Technical Data

Cured Urethane
Cleanup
NMP Outperforms Methylene
Chloride & Formulated Products
If you are looking for a replacement for methylene chloride or expensive formulated products to
General
clean cured urethane residues from your tools or processing equipment, look no further than
NMP. There is, simply, no better and safer solvent for this difficult job.

This graph shows that NMP is 30% more effective than methylene chloride or commercial
formulated products for removing cured urethane foam from metal. The data shown is the
average foam removed using three rigid and one slab urethane foam cured on carbon steel for 24
hours. Soiled parts and tools are simply immersed in an NMP bath until the cured foam swells
and falls off the metal. No heating or agitation is necessary. Residual NMP can be rinsed off with
water.

NMP can be recycled by vacuum distillation, incinerated, or sent to reclamation. Lyondell


Chemical maintains a list of qualified NMP reclaimers.

Market Offerings The appropriate replacement solvent depends on the cure time of the foam, the type of foam, and
the customer’s specific price sensitivity.
• Cured foam (> 5 min)
If the customer is interested in a solvent that can be recycled and looks at total cleanup costs, we
recommend straight NMP. However, if the customer focuses on initial up front costs of the solvent,
a blend of NMP with other solvents (PMA, PC) will be cheaper but not recyclable. The charts below
and to the right compares the performance of these different solvent blends.

• Uncured foam (< 5 min)


Foam type has the greatest influence over solvent performance. The charts below show the
performance of our solvents.

% Urethane Foam Removed

NMP / GBL / THF

DMSO

Commercial A

NMP / GBL

NMP / PC

Commercial C

GBL

PC

0 20 40 60 80 100

Page 1 of 3
Flexible Urethane Foam
Foam immersed in solvent and tested
under high shear conditions
Recommend PMA
Clean-up Time (seconds)
Solvent PMDI TDI
Methylene Chloride 72 84
Glycol Ether PM 84 68
Glycol Ether PMA 40 31
NMP 180 34

Low Density Packaging Foam Foam


immersed in solvent and tested under
high shear conditions Recommend
PM
Clean-up Time (seconds)
Solvent 1-min cure 3-min cure
Methylene Chloride 40 Softens
Glycol Ether PM 36 Softens
Glycol Ether PMA 44 Softens

Cured foam in mixing head After immersion in NMP

High-Density Spray Foam


Foam immersed in solvent and tested
under high shear conditions
Recommend PM or PMA
Clean-up Time (seconds)
Solvent 1-min cure 4-min cure
Methylene Chloride 10 10
Glycol Ether PM 10 60
Glycol Ether DPM 10 120
Glycol Ether PMA 10 70
50/50 PM/DPM 10 120
50/50 PM/Propylene

50/50 PM/NMP 10 100


Carbonate 30 Ineffective

Page 2 of 3
Before using a product sold by a company of the LyondellBasell family of companies, users should make their own independent determination that the product is suitable for
the intended use and can be used safely and legally.
SELLER MAKES NO WARRANTY; EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY WARRANTY)
OTHER THAN AS SEPARATELY AGREED TO BY THE PARTIES IN A CONTRACT.

This product(s) may not be used in:


(i) any U.S. FDA Class I, Health Canada Class I, and/or European Union Class I medical devices, without prior notification to Seller for each specific product and application; or
(ii) the manufacture of any of the following, without prior written approval by Seller for each specific product and application: U.S. FDA Class II Medical Devices;
Health Canada Class II or Class III Medical Devices; European Union Class II Medical Devices; film, overwrap and/or product packaging that is considered a
part or component of one of the aforementioned medical devices; packaging in direct contact with a pharmaceutical active ingredient and/or dosage form that is
intended for inhalation, injection, intravenous, nasal, ophthalmic (eye), digestive, or topical (skin) administration; tobacco related products and applications,
electronic cigarettes and similar devices, and pressure pipe or fittings that are considered a part or component of a nuclear reactor. Additionally, the product(s)
may not be used in: (i) U.S. FDA Class III Medical Devices; Health Canada Class IV Medical Devices; European Class III Medical Devices; (ii) applications
involving permanent implantation into the body; (iii) life-sustaining medical applications; and (iv) lead, asbestos or MTBE related applications. All references to
U.S. FDA, Health Canada, and European Union regulations include another country’s equivalent regulatory classification.

Users should review the applicable Safety Data Sheet before handling the product.

Alkylate, Duopac, Duoprime, Filmex, MPDIOL, Polymeg, SAA-100, SAA-101, TBAc, Tebol, T-Hydro, and Tufflo are trademarks owned or used by the LyondellBasell family of
companies.

Duopac, Duoprime, Filmex, MPDIOL, Polymeg, Tebol, T-Hydro and Tufflo are registered in the U.S. Patent and Trademark Office.

Houston, Texas, USA l Tel: +1 713 309 7200 or toll-free within USA +1 888 777 0232
Rotterdam, The Netherlands l Tel: +31 10 275 5500
Hong Kong, China l Tel: +852 2882 2668

© LyondellBasell Industries Holdings, B.V. 2011 www.lyondellbasell.com 2593-V2-0511


Supersedes 2593-V2-0104

Page 3 of 3

Page 3 of 3

You might also like