Relay Output Modules


F2-08TRS Relay Output $182.00 Typical Relay Life (Operations)
Outputs per Module 8 at Room Temperature
Outputs Points Consumed 8 Voltage & Load Current
Commons per Module 8 (isolated) Type of Load 50mA 5A 7A
3, Form C (SPDT) 24VDC Resistive 10M 600K 300K
Output Type 24VDC Solenoid – 150K 75K
5, Form A (SPST normally open)
7A @ 12-28 VDC, 12-250 VAC 110VAC Resistive – 600K 300K
Operating Voltage 110VAC Solenoid – 500K 200K
0.5 A @ 120VDC
220VAC Resistive – 300K 150K
Peak Voltage 150VDC, 265VAC
220VAC Solenoid – 250K 100K
ON Voltage Drop N/A 1) Contact life may be extended beyond those values shown with
AC Frequency 47 to 63 Hz the use of arc suppression techniques described in the DL205 User
Manual. Since these modules have no leakage current, they do not
Minimum Load Current 10mA @ 12VDC have built-in snubber. For example, if you place a diode across a
Max Load Current (resistive) 7A/point 3 (subject to derating) 24VDC inductive load, you can significantly increase the life of the
relay.
Max Leakage Current N/A 2) At 120VDC 0.5 A resistive load, contact life cycle is 200K cycles.
Max Inrush Current 12A 3) Normally closed contacts have 1/2 the current handling
capability of the normally open contacts.
Base Power Required 5VDC 670mA
OFF to ON Response 15ms (typical) D erating C hart

ON to OFF Response 5ms (typical) 8 4A/


Terminal Type (included) Removable; D2-8IOCON pt.
6 5A/pt.
Status Indicator Logic side
Weight 5.5 oz. (156g) N um ber
Points O n 4 6A/
Fuses None pt.
(100% duty
cycle) 2 7A/pt.
See Wiring Solutions for part numbers of
ZIPLink cables and connection modules
0
compatible with this I/O module.
0 10 20 30 40 50 55 °C
32 50 68 86 104 122131°F
Am bientTem perature (°C /°F)

OUT RELAY

0 4
1 5 TypicalC ircuit
12--28VD C
NO 0
L 2 6 (points 1,2,3,4,5)
12--250VAC C1
12--28VD C 3 7 12--28VD C
12--250VAC 12--250VAC
1 InternalC ircuitry
C0
F2-08TRS
NO 1 C om m on
L 12-250VAC
norm ally closed
NC 0 7A 50/60Hz
12--28VD C L 12-28VDC
12--250VAC C2 10mA-7A NO
12--28VD C L
C3 12--250VAC NO0
C1
NO 2 C0
L NO1
NO 3 NC0
L C2
12--28VD C C3
12--250VAC C4
12--28VD C NO2
C5 12--250VAC NO3 TypicalC ircuit
C4 (Points 0,6,& 7 only)
NO 4 C5
L
NO4
NO5 12--28VD C
NO 5 12--250VAC InternalC ircuitry
L
NC6
NC 6 NC7
norm ally closed C6
L C7 C om m on
N C 7 norm ally closed NO6
12--28VD C L NO7
12--250VAC C6
12--28VD C NO
C7 12--250VAC L

NO 6 NC
L L
NO 7
L

www.automationdirect.com DL205 PLCs tDL2-62


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Wiring Solutions
Wiring Solutions using the ZIPLink Wiring System
ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount
connector modules. It’s as simple as plugging in a cable connector at either end or terminating wires at only one end.
Prewired cables keep
installation clean and efficient, using half the space at a fraction of the cost of standard terminal blocks. There are several
wiring
solutions available when using the ZIPLink System ranging from PLC I/O-to-ZIPLink Connector Modules that are ready for
field
termination, options for connecting to third party devices, GS, DuraPulse and SureServo Drives, as well as special relay,
transorb and communications modules. Pre-printed I/O-specific adhesive label strips for quick marking of ZIPLink modules
are provided with ZIPLink cables. See the following solutions to help determine the best ZIPLink system for your application.
Solution 1: Do-more, DirectLOGIC, CLICK
and Productivity Series I/O Modules to
ZIPLink Connector Modules Using the PLC I/O Modules to ZIPLink Connector
When looking for quick and easy I/O-to-field termination, a Modules selector tables located in this section,
ZIPLink connector module used in conjunction with a prewired 1. Locate your I/O module/PLC
ZIPLink
cable, consisting of an I/O terminal block at one end and a multi- 2. Select a ZIPLink Module
pin connector at the other end, is the best solution. 3. Select a corresponding ZIPLink Cable.

