Datacenter Infrastructure

Management System (DCIM)

Presented by
Chan Nyein
What is BIM?

Building Infrastructure monitoring provides insights and


visibility into the health and status of building by
tracking specific metrics in real time and sending alerts
or notifications when readings exceed or fall below the
set thresholds. Data collected from monitoring of
building can be stored, analyzed, and displayed in
business intelligence and analytics dashboards and
reports in DCIM software to make data-driven building
management decisions.
What is DCIM?

Data center monitoring provides insights and


visibility into the health and status of data
centers by tracking specific metrics in real time
and sending alerts or notifications when
readings exceed or fall below the set thresholds.
Data collected from monitoring of data center
can be stored, analyzed, and displayed in
business intelligence and analytics dashboards and
reports in DCIM software to make data-driven data
center management decisions.
Why Should we use RDU 501 Monitoring System
The RDU 501 provides integrated surveillance,
sensing, access control, and advanced alerting
for IT environments of all sizes, from single-
rack edge networks to large data centers.
Features

• Manage up to 4 cameras with NVR and directly 1 x IP Camera


• 32 Sensor without THUB and 80 Sensors with THUB (max)
• 12 Digital Input Sensors without 8DIAI Cards , up to 44 Sensors with extension Cards and 18 Outputs (Max)
• Analog Inputs 16 Units (Max) and 32 Outputs (Max)
• RS485/SNMP can be used 32 devices by default and up to 64 devices with license
• Alarming via email or SNMP based on user-configurable thresholds
• Integration with RDU-M Monitoring Software for long-term data and video storage
• Secure web-UI management

RDU 501 Controller


Components

Temperature sensor T & H sensor Alarm Beacon Smoke sensor


Module

Water Leakage Sensor Digital Input Sensor Infrared Sensor Door Contact Sensor
DCIM Architecture
DCIM Architecture
DCIM Architecture with RDU-M Server
Smart Aisle 2 offers high end architecture
Individual Containment Monitoring Platform

Containment Containment Power SMS&


IP Camera Rack PDU Door Reader Email
Meter Seamless
(4 units) (48 units) (2 units) Web Based Monitoring Alarm HMI Touch
(2 units) Integration
notification Screen
to BMS
Display
System

High Level
RDU501
Interface

Dry Contacts
Generator
(2 Units)

RDU THUB

Water Leak Environmental


VRF UPS In Row
Detection Sensors
(2 units) (2 units) Cooling
System
(4 units)
(1 unit)

Suppression Alarm
Temperature & Humidity Openable Panel Panel
Beacon Light Infrared Detector Sensor ( 20 units) Roof sensor (3 units) (1 units)
(2 units) (1 unit)
OVERVIEW

• RDU-THD includes the main module (THD-M) and the series temperature and humidity strings (THD-S),
and is used to monitor the rack environmental (such as temperature, humidity, and door status). The
communication ports of THD-M support MODBUS protocol with RS-485. The RJ45 ports on both sides
of the THD-M support T/ TH/ DI /AI sensors.

TH

T
T

RDU – THD
M (Manager)

12 RDU – THD S (String) RDU – THD S (String)

*Additional Notes
OVERVIEW

T TH T
Inrow Cooling and VRF Installation
RDU501
LAN / RS485

LAN Cable

I-Touch Manager( 1 Unit )

Sequence Cables

Inrow Coolings ( 4 Units )

VRF ( 4 Unit )
UPS & Battery, Generator and Power Meter Installation
RDU501

LAN / RS485 LAN

RS 485 Generator (2
Units)

Electrical
Connections

Power Meter ( 2 Units )

Battery
Connection

UPS ( 2 Units) Battery Frame Generator

( 4 Units )

Transformer
PDU Installation for 22 Racks ( 48 no)

3 rd Party
LAN Cable Network Switch

RDU501

48 PDU Units
Containment Sensors Installation

RDU501

CCTV System Door Access System Horn Strobe


Water Leakage Infrared Open Roof
(4 units) (2 units) Light
Controller (1 Unit) Detector
(2 units)
RDU 501 Monitoring View