Catalogue Cover Page Portable
Catalogue Cover Page Portable
Catalogue Cover Page Portable
CATALOGUE 2021
0343
0098
Dear Readers,
In the course of time, the company has become a holistically thinking of becoming one of the world market leader. Today,
EVERSAFE has 170 employees, supporting more than 46 countries; inclusive of USA, La�n America, Scandinavian countries,
European countries, Mediterranean countries, Brazil, Africa, Middle East, SAARC, South East Asia, Australasia and is valued
worldwide as the solution for fire fighting.
Eversafe Ex�nguisher Sdn. Bhd. incorporated in the year 1979 is a member of Leeden Na�onal Oxygen Ltd, Singapore. Our
produc�on of fire-figh�ng equipment is housed within 2.844 acres of manufacturing and R&D facili�es which allows us to
offer an extensive range of high-quality products and systems. We operates a Quality Management System which
complies with the global requirements of BS EN ISO 9001 and holds an ISO 9001 cer�ficate from BSI, United Kingdom.
Besides that, its superior quality products and equipment are also cer�fied by recognised interna�onal cer�fica�on bodies
We continually invest in innovating our products, services and business solutions, also by engaging with partners and
expanding our customer support to help our customer about products and services in line to create strong networks, focus
on applications in the fields of fire fighting industries.
Quality, reliability, experience, innovation are words that you associate with . Our reputation is based on our
commitment to improve.
Sincerely,
Your EVERSAFE team. Our Website
Further information on our product por�olio, service
offerings and current sales promo�on can be found on
our website. Visit us at:
www.eversafe.net
store.eversafe.net
We are the manufacturer Product Standard/Certification
/distributor of American Standard (UL)
Australian Standard (SAI Global)
Portable Fire Ex�nguishers
European Standard (BSI / LPCB)
Mobile Fire Ex�nguishers
Malaysian Standard (SIRIM / WATERMARK / SPAN / IKRAM)
Fire Hose Reels
Singapore Standard (TÜV SÜD PSB )
Landing Valves
Construc�on Product Direc�ve , CPD / CPR (BRE)
Breeching Inlets
Pressure Equipment Direc�ve, CE Mark
Fire Hydrant Equipment
(Lloyd’s Register)
CO2 Fire Ex�nguishing System
Marine Equipment Direc�ve, Wheel Mark (DNV-GL)
NAF S 227® Fire Ex�nguishing System
Offshore Special Regula�ons - Sarawak Shell Bhd / Sarawak
NAF S 125® Fire Ex�nguishing System
Shell Petroleum Co (SSB / SSPC)
NAF S 1230® Fire Ex�nguishing System
Kuwait Na�onal Petroleum Co (KNPC)
Inert Gases Fire Ex�nguishing Systems
Kuwait Oil Company (KOC)
Amerex Kitchen Protec�on Fire Suppression System
Oman Ministry Of Defense (MOD)
Fire Sprinkler System
UAE Ministry of Interior Civil Defense
Nozzles
Tenaga Nasional Berhad (TNB / SGP)
Fire Detec�on
Control Panel
Fire Blankets
Canvas Hoses
Cabinets
Monnex Powder
Foam Compound
PRODUCT APPROVALS
0343
0098
Table of Content
Portable Fire Ex�nguisher 1 - 30
Introduc�on 1-2
MS Series 3-6
CR-MS Series 7-8
MED Series 9 - 13
KMCE Series 14 - 18
CR-KM Series 19 - 24
DE Series 25 - 27
TÜV SÜD PSB Series 28 - 30
ii
Portable Fire
Extinguishers
Eversafe international Portable Extinguisher
standards/directives Features
European Standard - BS EN 3 Seamless steel CO2 Cylinder
Malaysian Standard - MS 1539 Fully deep drawn from cold rolled steel welded cylinder
Australian Standard - AS/NZS 1841 Pressure tested to twice the ex�nguisher's working pressure
Singapore Standard - SS EN 3 Externally coated with epoxy polyester powder
PED (Pressure Equipment Direc�ve) Passed 480-hours salt spray test
MED (Marine Equipment Direc�ve)
Corrosion Resistant
Features
Stainless steel squeeze lever and bo�om handle
Reinforced synthe�c rubber hose
Cylinder is externally coated with Epoxy Marine Paint System
over sandblasted surface
Galvanized metal bracket
Passed salt spray test for 720 hours, 1.5 �mes the usual test
period of 480 hours
Type Of Extinguishers
Dry Chemical Powder (ABC) Monnex Powder Foam/Fluorine Free (AFFF/FF)
Dry Chemical Powder (ABC) is a mixture of Based on potassium bicarbonate-urea comp- AFFF C6 is synthe�c aqueous film forming
highly efficient mono-ammonium phosphate lex. Monnex is par�cularly effec�ve against foam concentrate consists of specific
and ammonium suphate ground to selected fire involving alcohols, ketones and esters, fluorinated and hydrocarbon surfactants to
par�cle sizes. It is a versa�le and safe which are more difficult for conven�onal fire allow forma�on of an aqueous film on the
ex�nguishant, and is ideally suited to enviro- figh�ng agents. It is recommended for high surface of most hydrocarbon fuels, suppres-
nment where the fire hazard is mixed. It also risk situa�on and should be used when rapid sing vapour leaks and preven�ng its contact
fast offers fast protec�on against reigni�on knockdown is required for class B and C fires. with the oxygen and providing an excelling
and heat reduc�on. Effec�ve against class A, It is par�cularly use in refineries, petroche- sealing on hot surfaces. Its formula�on
B, C and live electrical fires. mical complexes and other high hazard areas. allows a great oil repellence, fluidity and
burnback resistance.
