ACCUTRAK™ ROTARY POSITION MONITORS

FLAMEPROOF - ATEX/IEC

Rotary position monitors certified to Exd Flameproof and specifically engineered for
hazardous environments. Available with a range of position sensors and switches

FEATURES

• Flameproof design meeting a wide range of


worldwide approvals.
• Touch set cams are hand adjustable, spring
loaded and self-locking providing quick
calibration of position switches and sensors.
• Strong durable BeaconTM offers 360º visual
indication in a choice of styles and colors.
• Terminal strips are pre-wired and numbered
with generous working space for ease of use.
• Additional conduit for easy field wiring and
mounting accessories as standard.
• Wide range of switches and sensors.
• Position transmitter option.
• Switch stabilisation plate.
• Standardized mounting pattern for easy
adaptation to common bracketry.
• Range of drive shaft options.
• Aluminum enclosures with ultra-low copper
content (0.2% maximum) ensure robust
performance in corrosive environments.
• Rugged stainless steel enclosures.
• IP rated plugs certified where applicable.

TECHNICAL DATA GENERAL APPLICATION

Agency approvals AccuTrak position monitors are ideal for


Area classification (ATEX/IEC) manual and automated rotary valves. They
2200 series Ex II 2 GD provide consistent and accurate valve
Ex db IIB+H2 T* Gb monitoring in a compact unit which can be
2600 series Ex II 2 GD mounted directly or via a valve actuator.
Ex db IIC T* Gb
Ex tb IIIC T*°C Db
Enclosure standards (IEC)
All enclosures IP66/67
Switches
All models V3 SPDT mechanical switches
DPDT mechanical switches
V3 inductive proximity sensors
Magnum SPDT (hermetically sealed proximity type) switches
Enclosures
All models Aluminum
Stainless steel CF8M (316)

www.westlockcontrols.com TD10054-ENrA Page 1 of 6


Copyright © Westlock Controls. All rights reserved.
ACCUTRAK™ ROTARY POSITION MONITORS
FLAMEPROOF - ATEX/IEC

2200 SERIES ENCLOSURE DIMENSIONS

DIM. A &
COVER REMOVAL
HEIGHT CONDUIT
LOCATION A

CONDUIT 9.51
LOCATION B [.375] 6.48
6.30 13.31 [.255]
[.248] [.524]

DIM B

32.39
[1.275]
HOUSING DIMENSIONS
COVER TYPE DIM. A COVER REMOVAL HEIGHT 8.89
[.350]
HI COVER 211.1 [8.31] 332.3 [13.08]
STD. COVER 157.8 [6.21] 247.2 [9.73] DIM C 3.91
57.2
FLAT COVER 88.4 [3.48] 111.3 [4.38] [.154] 9.51
[2.25]
SQ. [.375]

4.85
35.36 4X 5/16-18 [ .191]
4X M6X1-6H [1.392]
SQ.

3.99
[.157]

Dimensions in mm, imperial dimensions (inches) in parenthesis

TECHNICAL SPECIFICATIONS
Materials of construction
Enclosure Aluminum with powder coat finish
Stainless steel with electropolished finish
Temp. range -30°C to +85°C (Flat cover -20°C to +85°C)
Shaft and hardware Stainless steel
Bushing Oil impregnated bronze (aluminum enclosure)
PTFE (stainless steel enclosure)
Beacon visual indicator Co-polyester
Drive shaft
Westlock standard Double-D with ¼” A/F
NAMUR standard NAMUR standard VDI/VDE 3845
Available switches
V3 SPDT mechanical switches
DPDT mechanical switches
V3 inductive proximity sensors
Magnum SPDT (hermetically sealed proximity type) switches

NOTES
1. See selection guide for standard conduit entries
2. See switches and sensors data sheet for further information
3. Please consult your sales office for any other requirements

www.westlockcontrols.com TD10054-ENrA Page 2 of 6


Copyright © Westlock Controls. All rights reserved.
ACCUTRAK™ROTARY POSITION MONITORS
FLAMEPROOF - ATEX/IEC

2600 SERIES ENCLOSURE DIMENSIONS

CONDUIT
CONDUIT LOCATION C
LOCATION B 130.3
@ 30° [5.13]
COVER REMOVAL
HEIGHT 152.7
[6.01]
3X
57.35 CONDUIT
[2.258] LOCATION A
@ 30°

8.16 6.45
[.321] 13.75 [.254]
6.50 [.542]
[.256]

132.2
[5.21]

33.02
[1.300]

3.89 8.89
[.153] [.350]
28.58 8.14
[1.125] [.320]

57.15
166.7 [2.250]
[6.56]
SQ.

