3B40ZC5570P1 Fe55av - Specifications
3B40ZC5570P1 Fe55av - Specifications
3B40ZC5570P1 Fe55av - Specifications
SPECIFICATIONS
CONTENTS
〔Contents〕
Contents ……………………………… 1
Product Specifications ………………2
Installation Conditions …………… 4
Caution on Piping ……………………8
Electric Power Facilities ……………10
Lubricating Oil ………………………12
Warranty Conditions / Indemnity … 13
PRODUCTS SPECIFICATIONS
(V)
Poles 6P
Protection IP44
Cooling system Air cooling
Starting system Inverter
Insulation class F
Type (kW) 2.2
Fan motor
◆Inverter parts
Model MAIN INVERTER
Items (Inverter for IPM motor)
Frequency (Hz) 50
properties
Electric
INSTALLATION CONDITIONS
1.INSTALLATION SITE
○ Install the unit where indoor and well ventilated.
Since this machine is manufactured to be used indoors, do not install it outdoors.
○ The cleaner the suction air is, the longer the machine (life is).
Do not install the machine especially at such place where there are a lot of dust,
the noxious gas such as chlorine gas, hydrogen sulfide gas, sulfur dioxide, ozone of
high density, basement, highly humid and etc.
○ Do not install the machine where the ambient temperature exceeds 40℃.
Operation in a room at higher than 40℃ causes thermal trip and other troubles.
Be sure to observe the allowable temperature range by installing a ventilation fan
in the room where the compressor is
installed.
○ Make spaces for maintenance around
a machine. Secure the front more than
600mm for the opening and closing of
the door, operation, maintenance.
Secure the upper face more than
1000mm for the normal exhaust function
security. Secure the left-right both side
more than 600mm and the rear face
more than 500mm for maintenance.
○ When unloading or carrying, use the openings on the base plate of the compressor.
They are large enough to fit forklift forks, which allows unloading and carrying by
a forklift.
Please use a suitable instrument
(wire, nylon sling, reliance board etc.)
after referring to the weight of the unit
of products specifications.
2.CAUTION IN INSTALLATION
○ Install the unit on a horizontal floor and don't install it on the shape steel and
the block.
○ Perform foundation works on 2 positions; the compressor front and rear, with
the foundation bolts and foundation bolt patches attached as standard accessories.
○ A ground terminal is installed on the operation panel. Be sure to connect the ground
cable to the terminal.
P5
○ The life of the compressor will shrink extremely if it is operated without installing
the air tank.
○ Provide the size of the air intake so as not to produce negative pressure in the room.
○ Select the ventilating fan bigger than the following table.
○ Be careful for the exhaust heat is going to circulate at the air intake , and the ambient
temperature is higher if the ceiling is lower.
○ The compressor may be tripped at the room temperature of 40℃ or higher, so it must
be improved.
○ Select the position of ventilating fan where the compressor doesn't take a ventilating
air again.
Notes)
1. The local ventilation system expresses how to install a ventilating fan in the nearness
of the exhaust port of a compressor unit. 1/3 - 1/2 of the air capacity which are
exhausted from a compressor discharge to the exterior by the ventilating fan directly.
2. The quantity of the ventilation shows the flow rate at the time of making an indoor
allowable-temperature rise into 5℃ to open air temperature.
P6
・The ventilation capacity is ・Calculate the pressure loss (resistance) ・The pressure loss (resistance) in
for ventilating the entire in the ventilating duct based on the the ventilating duct is over 50Pa
room. exhaust air volume of the compressor. (5mmH2O), install a ventilating fan
(at the allowable room If the result is not more than 50Pa with the specified capacity inside
temperature of 5゚C higher (5mmH2O) , the exhaust from the duct taking the pressure loss into
than the ambient the compressor exhaust outlet through consideration.
temperature) the duct will be possible.
・The air supply opening ・Connect the ventilating duct referring
should be adjusted so that to the duct installation mark at the top Caution
the flow rate will be 2m/s or of the compressor. The duct should be
less. removable. Do not fix the duct with In such a case, clearance "H" or
screws. It may hinder repair and 300mm to 400mm must be secured
(*1) maintenance work. between the ventilating duct inlet
Local ventilation is a ・Minimize bents in the duct to avoid and the compressor exhaust outlet.
method to exhaust air by resistance.
directly exhausting one ・When installing the duct, provide a full
third to a half of radius. Duct resistance over 50Pa ・Turn on the ventilating fan while
compressor-exhausted air (5mmH2O) could reduce the exhaust the compressor is running, and turn it
using a ventilating fan volume, causing temperature rise to off when the compressor is stopped.
installed near the stop the compressor. ・The opening area of air inlet shall be
compressor exhaust outlet. ・Even if the duct is connected directly adjusted so that the flow rate will be
to the compressor, the temperature will 2m/s or less.
rise. In such a case, install a
ventilating fan mentioned in
the P5 page (at the allowable room
temperature of 5゚C higher than
the ambient temperature).
