SERIES APT
AC POWER TRANSFORMERS D
20 to 150 VA, Single or Dual Hub, Circuit Breaker, UL Class 2 A
E
C B
Dimensions in [mm]
Model A B C D E
APT-20-0SN 1-31/64 [37.6] 1-21/32 [41.9] 1-7/8 [47.5] 2-17/64 [57.4] 2-39/64 [66.2]
APT-40-3SN APT-50-5DB APT-20-1SN 1-31/64 [37.6] 1-21/32 [41.9] 1-7/8 [47.5] 2-17/64 [57.4] 2-39/64 [66.2]
APT-40-3SN 1-61/64 [49.5] 1-25/32 [45.2] 2-11/64 [55.0] 2-43/64 [68.0] 2-7/8 [73.0]
APT-40-5DN 1-61/64 [49.5] 1-25/32 [45.2] 2-11/64 [55.0] 2-3/4 [70.0] 2-7/8 [73.0]
APT-50-5DB 1-13/16 [46.0] 1-31/32 [50.2] 2-1/2 [63.5] 3-7/16 [87.1] 3-1/32 [77.0]
APT-50-5SB 1-13/16 [46.0] 1-31/32 [50.2] 2-1/2 [63.5] 3-7/16 [87.1] 3-1/32 [77.0]
APT-75-5DB 2-13/64 [56.0] 1-31/32 [50.2] 2-1/2 [63.5] 3-53/64 [97.1] 3-1/32 [77.0]
APT-75-5SB 2-13/64 [56.0] 1-31/32 [50.2] 2-1/2 [63.5] 3-53/64 [97.1] 3-1/32 [77.0]
APT-100-5DB 2-39/64 [66.0] 1-31/32 [50.2] 2-1/2 [63.5] 4-1/4 [107.1] 3-1/32 [77.0]
APT-100-5SB 2-39/64 [66.0] 1-31/32 [50.2] 2-1/2 [63.5] 4-1/4 [107.1] 3-1/32 [77.0]
APT-50-5SB APT-150-1DB 2-33/64 [64.0] 1-31/32 [50.2] 2-1/2 [63.5] 3-9/16 [90.5] 3-1/32 [77.0]
The Series APT AC Power Transformers provide isolated step-down to 24 VAC with SPECIFICATIONS
models offering VA ratings of 20, 40, 50, 75, 96, or 150 VA’s. These cost efficient Input Voltage: See model chart.
transformers are offered in single or dual 1/2˝ NPT threaded hub mounts with 8-1/2˝ Input Frequency: 50/60 Hz.
18 AWG wire leads, to meet the installation requirements of a variety of building Output Voltage: See model chart.
automation and control panel applications in HVAC. All models are UL Class 2 listed. Output VA Rating: 20, 40, 50, 75, 96, or 150 VA.
Mounting: Slotted foot mount with single, or dual 1/2˝ NPT hub.
BENEFITS/FEATURES Current Protection: See model chart.
• Single or dual 1/2˝ NPT Electrical Connections: Models ending in -20: 20˝ (508 mm) 18 AWG leads; All
• Universal supply voltage input other models: 8.5˝ (210 mm) 18 AWG leads.
• With or without integral circuit breaker Weight: See model chart.
Compliance: CE, cULus.
APPLICATIONS
• BAS
• HVAC
MODEL CHART
Model Rating Input Voltage Output Voltage Mounting Current Protection Wiring
APT-20-0SN 20 VA 24 VAC 24 VAC Foot mount with single hub Inherent Diagram B
Power Transformers
APT-20-1SN 20 VA 120 VAC 24 VAC Foot mount with single hub Inherent Diagram A
APT-40-0SN 40 VA 24 VAC 24 VAC Foot mount with single hub Inherent Diagram B
APT-40-1DN 40 VA 120 VAC 24 VAC Foot mount with dual hub Inherent Diagram A
APT-40-1SN 40 VA 120 VAC 24 VAC Foot mount with single hub Inherent Diagram A
APT-40-2DN 40 VA 240 VAC 24 VAC Foot mount with dual hub Inherent Diagram C
APT-40-2SN 40 VA 240 VAC 24 VAC Foot mount with single hub Inherent Diagram C
APT-40-3SN 40 VA 120/208/240/277 VAC 24 VAC Foot mount with single hub Inherent Diagram D
APT-40-5DN 40 VA 120/208/240/277/480 VAC 24 VAC Foot mount with dual hub Inherent Diagram C
APT-50-1DB 50 VA 120 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram A
APT-50-1DN 50 VA 120 VAC 24 VAC Foot mount with dual hub Inherent Diagram A
APT-50-1SB 50 VA 120 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram A
APT-50-1SN 50 VA 120 VAC 24 VAC Foot mount with single hub Inherent Diagram A
APT-50-2DB 50 VA 240 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-50-2DN 50 VA 240 VAC 24 VAC Foot mount with dual hub Inherent Diagram C
APT-50-2SB 50 VA 240 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-50-2SN 50 VA 240 VAC 24 VAC Foot mount with single hub Inherent Diagram C
APT-50-5DB 50 VA 120/208/240/277/480 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-50-5SB 50 VA 120/208/240/277/480 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-75-1DB 75 VA 120 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram A
APT-75-1SB 75 VA 120 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram A
APT-75-2DB 75 VA 240 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-75-2SB 75 VA 240 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-75-5DB 75 VA 120/208/240/277/480 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-75-5SB 75 VA 120/208/240/277/480 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-100-1DB 96 VA 120 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram A
APT-100-1DB-20 100 VA 120 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram A
APT-100-1SB 96 VA 120 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram A
APT-100-2DB 100 VA 240 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-100-2SB 100 VA 240 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-100-5DB 100 VA 120/208/240/277/480 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram C
APT-100-5SB 100 VA 120/208/240/277/480 VAC 24 VAC Foot mount with single hub Button circuit breaker Diagram C
APT-150-1DB 150 VA 120 VAC 24 VAC Foot mount with dual hub Button circuit breaker Diagram A