12/21/2022 | Page 1 of 6

Compressed Air Systems, Inc.


9303 Stannum StreetTampa, FL 33619-2658
Toll: 855.464.8525
Ph: 813.626.8177
Fx: 813.628.0187
Email: info@compressedairsystems.com

Item # IMT-PN 2250, 260.4 Nm³/h Capacity Nitrogen Gas Generator


Nitrogen generation with "pressure swing adsorption" Up to 99,9999% Web Price
(6.0)/1.0 ppm (Residual O2)
QUOTE
INMATEC OnTouch technology enables nitrogen to be supplied in a purity of
up to 6.0/1.0 ppm (residual oxygen) and quantities of 0.5 - 10,000 Nm³/h.

Compressed Air Specification | Ambient Conditions | Technical Dimensions


and Connections | Calculation of the Compressed Air Requirements |
Specifications | Special Design | Options | Process | Benefits | Additional
Information | Note

Compressed Air Specification

Temperature
+5 to +50 ºC
Range

ISO 8573.1, Class 1: Dirt and Oil, Class


Air Quality
4: Water

Pressure Dew Point +3 ºC

Ambient Conditions
12/21/2022 | Page 2 of 6

Ambient
Temperature +5 to +40 ºC
Range

Optional Ambient
Temperature -50 to +60 ºC
Range

Technical Dimensions and Connections

Maximum
11 bar
Operating Pressure

Voltage1 110 to 230 V

Power Supply 50 Hz
Frequency2 60 Hz

Noise Level 55 to 78 dBA

Calculation of the Compressed Air Requirements

95.00 %
97.00 %
98.00 %
99.00 %
Nitrogen Content 99.50 %
99.90 %
99.99 %
99.999 %
99.9999 %

Air Factor at
95.00% Nitrogen 1.9
Content

Air Factor at
97.00% Nitrogen 2.1
Content

Air Factor at
12/21/2022 | Page 3 of 6

98.00% Nitrogen 2.3


Content

Air Factor at
99.00% Nitrogen 2.5
Content

Air Factor at
99.50% Nitrogen 2.9
Content

Air Factor at
99.90% Nitrogen 3.9
Content

Air Factor at
99.99% Nitrogen 5.5
Content

Air Factor at
99.999% Nitrogen 8.0 to 10
Content

Air Factor at
99.9999% 10.0 to 12.0
Nitrogen Content

Specifications

Capacity at 95.00%
260.4 Nm³/h
Nitrogen Content

Capacity at 97.00%
215.3 Nm³/h
Nitrogen Content

Capacity at 98.00%
188.0 Nm³/h
Nitrogen Content

Capacity at 99.00%
Nitrogen Content, 2.0
Quality and 10.000 ppm 143.9 Nm³/h
Residual O2

Capacity at 99.50%
12/21/2022 | Page 4 of 6

Nitrogen Content, 2.5


Quality and 5.000 ppm 116.6 Nm³/h
Residual O2

Capacity at 99.90%
Nitrogen Content, 3.0
Quality and 1.000 ppm 73.4 Nm³/h
Residual O2

Capacity at 99.99%
Nitrogen Content, 4.0
Quality and 100 ppm 35.8 Nm³/h
Residual O2

Capacity at 99.999%
Nitrogen Content, 4.5
26.9 Nm³/h
Quality and 50 ppm
Residual O2

Capacity at 99.9999%
Nitrogen Content, 5.0
18.00 Nm³/h
Quality and 10 ppm
Residual O2

Industry
ISO 9001:2008
Standards/Certifications

Special Design

Material Stainless Steel

ASME
Protection Class3 Atex
IP 65

Options

Flow
Inlet pressure
Measured Values
Pressure dew point
Temperature
12/21/2022 | Page 5 of 6

GSM
Modbus
Interfaces
Profibus
VMC

Load change control


Modular extension
Availability
Recipe control
Redundant

System control
High Pressure
Up to 300 bar

Process

The production of high-purity to ultra-pure nitrogen is what makes


INMATEC PSA nitrogen generators stand out. In this process, the
clean compressed air flows through the adsorption containers. In
this pressure swing adsorption process, the high-quality activated
carbon binds the oxygen molecules, while the free nitrogen
molecules flow unhindered into the product tank. This production
process removes carbon dioxide molecules as well as oxygen
molecules. The dry and high-purity nitrogen can now be used in a
wide range of applications.

Benefits

Constant quality control is ensured by measuring nitrogen purity.


All measured values are recorded on our user-friendly INMATEC
touch control panel and can be monitored remotely from anywhere
in the world with internet access.

The effectiveness of the new technology promises savings from


the very first minute.

Low-maintenance valve technology and compact design are


further benefits in addition to the constant availability of high-
purity nitrogen.
12/21/2022 | Page 6 of 6

Additional Information

A multilingual touch control panel, remote control via PC and iPad,


long-term data storage and inlet and outlet filtration all come as
standard.

Note

Multiplying the nitrogen capacity by the air factor indicated below


gives the compressed air requirements.

Certified in accordance with ISO 9001:2008 and in accordance


with Pressure Equipment Directive 93/27/EC.

All Capacity values apply at 7 bar inlet pressure and 20 ºC


ambient temperature.

Technical dimensions and connections from PN 1550 dimensions


on request.

1 shock-proof plug