The most commonly used ex�nguishers The ideal agent for use on class B fires. An aqueous solu�on that is suitable to use
for class A fire involving cabonaceous It is non toxic, non conduc�ve and on class F fire, which involves cooking
materials such as wood, tex�les and non corrosive inert gas which works by oils and fats. It reacts with the burning
paper by cooling the fire and removing smothering the flames and reducing the oil or fat forming a ‘blanket’ which
the heat needed for combus�on. oxygen content of the air around fire. rapidly knocks the flames out, cools
This agent also safe to use on live the burning oil and chemically reacts
electrical fires. to form a soap-free subtance, sealing
the surface and preven�ng re-igni�on.
1 1
Stored Pressure Type Catridge Operated Type
Gas
Cartridge
Spray
Nozzle Cylinder
Body
Designed to Guarantee
Superb Performance
2x
Records Date/Interval
of Servicing Performed
on Individual
Fire Extinguisher
Permanent Stamping of manufactured date
and Distinctive Serial Number Ensures
Product Traceability
Evidence of Pressure Test Conducted
2
Stored Pressure Type - MS Series
3
Stored Pressure Type - MS Series
4
Stored Pressure Type - MS Series
5
Cartridge Operated Type & Stored Pressure Type - MS Series
6
Stored Pressure Type/Cartridge Operated Type - CR-MS Series
ABC & Monnex Dry Powder Portable Fire Extinguishers
Maintenance Tag
7
Stored Pressure Type - CR-MS Series
AFF Foam, Wet Chemical & CO Portable Fire Extinguishers
Maintenance Tag
8
Cartridge Operated Type - MED Series
0343 0098
B, C
Internal Coating
RAL 3000 Flame Red Epoxy Polyester Powder Coating
91
Cartridge Operated Type - MED Series
0343 0098
Internal Coating
RAL 3000 Flame Red Epoxy Polyester Powder Coating
10
Stored Pressure Type - MED Series
0343 0098
18 sec
A, B, C + Electrical
Internal Coating
RAL 3000 Flame Red Epoxy Polyester Powder Coating
Plastic Bracket*
11
Stored Pressure Type - MED Series
0343 0098
EEW-6s
8
10 12
0343 0098
13
11
Stored Pressure Type - KMCE Series
ABC Dry Powder Portable Fire Extinguishers
0343
14
Stored Pressure Type - KMCE Series
AFF Foam, Water & Wet Chemical Fire Extinguishers
0343
15
Stored Pressure Type - KMCE Series
Carbon Dioxide Portable Fire Extinguishers
0343
EEC 6.8
EEC 6.8
16
Cartridge Operated Type - KMCE Series
ABC Powder & Monnex Powder Portable Fire Extinguishers
0343
17
Cartridge Operated Type - KMCE Series
AFF Foam, Water & Wet Chemical Portable Fire Extinguishers
0343
18
Stored Pressure Type - CR-KM Series
ABC Dry Powder Portable Fire Extinguishers
Maintenance Tag
19
Stored Pressure Type - CR-KM Series
AFF Foam & Water Portable Fire Extinguishers
Maintenance Tag
20
Stored Pressure Type - CR-KM Series
Wet Chemical Portable Fire Extinguishers
Maintenance Tag
21
Stored Pressure Type - CR-KM Series
Carbon Dioxide Portable Fire Extinguishers
Maintenance Tag
22
Cartridge Operated Type - CR-KM Series
ABC & Monnex Powder Portable Fire Extinguishers
Maintenance Tag
23
Cartridge Operated Type - CR-KM Series
AFF Foam, Water & Wet Chemical Portable Fire Extinguishers
Maintenance Tag
24
Stored Pressure Type - DE Series
ABC Dry Powder Portable Fire Extinguishers
25
Stored Pressure Type - DE Series
AFF Foam & Water Portable Fire Extinguishers
26
Stored Pressure Type - DE Series
Carbon Dioxide Portable Fire Extinguishers
2729
Stored Pressure Type - TÜV SÜD PSB Series
ABC Dry Powder Portable Fire Extinguishers
5252 mm
30 28
Stored Pressure Type - TÜV SÜD PSB Series
AFF Foam & Water Portable Fire Extinguishers
29
Stored Pressure Type - TÜV SÜD PSB Series
Carbon Dioxide Portable Fire Extinguishers
36 30
Mobile Fire
Extinguishers
Eversafe international Mobile Extinguisher
standards/directives Features
European Standard - BS EN 1866 Seamless steel CO� cylinder
PED (Pressure Equipment Direc�ve) Compact and ergonomic design
MED (Marine Equipment Direc�ve) Engineered for one man opera�on
Externally coated with epoxy polyester powder
Passed 480-hours salt spray test
Corrosion Resistant
Features
Reinforced synthe�c rubber hose
Cylinder is externally coated with Epoxy Marine Paint System
over sandblasted surface
Trolley wheels with stainless steel rim
Passed salt spray test for 720 hours, 1.5 �mes the usual test
period of 480 hours
Type Of Extinguishers
Dry Chemical Powder (ABC) Monnex Powder
AFFF C6 is synthe�c aqueous film forming The ideal agent for use on class B fires.
