes synthetic types) (919) 465 0516 FAX
Temperature range (ambient) -5˚F to 176˚F (-20˚C to 80˚C) WWW.BIJURDELIMON.COM
Built-in pressure relief value 0 to 5800 psi (0 to 40 bar) 2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

1 35515 • R1 06/09
Maintenance
Ensure that only clean lubricant is used in pump and reservoir. When replenishing grease, always
fill reservoir through the refill connection coupling provided on the unit. This action minimizes
introduction of air pockets into lubricator and distribution system.

How to Order

BSB 0 0
1 A1 A 0

Number of Outlets Accessories


01— 1 outlet 00— No accessories
01— Level switch
Revision Level 02— Pressure gauge
A— Revision A 03— Level switch & pressure gauge

Flange Mounted Gear Motor Reservoir Capacity


01— 1 hp (80 rpm) A— 60 liter (126 lb) reservoir
220/240V, 380/415 V 50 Hz: three phase B— 100 liter (210 lb) reservoir
02— 1 hp (80 rpm)
290/305 V, 500/525 V 50 Hz: three phase Drive Position
03— 2 hp (160 rpm) 0— Without
220/240 V, 380/415 V 50 Hz: three phase
04— 2 hp (250 rpm)
220/240 V, 380/415 V 50 Hz: three phase
05— 1/2 hp (80 rpm)
220/240 V, 380/415 V 50 Hz: three phase

The BS-B Lubricator features a smart part number ordering system, where you can tailor the pump
to meet your needs. First, choose the number of outlets, revision level, flange mounted gear motor,
drive position, reservoir capacity and accessories you need. Then, put the numbers into the
corresponding squares in the easy-to-use grid. You now have the customized part number.

Example: To order a 1 outlet, revision A, 1/4 hp (63 rpm) flange mounted gear motor, without drive
position, 8 liter reservoir, with level switch, you would use
Part #01A010A01.

A level switch is available for the indication of the filling level in the reservoir, using a proximity
sensor. As soon as the minimum or maximum level allowed has been obtained, a signal is released.
With the help of a signal lamp at the reservoir, this signal can be used for the visual warning or for
the control of an automatic filling facility.

In case of receiving the order, we will attach particular operating instructions to the level switch with
the following code: BA_2005_1_GB_76951_6011.

BIJUR DELIMON INTERNATIONAL


(919) 465 4448 LOCAL
(800) 631 0168 TOLL-FREE
(919) 465 0516 FAX
WWW.BIJURDELIMON.COM
2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

2 35515 • R1 06/09
Dimensional Schematics Measurements shown in millimeters.

A
B C

FILLER VALVE

PRESSURE PORT PRESSURE


3/8” BSPP RELIEF VALVE
RELIEF PORT
GEAR MOTOR 3/8” BSPP

ø9
138.5
34
87.5 107.5
10
21
107 112.5
70
225
100
255
D

30

Dimensions (mm)
Design A B C* D
Reservoir Capacity 16.5 lb. (8 liter) Ø 190 595 785 ---
31.5 lb. (15 liter) Ø 240 630 870 ---
63 lb. (30 liter) Ø 310 700 1010 ---
Motor Power Rating 1/2 hp for 63 rpm --- --- --- 406
1/2 hp for 63 rpm --- --- --- 432
1/2 hp for 125 rpm --- --- --- 424 BIJUR DELIMON INTERNATIONAL

* Dimension when lid is open (919) 465 4448 LOCAL


(800) 631 0168 TOLL-FREE
(919) 465 0516 FAX
WWW.BIJURDELIMON.COM
2100 Gateway Centre Blvd., Suite 109
Morrisville, NC 27560

3 35515 • R1 06/09