Solution 2: Do-more, DirectLOGIC, CLICK


and Productivity Series I/O Modules to
3rd Party Devices Using the I/O Modules to 3rd Party Devices selector
When wanting to connect I/O to another device within proximity tables located in this section,
of the I/O modules, no extra terminal blocks are necessary when 1. Locate your PLC I/O module
using the ZIPLink Pigtail Cables. ZIPLink Pigtail Cables are
prewired to an I/O terminal block with color-coded pigtail with 2. Select a ZIPLink Pigtail Cable that is compatible
soldered-tip wires on the other end. with your 3rd party device.

Solution 3: GS Series and DuraPulse Drives


Communication Cables Using the Drives Communication selector tables
Need to communicate via Modbus RTU to a drive or a located in this section,
network of drives? 1. Locate your Drive and type of communications
ZIPLink cables are available in a wide range of 2. Select a ZIPLink cable and other associated hardware.
configurations for connecting to PLCs and SureServo,
SureStep, Stellar Soft Starter and AC drives. Add a ZIPLink
communications module to quickly and easily set up a
multi-device network.

www.automationdirect.com DL205 PLCs tDL2-45


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Wiring Solutions
Solution 4: Serial Communications Cables
ZIPLink offers communications cables for use with DirectLOGIC, Using the Serial Communications Cables
CLICK, and Productivity CPUs, that can also be used with other selector table located in this section,
communications devices. Connections include a 6-pin RJ12 or 9-pin, 1. Locate your connector type
15-pin and 25-pin D-sub connectors which can be used in conjunction
with the RJ12 or D-Sub feedthrough modules. 2. Select a cable.

Solution 5: Specialty ZIPLink Modules


For additional application solutions, ZIPLink modules are available
in a variety of configurations including stand-alone relays, 24VDC Using the ZIPLink Specialty Modules selector
and 120VAC transorb modules, D-sub, RJ12 and RJ45 feedthrough table located in this section,
modules, communication port adapter and distribution modules, and 1. Locate the type of application
SureServo 50-pin I/O interface connection.
2. Select a ZIPLink module.

Solution 6: ZIPLink Connector Modules to 3rd Party Devices


If you need a way to connect your device to terminal blocks without all
that wiring time, then our pigtail cables with color-coded soldered-tip Using the Universal Connector Modules and
wires are a good solution. Used in conjunction with any compatible Pigtail Cables table located in this section,
ZIPLink Connector Modules, a pigtail cable keeps wiring clean and easy 1. Select module type
and reduces troubleshooting time.
2. Select the number of pins
3. Select cable.

