AA00220 PC400-6 (Refuerzos PC400-6)
AA00220 PC400-6 (Refuerzos PC400-6)
AA00220 PC400-6 (Refuerzos PC400-6)
Remark
All measurements are shown in "mm" except where indicated.
PC400LC/HD-6 11 ft 1 in [3880 mm] Standard Arm only
PC400LC/HD-6 23 ft 2 in [7060 mm] Standard Boom only
1. Summary of installation
The arm and boom repair / reinforcement may require several parts to be fabricated. One or more of
the referenced reinforcing plates may be required depending on the failure location. After fabrication,
the reinforcement plates will be welded to the arm and boom. It may also be necessary to refer to the
welding manual for additional welding procedures not covered in this document. The final step will
include prime and finish painting.
3. Installation Drawings
C. PC400LC-6 and PC400HD-6 Arm Reinforcement Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 7
D. PC400LC-6 and PC400HD-6 Boom Reinforcement Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4. Welding information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5. Paint information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AA00220
Page 2 of 11
AA00220
Page 3 of 11
AA00220
Page 4 of 11
AA00220
Page 5 of 11
AA00220
Page 6 of 11
AA00220
Page 7 of 11
AA00220
Page 8 of 11
AA00220
Page 9 of 11
AA00220
Page 10 of 11
AA00220
Page 11 of 11
IMPORTANT WELDING REMARKS:
Electrodes must be stored in sealed containers until needed. Utilize only new dry low hydrogen welding
rod.
PAINT INFORMATION
Paint reinforcement plates and welds with yellow primer followed with a natural yellow finish coat.
Contact dealer / distributor or factory for paint availability.
AA00220