MF BN 180 AUE 10 E 2.

x
TECHNICAL DATA
Part number 1250064
Pmax * 8 bar
Qmax * 180 l/min
Connection G 1¼
Cartridge conn. type UN thread
Material Aluminium, steel sheet
Seal material NBR
Bypass valve 1.7 bar
Temperature range * -30 °C to 100 °C
Weight w ith element [kg] 2,8

SPARE ELEMENT(S)
Designation 0180 MA 010 BN
Number elem.(s)/side 1
Filter material Betamicron®, Dpmax=20 bar (air breathers and SpinOns)
Filter rating (acc. to ISO 16889) 10.4 µm at βx(c) = 200
Cont. retention cap. (acc. to ISO 16889) 127.5 g at 2.0 bar
Differential pressure stability * 8 bar
Slope coefficient 0.0011 bar / (l/min)

CLOGGING INDICATOR(S)
Designation VMF 16 E.x
Part number 305450
CI response pressure 16.0 bar
Pressure gauge, connection on the back (absolute pres-
Design
sure)
Measurement of Back-pressure
Pmax * 11 bar

DIMENSIONS
Installation space of filter (without indicator)
Clogging Indicator
Element

Creator: Tayrone Kvint HYDAC Filtertechnik GmbH - Filter-IT² 1.0 – 23.11.2020


Company: *) Exceeding the mentioned and approved technical values can lead to malfunctions or destruction of the product.
Project: HYDAC dimensioning recommendations: We recommend a filter selection at a differential pressure of 20% of the response pressur e of the clogging indicator. 1/2
MF BN 180 AUE 10 E 2.x

CHARACTERISTICS
Pressure / Flow Pressure / Temperature

Total: Housing: Element(s):

OPERATING CONDITIONS FOR THE FILTER


Medium ISO VG 46 (mineral oil) Δp at 50 l/m in
Selecting temperature 40 °C Total 0.116 bar
Selecting viscosity 43.70 mm²/s Element(s) 0.080 bar
Cold Start Viscosity -
Flow 50 l/min

SPARE PARTS LIST


Part num- Num-
Pos. Spare Parts Designation
ber ber
1 Filter element(s) per side - 0180 MA 010 BN 1
2 Clogging indicator 305450 VMF 16 E.x 1

Creator: Tayrone Kvint HYDAC Filtertechnik GmbH - Filter-IT² 1.0 – 23.11.2020


Company: T he information in this brochure relates to the operating conditions and applications described. For applications or operatin g conditions not described, please
Project: contact the relevant technical department. Subject to technical modifications. 2/2
HYDAC dimensioning recommendations: We recommend a filter selection at a differential pressure of 20% of the response pressure of the clogging indicator.