www.automationdirect.com DL205 PLCs tDL2-46


For the latest prices, please check AutomationDirect.com.
1-800-633-0405

PLC I/O Modules to ZIPLink Connector


Modules – Do-more!/DL205
Do-more / DL205 PLC Input Module ZIPLink Selector Do-more/ DL205 PLC Output Module ZIPLink Selector
PLC ZIPLink PLC ZIPLink
# of Output # of
Input Module Component Module Part No. Cable Part No. † Component Module Part No. Cable Part No. †
Terms Module Terms
D2-08ND3 10 Feedthrough ZL-D2-CBL10 * D2-04TD1 ² ZL-D2-CBL10
ZL-RTB20 (-1) D2-08TD1 10 Feedthrough ZL-D2-CBL10-1
Feedthrough ZL-D2-CBL19
D2-16ND3-2 19 ZL-D2-CBL19-1 D2-08TD2 ZL-RTB20 (-1) ZL-D2-CBL10-2
Sensor ZL-LTB16-24-1 ZL-D2-CBL19-2
Feedthrough
D2-16TD1-2
Feedthrough ZL-RTB40 (-1) 180 deg conn: Fuse ZL-RFU20 4
D2-32ND3 ¹ 40 ZL-D24-CBL40
Sensor ZL-LTB32-24-1 ZL-D24-CBL40-1 Feedthrough ZL-RTB20 (-1)
ZL-D24-CBL40-2
Feedthrough ZL-RTB40(-1) 45 deg conn: Fuse ZL-RFU204 ZL-D2-CBL19
ZL-D24-CBL40-X D2-16TD2-2 19 ZL-D2-CBL19-1
D2-32ND3-2 ¹ 40 ZL-RRL16-24-2
Sensor ZL-LTB32-24-1 ZL-D24-CBL40-1X ZL-D2-CBL19-2
ZL-RRL16W-24-2
ZL-D24-CBL40-2X Relay
ZL-RRL16F-24-2
ZL-D2-CBL10 ZL-RRL16HDF-24-2
D2-08NA-1 10
Feedthrough ZL-D2-CBL10-1 F2-16TD1P
D2-08NA-2 10 ZL-RTB20 (-1) ZL-D2-CBL10-2 Feedthrough ZL-RTB20 (-1)
F2-16TD2P
D2-16NA 19 Feedthrough ZL-D2-CBL19 *
Feedthrough ZL-RTB40 (-1) 180 deg conn:
† X in the part number represents a 45° angle. D2-32TD1 ¹ ZL-D24-CBL40
Fuse ZL-RFU40 4 ZL-D24-CBL40-1
Do-more/DL205 PLC Combo In/Out Module ZIPLink Selector ZL-D24-CBL40-2
40
45 deg conn:
PLC ZIPLink Feedthrough ZL-RTB40 (-1) ZL-D24-CBL40-X
Combo # of Module Part D2-32TD2 ¹ ZL-D24-CBL40-1X
Component Cable Part No. ZL-D24-CBL40-2X
Module Terms No. Fuse ZL-RFU40 4
D2-08CDR 10 Feedthrough ZL-RTB20 (-1) ZL-D2-CBL10 * ZL-D2-CBL10
D2-08TA
10 Feedthrough ZL-D2-CBL10-1
Do-more/DL205 PLC Analog Module ZIPLink Selector F2-08TA ZL-RTB20 (-1) ZL-D2-CBL10-2
PLC ZIPLink Feedthrough ZL-D2-CBL19
D2-12TA 19 ZL-D2-CBL19-1
Analog # of
Component Module Cable Fuse ZL-RFU20 4 ZL-D2-CBL19-2
Module Terms
D2-04TRS 2 ZL-D2-CBL10
F2-04AD-1 10 Feedthrough ZL-D2-CBL10-1
F2-08AD-1 D2-08TR ZL-D2-CBL10-2
F2-04AD-2 ZL-D2-CBL10 ZL-RTB20 (-1)
F2-08TRS 2 19 ZL-D2-CBL19 *
ZL-D2-CBL10-1 Feedthrough
F2-08AD-2 ZL-D2-CBL10-2 F2-08TR 3 10 ZL-D2-CBL10 *
F2-02DA-1 Feedthrough ZL-D2-CBL19
F2-02DAS-1 10 D2-12TR 19 ZL-D2-CBL19-1
Fuse ZL-RFU20 4 ZL-D2-CBL19-2
F2-08DA-1 ZL-D2-CBL19
Feedthrough ZL-RTB20 (-1)
ZL-D2-CBL19-1 † X in the part number represents a 45° angle plug
F2-02DA-2 ZL-D2-CBL19-2 * Select the cable length by replacing the * with: Blank = 0.5 m, -1 = 1.0 m,
F2-02DAS-2 ZL-D2-CBL10 or -2 = 2.0 m.
F2-08DA-2 ZL-D2-CBL10-1 1To make a custom cable for the 32-point modules, use: Solder-style 180° connector ZL-D24-
F2-4AD2DA ZL-D2-CBL10-2 CON or Solder-style 45° connector ZL-D24-CON-X
ZL-D2-CBL19 2 Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not
F2-8AD4DA-1
19 ZL-D2-CBL19-1 to exceed module specs 2A per point and 2A per common when used with the
F2-8AD4DA-2 ZL-D2-CBL19-2 ZIPLink wiring system.
F2-04RTD 3 The F2-08TR outputs are derated not to exceed 2A per point and 4A per common when
Matched These modules are not supported by the ZIPLink wiring
Only system
used with the ZIPLink wiring system.
F2-04THM 4 Fuses (5 x 20 mm) are not included. See Edison Electronic Fuse section for (5 x 20 mm)
fuse. S500 and GMA electronic circuit protection for fast-acting maximum protection.
S506 and GMC electronic circuit protection for time-delay performance. Ideal for inductive
circuits.
To ensure proper operation, do not exceed the voltage and current rating of ZIPLink module.
ZL-RFU20 = 2A per circuit; ZL-RFU40 = 400mA per circuit.

