LR22550383TA MergedAppendix

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Page 1 of 2

Certificate No: LR22550383TA


Issue Date: 05/06/2023
Expiry Date: 04/06/2028

Type Approval Certificate

This is to certify that the undernoted product(s) has/have been tested with satisfactory results in accordance with
the relevant requirements of the Lloyd's Register Type Approval System.

Manufacturer ABB SpA


Address Via Vittor Pisani, 16, Milano, MI, 20124, Italy

Place of Production ABB Industrial Solutions (Klodzko) Sp. z o.o.

Ul. Pilsudskiego 5, Klodzko, 57-300, Poland

Type Circuit Breakers (Env Tested)

Description Residual Current Circuit Breaker with Overcurrent Protection

Trade Name DS202CR

Application Marine/Offshore/Industrial applications in environmental categories ENV1,


ENV2, ENV3 and ENV4 as detailed in Lloyd's Register Type Approval System -
Test Specification Number 1, December 2021.

Specified Standard IEC 61009-1:2010+A1:2012+A2:2013;


IEC 61009-2-1:1991.

Ratings See Appendix.

Additional Tests The circuit breakers have been tested against low temperature to -25 °C, and
are suitable for the environmental category ENV5 if installed in an enclosure
which is separately tested against salt mist and degrees of protection provided
(minimum IP56).

Matteo Roiaz
Electrotechnical Systems Specialist to Lloyd's
71 Fenchurch Street, London, EC3M 4BS, United Register EMEA
Kingdom A member of the Lloyd's Register group

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively,
referred to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or
expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the
relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms
and conditions set out in that contract.

TA01 2.0
Page 2 of 2
Certificate No: LR22550383TA
Issue Date: 05/06/2023
Expiry Date: 04/06/2028

Type Approval Certificate

This certificate is not valid for equipment, the design, ratings or operating parameters of which have been varied
from the specimen tested. The manufacturer should notify Lloyd's Register EMEA of any modification or changes to
the equipment in order to obtain a valid Certificate.

The Design Appraisal Document LR22550383DA and its supplementary Type Approval Terms and Conditions form
part of this Certificate.

71 Fenchurch Street, London, EC3M 4BS, United


Kingdom

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively,
referred to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or
expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the
relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms
and conditions set out in that contract.

TA01 2.0
APPENDIX to Certificate no. LR22550383TA

Ratings:

number of poles : 2P
rated voltage (Un) : 110 V / 230 V
nature of supply : AC
rated frequency : 50 Hz and 50/60 Hz
rated current (In) : 6 up to 40 A
range of instantaneous tripping overcurrent (curve) : B, C
rated residual current (Idn) : 10 up to 300 mA
residual current type : A
rated residual marking and breaking capacity (Idm) : 3000 A according EN 61009-1
1500 A according IEC 61009-1
rated short-circuit current (Icn) : 4500 A / 6000 A / 10000 A
energy limiting class : 3
safety distance ‘a’ : 60 mm for types rated Icn=10000 A, In=40 A
35 mm for all other types
method of operation : independent of the line
method of mounting : distribution board
terminals : screw terminal
rated ambient temperature (ta) : -25 °C to +40 °C
protection against electric shock : IP 20

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually
and collectively, referred to in this clause as 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to
any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever
provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information
or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

You might also like