Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

FT-2000 Menu Mode

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

MENU MODE

The Menu system of the FT-2000 provides extensive customization capability, so you can set up your transceiver just the
way you want to operate it. The Menu items are grouped by general utilization category, and are numbered from “001
001 AGc
DLY” to “149
FST DLY 149 tGEn EMRGNCY
EMRGNCY.”

USING THE MENU


1. Press the [MENU] button momentarily, to engage the [CLEAR] Button

Menu mode.
The Main (VFO-A) frequency display will show the
Menu Number and Menu Group name, while the Sub
(VFO-B) frequency display will show the Menu item;
the Multi-Display window shows the current setting of
the currently-selected Menu item.
2. Rotate the Main Tuning Dial knob to select the Menu
item you wish to work on. [MENU] Button

3. Rotate the [SUB VFO-B] knob to change the current Main Tuning Dial Knob [SUB VFO-B] Knob

setting of the selected Menu item.


ADVICE:
Menu Number Menu Group Name Menu Item
Press the [CLEAR] button momentarily to reset the
selected Menu item to the factory default value.
4. When you have finished making your adjustments,
press and hold in the [MENU] button for two seconds
to save the new setting and exit to normal operation. If
you only momentarily press the [MENU] button, the Menu Setting
new settings will not be retained.

Menu Mode Reset


You may reset all the Menu settings to their original factory defaults, if desired.
1. Turn the front panel [POWER] switch off.
2. Press and hold in the [MENU] button, and while holding it in, press the [POWER] switch to turn the transceiver
back on. Now release the [MENU] button.

Page 108 FT-2000 OPERATING MANUAL


MENU MODE
GROUP NO. MENU FUNCTION AVAILABLE VALUES DEFAULT SETTING
AGC 001 AGc FST DLY 20 ~ 4000 msec (20 msec/step) 300 msec
AGC 002 AGc FST HLD 0 ~ 2000 msec (20 msec/step) 20 msec
AGC 003 AGc MID DLY 20 ~ 4000 msec (20 msec/step) 700 msec
AGC 004 AGc MID HLD 0 ~ 2000 msec (20 msec/step) 20 msec
AGC 005 AGc SLW DLY 20 ~ 4000 msec (20 msec/step) 2000 msec
AGC 006 AGc SLW HLD 0 ~ 2000 msec (20 msec/step) 20 msec
DISPLAY 007 diSP COLOR bL1 / bL2 / bL3 / ub1 / ub2 bL1Ú1
DISPLAY 008 diSP DIM MTR 0 ~ 15 7
DISPLAY 009 diSP DIM VFD 0~7 4
DISPLAY 010 diSP BAR SEL CLAr / C-tn / u-tn C-tn
