DMLEU Iom1
DMLEU Iom1
DMLEU Iom1
Model DMLU
Industrial
Commercial
S u b m e r s i b l e Wa s t e w a t e r P u m p
EBARA International Corporation Standard Pump Division
DMLU
Instruction, Operation, and Maintenance
Project:
Contents Model: Chk’d: Date:
Section Page
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Delivery Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Disassembly and Reassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Warnings in this manual provide information for safe use of your EBARA pump, and instructions for preventing injury to those
operating it. Please pay close attention to the instructions listed below. If there are any questions regarding these instructions,
please direct them to EBARA INTERNATIONAL CORPORATION.
1. Before lifting the pump, confirm the total weight of the unit listed in the catalog or outline drawing. Use the appropriate
hoist or crane assembly, and make sure that the load is balanced to prevent shifting during loading and off-loading.
2. Be sure to keep the pump from lying on the power and control cables, and do not use the power and control cables
to lift the pump. This can result in damage to the cables and can cause electrical shorts that can possibly lead to
fires.
3. A qualified electrician should perform all wiring and all national and local electrical codes must be observed.
4. Make sure that all equipment is properly grounded. Failure to do so can result in electric shock.
5. Disassembly and repair of the pump should only be performed by factory trained service centers. Errors made by
unqualified personnel can result in improper assembly and operation, therefore resulting in possible injury.
6. Always make sure that power switch is in OFF position and that power cable is disconnected before inspecting or
repairing the pump.
7. If pump is to be out of service for a long period of time, turn power off. If power is left on without operating pump it
can cause insulation breakdown, resulting in a possible motor short or electric shock.
9. Do not operate the pump unsubmerged, as overheating can occur, causing insulation breakdown and possible
electric shock.
10. If the insulation resistance is below 1MΩ, turn power off to unit as soon as possible, as electric shock can occur.
2. Nameplate
a.) The basic specifications of the pump are listed on the nameplate. Read the pump nameplate to confirm
that the pump you received matches the specifications that you ordered.
Specifications
Item Specifications
Liquid handled Type Waste water
Temperature 0 - 40° C
Solids Capacity Discharge size (in.) 3, 4, 6
Solid size (in.) 3
Materials Impeller Cast iron
Phase Three Phase
Hz 60 Hz
Motor Voltage 230 or 460 VAC
Starting Method 2.2kW : Direct start
3.7 ~ 22kW : Star-Delta start
Protector 2.2kW : Auto-cut
3.7 ~ 22kW : Thermal Protector
Mechanical Seal Lubricants Turbine oil ISO VG32
Maximum water depth 26 ft.
Installation with Quick Discharge Connector or Floor mounted
Motor Size
(HP) 3 5 7.5 10 15 20 30
Figure 2
3. Electrical Wiring:
Note: All electrical wiring should be performed by a qualified electrician, and in accordance with all national
and local electrical codes. Incorrect wiring can result in serious injury.
Figure 3
a.) Wiring should be performed as indicated in Figure 3.
b.) Do not allow the end of the cables to become immersed in water.
c.) Make sure pump is properly grounded using the green ground wire in the power cable. Do not connect the
green wire to the power supply.
EBARA International Corporation
Standard Pump Division 4
(t) 803 327 5005 • (f) 803 327 5097 • info@pumpsebara.com
DMLU
Installation (continued)
Project: d.) Motor protection: Model: Chk’d: Date:
• For 3HP motors, a built-in auto-cut is used and will be activated when motor becomes overheated due to
abnormal conditions such as locked rotor or single phasing. There is no external wiring for this feature.
• For 5HP to 30HP motors, a normally closed built-in thermal protector is used. When motor winding becomes
over-heated, the circuit is opened, shutting the motor down and allowing it to cool. An external sensor cable
is provided for this feature and must be connected to a thermal relay in the control panel. Failure to do so
will void the warranty. Specifications for the thermal protector are listed below:
Operation
1. After completing installation, measure the insulation resistance again, using the procedure described in the
“Installation” section.
2. Check to make sure there is an adequate amount of water in the wet well. Continuous operation of the pump in a
dry condition will cause the motor protector to be activated.
3. Check the direction of rotation by turning on pump. If the discharge volume is low or unusual sounds are heard, it is
likely that rotation has been reversed. If this happens, reverse two of the three power cable wires. (see Figure 4)
Figure 4
4. After confirming that the direction of rotation is correct, gradually open the discharge valve and allow the pump to run
in continuous operation. Check the voltage, current and discharge pressure to make sure they are within allowable limits.
5. If voltage, current and discharge pressure are acceptable, you may continue to operate the pump on a continuous
basis. Please refer to “Troubleshooting” section of the manual or contact your local EBARA distributor if one of these
items is outside of allowable limits.