4.85
9.51
[ .191]
[ .375]

4X 3.38
M8 x 1.25 [.133] 3.99
[.157]

SHAFT DETAIL
NAMUR OUTPUT

Dimensions in mm, imperial dimensions (inches) in parenthesis

TECHNICAL SPECIFICATIONS
Materials of construction
Enclosure Aluminum with powder coat finish
Stainless steel with electropolished finish
Temp. range -60°C to +110°C
Shaft and hardware Stainless steel with electropolished finish
Bushing Oil impregnated bronze (aluminum enclosure)
PTFE (stainless steel enclosure)
Beacon visual indicator Co-polyester
Drive shaft
Westlock standard Double-D with ¼” A/F
NAMUR standard NAMUR standard VDI/VDE 3845
Available switches
V3 SPDT mechanical switches
DPDT mechanical switches
V3 inductive proximity sensors
Magnum SPDT (hermetically sealed proximity type) switches

NOTES
1. See selection guide for standard conduit entries
2. See switches & sensors data sheet for further information
3. Please consult your sales office for any other requirements

www.westlockcontrols.com TD10054-ENrA Page 3 of 6


Copyright © Westlock Controls. All rights reserved.
ACCUTRAK™ ROTARY POSITION MONITORS
2200 SERIES SELECTION GUIDE

Housing
22 2200 with flanged lid
Cover style
4 With Beacon visual indication
6 No visual indication
Switch type
5 Microswitch SPDT contacts
6 Microswitch DPDT contacts
7 V3 Inductive sensor
9 Magnum proximity switch
0 No switches fitted
Material
A Aluminum
S Stainless steel
Beacon type and color
B1 BM3-1 pattern 90°
BY Black/Yellow
B3 BM3-3 pattern 90°
AR ANSI Red/White
B5 BM3-5 pattern 90°
GR Green/Red
B7 BM3-7 pattern 180°
00 No Beacon fitted
B9 BM3-9 pattern 180°
Drive shaft type
S Westlock standard - ¼” A/F (6.32 mm)
N NAMUR standard shaft - VDI/VDE 3845
* Non-standard (consult sales office)
Ancillary options
000 No ancillary options
0DS 4-20 mA Digital Signal Position Transmitter (available with switch types 5, 7 and 9 only)
Switch/sensor quantity
0 No switch/sensor fitted
2 Two switches/sensors
4 Four switches/sensors
6 Six switches/sensors (consult sales office)
Conduit entries supplied
2 Two entries - standard
4 Four entries (consult sales office)
Unit specification
AAA Standard build- M20 conduit entries
ADZ 3/4 ” NPT conduit entries
EIS 2 x 3/4 NPT + 2 x 1/2 NPT
*** Non-standard material (consult sales office)
Certification
A ATEX & IECEx
* Other options (consult sales office)
Revision

R* Internal revision #
22 4 9 S GR S 000 2 2 AAA A R3 = Model number 2249SGRS00022AAA-AR3

NOTES
1. Please contact your sales office for guidance on selecting the best possible combination for your control and monitoring requirements.
2. See Hazardous area classification technical bulletin for further information on global standards.

www.westlockcontrols.com TD10054-ENrA Page 4 of 6


Copyright © Westlock Controls. All rights reserved.
ACCUTRAK™ ROTARY POSITION MONITORS
2600 SERIES SELECTION GUIDE

Housing
26 2600 with screw lid
Cover style
4 With Beacon visual indication
6 No visual indication
Switch type
5 Microswitch SPDT contacts
6 Microswitch DPDT contacts
7 V3 Inductive sensor
9 Magnum proximity switch
0 No switches fitted
Material
A Aluminum
S Stainless steel
Beacon type and color
B1 BM3-1 pattern 90°
BY Black/Yellow
B3 BM3-3 pattern 90°
AR ANSI Red/White
B5 BM3-5 pattern 90°
GR Green/Red
B7 BM3-7 pattern 180°
00 No Beacon fitted
B9 BM3-9 pattern 180°
Drive shaft type
S Westlock standard - ¼” A/F (6.32 mm)
N NAMUR standard shaft - VDI/VDE 3845
* Non-standard (consult sales office)
Ancillary options
000 No ancillary options
0DS 4-20 mA Digital Signal Position Transmitter (availale with switch types 5, 7, and 9 only)
Switch/sensor quantity
0 No switch/sensor fitted
2 Two switches/sensors
4 Four switches/sensors (consult sales office)
Conduit entries supplied
2 Two entries - standard
3 Three entries
4 Four entries (consult sales office)
Unit specification
AAA Standard build- M20 conduit entries
ADZ 3/4” NPT conduit entries
* * * Non-standard material (consult sales office)
Certification
A ATEX & IECEx
* Other options (consult sales office)
Revision

R* Internal revision #
26 4 9 S BY N 000 2 2 AAA A R2 = Model number 2649SBYN00022AAA-AR2

NOTES
1. Please contact your sales office for guidance on selecting the best possible combination for your control and monitoring requirements.
2. See Hazardous area classification technical bulletin for further information on global standards.

www.westlockcontrols.com TD10054-ENrA Page 5 of 6


Copyright © Westlock Controls. All rights reserved.
Translations
Where translated the copy is taken from the original English document TD10054-EN as checked
by the relevant notified certification body and therefore the original English document will prevail.
No rights or liability can be derived from any translation.

Crane Co., and its subsidiaries cannot accept responsibility for possible errors in catalogues, brochures, other prinited materials,
and website information. Crane Co. reserves the right to alter its products without notice, including products already on order
provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarkts in
®
this material are the property of Crane Co. ot its subsidiaties. The Crane and Crane brands logotype (WESTLOCK CONTROLS
) are
registered trademarks of Crane Co. All rights reserved.

WESTLOCK CONTROLS
Head Office USA EUROPE ASIA
280 N. Midland Avevnue, Ste. 258 +1 201 794 7650 +44 (0)1892 516277 +65 6266 4535
Saddle Brook, NJ 07663
United States

www.westlockcontrols.com TD10054-ENrA Page 6 of 6


Copyright © Westlock Controls. All rights reserved.

You might also like