foam concentrate consists of specific It is non toxic, non conduc�ve and
fluorinated and hydrocarbon surfactants to non corrosive inert gas which works by
allow forma�on of an aqueous film on the smothering the flames and reducing the
surface of most hydrocarbon fuels, suppres- oxygen content of the air around fire.
sing vapour leaks and preven�ng its contact This agent also safe to use on live
with the oxygen and providing an excelling electrical fires.
sealing on hot surfaces. Its formula�on
allows a great oil repellence, fluidity and
burnback resistance.
31137 38
Stored Pressure Type Catridge Operated Type
Head Cap
& Lever
32
Stored Pressure Type / Cartridge Operated Type - MED Series
ABC Dry Powder Mobile Fire Extinguishers
33
Stored Pressure Type / Cartridge Operated Type - MED Series
AFF Foam Mobile Fire Extinguishers
34
Stored Pressure Type - MED Series
Carbon Dioxide Mobile Fire Extinguishers
MCO-10T
35
Stored Pressure Type / Cartridge Operated Type - KMCE Series
ABC Dry Mobile Portable Fire Extinguishers
0343
36
Stored Pressure Type / Cartridge Operated Type - KMCE Series
AFF Foam Mobile Portable Fire Extinguishers
0343
A IIIB A IIIB
37
Stored Pressure Type - KMCE Series
Carbon Dioxide Mobile Portable Fire Extinguishers
0343
38
Stored Pressure Type / Cartridge Operated Type - CR-KM Series
ABC Dry Mobile Portable Fire Extinguishers
39
Stored Pressure Type / Cartridge Operated Type - CR-KM Series
AFF Foam Mobile Portable Fire Extinguishers
40
Stored Pressure Type - CR-KM Series
Carbon Dioxide Mobile Portable Fire Extinguishers
41
Stored Pressure Type - DE Series
ABC Dry Mobile Portable Fire Extinguishers
42
Stored Pressure Type - DE Series
AFF Foam Mobile Portable Fire Extinguishers
43
Stored Pressure Type - DE Series
Carbon Dioxide Mobile Portable Fire Extinguishers
44
46
Foam Equipment (Concentrate) - DE Series
Mobile Foam Unit
FEATURES
45
Automatic Dry Powder - DE Series
Fire Extinguisher
Features
4648
Stored Pressure Type / Cartridge Operated Type - CR-DE Series
Monnex Dry Powder & AFF Foam Mobile Portable Fire Extinguishers
47
Stored Pressure Type - CR-DE Series
Carbon Dioxide Mobile Fire Extinguisher
CR-MCO-25 CR-MCO-25T
48
Fire Extinguishers Accessories
Covers, Stands and Brackets
Front View
Wall Brackets
Model WBT-01 WBL-01 WBL-02 WBL-03 WBL-04 WBL-05
Type ‘T’ Wall Brackets ‘L’ Wall Brackets
Applicable for Cartridge 2kg 3 kg 4 kg - 12 kg 5 kg CO2 6.8 kg CO2
Operated Type Dry Powder Dry Powder Dry Powder
& CO2
Material Chromed Steel
49
Fire Extinguishers Accessories
Brackets
Model
Wire Brackets
Model WB-03 WB-05 WB-07
Applicable for 1 kg 2 kg 2L
Dry Powder Dry Powder AFF Foam
Material Steel
33 50
Fire Extinguishers Accessories
Cartridges, Refills and Wrenches
CO Cartridge
Weight (g) External Applicable for
Coa�ng
35 EEK-6cs
55 PVC EEF-6cs, EEW-6cs, EEW-9cs, EEK-9cs
75 EEF-9cs, EEF-9c
Portable
75 Fire EED-4c
110 Ex�nguishers EED-6c
Epoxy
150 EED-9c, PES-9
225 EED-12c, EED-12cMX
550 Mobile MPG-25
1000 Epoxy Fire M FG-45, MPG-50
2000 Ex�nguishers M FG-135, M FG-150
Approval TPED
ABC Powder
EP4X Powder
Packaging 6kg, 9kg, 12kg and 25kg
Storage Cool and Dry Place
BC Powder
Monnex Powder
Packaging 25kg
Storage Cool and Dry Place
51
Fire Extinguishers Accessories
Cabinets & Extendable Telescopic Lance Applicator
Fibre Glass
Double Cabinet
EXTENDED LENGTH
1M
Item
1 Connector Brass
2 Ball Valve SS316
3 Insula�on Hand Grip Sponge (Rubber)
4 Outer Pipe Aluminium (Anodized)
5 Inner Pipe Aluminium (Anodized)
6 Circular Horn PPAV 161
52
Fire Hose Reel
Exclusive Products
CO2 Hose Reel Unit
Compare to conven�onal hose reel which carries water to ex�nguish fire.
