Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Technical Specifications (M1000 Controller) : Control Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Specifications (M1000 Controller)

Control Features
Battery & System Voltage Measurements Load / Battery Disconnect Control
Battery & Load Current Measurements Alarm Grouping for Relay Outputs
Battery Fuse & Mid Cell Monitoring User Settable Alarm Names for Auxiliary Inputs
Energy Calculations
Battery Functions
Battery Charge Profile Control Battery Charge Current Limiting
Battery Current Measurement Multiple Battery Support
Battery Temperature Measurement Battery Boost Charging (Auto / Manual)
Battery Temperature Compensation Battery Periodic Testing (Voltage / Time Set)
Battery Capacity Indication
Rectifiers
Supports Horizon (1.4KW, 2.7KW) / Quantum (3.0KW) Rectifier Efficiency Mode
and Centrix (5.6KW) series Rectifiers
Rectifier Input Voltage Rectifier Information like Serial No. & S/W Versions
Rectifier Current Measurements Alarm & Internal Temperature Monitoring
Rectifier Current Sharing
Alarms / Event Monitoring
Assigning severity of alarms (Critical / Major / Minor /
Info) Rectifier High Temperature
Logging of all alarms with Date and Time Stamp Rectifier Current Share
Battery Voltage Low / High Battery Test
Battery Temperature Low / High AC Mains Low / High
Battery Fuse Slave Device Communication
Rectifier Failure External Inputs
Rectifier Current Limit
General Data
Voltage 20V — 70V
Power Consumption 10W (Max)
Dimensions 130mm x 145 mm x 43 mm (WxDxH)
Storage Temperature Range -40°C to +85°C
Operating Temperature Range -20°C to +60°C
Analog Monitoring with External DC Interface Unit
Voltage Channels 6 Channels (Max)
Current Channels 7 Channels (Max)
Current Sensors Supported Hall Effect Sensors/ Shunt
Temperature Channels 3 Channels, -25°C to +100°C
Humidity Sensor (Optional) 2
Auxiliary Inputs & Outputs
Standard 2 Isolated Inputs & 2 Potential Free Outputs
With Additional Units Upto 64 Isolated Inputs & Potential Free outputs
External Alarm Monitoring External Inputs can be mapped as Alarms/ functions. Event Names are
User Settable. Can be used for SNMP Traps
System Interfaces
CAN V2.0b, 2 numbers, on RJ45 for communication with SMR and
System Control Bus
system units
2 x RS485 on RJ45
Serial Bus
1 x RS232 on D-Sub 9
Serial Protocols (Modbus RTU), Modem interface for remote monitoring
Interfaces
over GPRS/SMS using external GSM Modem
Technical Specifications (M1000 Controller)

System Configuration
Battery/Load LVD Control Up to 5
Battery Fuse Monitoring Auxiliary Inputs, Voltage Sensing
Support for Li-ion Battery Settable charge profiles and communication with battery BMS
Battery Testing Automatic Battery Monitoring and Periodic Test
User Interfaces
Display 65K Colour TFT, 1.8" / 5 key Control
10/ 100 MBPS BASE-T
Ethernet
Auto MDI/ MDI—X
SNMP V1, V2c
Networking HTTP, FTP, SNIP, DHCP (client), IPv4 & IPv6
USB USB 2.0
Storage
Event Storage Up to 10,000 events with time stamp
Parameter Logging Up to 10,000 user selectable (10 parameters) with Time Stamp
Energy & Run Hours Daily Logs for last 60 days
Change Logs Configuration setting changes with Time Stamp
Access All logs can be downloaded from HTTP interface

M1000 Mechanical Dimensions

Alarm Indications
Item Description
Green (1) System OK
Amber (1) Minor, Major and Critical Alarm
Red (2) Major Alarm
Red (3) Critical Alarm

Connector Details 4
Item Description
1 RS485 Communication Port
2 Power Port / CAN Comm Port
3 Power Port / CAN Comm Port (Optional)
4 RS485 Comm Port (Optional)
5 RS232 Communication Port
3 2 1 5

You might also like