3DRE(E)(A), Z3DRE(E)(A)
Proportional pressure reducing valve with integrated digital
electronics
RE29283-FK/03.23, Edition 01
Copyright
© Bosch Rexroth AG Bosch Rexroth AG© 2023
All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well
as in the event of applications for industrial property rights.
Liability
The specified data is intended for product description purposes only and shall not be deemed to be
a guaranteed characteristic unless expressly stipulated in the contract. All rights are reserved with
respect to the content of this documentation and the availability of the product.
d0cfe1d8a421f8200a347e8247321ac4, 1, en_US
3DRE(E)(A), Z3DRE(E)(A) 3 / 112
Table of contents
1 About this documentation 12
1.1 Validity of the documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.2 Required and amending documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.3 Representation of information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 Safety instructions 13
2.1 General information on this chapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table of contents
2.3 Improper use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.4 Qualification of personnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.5 General safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.6 Personal protective equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.7 Obligations of the machine end-user. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Overview of the pilot-controlled proportional pressure reducing valves
(Z)3DRE(E,A) 16
3.1 General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2 Valve types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.1 (Z)3DREE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.2 (Z)3DREA with external pressure sensor. . . . . . . . . . . . . . . . . . . . . 17
3.2.3 (Z)3DREA with integrated pressure sensor. . . . . . . . . . . . . . . . . . . . 19
3.3 Optional Bluetooth® dongle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4 "easy2connect" smartphone app. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4 Analog interface – connector XH1 22
4.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.2 Pressure command value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2.1 Functional description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.2.2 Relevant parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.2.3 Setting via "easy2connect". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.3 Actual pressure value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.3.1 Functional description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.3.2 Relevant parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.3.3 Setting via "easy2connect". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table of contents
8.5 Solenoid current controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
8.5.1 Functional description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
8.5.2 Relevant parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
8.5.3 Setting via "easy2connect". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
9 Parameter descriptions 70
9.1 P-0-0115 - Valve status word. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
9.1.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
9.1.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
9.2 P-0-0116 - Valve control word. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
9.2.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
9.2.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
9.3 P-0-0120 - Force mode, control word. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.3.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.3.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.4 P-0-0190 - Valve electronics operating hours. . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.4.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.4.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
9.5 P-0-0670.0.3 - Command: Load factory default values. . . . . . . . . . . . . . . . . . 74
9.5.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.5.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.6 P-0-1520 - Valve electronics type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.6.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.6.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.7 P-0-1910.0.1 - IO-Link: Pressure valve control word. . . . . . . . . . . . . . . . . . . . 74
9.7.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
9.7.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Table of contents
9.21.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
9.22 P-0-2890.0.3 - pressure controller: Slider (controller behavior). . . . . . . . . . 85
9.22.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
9.22.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
9.23 P-0-2890.0.4 - pressure controller: Control word. . . . . . . . . . . . . . . . . . . . . . 85
9.23.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
9.23.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
9.24 P-0-2890.0.5 - Pressure command value preparation: Gain. . . . . . . . . . . . . . 86
9.24.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
9.24.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
9.25 P-0-2890.0.6 - Solenoid current: Offset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
9.25.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
9.25.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
9.26 P-0-2890.0.7 - Solenoid current: P-gain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
9.26.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
9.26.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
9.27 P-0-2890.0.8 - Solenoid current controller: Dither frequency factor. . . . . . . 87
9.27.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
9.27.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
9.28 P-0-2890.0.9 - Actual pressure value: Filter frequency. . . . . . . . . . . . . . . . . . 88
9.28.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
9.28.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
9.29 P-0-2890.0.10 - pressure controller: Nozzle diameter flow rate. . . . . . . . . . . 88
9.29.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
9.29.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Table of contents
9.43.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
9.44 P-0-2900.1.10 - Analog command value input: Value range, lower limit. . . . 95
9.44.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
9.44.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
9.45 P-0-2900.1.11 - Analog command value input: Value range, upper limit. . . . 95
9.45.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
9.45.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
9.46 P-0-2900.2.1 Analog actual pressure value input: Control word. . . . . . . . . . 96
9.46.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
9.46.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
9.47 P-0-2900.2.8 Analog actual pressure value input: Signal range, lower limit. 97
9.47.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
9.47.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
9.48 P-0-2900.2.9 - Analog actual pressure value input: Signal range, upper limit 97
9.48.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
9.48.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
9.49 P-0-2900.2.10 - Analog actual pressure value input: Value range, lower limit 98
9.49.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
9.49.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
9.50 P-0-2900.2.11 - Analog actual pressure value input: Value range, upper
limit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
9.50.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
9.50.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
9.51 P-0-2907.1.1 - Analog command value input: Actual value. . . . . . . . . . . . . . . 99
9.51.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
9.51.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.52 P-0-2907.2.1 - Analog actual pressure value input: Actual value. . . . . . . . . . 100
9.52.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.52.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.53 P-0-2908.1.1 - Analog actual value output: Actual value. . . . . . . . . . . . . . . . . 100
9.53.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.53.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
9.54 P-0-2908.1.2 - Analog actual value output: Control word. . . . . . . . . . . . . . . . 101
9.54.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.54.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.55 P-0-2915.0.3 - Actual current value: Solenoid A. . . . . . . . . . . . . . . . . . . . . . . 101
9.55.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.55.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
9.56 P-0-4028 - Valve: Control word. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.56.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.56.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.57 P-0-4073 - IO link: Diagnosis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.57.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
9.57.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
9.58 P-0-4085 - Force mode: Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
9.58.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
9.58.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
9.59 S-0-0017 - List of all valve parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.59.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.59.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.60 S-0-0030 - Firmware version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.60.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.60.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.61 S-0-0140 - Valve designation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.61.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.61.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
9.62 S-0-0192 - List of all configuration parameters. . . . . . . . . . . . . . . . . . . . . . . . 105
9.62.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
9.62.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Table of contents
9.65.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.66 S-0-0800 - Pressure command value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.66.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.66.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.67 S-0-0809 - Actual pressure value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.67.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.67.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
9.68 S-0-0814 - Tank pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
9.68.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
9.68.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
9.69 S-0-0827 - Pressure control deviation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
9.69.1 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
9.69.2 IO-Link mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
10 Appendix 107
10.1 List of addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Index 109
Trademark
Symbol Meaning
Bluetooth® is a registered trademark of Bluetooth SIG, Inc.