Note: ZIPLink Connector Module specifications follow the Com-


patibility Matrix tables. ZIPLink Cables specifications are at the
end of this ZIPLink section.
www.automationdirect.com DL205 PLCs tDL2-47
For the latest prices, please check AutomationDirect.com.
1-800-633-0405

Dimensions and Installation


HERE

Understanding the installation See


requirements for your DL205 system will the Enclosures section
help ensure that the DL205 products for an enclosure that may
operate within their environmental and be suitable for your
electrical limits. application

Plan for safety


This catalog should never be used as a 2"
replacement for the user manual. The 50m m
user manual, D2-USER-M (downloadable m in

online), contains important safety


information that must be followed. The
system installation should comply with all
appropriate electrical codes and standards.
2"
50m m

Environmental
m in

specifications
2"
50m m
m in
The Environmental Specifications table
at the right lists specifications that apply
globally to the DL205 system (CPUs,
bases, and I/O modules). Be sure that
the DL205 system is operated within
these environmental specifications.

Base dimensions
and mounting Environmental Specification
Storage Temperature
Rating
-4°F to 158°F (-20°C to 70°C)
Use the diagrams below to make sure
the DL205 system can be installed in your Ambient Operating Temperature 32°F to 131°F (0°C to 55°C)
application. To ensure proper airflow for Ambient Humidity 30% to 95% relative humidity (non-condensing)
cooling purposes, DL205 bases must be
Vibration Resistance MIL STD 810C, Method 514.2
mounted horizontally. It is important
to check these dimensions against the Shock Resistance MIL STD 810C, Method 516.2
conditions required for your application. Noise Immunity NEMA (ICS3-304)
For example, it is recommended that
approximately 3” of space is left in front Atmosphere No corrosive gases
PLC surface for ease of access and cable
clearances. Also, check the installation Base A B C D
guidelines for recommended cabinet
D2-03B-1, D2-03BDC1-1 6.77” 172mm 6.41” 163mm 5.8” 148mm 7.24” 184mm
clearances.
D2-04B-1, D2-04BDC1-1 7.99” 203mm 7.63” 194mm 7.04” 179mm 8.46” 215mm
D2-06B-1, D2-06BDC1-1, D2-06BDC2-1 10.43” 265mm 10.07” 256mm 9.48” 241mm 10.90” 277mm
D2-09B-1, D2-09BDC1-1, D2-09BDC2-1 14.09” 358mm 13.74” 349mm 13.14” 334mm 14.56” 370mm

A
C
OK

5.85”
With D2-DSCBL-1 on port 2
148mm 3.54” 2.99”
With 32pt. ZipLink cable or 4.45” 90mm 76mm
base expansion unit cable 113mm
3.62”
With 16pt. I/O 92mm
With 8pt. I/O 2.95” B Airflow
75mm
With D2-EM base expansion module

DIN rail slot (35mm)

www.automationdirect.com DL205 PLCs tDL2-23