NFPA 13: Finding the section and answer Date :
1. Sprinklers under glass or plastic skylights exposed to the direct rays of the sun shall be of the _________
temperature classification.
a) intermediate b) ordinary
3. Hydrostatic testing per NFPA-13 requires that the hydrostatic testing be performed with the clapper off its seat if
the valve is:
4. A new dry pipe system shall be tested for 24 hours with
5. The distance between a hanger and the centerline of an upright sprinkler shall not be less than
a) 3 inches b) 4 inches
c) 5 inches d) 6 inches
6. A minimum clearance between the top of storage and a standard spray pendent sprinkler's deflector shall be?
a) 24 inches b) 18 inches
c) 12 inches d) 6 inches
7. A one inch auxiliary drain valve on a wet-pipe system is required for an isolated trapped section of pipe when
the capacity of that section is more than
a) 10 gallons b) 20 gallons
c) 25 gallons d) 50 gallons
https://quizizz.com/print/quiz/59fdae225fb948100098d2b5 1/4
11/4/2017 Quiz - Quizizz
8. The minimum stock of spare sprinklers that shall be maintained on the premises for a sprinkler system having
less than 300 sprinklers is
a) 3 spares b) 6 spares
c) 12 spares d) 18 spares
9. The maximum size pipe that may be supported by a toggle in metal lath and plaster ceilings is ____inch
a) 1 b) 1 1/4
c) 1 1/2 d) 2
10. The gallons per minute required by NFPA 13 to flush 6" pipe is:
a) 550 b) 880
c) 1000 d) 1560
a) 5/8" b) 3/4"
c) 7/8" d) 11/16"
12. The number of sprinklers that can be used on a 2" copper pipe in pipe schedule systems in ordinary hazard
occupancy is:
a) 10 b) 12
c) 14 d) 8
a) a toilet b) a sink
15. Of the four items listed, the one required to be listed for Fire Sprinkler system applications is;
a) Signs b) Hangers
16. The temperature rating for a sprinkler with a green or yellow glass bulb is:
https://quizizz.com/print/quiz/59fdae225fb948100098d2b5 2/4
11/4/2017 Quiz - Quizizz
18. Check valves are allowed to be used to separate sections of dry systems:
a) never b) always
20. The maximum width of an exterior canopy that a Dry pendent sprinkler could cover, if the dry pendent sprinkler
is listed for and installed at a 45 degree angle in the corner where the roof meets the exterior canopy wall is:
a) 4' b) 5'
21. Not more than ____automatic sprinklers shall be controlled by any one preaction valve on a single-interlock
system.
a) 500 b) 750
c) 1000 d) 1250
22. A hanger needs to support 5 times the weight of water filled pipe plus:
23. The distance from the last hanger on a 2” piece of pipe to the end of the pipe cannot exceed:
a) 36" b) 45"
c) 60" d) 72"
24. The parts of a hanger assembly that are required to be listed are:
https://quizizz.com/print/quiz/59fdae225fb948100098d2b5 3/4
11/4/2017 Quiz - Quizizz
25. When supporting a run of 6 inch sprinkler main entirely with expansion shields in the vertical position, their
maximum spacing apart is:
a) 5 feet b) 8 feet
c) 10 feet d) 12 feet