Safety instructions
The safety instructions in the present application documentation contain certain signal words (danger,
warning, caution, notice) and, if applicable, a signal graphic (according to ANSI Z535.6-2011)
The signal word is intended to draw attention to the safety instructions and denotes the severity of the
hazard.
The signal graphic (warning triangle with exclamation mark), which precedes the signal words danger,
warning and caution, indicates hazards for persons.
DANGER In the case of non-compliance with these safety instructions, death or severe
injury will occur.
WARNING In the case of non-compliance with these safety instructions, death or severe
injury may occur.
CAUTION In the case of non-compliance with these safety instructions, minor or mod-
erate injury may occur.
NOTICE In the case of non-compliance with these safety instructions, damage to
property may occur.
Designations
The following designations are used in this documentation:
Designation Meaning
VT-ZBT-1-1X Bluetooth® dongle
2 Safety instructions
2.1 General information on this chapter
The product has been manufactured according to the generally accepted codes of practice. However,
there is still the danger of personal injury and damage to property if you do not observe this chapter and
the safety instructions in this documentation.
• Read this documentation completely and thoroughly before working with the product.
• Keep this documentation in a location where it is accessible to all users at all times.
• Always include the required documentation when passing the product on to third parties.
Safety instructions
• Comply with the technical data and environmental conditions specified in the product documenta-
tion.
• The installation or use of inappropriate products in safety-relevant applications could result in unin-
tended operating states which in turn could cause personal injuries and/or damage to property.
Therefore, only use a product for safety-relevant applications if this use is expressly specified
and permitted in the documentation of the product, e.g. in explosion protection zones or in
safety-related parts of control systems (functional safety).
• Do not commission the product until you can be sure that the end product (for example a machine
or system) where the Bosch Rexroth products are installed complies with the country-specific
provisions, safety regulations and standards of the application.
IT security
The operation of installations, systems and machines basically requires the implementation of a holistic
IT security concept which is state-of-the-art in terms of technology. Accordingly, Bosch Rexroth prod-
ucts and their properties have to be considered as components of installations, systems and machines
for their holistic IT security concept. Unless otherwise documented, Bosch Rexroth products are
designed for operation in local, physically and logically secured networks with access restrictions for
authorized persons, and they are not classified according to IEC 62443-4-2.
3.2.1 (Z)3DREE
The following shows the set-up and function of the valve type (Z)3DREE:
Solenoid
Fig. 1: Overview_(Z)3DREE
On the proportional solenoid, there is the digital on-board electronics (OBED). This is equipped with
one of the following electrical interfaces, via which the command and actual values are exchanged
digitally or analogously with a higher-level control:
• Digital interface L1, IO-Link (connector XH5)
• Analog interface (connector XH1)
– Interface "A1", (command value and actual value 0 ... 10 V)
– Interface "F1", (command value and actual value 4 ... 20 mA)
The pressure command value obtained from the higher-level control is converted in the on-board
electronics into a current command value corresponding to the pressure. This current command value
is preset and regulated as a control value for the proportional solenoid. The predetermined pressure
command value is thus set as the actual pressure value.
External pressure
sensor connection
via interface X2N
Solenoid
Fig. 2: Overview_(Z)3DREA
On the proportional solenoid, there is the digital on-board electronics (OBED). This is equipped with
one of the following electrical interfaces, via which the command and actual values are exchanged
digitally or analogously with a higher-level control:
• Digital interface L1, IO-Link (connector XH5)
• Analog interface (connector XH1)
– Interface "A1", (command value and actual value 0 ... 10 V)
– Interface "F1", (command value and actual value 4 ... 20 mA)
The pressure command value obtained from the higher-level control is regulated in the on-board
electronics. The actual pressure value is detected via an external pressure sensor connected to the
interface X2N.
The type HM 20-2X/400-H-C19-0,16-N (R901518764) is recommended as external pressure sensor.
This pressure sensor is factory set.
Integrated
Solenoid
pressure sensor
Smartphone app
easy2connect
Optional
Bluetooth® dongle
Fig. 4: Overview_BluetoothDongle
With the "easy2connect" smartphone app, a connection via Bluetooth® to the valve can be established
via the Bluetooth® dongle. Further information on the "easy2connect" smartphone app can be found in
the following chapter.
The Bluetooth® dongle also has an integrated diagnostic LED. The current state of the valve and the
dongle are displayed via different colors and different flashing codes of the diagnostic LED.
