GYTA53
GYTA53
GYTA53
GYTA53-12/24B1.3
Xcom Ltd
1. Scope
This Specification covers the design requirements and performance standard for the supply of optical fibre
cable in the industry. Xcom ensures a stable quality control system for our cable products through several
programs including ISO 9001, ISO 14001 and OHS.
Cable type Application
GYTA53-12/24B1.3 Direct buried installation
1.2 Reference
The cable offered by Xcom are designed, manufactured and tested according to the standards as follows:
ITU-T G.652 Characteristics of a single-mode optical fibre
IEC 60794-1-1 Optical fibre cables-part 1-1: Generic specification-General
Optical fibre cables-part 1-2: Generic specification-Basic optical cable test
IEC 60794-1-2
procedure
IEC 60794-3 Optical fibre cables-part 3: Sectional specification-Outdoor cables
Optical fibre cables-part 3-10: Outdoor cables-Family specification for duct and
IEC 60794-3-10
direct buried optical communication cables
Optical fibre cables-Part 3-11: Outdoor cables-Detailed specification for duct and
IEC 60794-3-11
directly buried single-mode optical fibre telecommunication cables
2. Optical Fibre
Optical Fibres supplied in this specification meet the requirements of ITU-T G652D
Parameters Specification
MFD(1310nm) 9.2+/-0.4um
MFD(1550nm) 10.4+/-0.5um
Cladding diameter 125µm±1.0µm
Fiber diameter 245+/-7um, with UV coating, and colored to : 250+/-15um
Core/cladding concentricity error ≤ 0.6um
Coating/cladding concentricity error ≤ 12.0um
Cladding non circularity ≤ 1.0%
Cut off wavelength λcc ≤1260nm
1310nm: 0.36dB/km max after cabling
Attenuation coefficient
1550nm: 0.22dB/km max after cabling
Bending-loss performance of optical fiber
≤0.05dB (100 turns around a mandrel of 50mm diameter)
@1310nm&1550nm
Polarization mode dispersion link value ≤0.1ps/√km
Zero-dispersion wavelength 1312+/-12nm
Zero-dispersion slope ≤0.091ps/nm2.km
3. Optical Cable
3.1 Technical Characteristics
The unique second coating and stranding technology provide the fibres with enough space and bending
endurance, which ensure good optical property of the fibres in the cable
Accurate process control ensures good mechanical and temperature performance
High quality raw material guarantees the long service life of cable
GYTA53-24B1.3
Value
Item Contents
12 24
Number 1 2
Loose tube
Outer diameter (mm) 1.8
Filler Number 4 3
Max. fiber counts per tube G.652D 12
Material Steel wire
Central strength member
Diameter (mm) 1.4
Water Blocking Material Material Cable filling
Water barrier Material APL tape
Material MDPE
Inner sheath Color Black
Thickness (mm) Nominal: 0.8
Armor Material Steel tape
Material MDPE
Outer sheath Color Black
Thickness (mm) Nominal: 1.6
Cable diameter(mm) Approx. 11.6
Cable weight(kg/km) Approx. 145
Value
Item
12 24
Tensile performance(N) 2700
Crush(N/100mm) 2200
Operation temperature: -40℃~+70℃
Installation temperature -10℃~+60℃
Storage temperature -40℃~+70℃
IEC 60794-1-2-E6
Repeated Bending radius: 20*D Additional attenuation: ≤0.1dB
bending Cycles: 25 No damage to outer jacket and inner elements
Load: 150N
IEC 60794-1-2-E7
Cycles:10
Additional attenuation: ≤0.1dB
Torsion Length under test: 1m
No damage to outer jacket and inner elements
Turns: ± 90°
Load: 150N
IEC 60794-1-2-F5B
Water Time : 24 hours
No water leakage.
Penetration Sample length : 3m
Water height : 1m
IEC 60794-1-2-F1
Sample length: at least 1000m
Temperature Temperature range: -40℃~+70℃ The change in attenuation coefficient shall be
cycling Cycles: 2 less than 0.1 dB/km
Temperature cycling test dwell time:
12 hours
Other
According to IEC 60794-1
parameters