・Prevent rain water from entering
the duct outlet.
・If the pressure loss in the ventilating
duct is over 50Pa (5mmH2O), install a
ventilating fan at the duct outlet.
(See method ③.)
・Follow the same installation procedure
to install a ventilating fan and air inlet
as that of entire ventilation.
The opening area for air intake shall be
adjusted so that the flow rate will be
2m/s or less.
P8
CAUTION ON PIPING
○ Provide a drainage at the bottom part of piping if there is concave or risen piping.
○ Install a riser piping away more than 500mm from the soundproof cover in
consideration for the maintenance of the compressor.
○ Don't equip a check valve between a compressor and air tank.
P9
2.OTHER PIPES
○ Install the pipe of 8A for the drain discharge from the drain separator.
P10
380・415V/50Hz (3ph) should be supplied to the unit. Remove the front cover and
introduce the power cable through the opening on the left side, then connect each cable
correctly to the terminal panel in the starting box.
For normal operation, a suitable power source is required. Secure less than ±5% of rated
voltage during operation. In order to suppress the imbalance of current, keep the rated
voltage within less than 2%.
Use appropriate cables and breaker tabulated above. Use of any wrong size cable may
overheat and burn the motor and cables. An inverter power cannot be used.
FE55AV 380/415 38 38 60 M 10
2 Screw size of
Model Earth (mm )
terminal panel
FE55AV 38 M8
P11
LUBRICATING OIL
AAA-OIL
KOBELCO GENUINE SCREW OIL
PC-HD11-509
3.MOTOR GREASING
○ The bearing part on the load side and unload side of the main motor needs
replenishing grease. Replenish our recommended genuine grease during operation
every 2,000 operating hours, by using a grease gun which injects grease under
pressure.
CAUTION
Never mix different oils.
Never fail to use the designated brand as to grease.
P13
WARRANTY CONDITIONS
1.WARRANTY CONDITIONS
The warranty period shall be 12 months after completion of the test run or 15 months
after shipment, whichever comes first.
※ “After completion of the test run” shall mean
[At the time when the test run (procedure and activities of receiving materials
test) is completed after installation at site.]
2.CONTENTS OF WARRANTY
In case a trouble should occur during the warranty period and when it is determined
that the trouble is caused clearly by our defective design, manufacture and/or
execution of work, we repair or replace the parts free of change without delay.
INDEMNITY
■ Indemnity
Under no circumstances shall, including any illegality, Kobe Steel, Ltd. be liable for
special, indirect, incidental, or consequential damages, including, but not limited to,
loss of production, loss of anticipated profits, loss of operational profits, loss of material
and products, or indirect losses, however same shall be caused.
P15
CONTROLLER
Monitor's main functions of indiction are as follows.
◆Indication of compressor's operating condition ' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 5 0 b a r ◆Emergency, Caution, and Maintenance Indications ' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 3 0 b a r
R U N N I N
G C O N D I T I ON 1 B A C K MA I N T E N A N C E B A C K
O I
L P R E S S . 0 . 6 0 b a r
The compressor's operating condition is indicated on 1 s t D I
S . P R E S S . 1 . 0 0 b a r In case of an emergency or caution, the screen shows C L OG G E D SU C . F I L T E R
2 n d D IS . P R E S S . 6 . 5 0 b a r
the screen, including running pressure, temperature, C U R R E N T 1 0 0 A what happens and how to deal with it, in addition to T
B
A K E
Y
OU T F I L T E R
B L OW I N G A I R
E L E M E N T
F R OM
A N D
I N S I D E .
C L E A N I T
O I L T E M P . 5 5 . 0 ℃
current, loading condition, running hour, running 1 s t D I S . T E M P . 1 2 0 . 0 ℃ its causes. C H A N G E E L E M E N T I F I T I S B A D L Y
2 n d SU C . T E M P . 5 2 . 0 ℃ C L OG G E D .
count, load hour, and load count. 2 n d D I S . T E M P . 1 6 0 . 0 ℃ Maintenance indication comes out on the screen
SU C . F I L T E R PR OG R E S S 0 h r 0 / R E S E T
automatically when maintenance is required and also
T O T A L R U N N I N G H O U R . 1 0 0 0 0 0 0 H r
【 NE X T 】 SV C . 4 0 0 0 h r
F 0 . 1 0 MOV E ▲ MOV E :+ R E S E T : E D I T
F 0 . 1 0
A E - 0 5
▲ MOV E
▼ MOV E E N T E R : S E L E C T shows when the next maintenance time comes. D E - 0 2 ▼ MOV E :- E N T E R : S E L E C T
' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 5 0 b a r
R U N N I N G C ON D I T I ON 2 B A C K
◆Graph Indication ' 0 2 / 1 2 / 3 1 2 3 : 5 9 # # . # # b a r
1 s t SU C . PR E S S . - 1 5 . 0 m b a r
1 s t SU C
P T 5
.