Integrated
The connection to
the valve is
via Bluetooth®
Fig. 6: easy2connect_Connection
The following functionalities are available in the "easy2connect" smartphone app:
• Electronic valve name plate
• Status and diagnosis of the valve
• Force mode, command value presetting via the app
Actual pressure
value / actual
current value
(Solenoid)
Pressure command
value
Analog interface
connector XH1
Version A1 and F1
The analog interface of the connector is set ex works, corresponding to the selected order option of the
valve, in version A1 or F1.
• Version A1
In version A1, the pressure command value and the actual pressure value or actual current value
are mapped to a voltage range of 0 to 10 V.
• Version F1
In version F1, the pressure command value and the actual pressure value or actual current value are
mapped to a current range of 4 to 20 mA.
Analog input
Analog interface actual value
connector XH1
[bar]
Conversion:
analog command value in
pressure command value 0 bar
Cable break
3.3 mA … 3.6 mA Signal error Set
Overload detected error bit
> 30 mA
Type of signal
The type of signal is used to set whether the analog command value of the connector XH1 is predeter-
mined as a voltage signal in the range from 0 to 10 V or as a current signal in the current range from 4 to
20 mA.
Activation bit
The mapping of the voltage or current signal of the analog command value input to the corresponding
pressure command value is activated via the activation bit.
Analog command
y1
Value range, lower limit value input
x1 x2
[V], [mA]
Value range ( y2 - y1 )
Pressure command value (bar ) = ´ (( Command value input ( V or . mA ) - x1) + y 1
Signal range ( x2 - x1 )
Version A1
When the pressure valve is delivered ex works in version A1, the valve is parameterized so that the
voltage signal range 0 ... 10 V is mapped to a pressure command value range of 0 ... nominal pressure
(in bar) at the analog command value input.
Analog command
y1
0 bar value input
x1 x2
[V]
0V 10 V
200bar
Pressure command value (bar ) = ´ (1V - 0V ) + 0bar = 20bar
10V
Version F1
When the valve is delivered ex works in version F1, the valve is parameterized so that the current signal
range 4 ... 20 mA is mapped to a pressure command value range of 0 ... nominal pressure (in bar) at the
analog command value input.
Analog command
y1
0 bar value input
x1 x2
[mA]
4 mA 20 mA
200bar
Pressure command value (bar ) = ´ (12mA - 4mA) + 0bar = 100bar
16mA
Analog
interface
[V], [mA]
connector XH1
0V
Analog actual value
0 mA Voltage
Actual
pressure x
value
Active Current
Type of signal
[bar]
Actual pressure value
Conversion:
Actual pressure value -> analog actual value
Type of signal
The type of signal is used to set whether the actual pressure value of the connector XH1 is to be output
as a voltage signal in the range from 0 to 10 V or as a current signal in the current range from 4 to 20 mA
as an analog signal.
Activation bit
The output of the actual pressure value to the analog actual value output is activated via the activation
bit.
Signal range
Actual value output (V or . mA) = ´ Actual pressure value (bar ) + Offset (Signal range)
Nominal pressure
Version A1
When the pressure valve is delivered ex works in version A1, the pressure valve is parameterized such
that the actual pressure value is mapped in a range of 0 ... nominal pressure (in bar) to a signal range of
0 ... 10 V at the analog actual value output.
Signal range 0 … 10 V
10V
Actual value output (V ) = ´ 40bar + 0V = 2V
200bar
Version F1
When the pressure valve is delivered ex works in version F1, the pressure valve is parameterized such
that the actual pressure value is mapped in a range of 0 ... nominal pressure (in bar) to a signal range of
4 ... 20 mA at the analog actual value output.
Signal range 4 … 20 mA = 16 mA
16mA
Actual value output ( mA) = ´ 40bar + 4mA = 7,2mA
200bar
⮫ Chapter 9.54 “P-0-2908.1.2 - Analog actual value output: Control word” on page 101
Analog output
actual value
Analog interface
connector XH1
[V], [mA]
Analog actual value
Voltage
Solenoid
current
Current
Active Type of signal
[mA]
Solenoid current
Conversion:
Solenoid current -> analog actual value
Type of signal
The type of signal is used to set whether the solenoid current on the connector XH1 is to be output as an
analog voltage signal in the range from 0 to 10 V or as an analog current signal in the current range from
4 to 20 mA.
Activation bit
The output of the solenoid current to the analog actual value output is activated via the activation bit.
Signal range
Actual value output (V or . mA ) = ´ Solenoid current ( mA ) + Offset ( Signal range )
2000 mA
Version A1
When the pressure valve is delivered ex works in version A1, the pressure valve is parameterized such
that the solenoid current is mapped in a range of 0 ... 2000 mA to a signal range of 0 ... 10 V at the
analog actual value output.
Signal range 0 … 10 V
Solenoid current
[mA]
0 mA 2000 mA
10V
Actual value output (V ) = ´ 500mA + 0V = 2,5V
2000mA
Version F1
When the pressure valve is delivered ex works in version F1, the pressure valve is parameterized such
that the solenoid current is mapped in a range of 0 ... 2000 mA to a signal range of 4 ... 20 mA at the
analog actual value output.
