KEY PLAN:

NORTH OF DWG.

-5.10

B19
FFL.

B43
SOG DRIVE WAY
250

B23
300 300

B7

B7
FIRE PUMP ROOM
250 250 -5.25 0003
FFL. 8100X8200
-5.10
150 FFL.

B17
TRUE NORTH

BASEMENT FLOOR
B3 B6 B16 B16 B6 B11 -5.25
FFL.

300 NOTES:
-4.60
-4.60
FFL.
1. ALL DIMENSIONS ARE IN MILLIMETERS,
FFL. FIRE TANK
FIRE TANK 0002 2. ALL LEVELS ARE IN METERS,

B42
0001
250 250

B20
3900X10400

B7
3900X10400

B21 0005
250 250

B3

B18
LOBBY
0029
250
PASSENGERS
ELEVATOR NO.3
B3 B11 B3 B11

B2
ELEC.ROOM
0006
VOID 0054
2750X2700

VOID
PAVEMENT
-5.10
250

TB2
FFL.

TB2

B41
250

B3
250 250
LEGEND:
VOID
WP WASTE DRAIN PIPE SLEEVE
GB2(300x600) B45 B46 B47 BLDG FFL QNHD
SP SOIL DRAIN PIPE SLEEVE

B58
VOID 800 SDP STORM DRAIN PIPE SLEEVE HEALTH
B41 B43
CENTER +9.450M
IDF ROOM
0052 PP PRESSURE PIPE SLEEVE MOSQUE +9.350M
2125X2900
WS WATER SUPPLY PIPE SLEEVE ANCILLARY
+9.450M
ELEC. ELECTRICAL SLEEVE BUILDING
FAN ROOM
0033
SLEEVE FOR FUEL TANK WATCHMAN 1 +9.050M
5550X9825
GUARD HOUSE +9.000M
400
ABBREVATIONS: AMBULANCE

TB1
GARAGE +9.420M
BOS BOTTOM OF SLEEVE WASTE
BOB BOTTOM OF BOX HOLDING +9.075M
WATCHMAN 2 +9.350M
750
850 800 750 IFC DRAWING REFERENCES
VOID
SL.NO. DRAWING TITLE DWG. NO.
1

2
3
STORM WATER TANK 4
0034
8200X7500 5

-4.60 6
FFL.
400 7

STATUS:
DRIVE WAY
-5.25
FFL.
0059
SHOP DRAWING
400
ACTION DATE SIGNATURE
A APPROVED
B APPROVED AS NOTED
C REVISE & RESUBMIT
D REJECTED

800 750

00 18.04.2019 SUBMITTAL FOR APPROVAL


REV. DATE ACTION CODE DESCRIPTION
400
PROJECT NAME:

SERVICE
0035
THREE(3)+TWO(2) HEALTH CENTERS
9300X13364
-5.10
FFL.
PACKAGE - 6
AL MESHAF HEALTH CENTER
400
-5.10
FFL. 750 TYPE B
750 750 750 750 750
CLIENT:

B70 WITH RAMP INV. B74 WITH RAMP INV. B74 WITH RAMP INV.
B69 WITH FLOOR
+B67 WITH FLOOR +B68 WITH FLOOR . +B68 WITH FLOOR
Building Affairs
B66 INV.

300 PAVEMENT
0058
VOID -5.10 FUEL TANK
ROOM
FUEL TANK
ROOM
FFL. -5.25 0053
0053
RAMP SLOPE 10% FFL. 3950X4700
3950X4700
-4.40
FFL.

CONSULTANT SUPERVISION:

ENGINEERING CONSULTANTS GROUP S.A.

MAIN CONTRACTOR:

BASEMENT FLOOR PLAN ZONE-1


SCALE 1:100

SUB CONTRACTOR: :

CO-ORDINATION OF MAIN AND SUB-CONTRACTORS


1 B1 K L CONTRACTOR
K L L BE B1 1 B1 1 B1 1 TRADE SIGN DATE
G H J L L NAME COMPANY
H
STR. WORK DENNIS BALBUENA ITCC
ARCH. FINISHES ARCH.MIJO MATHEW ITCC
PL. & FF ENG.ULLAS UDAYAN ITCC
HVAC ENG.ULLAS UDAYAN ITCC
ELECTRICAL ENG.VIJITH ITCC
ALUM. WORK
-1.100 -1.100 LANDSCAPE
-1.100 -1.100 -1.100 -1.100 -1.100 -1.100

CO-ORDINATOR ENG.RENE ITCC

TECH. MANAGER

DRAWING TITLE:

MEP BUILDERS WORK OF BASEMENT


BASEMENT FLOOR FFL-4.40 BASEMENT FLOOR FFL-4.40 RETAINING WALL LAYOUT ZONE-1
BASEMENT FLOOR FFL-4.60
BASEMENT FLOOR FFL-5.25 BASEMENT FLOOR FFL-5.25 FFL-5.25 (SHEET-1 OF 1)
BASEMENT FLOOR FFL-5.10 FFL-5.25 ELEVATION-6 ELEVATION-7 FFL-5.25 BASEMENT FLOOR FFL-5.25 FFL-5.25 DRAWN BY CHECKED BY DATE SCALE REV.

ELEVATION-1 ELEVATION-2 ELEVATION-3 ELEVATION-4 ELEVATION-5 ELEVATION-8 ELEVATION-9 ELEVATION-10 APRIL-2019 AS SHOWN
DWG. No.
MHCP6-ITCC-SHD-MD-DT-0001 00
SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS SCALE NTS TRANSMITTAL NO. DATE PROJ. MANAGER SIGNATURE