Series Series
VN 4000 MN 4000
Instruction manual
010516
1
UWT GmbH
Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de
D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de
2
Table of Contents
Application Page 11
Installation Page 13
Maintenance Page 22
3
Safety /warning notes
Installation, maintenance and commissioning may be accomplished only by
qualified technical personnel.
For terminal connection of the device, the local regulations or VDE 0100
(Regulations of German electrotechnical Engineers) must be observed.
All field wirings must have insulation suitable for at least 250V AC. The
temperature rating must be at least 90°C (194°F).
In the case of handling by untrained personnel or handling malpractice, the
safety of the device cannot be guaranteed.
Fields of application
Level limit switch for level limit detection in powder and bulk materials.
4
Technical Data
°C
VN 4020
125mm
(4.92“)
300mm (11.78“)
R 1 1/2“
NPT 1 1/4“
NPT 1 1/2“
1.4541 (321)
170mm (6.69“)
1.4581 (316)
1.4404 (316L)
125mm
(4.92“)
170mm (6.69“)
1.4581
(316L)
125mm
(4.92“)
°C
1 9 2 9
-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
5
°C
VN 4030 125mm
(4.92“)
300mm (11.78“)
R 1 1/2“
NPT 1 1/4“
NPT 1 1/2“
1.4541 (321)
1.4571 (316TI)
1.4404 (316L)
L<4.000mm (157.5“)
L<4.000mm (157.5“)
125mm
(4.92“)
125mm
(4.92“)
1.4581
(316L)
°C
1 / 2 9 2 9
-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
~1,7kg (3.7lbs) ~2,4kg (5.3lbs)
+1,9kg/m +1,9kg/m
(+4.2 lbs per 39.9“) (L) (+5.5 lbs per 39.9“) (L)
6
°C
MN 4020
122mm
(4.8“)
300mm (11.78“)
G 1"
G 1 1/4"
G 1 1/2“
160mm (6.3“)
NPT 1"
130mm
NPT 1 1/4"
(5.12“)
NPT 1 1/2"
1.4301 (304)
1.4541 (321)/
160mm (6.3“)
1.4404 (316L)
130mm
(5.12“)
°C
1 9 2 9
-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
7
°C
MN 4030
122mm
(4.8“)
300mm (11.78“)
G 1"
G 1 1/4"
G 1 1/2“
NPT 1"
NPT 1 1/4"
NPT 1 1/2"
L<4.000mm (157.5“)
L<4.000mm (157.5“)
130mm
(5.12“)
130mm
1.4301 (304)
(5.12“)
1.4541 (321)/
1.4404 (316L)
°C
1 / 2 9 2 9
-1 .. +16bar -1 .. +16bar
(-14.5 .. +232psi) (-14.5 .. +232psi)
~1,3kg (2.9lbs) ~2,0kg (4.5lbs)
+1,3kg/m +1,3kg/m
(+2.9 lbs per 39.9“) (L) (+2.9 lbs per 39.9“) (L)
8
°C
1 Tamb
60°C
(140°F)
Tamb
40°C
(104°F) Tprocess Tprocess
-40°C 60°C 150°C
(-40°F) (140°F) (302°F)
-40°C
(-40°F)
2 Tamb
60°C
ø 50mm
(140°F)
180 mm
(ø 1.97“)
(7.1“)
Tamb
Tprocess
-40°C 150°C Tprocess
(-40°F) (302°F)
-40°C
(-40°F)
9
Sensitivity
VN 4000
>30 g/l B
>150 g/l A
>80 g/l
>150 g/l
>300 g/l
Bulk material
VN 4000:
d < 8mm (0.31“)
MN 4000:
d < 20mm (0.79“)
10
Application
VN 4020
MN 4020
(2)
(1)
VN 4020 <600N
200mm
MN 4020 <400N
(7.87“)
VN 4020
11
VN 4030
MN 4030
(2)
α max. L / mm ( ” )
L
12
Assembly
Fixing Threads
Fixing Flanges
Gasket
13
Fixing EHEDG
100Nm
(4)
(1) (2) (3)
14
Alignment
(1)
(1)
VN 4000
15
Treatment
VN 4000
MN 4000
16
Option: Weather protection cover
17
Spare parts
VN 4000
19...230V 50/60 Hz
pl408265
19...40V DC
18...50V DC PNP pl408266
MN 4000
21...230V 50/60 Hz
pl405265
22...45V DC
18...50V DC PNP pl405266
18
Electrical connection
Relay DPDT
VN 4000
MN 4000
max. 4mm²
1 2 3 4 5 6 7 8 (AWG12)
PE + - AC max. 250V, 8A
L N DC max. 30V, 5A
(1)
(1)
VN 4000: 19...230V ±10% (3) 50-60Hz 22VA 19... 40V ±10% (3) DC 2W
MN 4000: 21...230V ±10% (3) 50-60Hz 22VA 22... 45V ±10% (3) DC 2W
2225Vrms
(2) 2225Vrms
19
PNP
VN 4000
MN 4000
max. 4mm²
(AWG12)
1 2 3
max.
max. 4A, 0,4A
250V, T/F
PE + -
18...50V ±10% (1)
0,5A
20
Switching logic
VN 4000 MN 4000
FSL
FSL
FSH
FSH
FSL FSH
(1)
3 4 5 6 7 8 3 4 5 6 7 8
(2)
1 3 1 3
(1)
3 4 5 6 7 8 3 4 5 6 7 8
(2)
1 3 1 3
Cleaning
VN 4000 MN 4000
22
ATEX II 1/2D + IEC-Ex t IIIC Da/Db
Notes
-0,2...+0,1bar
(-2.9…+1.45psi)
Zone borders
VN 4030
VN 4020 MN 4020 MN 4030
(1) 2D
(2) Db
(3) 21
(1) 1D
(2) Da
(3) 20
23
Ambient temperature max. Surface temperature
T
VN 4000
MN 4000
110°C (230°F) 115°C (239°F)
60°C 120°C (248°F) 120°C (248°F)
(140°F) 130°C (266°F) 130°C (266°F)
140°C (284°F) 140°C (284°F)
150°C (302°F) 150°C (302°F)
Installation
(1)
(2)
24
ATEX / IEC-Ex: Further Remarks
For installation and field wiring the respectively valid installation regulations of the
respective country must be observed.
Commissioning only with closed lid.
Do not remove the lid (cover) while circuits are alive.
Before opening the lid take care, that no dust deposits or whirlings are present.
The installation has to be carried out in a way, that mechanical friction or impact
does not cause sparks between the aluminium enclosure and steel.
Cable glands:
Installation according to the regulations of the country, where the product is
installed.
Not used entries have to be closed with blanking elements certified for this
purpose.
Where applicable the factory provided parts must be used.
A strain relief must be provided for the field wiring cables, when the device is
installed with the factory
provided cable glands.
The diameter of the field wiring cable must match to the clamping range of the
cable clamp.
If other than the factory provided parts are used, following must be ensured:
The parts must have an approval adequate to the approval of the level sensor
(certificate and type of protection).
The approved temperature range must be from the min. ambient temperature of
the level sensor to the max. ambient temperature of the level sensor increased by
10 Kelvin.
The parts must be mounted according to the instructions of the supplier.
25