Signal range 4 … 20 mA = 16 mA
16mA
Actual value output (mA) = ´ 500mA + 4mA = 8mA
2000mA
IO-Link-Master
MSB LSB
31 16 15 0
Force mode
Reserved
Feedback value
Reserved
Reserved
Error
Warning
Name Description Valve in operation
Data type
Bit Bit
Value range / comment
offset lenght
Reserved -- -- 30 2
Nominal pressure of the valve
Feedback value Actual pressure value IntegerT 16 14 in bar, factor 0,1
Example: 200 bar -> 0 to 2000
1: Valve ready for operation
Ready for operation BooleanT 15 1
0: Valve not ready for operation
1: Valve control is active Command values are processed
Valve in operation BooleanT 14 1
0: Valve control is not active cylically.
1: Error occured in the valve
Error BooleanT 13 1
0: Nor error in the valve
1: Warning occured in the valve
Warning BooleanT 12 1 For future use.
0: No warning in the valve
Reserved -- -- 10 2
1: Force-Mode aktiv
Force mode BooleanT 9 1
0: Force-Mode nicht aktiv
Closed-loop Closed-loop pressure control can
1: Closed-loop pressure control active
pressure control BooleanT 8 1 only be activated for valves with
0: Open-loop pressure control active
active pressure sensor.
Reserved -- -- 4 4
Command value 1: Pressure command value reached
BooleanT 3 1
reached 0: Pressure command value not reached
Reserved -- -- 2 1
0: Parameter set 0
Active parameter 1: Parameter set 1
Number of the active parameter set UIntegerT 0 2
set 2: Parameter set 2
3: Parameter set 3
IO-Link-Master
Command value
Reserved
Reserved
Reset error
Reserved
5.2 Backup/Restore
IO-Link has a data storage function that makes it easy to swap a device. In this case, certain objects
of the device are linked to the data storage mechanism and these are stored within the IO-Link master
used.
Up to 2048 bytes of object data can be stored per device in the IO-Link master. A checksum is formed
over all objects in order to be able to detect changes in the device. In the event of a change, all data
storage objects can be automatically reloaded into the device during the IO-Link start-up depending on
the configuration in the IO-Link master.
If objects in the device are modified manually, for example, via a Bluetooth connection, a command for
updating the data storage objects can be sent to the IO-Link master (data storage upload request). If
the master receives this command, the master can read and save again all objects linked to the data
storage mechanism, if configured appropriately.
If the user wants to trigger a data storage backup themselves, the command can also be trig-
gered by the IO-Link master (system command "ParamDownloadStore"). The command parameter
"P-0-1910.0.3, Data storage upload request" can be used to start the command via the Bluetooth
connection. If this value is set to "0x3", a data storage backup is requested in the IO-Link device.
As soon as the master has performed the data storage backup, the command parameter is reset to
the value "0". The list of objects associated with the data storage mechanism can be read from the
IO-Link master during the start-up via "Index 0x0003, Subindex 0x05, Index_List" in the device. The
checksum of the data storage objects can be read from the device via "Index 0x0003, Subindex 0x04,
Parameter_Checksum".
Integrated
pressure sensor Analog input
actual pressure
[bar]
Conversion:
External analog actual pressure value
in actual pressure value (bar) 0 bar
pressure sensor Cable break
0.04 V ... 0.07 V
X2N 3.3 mA … 3.6 mA
Signal error Pressure
Overload
> 30 mA
detected controller off
Set
error bit
Type of signal
The type of signal is used to set whether the analog actual pressure value is detected as a voltage signal
in the range from 0 to 10 V or as a current signal in the current range from 4 to 20 mA.
Activation bit
The conversion of the voltage or current signal of the analog actual pressure value into V or mA into the
corresponding actual pressure value in bar is activated via the activation bit.
Conversion of the analog actual pressure value (V or mA) into an actual pressure value (bar)
In the following, it is shown in detail how the conversion of the voltage or current signal of the analog
actual pressure value into V or mA into the corresponding actual pressure value into bar takes place in
principle.
y2
Value range, upper limit
Analog
y1
Value range, lower limit Actual pressure value
x1 x2
[V], [mA]
If a cable break or overload has been detected, as an error reaction, the actual pressure value is set
to the value 0 bar and the pressure controller is switched off. Thus, the valve automatically changes
to open-loop pressure control mode. Furthermore, the error bit is set in accordance with the detected
signal error. As soon as the error case is no longer active, the actual pressure value is automatically
Sensor screen
Parameter set
Filtered solenoid
actual current
value
Parameter set
The pressure valve is supplied with 4 parameter sets, so that the settings for the command value
preparation can be easily adapted to the application of the pressure valve.
Parameter set number Application of the pressure valve
0 Small dead volume
1 Large dead volume
2 User-defined 1 (with small dead volume pre-parameterized ex works)
3 User-defined 2 (with large dead volume pre-parameterized ex works)
In the case of the pressure valve with digital IO-Link interface, the active parameter set is preset
cyclically via the process data (PDout).
In the case of the pressure valve with an analog A1 or F1 interface, the parameter set 1 "Large dead
volume" is set ex works. This can be reconfigured via the "easy2connect" smartphone app.
For application-specific adaptation, it is intended to use parameter sets 2 and 3 first.
Valve on
The output of the control value of the solenoid current controller on the solenoid is only effected when
the "valve on" bit is set. By setting this bit, the output stage of the valve is activated, via which the
solenoid is actuated with the corresponding control value.
In the case of the pressure valve with digital IO-Link interface, the "valve on" bit is cyclically predeter-
mined via the process data (PDout). This means that the bit must be set via IO-Link in order to activate
the output of the control value of the solenoid current controller on the magnet.
