Lysaght Multiclad
Lysaght Multiclad
Lysaght Multiclad
It is recommended that heavy-duty cut resistant gloves and appropriate manual handling techniques or a lifting plan be used when handling Penang www.bluescopelysaght.com.sg
material. Tel: 604-646 9553/6653
Fax: 604-646 6855
Keep the product dry and clear of the ground. If stacked or bundled product becomes wet, separate it, wipe it with a clean cloth to dry thoroughly. BlueScope LYSAGHT (B) PTE LTD
Johor Bahru industrial complex
Handle materials carefully to avoid damage: don’t drag materials over rough surfaces or each other; don’t drag tools over material; protect from Tel: 607-351 2660/4660 beribi phase 1
swarf. Fax: 607-351 5660 6km, jalan gadong
bandar seri begawan be 1118
Cutting Kuantan brunei darussalam
For cutting thin metal on site, we recommend a circular saw with a metal-cutting blade because it produces fewer damaging hot metal particles and Tel: 609-515 7836/7837 Tel: 673-244 7155 Fax: 673-244 7154
leaves less resultant burr than a carborundum disc. Fax: 609-515 7834
www.bluescopelysaght.com.bn
Cut materials over the ground and not over other materials. KOTA BHARU
Tel: 609-747 5222/6222
Sweep all metallic swarf and other debris from roof areas and gutters at the end of each day and at the completion of the installation. Failure to do Fax: 609-747 4212
coating
so can lead to surface staining when the metal particles rust.
(3 s gust, 10 m height, open country terrain) BlueScope Lysaght (Sarawak) Sdn Bhd
Lot 610, Section 66, Pending Industrial Area
Handbook Equation Jalan Merbau, 93450 Kuching recycling
Level Description for VR V50 V500
Sarawak, Malaysia Structural Solutions roofing & walling Solutions House Framing Solutions
I Strong thunderstorms 70 - 56R -0.1 32 40 Tel: 6082-333 621 termite proof
and monsoon winds Fax: 6082-483 486
II Moderately severe 67 - 41R -0.1 39 45
thunderstorms and www.bluescopelysaght.com.my thermal efficiency
extra-tropical gales
III Severe thunderstorms and 106 - 92R -0.1 44 57 warranty
moderate or weakening
typhoons/tropical cyclones
IV Strong typhoons/ 122 - 104R -0.1 52 66
tropical cyclones
V Very strong typhoons/ 156 - 142R -0.1 60 80
tropical cyclones
Printed : November 2010.
Colours
Clean colorbond® steel is available in a full range contemporary colours suitable for all building projects. Clean colorbond® steel finish Valley fix 5 fasteners adjacent to each rib
provides superior aesthetic qualities, and Clean colorbond® ultra steel finish is intended for severe coastal or industrial environments.
Fasteners
Where insulation is to be installed, you may need to increase the length of the screws given below, depending on the density and thickness of the
insulation. When the screw is properly tightened:
• into metal: there should be at least three threads protruding past the support you are fixing to, but the Shankguard must not reach that support;
• into timber: the screw must penetrate the timber by the same amount that the recommended screw would do if there were no insulation.
PHYSICAL PROPERTIES OF LYSAGHT® multiclad™
Steel Grade (MPa) G550 (550MPa minimum yield stress) lysaght® multicladTM : Limit state wind pressure capacities (kPa)
Effective Width of Coverage 1100mm
lysaght® multicladTM 0.42mm BMT / 0.47mm TCT
Depth of Rib 12mm For roofs (c/c) Span (mm)
Base Metal Thickness 0.42mm Span Fasteners 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
LYSAGHT MULTICLAD now has a wider span, which makes it easier and even more economical to install. It
® TM 1110 mm