Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

GYTA53

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Version GYTA53-V1.

Optical Fibre Cable Technical Specification

Direct buried Cable

GYTA53-12/24B1.3

Xcom Ltd

All rights reserved

All Rights Reserved Copyright © 2017


Optical Fibre Cable Technical Specification

1. Scope
This Specification covers the design requirements and performance standard for the supply of optical fibre
cable in the industry. Xcom ensures a stable quality control system for our cable products through several
programs including ISO 9001, ISO 14001 and OHS.
Cable type Application
GYTA53-12/24B1.3 Direct buried installation

1.1 Cable Description


Optical fibres are housed in loose tubes that are made of high-modulus plastic and filled with waterproof
compounds.
Phosphated steel wire is applied as central strength member.
Loose tubes are SZ stranded around the central strength member.
Water blocking compound is used in and over the cable core to prevent it from water ingress.
Inner laminated aluminum tape and po lyethylene sheath are covered over the cable core.
Corrugated steel tape and polyethylene sheath are applied as outer sheath.

1.2 Reference
The cable offered by Xcom are designed, manufactured and tested according to the standards as follows:
ITU-T G.652 Characteristics of a single-mode optical fibre
IEC 60794-1-1 Optical fibre cables-part 1-1: Generic specification-General
Optical fibre cables-part 1-2: Generic specification-Basic optical cable test
IEC 60794-1-2
procedure
IEC 60794-3 Optical fibre cables-part 3: Sectional specification-Outdoor cables
Optical fibre cables-part 3-10: Outdoor cables-Family specification for duct and
IEC 60794-3-10
direct buried optical communication cables
Optical fibre cables-Part 3-11: Outdoor cables-Detailed specification for duct and
IEC 60794-3-11
directly buried single-mode optical fibre telecommunication cables

1.3 Life Time


Optical fibre cables supplied in compliance with this specifications is capable to withstand the typical
service condition for a period of twenty-five (25) years without detriment to the operation characteristics
of the cable.

All Rights Reserved Copyright © 2017


Page: 1 of 6
Optical Fibre Cable Technical Specification

2. Optical Fibre
Optical Fibres supplied in this specification meet the requirements of ITU-T G652D
Parameters Specification
MFD(1310nm) 9.2+/-0.4um
MFD(1550nm) 10.4+/-0.5um
Cladding diameter 125µm±1.0µm
Fiber diameter 245+/-7um, with UV coating, and colored to : 250+/-15um
Core/cladding concentricity error ≤ 0.6um
Coating/cladding concentricity error ≤ 12.0um
Cladding non circularity ≤ 1.0%
Cut off wavelength λcc ≤1260nm
1310nm: 0.36dB/km max after cabling
Attenuation coefficient
1550nm: 0.22dB/km max after cabling
Bending-loss performance of optical fiber
≤0.05dB (100 turns around a mandrel of 50mm diameter)
@1310nm&1550nm
Polarization mode dispersion link value ≤0.1ps/√km
Zero-dispersion wavelength 1312+/-12nm
Zero-dispersion slope ≤0.091ps/nm2.km

All Rights Reserved Copyright © 2017


Page: 2 of 6
Optical Fibre Cable Technical Specification

3. Optical Cable
3.1 Technical Characteristics
 The unique second coating and stranding technology provide the fibres with enough space and bending
endurance, which ensure good optical property of the fibres in the cable
 Accurate process control ensures good mechanical and temperature performance
 High quality raw material guarantees the long service life of cable

3.2 Cross Section of Cable

GYTA53-24B1.3

3.3 Fibre and Loose Tube Identification


The color code of fibres and Loose tube will be identification in accordance with the following color
sequence, other sequence also is available.
1 2 3 4 5 6
Blue Orange Green Brown Grey White
Color Code
7 8 9 10 11 12
Red Black Yellow Violet Pink Aqua

The color of the fillers will be natural.