In the case of the pressure valve with an analog A1 or F1 interface, the "valve on" bit is set ex works,
so that after the pressure valve is switched on, the output of the control value of the solenoid current
controller to the solenoid takes place immediately.
Controller screen
Parameter set
Parameter set
The pressure valve is supplied with 4 parameter sets, so that the settings for the pressure command
value preparation (-> command value ramp and command value filtering) can be easily adapted to the
application of the pressure valve.
Controller screen
Closed-loop pressure
control on Solenoid current controller
PI controller with feedforward control
Pressure command
value preparation
+ Solenoid
+ - + control value
Pressure controller
Pressure/current curve Factor Dither
Pressure controller frequency
control value factor
Offset
Pressure/current curve
The pressure command value transferred to the solenoid current controller is converted into the
corresponding solenoid current command value via the pressure/current characteristic.
• The dither has as little influence as possible on the amplitude of the actual pressure value.
• A corresponding dynamic of the valve is achieved.
The dither frequency can be adjusted via the factor in such a way that the pressure valve is optimized in
response to one of the conditions:
• Increasing the dynamics of the valve by a smaller dither frequency (→ factor < 1), which results in
a higher pressure amplitude.
• Reduction of the actual pressure value amplitude (→ factor > 1), which results in a worse dynamic
Controller screen
Closed-loop pressure
Parameter set control on
Valve on
Digital
Interface
Pressure command
value preparation
Pressure
command value
Effective pressure
Interface
Pressure controller
A1 / F1
Actual pressure
Internal or value filtration Pressure controller
control value
Actual pressure
external value
pressure sensor Filtered actual
pressure value
Pressure sensor
cable break
Solenoid current
controller
Solenoid
Control value
Filtration Solenoid actual
current value
Filtered solenoid
actual current
value
Pressure controller
The pressure controller is realized as a PI controller with active damping and feedforward control. The
pressure controller can be easily set by using a slider.
The pressure controller calculates the corresponding control value from the effective pressure com-
mand value predetermined by the command value preparation and the actual pressure value currently
detected. When the closed-loop pressure control is activated, this control value is supplied to the
solenoid current controller. The settings of the pressure controller are parameter set dependent. This
means that the settings are used depending on the active parameter set.
Detailed information about the pressure controller can be found in ⮫ Chapter 8.4 “Closed-loop
pressure control” on page 63.
Parameter set
The pressure valve is supplied with 4 parameter sets, so that the settings for the command value
preparation can be easily adapted to the application of the pressure valve.
Parameter set number Application of the pressure valve
0 Small dead volume
1 Large dead volume
2 User-defined 1 (with small dead volume pre-parameterized ex works)
3 User-defined 2 (with large dead volume pre-parameterized ex works)
In the case of the pressure valve with digital IO-Link interface, the active parameter set is preset
cyclically via the process data (PDout).
In the case of the pressure valve with an analog A1 or F1 interface, the parameter set 1 "Small dead
volume" is set ex works. This can be reconfigured via the "easy2connect" smartphone app.
For application-specific adaptation, it is intended to use parameter sets 2 and 3 first.
Valve on
The output of the control value of the solenoid current controller on the solenoid is only effected when
the "valve on" bit is set. By setting this bit, the output stage of the valve is activated, via which the
solenoid is actuated with the corresponding control value.
In the case of the pressure valve with digital IO-Link interface, the "valve on" bit is cyclically predeter-
mined via the process data (PDout). This means that the bit must be set via IO-Link in order to activate
the output of the control value of the solenoid current controller on the magnet.
In the case of the pressure valve with an analog A1 or F1 interface, the "valve on" bit is set ex works,
so that after the pressure valve is switched on, the output of the control value of the solenoid current
controller to the solenoid takes place immediately.
Controller screen
Parameter set
Parameter set
The pressure valve is supplied with 4 parameter sets, so that the settings for the pressure command
value preparation (-> command value ramp and command value filtering) can be easily adapted to the
application of the pressure valve.
Controller screen
Filtration
Filtration
The actual pressure value detected via the internal or external pressure sensor is smoothened via a
PT1 filter whose filter frequency can be adjusted. The reasonable value range for the filter frequency is
between 10 Hz and 200 Hz.
By increasing the filter frequency, better dynamics in the closed-loop pressure control can be achieved
if the hydraulic conditions for this are fulfilled (e.g. small dead volume).
From the factory, the filter frequency is set as a compromise for the various applications of the
pressure valve (e.g. small dead volume, large dead volume).
Parameter set
Pressure controller
Feedforward control
PI controller Limitation
P-gain
- -
Filtered actual
pressure value
I-gain
CMP
Switch-off
threshold -
Active damping
Gain
I-term
Gain
Slider
active
Slider
Pressure control
deviation
Pressure command value reached
Feedforward control
With feedforward control (command value feedforward), the current pressure command value flows
into closed-loop control as a percentage. In this way, the pressure control deviation is minimized.
Feedforward control of the pressure controller is optimally set ex works for the pressure reducing valve
according to the nominal pressure. A customer setting is therefore not currently provided.
Active damping
In the pressure controller, within the framework of active damping, the change in the actual pressure
value (→ velocity) is fed back to closed-loop control with a scaling factor in order to achieve a better
controller behavior. The gain of the active damping and of the I-term can be parameterized.