DISPLAY 011 diSP PK HLD OFF / 0.5 / 1.0 / 2.0 sec OFF
DISPLAY 012 diSP RTR STU 0 / 90 / 180 / 270° 0°
DISPLAY 013 diSP RTR ADJ –30° ~ 0° (2°/step) 0°
DISPLAY 014 diSP QMB MKR On / OFF OnÚ1
DISPLAY 015 diSP LVL IND PI / SP / CO / nO / dn / Cd / Ud / rP / nG / Pr / ––
SH / UI
DVS 016 dUS RX LVL 0 ~ 100 50
DVS 017 dUS TX LVL 0 ~ 100 50
KEYER 018 tEy BEACON OFF / 1 ~ 255 sec OFF
KEYER 019 tEy NUM STL 1290 / AunO / Aunt / A2nO / A2nt / 12nO / 12nt 1290
KEYER 020 tEy CONTEST 1 ~ 9999 1
KEYER 021 tEy CW MEM1 tyP1 / tyP2 tyP2
KEYER 022 tEy CW MEM2 tyP1 / tyP2 tyP2
KEYER 023 tEy CW MEM3 tyP1 / tyP2 tyP2
KEYER 024 tEy CW MEM4 tyP1 / tyP2 tyP2
KEYER 025 tEy CW MEM5 tyP1 / tyP2 tyP2Ú2
GENERAL 026 GEnE ANT SEL bAnd / rEG bAnd
GENERAL 027 GEnE BEP LVL 0 ~ 100 50
GENERAL 028 GEnE CAT BPS 4800 / 9600 / 192H (19200) / 384H (38400) bps 4800 bps
GENERAL 029 GEnE CAT TOT 10 / 100 / 1000 / 3000 msec 10 msec
GENERAL 030 GEnE CAT RTS On / OFF On
GENERAL 031 GEnE CAT IND On / OFF On
GENERAL 032 GEnE MEM GRP On / OFF OFF
GENERAL 033 GEnE Q SPLIT –20 ~ 0 ~ +20 kHz (1 kHz/step) +5 kHz
GENERAL 034 GEnE TRACK OFF / bAnd / FrEq OFF
GENERAL 035 GEnE TX TOT OFF / 3 / 5 / 10 / 15 / 20 / 30 min OFF
GENERAL 036 GEnE TRV SET 30 ~ 49 MHz 44 MHz
GENERAL 037 GEnE μT DIAL StP1 / StP2 / OFF StP1
GENERAL 038 GEnE SNB LVL nAin (MAIN) / 0~100 nAin(MAIN)
GENERAL 039 GEnE SUB FIL 1200 / 500 / 300 Hz 1200 Hz
GENERAL 040 GEnE MIC SCN On / OFF On
GENERAL 041 GEnE SCN RSM CAr / 5Sec 5SEc
GENERAL 042 GEnE ANTIVOX 0 ~ 100 50
GENERAL 043 GEnE FRQ ADJ –25 ~ 0 ~ +25 0
S IF SFT 044 S-iF LSB SFT –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 045 S-iF USB SFT –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 046 S-iF CWL SFT –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 047 S-iF CWU SFT –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 048 S-iF RTTY –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 049 S-iF RTTY-R –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 050 S-iF PKT-LSB –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
S IF SFT 051 S-iF PKT-USB –1000 ~ +1000 Hz (20 Hz/step) 0 Hz
MODE-AM 052 A3E MICGAIN Ur (VR) / 0 ~ 100 30
MODE-AM 053 A3E MIC SEL Frnt / dAtA / PC Frnt
Ú1: Requires optional DMU-2000 Data Management Unit.
Ú2: Requires optional FH-2 Remote Control Keypad.

