Memmert Incubator IN110
Memmert Incubator IN110
Memmert Incubator IN110
IN110
The heating of this incubator is optimally tuned for natural convection and valuable chamber loads for research,
pharmaceutics, medicine and food chemistry are warmed up very carefully. On this page, you can find all the
essential technical data on our incubator. Our customer relations team will be pleased to help if you want further
information. If you should require a customised special solution, please contact our technical specialists at
sales@memmert.com.
Page 1/4 | 02.07.2023 Memmert GmbH + Co. KG | Tel. +49 (0) 9122/925-0 | E-Mail info@memmert.com | 0
DS_Memmert Incubator IN110 - en
Temperature
Setting temperature range +20 to +80 °C
Control technology
Language setting German, English, Spanish, French, Polish, Czech, Hungarian
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT the process time does not start until the set temperature is reached
adjustable parameters temperature (Celsius or Fahrenheit), air flap position, programme time, time zones,
summertime/wintertime
Ventilation
Convection natural convection
Fresh air Admixture of pre-heated fresh air by electronically adjustable air flap
Communication
Documentation programme stored in case of power failure
Programming AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet
interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software
available as accessory (on demand).
Safety
Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class
1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature
Standard equipment
Works calibration certificate incl. works calibration certificate for +37°C
Door fully insulated stainless steel door with 2-point locking (compression door lock)
Page 2/4 | 02.07.2023 Memmert GmbH + Co. KG | Tel. +49 (0) 9122/925-0 | E-Mail info@memmert.com | 0
DS_Memmert Incubator IN110 - en
Volume 108 l
Electrical data
Voltage 230 V, 50/60 Hz
Electrical load approx. 1400 W
Ambient conditions
Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance
from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances
must not be less than 5 cm.
Overvoltage category II
Pollution degree 2
Packing/shipping data
Transport information The appliances must be transported upright
WEEE-Reg.-No. DE 66812464
Page 3/4 | 02.07.2023 Memmert GmbH + Co. KG | Tel. +49 (0) 9122/925-0 | E-Mail info@memmert.com | 0