Slider
With the aid of the slider, the controller behavior of the pressure controller can be easily set between
moderate, balanced and aggressive. When the slider is pressed, the corresponding values for the
following 4 parameters of the pressure controller are calculated at the same time:
• PI controller P-gain
• PI controller I-gain
• Active damping gain
• Active damping I-term gain
The slider can also be disabled so that the 4 parameters can be set independently.
Parameter set
The pressure valve is supplied with 4 parameter sets, so that the parameterization of the pressure
controller can be adapted very simply to the respective application of the pressure valve. The following
settings of the pressure controller are parameter set dependent:
• PI controller P-gain
• PI controller I-gain
• Active damping gain
• Active damping I-term gain
• Slider
• Switch-off threshold of the I-term of the PI controller
Controller screen
Closed-loop pressure
control on Solenoid current controller
PI controller with feedforward control
Pressure command
value preparation
+ Solenoid
+ - + control value
Pressure controller
Pressure/current curve Factor Dither
Pressure controller frequency
control value factor
Offset
Pressure/current curve
The pressure command value transferred to the solenoid current controller is converted into the
corresponding solenoid current command value via the pressure/current characteristic.
Controller screen
9 Parameter descriptions
9.1 P-0-0115 - Valve status word
9.1.1 Description
This parameter indicates the current status of the pressure valve.
Status word set-up:
Bit Name / Function Comment
0-1 Reserved
2 Warning
0: no warning
1: Warning active
3-7 Reserved
Parameter descriptions
10-11 Reserved
12 Pressure command value reached See also further explanation of
0: Actual pressure value did not the status bit following this table.
reach the pressure command
value
1: Actual pressure value has
reached the pressure command
value according to the defined
target window
13 Error
0: No error
1: Error active
14 Reserved
15 Enable
0: no enable
1: Enable active
Status bit “Pressure command value reached”
The status bit "Pressure command value reached" is formed when the following conditions are met:
• Enable for the valve is set
• Pressure detection of the valve is active
When the status bit is formed, it is tested whether the difference between the pressure command value
and the actual pressure value (pressure control deviation see S-0-0827) lies within a target window.
The target window is permanently set to 2% of the nominal pressure of the valve (e.g. the nominal
pressure of the valve is 200 bar → target window is 4 bar). If the pressure control deviation is within
the target window, the corresponding status bit is set in the valve status (see P-0-0115). If the pressure
control deviation leaves the target window for a period of more than 10 ms, the status bit in the valve
status (see P-0-0115) is reset.
Parameter descriptions
0-1 Parameter set number
0b00: Parameter set 0
0b01: Parameter set 1
0b10: Parameter set 2
0b11: Parameter set 3
2-7 Reserved
8-9 Operating mode
0b00: Open-loop pressure con-
trol active
0b01: Closed-loop pressure con-
trol active
0b10: reserved
0b11: reserved
10-14 Reserved
15 Enable
0: no enable
1: Enable active
Parameter descriptions
9-14 Reserved
15 Enable valve control
0: Valve output stage is not active
1: Valve output stage is active
Parameter descriptions
Parameter set Index Subindex
- 77 0
Parameter descriptions
controller and the IO-Link controller has been established.
Parameter descriptions
Internal analog input for measuring the supply voltage
28 Cable break
0: No cable break
1: Cable break detected
29 Signal exceedance
0: No signal overflow
1: Signal overflow detected
30-31 Reserved
Analog command value input: Configuration and monitoring
The analog command value input (→ connector XH1) is configured as a voltage or current input via the
control word P-0-2900.1.1.
For the command value input, monitoring for cable break, signal overload and overload is only active if
the signal range is set via the parameters P-0-2900.1.8 and P-0-2900.1.9 according to the following
table.
Configuration as Signal range (lower limit) Signal range (upper limit)
P-0-2900.1.8 P-0-2900.1.9
Current >= 3.6 mA <= 20.3 mA
Analog actual pressure value input: Configuration and monitoring
The analog actual pressure value input is configured as a voltage or current input via the control word
P-0-2900.2.1.
For the actual pressure value input, monitoring for cable break, signal overload and overload is only
active if the signal range is set via the parameters P-0-2900.2.8 and P-0-2900.2.9 according to the
following table.
Configuration as Signal range (lower limit) Signal range (upper limit)
P-0-2900.2.8 P-0-2900.2.9
Voltage >= 0.07 V <= 10.17 V
Current >= 3.6 mA <= 20.3 mA
Parameter descriptions
20 Compatibility check error
0: No error
1: Firmware on valve controller and
IO-Link controller are incompatible.
21-23 Reserved
Internal analog input for temperature measurement
24 Cable break
0: No cable break
1: Cable break detected
25 Signal exceedance
0: No signal overflow
1: Signal overflow detected
26-27 Reserved
Internal analog input for measuring the supply voltage
28 Cable break
0: No cable break
1: Cable break detected
29 Signal exceedance
0: No signal overflow
1: Signal overflow detected
30-31 Reserved
Analog command value input: Configuration and monitoring
The analog command value input (→ connector XH1) is configured as a voltage or current input via the
control word P-0-2900.1.1.
For the command value input, monitoring for cable break, signal overload and overload is only active if
the signal range is set via the parameters P-0-2900.1.8 and P-0-2900.1.9 according to the following
table.
Configuration as Signal range (lower limit) Signal range (upper limit)
P-0-2900.1.8 P-0-2900.1.9
Current >= 3.6 mA <= 20.3 mA
Analog actual pressure value input: Configuration and monitoring
The analog actual pressure value input is configured as a voltage or current input via the control word
P-0-2900.2.1.