CO� hose reel unit with galvanized steel/stainless steel material for the
drum improved its durability and strength. It has be�er reachability since
it use telescopic applicator to put out the fire.
53 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Swing Die Cast Swing Hose Inlet Fixed Pipe
Corrosion Resistant
Passed Salt Spray Test
UV Ageing Tested for 1000 hours Passed Unwinding Force Test
Passed Impact Test Pressure Tested to 1.5 Times Its
Solid & Durable Internal Drum Working Pressure
Smooth Rounded Surface Prevent
Cuts from Sharp Edges
Hose Reel Hose Reel
Disc Hose
In accordance to policy of continuous improvement, specifications are subject to change without notice. 54
Fire Hose Reels
Manual Swing Type Fire Hose Reels - Die Cast
A A D
B B LxW
C C
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
55
Fire Hose Reels
Manual Swing Type Fire Hose Reels - Hose Inlet
A A D
B B
LxW
C C
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
56
Fire Hose Reels
Manual Swing Type Fire Hose Reels - Fixed Pipe
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
57 60
Fire Hose Reels
Manual Swing Type Fire Hose Reels - Fixed Die Cast
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
58
Fire Hose Reels
Automatic Swing Type Fire Hose Reels - Hose Inlet
A A D
B B
LxW
C C
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
59
Fire Hose Reels
Automatic Swing Type Fire Hose Reels - Die Cast
A A D
B B LxW
C C
Note: 1. Various types of nozzle and hose length available upon request. Please refer to nozzle section for selection of nozzle
2. Horizontal bar hose reel available upon request
3. Ø 590mm disc available upon request
60
Fire Hose Reels
Continuous Flow Hose Reel - Mobile & Fixed Type
CHR-40MH CHR-40FH
61
Fire Hose Reels
CO Hose Reel Unit
Chromoly Steel
62
Fire Hose Reels
Accessories - Semi-Rigid Reel Hose & Nozzle
Jet Spray Nozzle Jet Spray Nozzle Jet Nozzle Lever Operated Nozzle Jet Spray Nozzle
Hose Nozzle
Model EZ-19P EZ-25P EZ-19 EZ-25 EZ-19J EZ-25J EZ-19LO EZ-25LO EZ-19OR
Inlet 19 mm 25 mm 19 mm 25 mm 19 mm 25 mm 19 mm 25 mm 19 mm
Body Material Nylon Brass
Finishing Red Chromed Plated
Working Pressure 12 bar
Test Pressure 18 bar
Flow Rate @ 6 bar Jet : 55L / min & Spray : 63L / min
Throw Range @ 2 bar Jet : > 10 m & Spray : > 3 m
63
Fire Hose Reels
Accessories - Valves
60 64
Fire Hose Reels
Accessories - Valves, Hose Guide & Nozzle Box
Ball Valve
Model BV-25A
Size DN 25
Inlet Size 1” BSPP
Outlet Size 1” BSPP
Pressure Nominal PN 16
Test Pressure 10 bar Gas Test
Body Material Brass Chromed
Nozzle Box
Model NZB-03
Body Material Aluminium Alloy
Type Wall Mounted
Glass Clear Glass
Finishing Red
65 68
Fire Hose Reels
Accessories - Hose Reel Cover & Cabinet
D
W
66
Fire Hydrant
Water Equipment
Water Equipment Fire Hydrant Fire Hoses
Landing Valve Pillar Hydrants Lay Flat Fire Hose
- Oblique, Right Angle & Nosed - 2 way, 3 way & 4 way Fire Hose Rack Assembly
Pressure Dry Barrel Hydrant Hydrant Nozzles
Breeching Inlet - With break system & - Jet & Spray
- 2 Way & 4 Way without break system Hose Cradle
Cabinet
Adaptors and Coupling
Water from the fire hydrant system can also be shared with other safety measures
such as automa�c fire sprinkler systems or fire hose reels.
Pillar fire hydrant and underground fire hydrant are a connec�on point outside the
building by which firefighters or fire engine can tap into a pressurized water supply.
