Data Sheet - Main Pump Jack Tools Zx350 - All
Data Sheet - Main Pump Jack Tools Zx350 - All
Data Sheet - Main Pump Jack Tools Zx350 - All
MATERIAL TAKE-OFF
D 1 BRAKET 1 mm D
2 PUSHER SHAFT 1 mm
3 STUD BOLT M16 1 mm
4 NUT FLANGES M16 1 mm
4 1
C 2 C
TOP VIEW
SCALE 1 / 2.5
B B
PLAN VIEW
SCALE 1 / 2.5
Name Date
CAUTION MEASUREMENT IN MM GENERAL TOLERANCE for MACHINING Drafter MDP 9/26/2022
CUSTOMER PT. HEXINDO
MASS SCALE AFTER 0.5 3 6 30 120 400 1000 Checked
PART
THIS DRAWING IS A PRIVATE AND 1/2 UP TO 3 6 30 120 400 1000 2000 Approved -
NAME MAIN PUMP JACK TOOLS ZX350
CONFIDENTIAL COMMUNICATION AND THE N/A GRADE TOLERANCE (in mm) COMPANY
A PROPERTY OF PT.GRACE TECHNIC. CAD FINE ±0.05 ±0.05 ±0.1 ±0.15 ±0.2 ±0.3 ±0.5 PART NUMBER / SERIAL NUMBER DRAWING NUMBER
A
IT MUST NOT BE COPIED OR DISTRIBUTED
1/3
WITHOUT THE CONSENT OR PERMISSION OF MIDDLE ±0.1 ±0.1 ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 GRACE TECHNIC PT.
PT.GRACE TECHNIC.
ROUGHT ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 ±2 ±3
ZX350 GT/MN/ENG-D
NOTE : DESIGNED FOR MATERIAL° ASTM A36 / ALUMINIUM A4
6 5 4 3 2 1
6 5 4 3 2 1
D D
12
13°
70
27
93.25
80
C C
20
186.5
165.5
54
230
224
30
12
10
21
6 100
50°
n14 THRU B
4X 12 30
A
5
SECTION B-B ANGLE 50X50X3
SCALE 1 / 3 202
SECTION A-A
B SCALE 1 / 3 B
PLAN VIEW ( ITEM 1 )
SCALE 1 / 3
Name Date
CAUTION MEASUREMENT IN MM GENERAL TOLERANCE for MACHINING Drafter MDP 9/26/2022
CUSTOMER PT. HEXINDO
MASS SCALE AFTER 0.5 3 6 30 120 400 1000 Checked
PART
THIS DRAWING IS A PRIVATE AND 1/3 UP TO 3 6 30 120 400 1000 2000 Approved -
NAME MAIN PUMP JACK TOOLS ZX350
CONFIDENTIAL COMMUNICATION AND THE N/A GRADE TOLERANCE (in mm) COMPANY
A PROPERTY OF PT.GRACE TECHNIC. CAD FINE ±0.05 ±0.05 ±0.1 ±0.15 ±0.2 ±0.3 ±0.5 PART NUMBER / SERIAL NUMBER DRAWING NUMBER
A
IT MUST NOT BE COPIED OR DISTRIBUTED
2/3
WITHOUT THE CONSENT OR PERMISSION OF MIDDLE ±0.1 ±0.1 ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 GRACE TECHNIC PT.
PT.GRACE TECHNIC.
ROUGHT ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 ±2 ±3
ZX350 GT/MN/ENG-D
NOTE : DESIGNED FOR MATERIAL° ASTM A36 / ALUMINIUM A4
6 5 4 3 2 1
6 5 4 3 2 1
D D
130
2.00 X 45.0° Chamfer
2 ALUMINIUM
n37.8 `.10
n40
C PLAN VIEW ( ITEM 2 ) n16.5 C
SCALE 1 : 1
300
M16x2
24
B B
Name Date
CAUTION MEASUREMENT IN MM GENERAL TOLERANCE for MACHINING Drafter MDP 9/26/2022
CUSTOMER PT. HEXINDO
MASS SCALE AFTER 0.5 3 6 30 120 400 1000 Checked
PART
THIS DRAWING IS A PRIVATE AND 1:1 UP TO 3 6 30 120 400 1000 2000 Approved -
NAME MAIN PUMP JACK TOOLS ZX350
CONFIDENTIAL COMMUNICATION AND THE N/A GRADE TOLERANCE (in mm) COMPANY
A PROPERTY OF PT.GRACE TECHNIC. CAD FINE ±0.05 ±0.05 ±0.1 ±0.15 ±0.2 ±0.3 ±0.5 PART NUMBER / SERIAL NUMBER DRAWING NUMBER
A
IT MUST NOT BE COPIED OR DISTRIBUTED
3/3
WITHOUT THE CONSENT OR PERMISSION OF MIDDLE ±0.1 ±0.1 ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 GRACE TECHNIC PT.
PT.GRACE TECHNIC.
ROUGHT ±0.2 ±0.3 ±0.5 ±0.8 ±1.2 ±2 ±3
ZX350 GT/MN/ENG-D
NOTE : DESIGNED FOR MATERIAL° ASTM A36 / ALUMINIUM A4
6 5 4 3 2 1
KETEBALAN LAS
NO DRAWING PICTURE WELD THICKNESS
1
Approvals
Institute CCS LR ABS GL BV DNV NK BKI KR CWB
3YS, H10 ⅢYMS(H10) KSW53G(C) H10
Grade 3YSMH10
3YM, H10
3YSAH10 3YH10S SA3YMH10 3YH10S 3YSMG(C1)H10 E491T-9-H8
KAW53MG(C) H10
Notice: 1) To avoid rust the wire must be kept in dry condition and keep the package in good condition also before
welding.
2) The surfaces to be welded must be cleaned away impurities of oil contamination, rust, moisture and so on.
3) The flow rate of shield gas should within 20L-25L/min in welding.
4) The wire extension should be 15mm-25mm.