FT-2000 OPERATING MANUAL Page 109


MENU MODE
GROUP NO. MENU FUNCTION AVAILABLE VALUES DEFAULT SETTING
MODE-CW 054 A1A F-TYPE OFF / buG / ELE / ACS ELE
MODE-CW 055 A1A F-REV nor / rEU (REV) nor
MODE-CW 056 A1A R-TYPE OFF / buG / ELE / ACS ELE
MODE-CW 057 A1A R-REV nor / rEU (REV) nor
MODE-CW 058 A1A CW AUTO OFF / 50 / On OFF
MODE-CW 059 A1A BFO USb / LSb / Auto USb
MODE-CW 060 A1A BK-IN SEni (SEMI) / FuLL SEni (SEMI)
MODE-CW 061 A1A SHAPE 1 / 2 / 4 / 6 msec 4 msec
MODE-CW 062 A1A WEIGHT (1:) 2.5 ~ 4.5 3.0
MODE-CW 063 A1A FRQDISP dir / OFSt OFSt
MODE-CW 064 A1A PC KYNG EnA (Enable) / diS (Disable) diS (Disable)
MODE-CW 065 A1A QSKTIME 15 / 20 / 25 / 30 msec 15 msec
MODE-DAT 066 dAtA DATA IN dAtA / PC dAtA
MODE-DAT 067 dAtA DT GAIN 0 ~ 100 50
MODE-DAT 068 dAtA DT OUT nAin (Main) / Sub nAin (Main)
MODE-DAT 069 dAtA OUT LVL 0 ~ 100 50
MODE-DAT 070 dAtA VOX DLY 30 ~ 3000 msec 300 msec
MODE-DAT 071 dAtA V GAIN 0 ~ 100 50
MODE-DAT 072 dAtA PKTDISP –3000 ~ +3000 Hz (10 Hz/step) 0 Hz
MODE-DAT 073 dAtA PKT SFT –3000 ~ +3000 Hz (10 Hz/step) 1000 Hz
MODE-FM 074 F3E MICGAIN Ur (VR) / 0 ~ 100 50
MODE-FM 075 F3E MIC SEL Frnt / dAtA / PC Frnt
MODE-FM 076 F3E 28 RPT 0 ~ 1000 kHz (10 kHz/step) 100 kHz
MODE-FM 077 F3E 50 RPT 0 ~ 4000 kHz (10 kHz/step) 1000 kHz
MODE-RTY 078 rtty R PLRTY nor / rEU (REV) nor
MODE-RTY 079 rtty T PLRTY nor / rEU (REV) nor
MODE-RTY 080 rtty RTY OUT nAin (Main) / Sub nAin (Main)
MODE-RTY 081 rtty OUT LEL 0 ~ 100 50
MODE-RTY 082 rtty SHIFT 170 / 200 / 425 / 850 Hz 170 Hz
MODE-RTY 083 rtty TONE 1275 / 2125 Hz 2125 Hz
MODE-SSB 084 J3E MIC SEL Frnt / dAtA / PC Frnt
MODE-SSB 085 J3E TX BPF 1-30 / 1-29 / 2-28 / 3-27 / 4-26 / 3000 3-27
MODE-SSB 086 J3E LSB CAR –200 Hz ~ +200 Hz (10 Hz/step) 0 Hz
MODE-SSB 087 J3E USB CAR –200 Hz ~ +200 Hz (10 Hz/step) 0 Hz
MODE-SSB 088 J3E SLSB CR –200 Hz ~ +200 Hz (10 Hz/step) 0 Hz
MODE-SSB 089 J3E SUSB CR –200 Hz ~ +200 Hz (10 Hz/step) 0 Hz
RX AUDIO 090 rout AGC SLP nor / SLP nor
RX AUDIO 091 rout HEADPHN SEP / Con1 / Con2 SEP
RX DSP 092 rdSP CNTR LV –40 ~ +20 dB –15 dB
RX DSP 093 rdSP CNTR WI 1 – 11 10
RX DSP 094 rdSP NOTCH W nArr (Narrow) / uuid (Wide) uuid (Wide)
RX DSP 095 rdSP CW SHAP SOFt / ShAP ShAP
RX DSP 096 rdSP CW SLP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) nEd (MEDIUM)
RX DSP 097 rdSP CW NARR 25 / 50 / 100 / 200 / 300 / 400 / 500 / 800 / 500 Hz
1200 / 1400 / 1700 / 2000 Hz
RX DSP 098 rdSP PKT SHP SOFt / ShAP ShAP
RX DSP 099 rdSP PKT SLP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) nEd (MEDIUM)
RX DSP 100 rdSP PKT NAR 25 / 50 / 100 / 200 / 300 / 400 Hz 300 Hz
RX DSP 101 rdSP RTY SHP SOFt / ShAP ShAP
RX DSP 102 rdSP RTY SLP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) nEd (MEDIUM)
RX DSP 103 rdSP RTY NAR 25 / 50 / 100 / 200 / 300 / 400 Hz 300 Hz
RX DSP 104 rdSP SSB SHP SOFt / ShAP ShAP
RX DSP 105 rdSP SSB SLP StP(STEEP) / nEd(MEDIUM) / GEnt(GENTLE) nEd (MEDIUM)
RX DSP 106 rdSP SSB NAR 200 / 400 / 600 / 850 / 1100 / 1350 / 1500 / 1800 Hz
1650 / 1800 / 1950 / 2100 / 2250 Hz