67 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Landing Valves - Screw Type
In accordance to policy of continuous improvement, specifications are subject to change without notice. 7268
Fire Hydrant Equipment
Landing Valves - Flanged Type
73
69 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Breeching Inlet & Cabinets
In accordance to policy of continuous improvement, specifications are subject to change without notice. 70
Fire Hydrant Equipment
Fire Hydrants
71 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Dry Barrel Fire Hydrants
BS EN 14384:2005
Cert/LPCB ref.1280Ga
BS EN 14384:2005
Cert/LPCB ref.1280Ga
In accordance to policy of continuous improvement, specifications are subject to change without notice. 72
Fire Hydrant Equipment
Dry Barrel Fire Hydrants
BS EN 14384:2005
Cert/LPCB ref.1280Ga
BS EN 14384:2005
Cert/LPCB ref.1280Ga
73 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
3-Way Pillar Hydrant & 4-Way Pillar Hydrant
Model PH3T
Inlet Flange 150mm to Table 16/21 BS 4504 : 2
Outlet 2 x 2 1⁄2” BSP and 1 x 4” BSP Threaded Connectors
Working Pressure 16 bar
Test Pressure 24 bar
Finishing RAL 3000 Red Coa�ng
Designed & Manufactured to Factory Tested
In accordance to policy of continuous improvement, specifications are subject to change without notice. 74
Fire Hydrant Equipment
Hydrant Adaptors
Model CAH-MI
Body Material Brass
Head Size 1 1⁄2” BS 336 2 1⁄2” BS 336
Finishing Plain
75 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Hose Cradle & Hydrant Cabinet
680mm ± 10mm
155mm ± 5mm
Hose Cradle
Model HCD-01
Body Material Aluminium Alloy and Steel
Dimension (L x H x W) 680 mm x 155 mm x 180 mm
Movement 180° (le� to right)
Paint Finishing RAL 3000 Flame Red Epoxy Polyester Powder Coa�ng
D
W
In accordance to policy of continuous improvement, specifications are subject to change without notice. 80 76
Fire Hydrant Equipment
Lay Flat Fire Hoses
77 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Fire Hose Rack Assembly & Components
The Fire Hose Rack Assembly is used to provide immediate and efficient water
source for fire suppression, and permits one-man operation. The assembly is for occupants use,
Class II service under NFPA 14 standard class of service. The pin rack features an automatic
release mechanism where water flow through the hose after the last fold is released.
In accordance to policy of continuous improvement, specifications are subject to change without notice. 78
Fire Hydrant Equipment
Fire Hose Rack Assembly & Components
79 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Hydrant Equipment
Aluminum Jet Nozzle
In accordance to policy of continuous improvement, specifications are subject to change without notice. 80
Home & Vehicle
Fire Safety
Home Fire Safety Fire Blanket
3-in-1 Home Safety Kit 3 Sizes of Fire Blanket
- 1.2m x 1.2m
1kg Portable Dry Powder Fire Ex�nguisher - 1.2m x 1.8m
Fire Blanket - 1.5m x 1.8m
Smoke Alarm
81 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Home & Vehicle Safety
3-in-1 Home Safety Kit
User Friendly
Pressure Indicator
1 kg Fire Ex�nguisher
Controllable Discharge
Bracket Included
Fire Extinguisher
Model EC1
Type Stored Pressure ABC Dry Powder Type
Capacity 1 kg
Propellant Nitrogen
Valve Controllable Non Ferrous Valve With Pressure Indicator
Dimension (H) x (Ø) 325 mm x 78.5 mm
Approx Full Weight 1.7 kg
Working Temperature Pressure -20°C to + 60°C
Working / Test / Burst Pressure 12 bar/ 25 bar / >69 bar
Approximate Discharge Range 2m-3m
Approximate Discharge Time 9 sec
Fire Ra�ng 5A / 21B
Fire Class A, B, C + Electrical
Internal Coa�ng Stoving Epoxy Primer
Paint Finishing RAL 3000 Flame Red Epoxy Polyester Powder Coa�ng
Moun�ng Plas�c Bracket
Manufactured & Cer�fied to MS 1539 : 1
Fire Blanket
Model FB22SRC
Blanket Size 1.2 m x 1.2 m
Packing 256 mm x 160 mm 40 mm
Weight 1.1 kg
Material 100% Woven Fibre Glass in PVC Case
Flammability Non-Flammable
Surface Silica Coated
Temperature Range -20°C to 500°C
Resistance Oil, Grease, Fat, Acid, Alkali
Gas Permeability Low Gas Permeability
Designed & Manufactured to EN 1869
In accordance to policy of continuous improvement, specifications are subject to change without notice. 86 82
Home & Vehicle Safety
Fire Extinguishers - Vehicle
83 In accordance to policy of continuous improvement, specifications are subject to change without notice. 86
Home & Vehicle Safety
Fire Blankets, Smoke Alarm & LPG Detector
In accordance to policy of continuous improvement, specifications are subject to change without notice. 84
NAF S 125®, NAF S 227® & NAF S 1230®
Fire Extinguishing Systems
Certified Extinguishing NAF S 125® & 227® Systems
Systems Advantages
Comply with the requirement of NFPA 2001 Environmental friendly
UL Listed Zero Ozone Deple�on Poten�al
Validated Flow Calcula�on So�ware Low toxicity safe for human occupancy
UL approved by Bomba Malaysia & TNB Electrically non-conduc�ve to electrical equipment
No residue upon discharge
NAF S 1230® System Compact and minimal footprint
Our technicians are Retrotec cer�fied level 3 testers who are comfortable with performing
the enclosure integrity test, use Retrotec’s FanTes�c Integrity so�ware to evaluate peak
pressure, free vent area & etc., and also able to do larger and more complex tests.