PR
T E
E
M
S
P
S
.
.
2
0
3
.
.
0
0
0
℃
b a r
Graph indication is a useful function to see [ b a r ]
H I
R U N N I N G R E C OR D [ D I S . PR E S . ] B A C K
T c
G E N E R A L
T
S I G
E
N
M
A
P
L
.
.
1 1 0 . 0
0
℃
%
the compressor's operating condition.
L OA D I N G C O
R U N N I N
N D I T
G C O
I
U
O
N
N
T
.
.
1
1 0 0 0 0
0
0
0
0
%
t i m e
Its indication mode has a function which shows both
L O
L OA
A D
D
H
C O
O
U
U
N
R
T
.
.
5 0 0 0
2 0 0 0 0
0
0
0
0
H r
t i m e
the operating condition in real time and running record.
F 0 . 1 0 The indicated data consist of five factors: the 2nd
A E - 0 9
discharge pressure, the 1st suction temperature, the L O
F 0 . 1 0 0 5 1 0 1 5 2 0
2nd discharge temperature, current, and loading rate. M E - 0 3 [ m i n ]
S E T U P O F C OM PR E S SOR S E T T I N G 1 B A C K
◆Running Record Indication ' 0 2 / 1 2 / 3 1 2 3 : 5 9 # # . # # b a r
Set up the compressor's operation setting on this O P E R A T I ON MOD E
PR E S S . D E T E C T ( O P T I ON ) L OC
A U T O MA N
R E M R U N N I N G R E C OR D B A C K
screen. U N L OA D I N G PR E S S . 6 . 9 0 b a r
L OA D I N G PR E S S . 6 . 5 0 b a r The compressor's running record is indicated on this R E C OR D ( E V E R Y 5 S E C )
Set up the setting of operation mode, pressure, and K E E P PR E S SU R E 6 . 3 0 b a r R E C OR D ( E V E R Y 1 H OU R )
A U T O S T A R T PR E S S . 5 . 7 0 b a r screen.
PID on “Setup of Compressor Setting 1”, and D A I L Y R E POR T
P I D S E T T I N G P = 7 5 I = 2 3 0 D = 0 The latest running record is indicated every five W E E K L Y R E POR T
the setting of operation method interlocked with a [ N E X T ]
seconds and every one hour.
dryer at an instantaneous stop or a power failure on
F 0 . 1 0 MOV E ▲ MOV E :+ R E S E T : E D I T E - S T O P & C A U T I ON R E C OR D
S E T U P O F W E E K L Y T I M E R B A C K
◆Alternate operation of two compressors ' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 3 0 b a r
F 0 . 1 0 MOV E ▲ MOV E :+ R E S E T : E D I T
B E - 0 6 ▼ MOV E :- E N T E R : S E L E C T
ISSUE
KOBELCO COMPRESSORS MANUFACTURING (SHANGHAI) CORPORATION DRAWING No.
P20
WIRING FOR AUTOMATIC ALTERNATE OPERATION
The wiring for automatic alternate operation, the setting and ・ THE SETTING POINTS
starting up of a compressor
1.WIRING
Setting of a compressor
Mutual wiring of the terminal panel in the starter panel of 2 compressors is as follows. ' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 0 0 b a r
the first unit the second unit ① Push “Enter” key after moving a cursor into R U N N I N G C ON D I T I ON
remote load order (XA terminal) (Y4 terminal) load operation output SETTING 1” appears. S E T U P OF C L OC K
R U N N I N G R E C OR D
F 0 . 1 0 ▲ MOV E
load operation output (Y4 terminal) (XA terminal) remote load order A E - 0 3 ▼ MOV E E N T E R : S E L E C T
COM 6 (COM 6 terminal) (COM 2 terminal) COM 2 ② Push “Enter” key after moving a cursor into【NEXT】 ' 0 2 / 1 2 / 3 1 2 3 : 5 9 6 . 3 0 b a r
(1) “SETUP OF COMPRESSOR SETTING 3” indicates that 【GROUP CONTROL】is set to B E - 0 1 ▼ MOV E :- E N T E R : S E L E C T
3.STARTING UP OF COMPRESSOR [ N E X T ]
F 0 . 1 0 MOV E ▲ MOV E :+ R E S E T : E D I T
Automatically alternate operation starts by pushing either “Start” button of 2 compressors. B E - 0 7 ▼ MOV E :- E N T E R : S E L E C T
The starting pressure of a slave unit's load operation / unload operation is controlled by
the value which is added the setting value of the slave unit's pressure differentials to
The first unit the setting value of pressure on “SETUP OF COMPRESSOR SETTING 1” (BE-01).
In the case of serious damage of the piping pressure, set it at a adequately large value.
(Never fail to set one is a Master and another a Slave.)
ISSUE
KOBELCO COMPRESSORS MANUFACTURING (SHANGHAI) CORPORATION DRAWING No.