All Rights Reserved Copyright © 2017


Page: 3 of 6
Optical Fibre Cable Technical Specification

3.4 Dimensions and Descriptions


The standard structure of GYTA53 cable is shown in the following table, other structure and fibre count
are also available according to customer requirements.

Value
Item Contents
12 24
Number 1 2
Loose tube
Outer diameter (mm) 1.8
Filler Number 4 3
Max. fiber counts per tube G.652D 12
Material Steel wire
Central strength member
Diameter (mm) 1.4
Water Blocking Material Material Cable filling
Water barrier Material APL tape
Material MDPE
Inner sheath Color Black
Thickness (mm) Nominal: 0.8
Armor Material Steel tape
Material MDPE
Outer sheath Color Black
Thickness (mm) Nominal: 1.6
Cable diameter(mm) Approx. 11.6
Cable weight(kg/km) Approx. 145

3.5 Main Mechanical and Environmental Performance

Value
Item
12 24
Tensile performance(N) 2700
Crush(N/100mm) 2200
Operation temperature: -40℃~+70℃
Installation temperature -10℃~+60℃
Storage temperature -40℃~+70℃

All Rights Reserved Copyright © 2017


Page: 4 of 6
Optical Fibre Cable Technical Specification

4 Mechanical, Physical and Environmental Test Characteristics


The mechanical and environmental performance of the cable are in accordance with the following table.
Unless otherwise specified, all attenuation measurements required in this section shall be performed at
1550nm.

Items Test Method Requirements


IEC 60794-1-2-E1
Load: According to 3.5 Additional attenuation: ≤0.1dB after test
Tension
Sample length: Not less than 50m. No damage to outer jacket and inner elements
Duration time: 1min.
IEC 60794-1-2-E3
Additional attenuation: ≤0.1dB after test
Crush Load: According to 3.5
No damage to outer jacket and inner elements
Duration of load: 1min
IEC 60794-1-2-E4
Radius: 300 mm
Additional attenuation: ≤0.1dB
Impact Impact energy: 10 J
No damage to outer jacket and inner elements
Impact number: 1
Impact points: 3
IEC 60794-1-2-E11A
Mandrel radius: 10*D Additional attenuation: ≤0.1dB
Bend
Turns:4 No damage to outer jacket and inner elements
Cycles:3

IEC 60794-1-2-E6
Repeated Bending radius: 20*D Additional attenuation: ≤0.1dB
bending Cycles: 25 No damage to outer jacket and inner elements
Load: 150N

IEC 60794-1-2-E7
Cycles:10
Additional attenuation: ≤0.1dB
Torsion Length under test: 1m
No damage to outer jacket and inner elements
Turns: ± 90°
Load: 150N
IEC 60794-1-2-F5B
Water Time : 24 hours
No water leakage.
Penetration Sample length : 3m
Water height : 1m
IEC 60794-1-2-F1
Sample length: at least 1000m
Temperature Temperature range: -40℃~+70℃ The change in attenuation coefficient shall be
cycling Cycles: 2 less than 0.1 dB/km
Temperature cycling test dwell time:
12 hours
Other
According to IEC 60794-1
parameters

All Rights Reserved Copyright © 2017


Page: 5 of 6
Optical Fibre Cable Technical Specification

5 Packaging and Drum


5.1 Cable Sheath Marking

Unless otherwise specified, the cable sheath marking shall be as follows:


Color: white
Contents: Xcom, the year of manufacture, the type of cable, cable number, length marking
Interval: 1±0.2% m
Outer sheath marking legend can be changed according to user’s requests.

5.2 Reel Length


Standard reel length: 2/3 km/reel, other length is also available.

5.3 Cable Drum


The cables are packed in fumigated wooden drums.

5.4 Cable Packing


Both ends of the cable will be sealed with suitable plastic caps to prevent the entry of moisture during
shipping, handling and storage. The inner end is available for testing.

All Rights Reserved Copyright © 2017


Page: 6 of 6