Systems Comparison
NAF S 125® NAF S 227® NAF S 1230®
85 In accordance to policy of continuous improvement, specifications are subject to change without notice.
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
In accordance to policy of continuous improvement, specifications are subject to change without notice. 86
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
SH70025404
SH70027404
Part No. NAF S 1230 SHFKBCA075 SHFKBCA100 SHFKBCA120
100 litre
SHT V40 / V40IX*
1460 mm
358 mm
60 bar
87 In accordance to policy of continuous improvement, specifications are subject to change without notice.
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
60 bar
130 ± 10 bar* 95 ± 7 bar / 130 ± 10 bar*
* Only available for NAF S 1230®, 175 litre & 240 litre capacities
In accordance to policy of continuous improvement, specifications are subject to change without notice. 88
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
V20IX V25IX
89 In accordance to policy of continuous improvement, specifications are subject to change without notice.
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
V40IX V65IX
In accordance to policy of continuous improvement, specifications are subject to change without notice. 90
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
91 In accordance to policy of continuous improvement, specifications are subject to change without notice.
NAF S 125®, NAF S 227® & NAF S 1230® Fire Extinguishing Systems
Extinguishing System Components
180o & 360o Nozzles for NAF S 125® & NAF S 227®
In accordance to policy of continuous improvement, specifications are subject to change without notice. 92
IG-55, IG-100 & IG-541
Fire Extinguishing System
Inert Gas System IG-55: The perfect Combination
Approval & Certifications Blend of nitrogen and argon at a ra�on of 50:50. It combines
effec�ve ac�on against fire with the flexibility required for any
BSI ISO 9001 Quality Management Cer�fica�on func�onal need and hazard configura�on.
Cer�fied by Underwriters Laboratories (UL)
Listed in REACH Regula�on Annexes IV
Approved by BOMBA IG-100: Eco-Friendly & Versatile
VdS validated flow calcula�on so�ware
Use 100% nitrogen gas as an ex�nguishing agent for total
flooding of occupied and unoccupied rooms. This gas is the
main component of the atmosphere (78%) and is usually
found as N2, a very stable and non-reac�ve molecule.
Location
PERFLUOROKETONS
INERT GAS HALOCARBONS (HFC)
(FK-5-1-12)
Storage Form Gas Liquefied Compressed Gas Liquid
Low Footprint
High Pressure
Proximity of Cylinders Can be located Must be located within Must be located within
to Protected Space further away or very near to the space or very near to the space
to be protected to be protected
Environmental Effects
PERFLUOROKETONS
INERT GAS HALOCARBONS (HFC)
(FK-5-1-12)
93 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Inert Gas Fire Extinguishing System
Extinguishing System Components
Cylinder Valve Assembly
Working Pressure 200 bar 300 bar
Working Temperature -20oC to 50oC
Capacity 80L
Material Seamless Steel 34CrMo4
Approx. Diameter 279 mm 267 mm
Approx. Overall Height 1735 mm 1875 mm
Test Pressure 300 bar 450 bar
Finishing RAL 3000 Flame Red & RAL 6001 Green
Standard ISO 9809-1, ADR/RID, TPED 2010/35/EU ISO 9809-2, ADR/RID, TPED 2010/35/EU
Valve Model RGS-MAM-12-2C RGS-MAM-12-3C
Disc Burs�ng Pressure 270 bar 430 bar
Approval UL
Pressure Switch
Model POPRENC250 POPRENC300
Contact Types Normally Closed
Electrical Terminals Faston
Max. Voltage 48 V
Induc�ve Current 0.2A
Protec�on Index IP54
Pressure Se�ng 180 bar 266 bar
Approval UL
Cylinder Bracket
Type Single Row Double Row
Parts Nut & Bolt, Straps, Screw & Nut, Clamps, Horizontal
Rear Channel Rails, Threaded Rod
Material Steel
Approval UL
Bleed Valve
Model POVV8
Body Material Brass CuZn40Pb2
Ac�va�on Knob Material Aluminium
Approval UL
Pneumatic Fittings
Model 227TE 227CO
Type Tee Elbow
Material Brass CuZn39Pb3
Connec�on to Both Ends 1/4” BSP Male
Approval UL
Elbow Tee
In accordance to policy of continuous improvement, specifications are subject to change without notice. 94
Inert Gas Fire Extinguishing System
Extinguishing System Components
95 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Inert Gas Fire Extinguishing System
Extinguishing System Components
Discharge Nozzle
Model (360o) FEDR15 FEDR20 FEDR25 FEDR32 FEDR40 FEDR50 FEDR65
Model (180o) FEDR15180 FEDR20180 FEDR25180 FEDR32180 FEDR40180 FEDR50180 FEDR65180
Connec�on Thread 1/2” BSP 3/4” BSP 1” BSP 1 1/4” BSP 1 1/2” BSP 2” BSP 2 1/2” BSP
No. of Orifices 8 at 2 levels (360o) / 7 at 2 levels (180o)
Material Carbonated Steel
Max.Height 7.1m
Max. Coverage Area 13.2m x 13.2m
Approval UL
Pilot Cylinder
Medium Nitrogen
Cylinder Capacity 2 Litres
Working Presssure 100 bar
Approvals UL / FM
Electrical-manual Actuator
Model SIEX-SVS
Connec�on to Pipe 1/8” NPT Female
Material Brass
Approvals UL / FM
Selector Valve
Model SVD
Ball Valve Size DN20 - DN100
Actuator Pneuma�c Cylinder
Reset Manual
Connec�on Thread NPT / BSP Male / Welded
Approvals UL / FM
In accordance to policy of continuous improvement, specifications are subject to change without notice. 96
Carbon Dioxide
Fire Extinguishing System
How does CO2 System System
work? Advantages
Fire is suppressed by reducing the oxygen Environmental friendly
level in the protected area to the point where Colorless, odorless and electrically non-conduc�ve
combus�on cannot be sustained. Electrically non-conduc�ve to electrical equipment
No residue upon discharge
Cooling is a secondary ac�on of the agent Discharge under its own pressure
which is used in local applica�on where the Fast and efficient due to agent low boiling point
liquid phase of the discharge is applied directly to
the fire and hazard materials
Flexible Design
The system can be engineered to suit specific customer
requirements. Audible and visual indicators can be
integrated into the control system that facilitates
automa�c trigger of fire doors, dampers and shu�ers by
means of an electrical detec�on system.