For the actual pressure value input, monitoring for cable break, signal overload and overload is only
active if the signal range is set via the parameters P-0-2900.2.8 and P-0-2900.2.9 according to the
following table.
Configuration as Signal range (lower limit) Signal range (upper limit)
P-0-2900.2.8 P-0-2900.2.9
Voltage >= 0.07 V <= 10.17 V
Current >= 3.6 mA <= 20.3 mA
Parameter descriptions
This parameter sets the value of the slider for the pressure controller. Via the slider, the controller
behavior of the pressure controller can be easily set between moderate, balanced and aggressive.
The valve is set ex works over the complete pressure range (→ 0 bar to the nominal pressure of
the valve) for the optimal volume flow specified in the valve data sheet. Due to the aging of the
pressure valve or due to a volume flow differing from the valve data sheet, this optimum adjustment
no longer fits. This can be corrected accordingly via the offset for the solenoid current and the gain in
P-0-2890.0.7.
Parameter descriptions
9.26 P-0-2890.0.7 - Solenoid current: P-gain
9.26.1 Description
This parameter will set the gain of the solenoid current.
The valve is set ex works over the complete pressure range (→ 0 bar to the nominal pressure of
the valve) for the optimal volume flow specified in the valve data sheet. Due to the aging of the
pressure valve or due to a volume flow differing from the valve data sheet, this optimum adjustment
no longer fits. This can be corrected accordingly via the gain for the solenoid current and the offset in
P-0-2890.0.6.
Parameter descriptions
- - -
Parameter descriptions
9.37.1 Description
This parameter set the threshold at which the integrator of the pressure controller is switched off.
Switch-off behavior of the integrator The control word P-0-2890.0.4 defines whether the I-term of
the control value of the pressure controller should be frozen or deleted during the switching off of the
integrator.
Parameter descriptions
0b01: Current (4-20mA)
0b10: reserved
0b11: reserved
6-15 Reserved -
Conversion of the analog command value into V or mA into the pressure command value in bar
The voltage in V applied to the command value input or the current applied in mA is converted into a
corresponding pressure command value in bar (→ S-0-0800). The conversion into pressure command
value is defined by the following 4 parameters:
• P-0-2900.1.8
• P-0-2900.1.9
• P-0-2900.1.10
• P-0-2900.1.11
A signal range (e.g. 0-10 V) is defined via the two parameters P-0-2900.1.8 and P-0-2900.1.9,
which is converted to a value range (e.g. 0-100 bar). The value range is set using the parameters
P-0-2900.1.10 and P-0-2900.1.11.
The voltage in V applied to the command value input or the current applied in mA is converted into a
corresponding pressure command value in bar (→ S-0-0800). The conversion into pressure command
value is defined by the following 4 parameters:
• P-0-2900.1.8
• P-0-2900.1.9
• P-0-2900.1.10
• P-0-2900.1.11
A signal range (e.g. 0-10 V) is defined via the two parameters P-0-2900.1.8 and P-0-2900.1.9,
which is converted to a value range (e.g. 0-100 bar). The value range is set using the parameters
P-0-2900.1.10 and P-0-2900.1.11.
Parameter descriptions
Conversion of the analog command value into V or mA into the pressure command value in bar
The voltage in V applied to the command value input or the current applied in mA is converted into a
corresponding pressure command value in bar (→ S-0-0800). The conversion into pressure command
value is defined by the following 4 parameters:
• P-0-2900.1.8
• P-0-2900.1.9
• P-0-2900.1.10
• P-0-2900.1.11
A signal range (e.g. 0-10 V) is defined via the two parameters P-0-2900.1.8 and P-0-2900.1.9,
which is converted to a value range (e.g. 0-100 bar). The value range is set using the parameters
P-0-2900.1.10 and P-0-2900.1.11.
A signal range (e.g. 0-10 V) is defined via the two parameters P-0-2900.1.8 and P-0-2900.1.9,
which is converted to a value range (e.g. 0-100 bar). The value range is set using the parameters
P-0-2900.1.10 and P-0-2900.1.11.
Parameter descriptions
In this parameter, the lower limit of the signal range for the analog input is set, to which the internal or
external pressure sensor of the valve is connected. Depending on the type of signal set in the control
parameter P-0-2900.2.1, a value in V or mA is input in this parameter. This parameter is one of the
parameters via which the conversion of the analog actual pressure value into V or mA into the actual
pressure value into bar is set.
Conversion of the analog actual pressure value into V or mA into the actual pressure value in bar. A
voltage in V or a current in mA is present at the analog input to which the internal or external pressure
sensor of the valve is connected. This voltage or current signal is converted into a corresponding actual
pressure value in bar (→ S-0-0809). The conversion into the actual pressure value is defined by the
following 4 parameters:
• P-0-2900.2.8
• P-0-2900.2.9
• P-0-2900.2.10
• P-0-2900.2.11
A signal range (e.g. 0.1-10 V) is defined via the two parameters P-0-2900.2.8 and P-0-2900.2.9,
which is converted to a value range (e.g. 0-400 bar). The value range is set using the parameters
P-0-2900.2.10 and P-0-2900.2.11.
