6 Systems
6 Systems
6 Systems
Periodic quality reviews as described in ICH Q7 Section 2.5, Product Quality Review; inspection
audit coverage should include API types that are representative of manufacturing at this site;
inspection audit should also examine some batch and data records associated with each API
quality review to verify that firm’s review was sufficiently complete; and, audit should confirm that
2 firm has identified any trends and has corrected or mitigated sources of unacceptable variation.
Utilities such as steam, gas, compressed air, heating, ventilation, and air conditioning should be
qualified and appropriately monitored (note: this system includes only those utilities whose
output is not intended to be incorporated into the API, such as water used in cooling/heating
18 jacketed vessels).
19 Lighting, sewage and refuse disposal, washing and toilet facilities.
20 Control system for implementing changes in the building.
Sanitation of the building including use of rodenticides, fungicides, insecticides, cleaning and
21 sanitizing agents.
22 Training and qualification of personnel.
Process Equipment
23 Equipment installation, operational, performance qualification where appropriate.
24 Appropriate design, adequate size and suitably located for its intended use.
Equipment surfaces should not be reactive, additive, or absorptive of materials under process so
25 as to alter their quality.
Equipment (e.g., reactors, storage containers) and permanently installed processing lines
26 should be appropriately identified.
Substances associated with the operation of equipment (e.g., lubricants, heating fluids or
coolants) should not come into contact with starting materials, intermediates, final APIs, and
27 containers.
Cleaning procedures and cleaning validation and sanitization studies should be reviewed to
verify that residues, microbial, and, when appropriate, endotoxin contamination are removed to
28 below scientifically appropriate levels.
Calibrations using standards traceable to certified standards, preferably NIST, USP, or
29 counterpart recognized national government standard-setting authority.
S.No Task Yes No NA observations