97 In accordance to policy of continuous improvement, specifications are subject to change without notice.
CO Fire Extinguishing System
Extinguishing System Components
Pilot Cylinder
Cylinder Volume 3 Litre
Medium Nitrogen
Working Pressure @ 20°C 50 bar
Burst Disc Pressure 60 - 70 bar
Solenoid Valve Pressure 0 - 90 bar
Solenoid Valve Voltage 24V DC
Approvals Factory Manufacturing Standard
EE-209 EE-208
Solenoid Actuator
Type Direct Ac�ng
Size 1/4”
Control Mode Normally Close
Voltage 24V DC
Working Pressure 0 - 90 bar
Material Brass
Approvals Factory Manufacturing Standard
In accordance to policy of continuous improvement, specifications are subject to change without notice. 98
CO Fire Extinguishing System
Extinguishing System Components
Pilot T-Connection
Applica�on 100th Slave CO� Cylinder
Connec�on Ø 21.7 x 14 G
Material Hydraulic Steel
Finishing Rainbow Chromed
Approvals Factory Manufacturing Standard
Discharge Hose
Type High Pressure Hose
Size (Ø x L) 1/2” x 430 mm
Connec�on 3/4” BSPT Male / Ø 21.7 x 14 G Female Swivel
Working Pressure 160 bar
Test Pressure 310 bar
Material Wire Braided Reinforced Synthe�c Rubber
Hose Standard SAE 100 RIAT
99 In accordance to policy of continuous improvement, specifications are subject to change without notice.
CO Fire Extinguishing System
Extinguishing System Components
Manifold
Size Ø DN 20 - DN 80
Pipe Connec�on BSPT Male
Test Pressure 100 bar
Material Carbon Steel ASTM A-106 Grade B
Internal Coa�ng Galvanized
Finishing RAL 3000 Flame Red Epoxy Polyester Powder Coa�ng
Approvals Factory Manufacturing Standard
Bracket
Thickness 5 mm
Material Carbon Steel Flat Bar
Finishing RAL 3000 Flame Red Epoxy Polyester Powder Coa�ng
In accordance to policy of continuous improvement, specifications are subject to change without notice. 100
Amerex® Kitchen Protection
Fire Suppression System
Zone Defense
The KP Zone Defense adds
greater flexibility by allowing kitchen
appliances to be reconfigured without
having to move system discharge nozzles
as it covers the whole kitchen area.
101 In accordance to policy of continuous improvement, specifications are subject to change without notice.
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
Cylinder Assembly
Model KP275 KP375 KP475 KP600
Volume 2.75 gallons 3.75 gallons 4.75 gallons 6.00 gallons
Working Temperature, oC 0oC - 49oC
Working Pressure, psi 240 psi at 20oC
Test Pressure, psi 480 psi
Cylinder Material Steel
Valve Material Stainless Steel Brass
Test Standard DOT 4BW240
Approval UL
In accordance to policy of continuous improvement, specifications are subject to change without notice. 102
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
Linear Actuator
Part Number 24448
Working Temperature, oC -40oC to 70oC
Recommended Single Firing Current 1A
Actuator Body Material Brass
Piston Material Stainless Steel
Approval UL
Battery
Part Number 24903
Opera�ng Dura�on 6 months
Opera�ng Temperature 86oF (30oC)
Ba�ery shelf-life 10 Years
Approval UN/DOT
103 In accordance to policy of continuous improvement, specifications are subject to change without notice.
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
In accordance to policy of continuous improvement, specifications are subject to change without notice. 104
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
105 In accordance to policy of continuous improvement, specifications are subject to change without notice.
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
In accordance to policy of continuous improvement, specifications are subject to change without notice. 106
AMEREX Kitchen Protection Fire Supperesion System
Extinguishing System Components
Key Switch
Model KP-307
Size (W x L x H) 90 mm x 110 mm x 110 mm
Contact 0.5A (Max)
Material Mild Steel
Finishing Red Painted
Approvals Factory Manufacturing Standard
107 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Water Sprinkler
Fire Extinguishing System
Introduction
A fire sprinkler system is an automa�c fire protec�on The sprinkler head features different finishes,
system in a domes�c or commercial building which temperature ra�ngs and 2 types of temperature
discharge water to ex�nguish a fire when the sprinkler responses; either a standard response (5mm bulb)
head detects the fire through rising temperature. or a fast response (3mm bulb).