A voltage in V or a current in mA is present at the analog input to which the internal or external pressure
sensor of the valve is connected. This voltage or current signal is converted into a corresponding actual
pressure value in bar (→ S-0-0809). The conversion into the actual pressure value is defined by the
following 4 parameters:
• P-0-2900.2.8
• P-0-2900.2.9
• P-0-2900.2.10
• P-0-2900.2.11
A signal range (e.g. 0.1-10 V) is defined via the two parameters P-0-2900.2.8 and P-0-2900.2.9,
which is converted to a value range (e.g. 0-400 bar). The value range is set using the parameters
P-0-2900.2.10 and P-0-2900.2.11.
Parameter descriptions
Conversion of the analog actual pressure value into V or mA into the actual pressure value in bar
A voltage in V or a current in mA is present at the analog input to which the internal or external pressure
sensor of the valve is connected. This voltage or current signal is converted into a corresponding actual
pressure value in bar (→ S-0-0809). The conversion into the actual pressure value is defined by the
following 4 parameters:
• P-0-2900.2.8
• P-0-2900.2.9
• P-0-2900.2.10
• P-0-2900.2.11
A signal range (e.g. 0.1-10 V) is defined via the two parameters P-0-2900.2.8 and P-0-2900.2.9,
which is converted to a value range (e.g. 0-400 bar). The value range is set using the parameters
P-0-2900.2.10 and P-0-2900.2.11.
Parameter descriptions
0 Activation of the actual value The output of the actual pressure
output value to the analog actual value
0: Not active output is activated via the activa-
tion bit.
1: Active
1-3 Reserved -
4-5 Type of signal The type of signal is used to set
0b00: Voltage (0-10 V) whether the actual pressure value
is output as a voltage signal in
0b01: Current (4-20 mA)
the range from 0 to 10 V or as a
0b10: reserved current signal in the current range
0b11: reserved from 4 to 20 mA.
6-15 Reserved -
Parameter descriptions
Bit Name / Function Comment
0-3 Reserved
4 Valve enable forcing If the bit is set (active), the enable that is
0: Not active set via P-0-0120 is active. Otherwise, the
valve enable which is specified via parameter
1: Active
P-0-4028 (→ pressure valve with analog
interface) or P-0-1910.0.1 (→ pressure
valve with digital IO-Link interface) is active.
5 Parameter set forcing If the bit is set (active), the parameter set
0: Not active that is set via P-0-0120 is active. Otherwise,
the parameter set which is specified via
1: Active
P-0-4028 (→ pressure valve with analog
interface) or P-0-1910.0.1 (→ pressure
valve with digital IO-Link interface) is active.
6 Pressure command value forcing If the bit is set (active), then the pressure
0: Not active command value acts in P-0-2878.0.1. Other-
wise, the pressure command value is active in
1: Active
S-0-0800, which is specified via the analog
interface or the digital IO-Link interface.
7 Operating mode forcing If the bit is set (active), the operating mode
0: Not active that is set via P-0-0120 is active. Otherwise,
the operating mode which is specified via
1: Active
P-0-4028 (→ pressure valve with analog
interface) or P-0-1910.0.1 (→ pressure
valve with digital IO-Link interface) is active.
8-15 Reserved
Parameter descriptions
The contents of the displayed parameter list depends on the user currently logged in to the valve and
their access rights. The user currently logged into the valve is displayed in parameter P-0-2909.0.1.
Saving the configuration parameters
If configuration parameters are changed, they are not automatically stored, but must be remanently
secured in the valve via command S-0-0264.
When the valve condition as supplied is restored, the admin password is not reset.
Appendix
9.69 S-0-0827 - Pressure control deviation
9.69.1 Description
This parameter displays the current pressure control deviation.
10 Appendix
10.1 List of addresses
Contacts for service and spare parts
Bosch Rexroth AG
Bürgermeister-Dr.-Nebel-Straße 8
97816 Lohr am Main, Germany
Phone +49 (0) 9352/40 50 60
Email: service@boschrexroth.de
Headquarters
Bosch Rexroth AG
Zum Eisengiesser 1
97816 Lohr am Main, Germany
Phone +49 (0) 9352/18-0
The addresses of our sales and service network and sales organizations can be found at
www.boschrexroth.com/adressen
Index
Actual pressure value filtration. . . . . . . . . . . . . 62 Solenoid current controller. . . . . . . . . . . . . 53, 68
Analog interface . . . . . . . . . . . . . . . . . . . . . . . . 22 V
Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Validity of the documentation. . . . . . . . . . . . . . 12
B Valve types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Backup/Restore. . . . . . . . . . . . . . . . . . . . . . . . . 42
Bluetooth® dongle. . . . . . . . . . . . . . . . . . . . . . . 19
C
Closed-loop pressure control. . . . . . . . . . . . . . 63
Controller structure (Z)3DREA. . . . . . . . . . . . . 56
Controller structure (Z)3DREE. . . . . . . . . . . . . 48
E
Editions of this documentation. . . . . . . . . . . . . 12
External pressure sensor – interface X2N . . . . 43
G
General information on this chapter. . . . . . . . . 13
General safety instructions. . . . . . . . . . . . . . . . 15
I
Improper use. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Internal pressure sensor. . . . . . . . . . . . . . . . . . 42
L
List of addresses. . . . . . . . . . . . . . . . . . . . . . . 107
O
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 48
P
Parameter descriptions. . . . . . . . . . . . . . . . . . . 70
Pressure command value. . . . . . . . . . . . . . . . . 23
Pressure command value preparation. . . . 51, 60