Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

RS-All Digital PET 2022 Flyer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 25

001 The Pioneer of All Digital PET

Visible Electrical
γ-ray Light Pulse Singles Coincidece PET Image

(MVT)
001 002 003 004
Algorithm adaptability AI Enabled Application adaptation Hotkey operation
Fulfill the individual needs in various Artificial intelligence, machine learning, Selects the best method automatically, as Form a protocol for various applications
applications radiomics, etc well as self-tunes continually

Pulse Coincidence Calibration& Image


Reconstruction Algorithm Image Reconstruction Processing

Tumor
Image Protocol 1

Singles Sinogram Dicom Brain


Image Protocol 2
Original
Samples
Whole
Body Protocol 3
Image

Other
Protocol 4
Image

006 007
001 The Pioneer of All Digital PET

LYSO Scintillator
High Light Yield
Fast Light Output

One to One Coupling


SiPM Photodetector Lossless Digitization of All
Independent Channel
Small Size
High PDE
High SNR Location independent acquisition
Magnetic Field Compatibility Signal stack reduction
Ultra-high count rate
Ultra-high detection efficiency

MVT Digitized
Digital Signal Output
Multi-Channel
Zero-Dead time
Quantitative Imaging, Precise Diagnosis
Zero-Dead time
002 All Digital PET
002 All Digital PET

Ultra HD image for clinical


002 All Digital PET

Ultra-high performance for clinical and


research applications
002 All Digital PET

Explore the relationship between brain and


heart not limited to the conventional scanning
002 All Digital PET

100cm Axial FOV,


from head to abdomen
002 All Digital PET

Panoramic vision,extreme performance


002 All Digital PET

Brain PET with Ultra-high time


resolution and spacial resolution
002 All Digital PET

Pioneer of brain and cognitive science


003 Product Performance of DigitMI 930

Sensitivity increased by 6 times

Whole-body scan 1/5 scan time

135s

min

0026 0027
003 Product Performance of DigitMI 930

Radioactive drugs reduced to 1/3

Injected Dose
CMOS SiPM, the most efficient photon detection

1:1 read out, more than 12000 individual data processing channels, complete
acquisition of all events

0028 0029
003 Product Performance of DigitMI 930

TOF Digitalize the signal source straightway to obtain the pulse signal precisely

Light-optical coupling technology, maximize the optical output, improve


the signal to noise ratio

Superfine reconstruction to increase the signal-to-noise ratio by 4 times

AI-Correction
Intelligent correction for more uniform system response

0030 0031
003 Product Performance of DigitMI 930

Reconstruction Pixel The signal source is digitized directly with 100% fidelity

The scintillation crystal is coupled with the photoelectric device 1:1,


completely getting rid of the position decoding error

Superfine reconstruction to achieve super resolution

0032 0033
004 Service

5 years free warranty

Optional Services Digital Intelligence Modular


more stable more accurate quick positioning,
quick replacement
0034 0035
004 Service

hours

Fast troubleshooting

0036 0037
004 Service

hours

Flash upgrade
Axial FOV can be extended from 10cm to 20cm to 30cm
and even to 60cm
Software OTA supported

0038 0039
005 Application Case

Female, 53 years old, 51kg, Breast cancer Male, 55 yearrs old, 60.7kg, Lymphoma Male, 52 years old, 79.5kg, Diffuse lymph Female, 72 years old, 65.8kg, Diffuse bone
with diffuse bone node enlargement metastases

Male, 76 years old, 70.9kg,Kidney cancer Male, 69 years old, 69.4kg,Colon Cancer Male, 55 years old, 43.5kg, Cardia cancer Male,53 years old, 53.8kg, Lung cancer with
with diffuse bone metastasis with perigastric metastasis multiple metastases
005 Application Case

Brain image Male, 60 years old, 75kg, Bone marrow reaction hyperplasia after lymphoma treatment
005 Application Case

Female, 72years old, 65.8kg, Diffuse bone metastases Male, 69 years old, 53kg, Vertebrae Infection, diffuse bone metastases
005 Application Case

Male,73 years old, 47kg, Lung Cancer Male, 75 years old, 50.7kg,Lung Cancer
006 Research

MULTIPLE STUDIES
WITH THE SAME DATA
All original data will be retained with once scan, multiple parameters and methods can be
used to obtain different image, in order to obtain individualized and optimal results

Algorithm 1

Multiple methods for


extracting scintillation Multiple methods for selecting
pulse information true coincidence events
Algorithm 2

Algorithm 3 Multiple methods for Multiple methods


image reconstruction for correction

0048 0049
006 Research

ABSOLUTE QUANTITATIVE
COORDINATE SYSTEM
All the scan results obtained by anyone at anytime and anywhere with any scanner
will be in the same coordinate system

Human
body

Large Human body


animal

In vitro Large animal Large animal


Small
animal
Small animal
In vitro

In vitro

Small animal Human body


first time second time third time fourth time

0050 0051

You might also like