Though it is a system which is featured with both
the fire detec�on and suppression systems.
Conven�onal Suitable for most residen�al fire sprinkler systems, water is discharged
onto the ceiling
Upright & Aim all the water straight down and are suited to room with high
Pendent ceiling
Horizontal A�ach to a high point on the wall and usually give wider water coverage
Sidewall than conven�onal sprinkler head
In accordance to policy of continuous improvement, specifications are subject to change without notice. 108
Water Sprinkler
Water Sprinkler Head
109 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Water Sprinkler
Alarm Check Valve & Sprinkler Rosette
Sprinkler Rosette
Product Name Sprinkler Rose�e
Material Mild Steel
Finishing Chrome
Inner Diameter 21.8 mm
Outer Diameter 68 mm
Thickness 0.9 mm
In accordance to policy of continuous improvement, specifications are subject to change without notice. 110
Fire Alarm
Detection System
Fire Alarm System Initiating Devices
Consist of devices working together to detect Act as inputs to the fire alarm control unit and
any iden�fy a fire outbreak in a building, warn are either automa�cally ac�vated from smoke
occupants through visual and audio appliances. and heat detectors or manually ac�vated via
The main components of a fire a control unit, devices such as manual call points or pull sta�ons.
ini�a�ng devices and fire alarm no�fica�on
appliances.
Control Unit
The hub of fire alarm system, receives
informa�on from devices designed to
detect and report fires, monitors system opera�onal
integrity and controls outputs, and relays informa�on
necessary to prepare the facility for fire based on
a predetermined sequence.
Detection System
Installation Evacuate
Sign
Diagram Alarm
Bell
Twin Flashing
Light
Smoke
Alarm
Heat
Detector
Nozzle / Water
Sprinkler
111 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Alarm Detection System
Control Panel & Smoke Detector
Smoke Detector
Model VENATOR-DU (SHD90006) D-213-2 SOC-E3N
Opera�ng Voltage 9V - 33V DC 10.8V - 33V DC 12V - 30V DC
Features Equipped with Flashing LED
Finishing White
Approvals UL Listed EN 54-5 , UL Listed LPCB
In accordance to policy of continuous improvement, specifications are subject to change without notice. 112
Fire Alarm Detection System
Heat Detector & Alarm Bell
Heat Detector
Model VENATOR-DU (SH90007) KP-303 D-103 DCD-AE3
Type Fixed Temperature Conven�onal ROR & Fixed Temperature Conven�onal Fixed Temperature Conven�onal
Opera�ng Voltage 9 - 33V DC 6 - 28V DC 12 - 28V DC 9.5 - 30V DC
Rated Temperature 58°C (137°F) 57°C (135°F) 60°C (140°F)
Finishing White
Approvals UL Listed UL 521 / EN 54-5, CE UL 521 LPCB & VdS
113 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Alarm Detection System
Manual Pull Kit, Key Switch, Manual Pull & Call Station
Key Switch
Model KP-307
Size (W x L x H) 90 mm x 110 mm x 110 mm
Contact 0.5A (Max)
Material Mild Steel
Finishing Red Painted
Approvals Factory Manufacturing Standard
In accordance to policy of continuous improvement, specifications are subject to change without notice. 114
Fire Alarm Detection System
LED Evacuate Sign, Twin Flashing Light & Emergency Sign
115 In accordance to policy of continuous improvement, specifications are subject to change without notice.
Fire Alarm Detection System
Batteries & Surge Arrestors
SP1-24PKT-DC FRD-24
240PKT40 V20
In accordance to policy of continuous improvement, specifications are subject to change without notice. 116
Fire Alarm Detection System
Other Accessories
Tripping Device
Model TDS-24
Voltage 24V DC
Amp 300mA
Trip Load 10Kgs
Finishing Red Painted
Approvals Factory Manufacturing Standard
Fire Curtain
Material High Strength Non Combus�ble Fibre Glass Fabric
Size Custom Size Available Upon Request
117 In accordance to policy of continuous improvement, specifications are subject to change without notice.
NOW YOU CAN PURCHASE OUR EXTINGUISHERS ONLINE
WEBSTORE
SAY NO TO FIRE,
SAY YES TO FIRE SAFETY
SHOPEE
BIG OR SMALL,
FIRE SAFETY IS FOR
EVERYONE.
LAZADA
In accordance to policy of continuous improvement, specifications are subject to change without notice. 118