Vibranivo ® Mononivo ®

Series Series
VN 4000 MN 4000

Instruction manual

010516

1
UWT GmbH
Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de
D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de

Scope of this Types VN 4020 4030


instruction MN 4020 4030
manual: Approval CE / TR-CU
ATEX 1/2D IEC-Ex t IIIC

Electronic modules Relais (DPDT) PNP

2
Table of Contents

Safety /warning notes Page 4

Fields of application Page 4

Technical Data Page 4

Application Page 11

Installation Page 13

Spare parts Page 18

Electrical connection Page 19

Switching logic Page 21

Maintenance Page 22

ATEX / IEC-Ex Notes Page 23

3
Safety /warning notes
Installation, maintenance and commissioning may be accomplished only by
qualified technical personnel.
For terminal connection of the device, the local regulations or VDE 0100
(Regulations of German electrotechnical Engineers) must be observed.
All field wirings must have insulation suitable for at least 250V AC. The
temperature rating must be at least 90°C (194°F).
In the case of handling by untrained personnel or handling malpractice, the
safety of the device cannot be guaranteed.

Fields of application

Level limit switch for level limit detection in powder and bulk materials.

4
Technical Data

°C

VN 4020
125mm
(4.92“)

300mm (11.78“)
R 1 1/2“
NPT 1 1/4“
NPT 1 1/2“
1.4541 (321)
170mm (6.69“)

1.4581 (316)
1.4404 (316L)
125mm
(4.92“)

170mm (6.69“)

1.4581
(316L)
125mm
(4.92“)

°C
1 9 2 9

-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)

~ 1,7kg (3.7 lbs) ~ 2,4kg (5.3 lbs)

5
°C

VN 4030 125mm
(4.92“)

300mm (11.78“)
R 1 1/2“
NPT 1 1/4“
NPT 1 1/2“

1.4541 (321)
1.4571 (316TI)
1.4404 (316L)
L<4.000mm (157.5“)

L<4.000mm (157.5“)
125mm
(4.92“)

125mm
(4.92“)

1.4581
(316L)

°C
1 / 2 9 2 9

-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
~1,7kg (3.7lbs) ~2,4kg (5.3lbs)
+1,9kg/m +1,9kg/m
(+4.2 lbs per 39.9“) (L) (+5.5 lbs per 39.9“) (L)

6
°C

MN 4020
122mm
(4.8“)

300mm (11.78“)
G 1"
G 1 1/4"
G 1 1/2“
160mm (6.3“)

NPT 1"
130mm

NPT 1 1/4"
(5.12“)

NPT 1 1/2"

1.4301 (304)
1.4541 (321)/
160mm (6.3“)

1.4404 (316L)
130mm
(5.12“)

°C
1 9 2 9

-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)

~ 1,3kg (2.9 lbs) ~ 2,0kg (4.5 lbs)

7
°C

MN 4030
122mm
(4.8“)

300mm (11.78“)
G 1"
G 1 1/4"
G 1 1/2“
NPT 1"
NPT 1 1/4"
NPT 1 1/2"
L<4.000mm (157.5“)

L<4.000mm (157.5“)
130mm
(5.12“)

130mm

1.4301 (304)
(5.12“)

1.4541 (321)/
1.4404 (316L)

°C
1 / 2 9 2 9

-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
~1,3kg (2.9lbs) ~2,0kg (4.5lbs)
+1,3kg/m +1,3kg/m
(+2.9 lbs per 39.9“) (L) (+2.9 lbs per 39.9“) (L)

8
°C

1 Tamb

60°C
(140°F)
Tamb
40°C
(104°F) Tprocess Tprocess
-40°C 60°C 150°C
(-40°F) (140°F) (302°F)

-40°C
(-40°F)

2 Tamb

60°C
ø 50mm
(140°F)
180 mm

(ø 1.97“)
(7.1“)

Tamb
Tprocess
-40°C 150°C Tprocess
(-40°F) (302°F)

-40°C
(-40°F)

9
Sensitivity

VN 4000
>30 g/l B
>150 g/l A

1g/l = 0.06 lb/ft³

MN 4000 >20 g/l

>80 g/l

>150 g/l

>300 g/l

1g/l = 0.06 lb/ft³

Bulk material

VN 4000:
d < 8mm (0.31“)

MN 4000:
d < 20mm (0.79“)

10
Application

VN 4020
MN 4020

(2)
(1)
VN 4020 <600N
200mm
MN 4020 <400N
(7.87“)