Page 110 FT-2000 OPERATING MANUAL


MENU MODE
GROUP NO. MENU FUNCTION AVAILABLE VALUES DEFAULT SETTING
SCOPE 107 SCP 1.8 FIX 1.800 - 1.999 MHz (1 kHz/step) 1.800 MHzÚ1
SCOPE 108 SCP 3.5 FIX 3.500 - 3.999 MHz (1 kHz/step) 3.500 MHzÚ1
SCOPE 109 SCP 5.0 FIX 5.250 - 5.499 MHz (1 kHz/step) 5.250 MHzÚ1
SCOPE 110 SCP 7.0 FIX 7.000 - 7.299 MHz (1 kHz/step) 7.000 MHzÚ1
SCOPE 111 SCP 10.1 FIX (1)0.100 - (1)0.149 MHz (1 kHz/step) (1)0.100 MHzÚ1
SCOPE 112 SCP 14.0 FIX (1)4.000 - (1)4.349 MHz (1 kHz/step) (1)4.000 MHzÚ1
SCOPE 113 SCP 18.0 FIX (1)8.000 - (1)8.199 MHz (1 kHz/step) (1)8.068 MHzÚ1
SCOPE 114 SCP 21.0 FIX (2)1.000 - (2)1.449 MHz (1 kHz/step) (2)1.000 MHzÚ1
SCOPE 115 SCP 24.8 FIX (2)4.800 - (2)4.989 MHz (1 kHz/step) (2)4.890 MHzÚ1
SCOPE 116 SCP 28.0 FIX (2)8.000 - (2)9.699 MHz (1 kHz/step) (2)8.000 MHzÚ1
SCOPE 117 SCP 50.0 FIX (5)0.000 - (5)3.999 MHz (1 kHz/step) (5)0.000 MHzÚ1
TUNING 118 tun DIALSTEP 1 / 5 / 10 Hz 10 Hz
TUNING 119 tun CW FINE EnA / diS diS
TUNING 120 tun MHz SEL 1 / 0.1 MHz 1 MHz
TUNING 121 tun AM STEP 2.5 / 5 / 9 / 10 / 12.5 kHz 5 kHz
TUNING 122 tun FM STEP 5 / 6.25 / 10 / 12.5 / 20 / 25 kHz 5 kHz
TUNING 123 tun FM DIAL 10 / 100 Hz 100 Hz
TUNING 124 tun MY BAND 1.8 ~ 50 / GE / AU ––
TX AUDIO 125 tAUd EQ1 FRQ OFF / 100 ~ 700 Hz (100 Hz/step) OFF
TX AUDIO 126 tAUd EQ1 LVL –20 ~ +10 +5
TX AUDIO 127 tAUd EQ1 BW 1 ~ 10 10
TX AUDIO 128 tAUd EQ2 FRQ OFF / 700 ~ 1500 Hz (100 Hz/step) OFF
TX AUDIO 129 tAUd EQ2 LVL –20 ~ +10 +5
TX AUDIO 130 tAUd EQ2 BW 1 ~ 10 10
TX AUDIO 131 tAUd EQ3 FRQ OFF / 1500 ~ 3200 Hz (100 Hz/step) OFF
TX AUDIO 132 tAUd EQ3 LVL –20 ~ +10 +5
TX AUDIO 133 tAUd EQ3 BW 1 ~ 10 10
TX AUDIO 134 tAUd PE1 FRQ OFF / 100 ~ 700 Hz (100 Hz/step) 200 Hz
TX AUDIO 135 tAUd PE1 LVL –20 ~ +10 0
TX AUDIO 136 tAUd PE1 BW 1 ~ 10 2
TX AUDIO 137 tAUd PE2 FRQ OFF / 700 ~ 1500 Hz (100 Hz/step) 800 Hz
TX AUDIO 138 tAUd PE2 LVL –20 ~ +10 0
TX AUDIO 139 tAUd PE2 BW 1 ~ 10 1
TX AUDIO 140 tAUd PE3 FRQ OFF / 1500 ~ 3200 Hz (100 Hz/step) 2100 Hz
TX AUDIO 141 tAUd PE3 LVL –20 ~ +10 0
TX AUDIO 142 tAUd PE3 BW 1 ~ 10 1
TX GNRL 143 tGEn BIAS –– ––Ú2
TX GNRL 144 tGEn MAX PWR 10 / 20 / 50 / 100 W 100 W
TX GNRL 145 tGEn PWRCTRL ALL / Car ALL
TX GNRL 146 tGEn ETX-GND EnA (ENABLE) / diS (DISABLE) diS (DISABLE)
TX GNRL 147 tGEn TUN PWR 10 / 20 / 50 / 100 W 100 W
TX GNRL 148 tGEn VOX SEL nic (MIC) / dAtA nic (MIC)
TX GNRL 149 tGEn EMRGNCY EnA (ENABLE) / diS (DISABLE) diS (DISABLE)
Ú1: Requires optional DMU-2000 Data Management Unit.
Ú2: This Menu item does not work. Please do not change this setting.