6. Do not allow the motor to start more than 20 times per hour.
Warning
Always turn the power OFF before inspecting and repair the pump. Failure to do so can result in serious injury.
Mechanical seal
(mm) 30 40 45
Lubricating oil (oz)
Turbine oil ISO VG32 38 58 102
Figure 5
Figure 6
4. Extended storage:
a.) Keep pump in a dry environment, out of direct sunlight.
b.) Every 30 days, check the insulation resistance and rotate the impeller by hand to prevent rotating parts from
seizing together.
Motor won’t turn. (1) Foreign matter hinders level control float from functioning (1) Remove foreign matter
Starts, but immediately properly.
stops. (2) Power failure. (2 - 3) Contact electric power company for remedy
(3) Large voltage unbalance.
(4) Significant drop in voltage (4) Check power supply
(5) There is an open phase (5) Check power supply; Inspect starter and connections
(6) Faulty circuit connection (6) Correct wiring
(7) Blown fuse (7) Replace with correct size fuse
(8) Faulty starter (8) Replace with correct starter
(9) Defective float (9) Repair or replace float
(10) Malfunctioning circuit breaker (10) Repair location of circuit
(11) Foreign matter clogging pump (11) Remove clog from pump
(12) Motor is shorted out (12) Repair or replace
(13) Motor bearings are frozen (13) Repair or replace
Operates, but stops after (1) Prolonged dry operation has activated motor protector (1) Raise the off float level
a while.Thermal protector and caused pump to stop
is activated. (2) High liquid temperature has activated motor protector (2) Lower liquid temperature
and caused pump to stop
Overcurrent (1) Large discrepancy between power source and voltage (1) Contact power company for remedy
(2) Significant voltage drop (2) Contact power company for remedy
(3) There is an open phase (3) Check power supply
Inspect starter & electrical connections
(4) Reverse rotation (4) Check rotation
(5) Low head; pumping too much liquid (5) Adjust discharge valve to desired flow
(6) Foreign matter clogging pump (6) Remove clog from the pump
(7) Motor bearing is worn or damaged (7) Repair or replace
2. Reassembly:
a.) Perform the above instructions in reverse order, replacing the o-ring, seal washer and gasket.
Note 1: After reassembly to the point of installing impeller on the shaft, turn the impeller by hand to make sure that it
rotates smoothly.
Note 2: It is recommended to use a screw adhesive (LOCKTITE 271) on the impeller bolt (275) during reassembly.
Note 3: After installing casing back onto pump, turn the impeller by hand through the pump suction to make sure that it
rotates smoothly without rubbing against the wear ring.
Ebara International Corporation, Rock Hill, SC (“EIC-RH”) warrants to the original purchaser only (“Customer”) that the
EIC-RH Commercial Pump/Product (“Pump”) will be free of defects in workmanship and material for a period of twelve (12)
months from the date of installation or eighteen (18) months from the date of shipment by EIC-RH, whichever comes first,
provided that notification of any such defect is promptly given in writing to EIC-RH. Customer may be required at EIC-RH’s
request to verify that it is the Customer of the Pump and that the Pump was installed and operated in accordance with
EIC-RH’s instructions.
EIC-RH’s sole obligation under this warranty will be to repair or replace with a new or reconditioned Pump, such Pump as
has failed or has been found to be defective during the warranty period, or at EIC-RH’s sole option, to refund to the customer
an equitable part of the purchase price. In no event shall EIC-RH’s cost responsibility exceed the initial purchase price paid
by the Customer for the Pump.
EIC-RH shall be liable only for the cost of the Pump, or the cost of repair or replacement of any defective Pump. Customer
shall be responsible for labor, cost of removal and installation at Customer’s premises, transportation and insurance costs to
EIC-RH and any other incidental costs.
This warranty is void and does not apply if pump control cable is not properly connected to control panel, if damage is
caused by improper installation, improper maintenance, accident, alteration, abuse, misuse or if the Pump has been
disassembled prior to warranty evaluation without written authorization from EIC-RH.
Warranty service and information for return procedures will be provided by EIC-RH upon receipt of written notice describing
the defect or problem to:
THE FOREGOING WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY ON THIS PUMP, AND ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE DISCLAIMED AND EXCLUDED FROM THE TERMS OF THIS WARRANTY. EIC-RH’S
SOLE OBLIGATION IN CASE OF ANY DEFECT WILL BE TO PROVIDE THE WARRANTY SERVICE SPECIFIED ABOVE.
THE FOREGOING IS CUSTOMER’S SOLE AND EXCLUSIVE REMEDY, WHETHER IN CONTRACT, TORT OR OTHERWISE
AND EIC-RH SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND
WHATSOEVER.