VN 4020

(1) Mech. load of the sensor


(2) Protective angle (canopy) in case of high mechanical load

11
VN 4030
MN 4030

(2)

< 250Nm (1)

α max. L / mm ( ” )
L

< 5° 4.000 (157.5 )


< 45° 1.200 (47.2 )
> 45° 600 (23.6 )

< 250Nm (1)

(1) Mech. load of the sensor


(2) Sliding sleeve: Tighten straining screws with 20Nm

12
Assembly

Fixing Threads

Teflon tape or flat gasket 80Nm

Fixing Flanges

Gasket

13
Fixing EHEDG

100Nm

(4)
(1) (2) (3)

(1) Certified flush welding socket must be used


(2) Metal-metal support without any gap
(3) Sealing ring
(4) Welding (observe hygiene requirements)

14
Alignment

(1)

(1)

VN 4000

(1) Ingress protection IP 66

15
Treatment

VN 4000

MN 4000

16
Option: Weather protection cover

for Ex only approved for Zone 22

17
Spare parts

VN 4000

19...230V 50/60 Hz
pl408265
19...40V DC
18...50V DC PNP pl408266

MN 4000

21...230V 50/60 Hz
pl405265
22...45V DC
18...50V DC PNP pl405266

18
Electrical connection

All electronic modules: Over voltage category II

Relay DPDT

VN 4000
MN 4000

max. 4mm²
1 2 3 4 5 6 7 8 (AWG12)

(4) (4) (4) (4)


max. 10A, HBC,
250V, T/F

PE + - AC max. 250V, 8A
L N DC max. 30V, 5A
(1)
(1)
VN 4000: 19...230V ±10% (3) 50-60Hz 22VA 19... 40V ±10% (3) DC 2W
MN 4000: 21...230V ±10% (3) 50-60Hz 22VA 22... 45V ±10% (3) DC 2W

2225Vrms

(2) 2225Vrms

(1) Power supply


(2) Isolating voltage
(3) including 10% from EN 61010

19
PNP

VN 4000
MN 4000

max. 4mm²
(AWG12)

1 2 3

max.
max. 4A, 0,4A
250V, T/F

PE + -
18...50V ±10% (1)
0,5A

(1) Power supply, including 10% from EN 61010

20
Switching logic

VN 4000 MN 4000
FSL
FSL
FSH
FSH

FSL FSH

(1)
3 4 5 6 7 8 3 4 5 6 7 8

(2)
1 3 1 3

(1)
3 4 5 6 7 8 3 4 5 6 7 8

(2)
1 3 1 3

(1) = Relay DPDT


(2) = PNP
21
Maintenance

Cleaning
VN 4000 MN 4000

22
ATEX II 1/2D + IEC-Ex t IIIC Da/Db
Notes

Permitted relative pressure

-0,2...+0,1bar
(-2.9…+1.45psi)

Zone borders

VN 4030
VN 4020 MN 4020 MN 4030

(1) 2D
(2) Db
(3) 21

(1) 1D
(2) Da
(3) 20

(1) Category (2) EPL (IEC-Ex) (3) Zone

23
Ambient temperature max. Surface temperature

T
VN 4000
MN 4000
110°C (230°F) 115°C (239°F)
60°C 120°C (248°F) 120°C (248°F)
(140°F) 130°C (266°F) 130°C (266°F)
140°C (284°F) 140°C (284°F)
150°C (302°F) 150°C (302°F)

Installation

(1)

(2)

(1) A pull relief must be provided


(2) Connect with equipotential bonding of the plant

24
ATEX / IEC-Ex: Further Remarks

For installation and field wiring the respectively valid installation regulations of the
respective country must be observed.
Commissioning only with closed lid.
Do not remove the lid (cover) while circuits are alive.
Before opening the lid take care, that no dust deposits or whirlings are present.
The installation has to be carried out in a way, that mechanical friction or impact
does not cause sparks between the aluminium enclosure and steel.
Cable glands:
Installation according to the regulations of the country, where the product is
installed.
Not used entries have to be closed with blanking elements certified for this
purpose.
Where applicable the factory provided parts must be used.
A strain relief must be provided for the field wiring cables, when the device is
installed with the factory
provided cable glands.
The diameter of the field wiring cable must match to the clamping range of the
cable clamp.
If other than the factory provided parts are used, following must be ensured:
The parts must have an approval adequate to the approval of the level sensor
(certificate and type of protection).
The approved temperature range must be from the min. ambient temperature of
the level sensor to the max. ambient temperature of the level sensor increased by
10 Kelvin.
The parts must be mounted according to the instructions of the supplier.