FT-2000 OPERATING MANUAL Page 111


MENU MODE
AGC GROUP DISPLAY GROUP
001 AGc FST DLY 007 diSP COLOR
Function: Sets the delay time for the AGC FAST mode of Function: Selects the Display color when the optional Data
the Main band (VFO-A) receiver. Management Unit (DMU-2000) is connected.
Available Values: 20 ~ 4000 msec (20 msec/step) Available Values: bL1 / bL2 / bL3 / ub1 / ub2
Default Setting: 300 msec bL1: COOL BLUE
bL2: CONTRAST BLUE
002 AGc FST HLD
bL3: FLASH WHITE
Function: Sets the hang time of the AGC peak voltage for
ub1: CONTRAST UMBER
the AGC FAST mode of the Main band (VFO-A) receiver.
ub2: UMBER
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: bL1 (COOL BLUE)
Default Setting: 20 msec
ADVICE:
003 AGc MID DLY If the optional DMU-2000 Data Management Unit is not
Function: Sets the delay time for the AGC MID mode of connected, this adjustment has no effect.
the Main band (VFO-A) receiver.
008 diSP DIM MTR
Available Values: 20 ~ 4000 msec (20 msec/step)
Function: Setting of the meter brightness level when
Default Setting: 700 msec
“DIM” is selected.
004 AGc MID HLD Available Values: 0 ~ 15
Function: Sets the hang time of the AGC peak voltage for Default Setting: 7
the AGC MID mode of the Main band (VFO-A) receiver.
009 diSP DIM VFD
Available Values: 0 ~ 2000 msec (20 msec/step)
Function: Setting of the frequency display brightness level
Default Setting: 20 msec
when “DIM” is selected.
005 AGc SLW DLY Available Values: 0 ~ 7
Function: Sets the delay time for the AGC SLOW mode of Default Setting: 4
the Main band (VFO-A) receiver.
010 diSP BAR SEL
Available Values: 20 ~ 4000 msec (20 msec/step)
Function: Selects one of three parameters to be viewed
Default Setting: 2000 msec
on the Tuning Offset Indicator.
006 AGc SLW HLD Available Values: CLAr / C-tn / u-tn
Function: Sets the hang time of the AGC peak voltage for Default Setting: C-tn
the AGC SLOW mode of the Main band (VFO-A) receiver. CLAr: Displays relative clarifier offset.
Available Values: 0 ~ 2000 msec (20 msec/step) C-tu: Displays relative CW tuning offset between the
Default Setting: 20 msec incoming signal and transmitted frequency.
u-tn: Displays the peak position of the VRF or μ-
TUNE filter.
NOTE:
The μ-TUNE filter is an option.
011 diSP PK HLD
Function: Selects the peak hold time of the Sub (VFO-B)
receiver’s S-meter.
Available Values: OFF / 0.5 / 1.0 / 2.0 sec
Default Setting: OFF
012 diSP RTR STU
Function: Selects the starting point of your rotator
controller’s indicator needle.
Available Values: 0 / 90 / 180 / 270°
Default Setting: 0°
013 diSP RTR ADJ
Function: Adjusts the indicator needle precisely to the
starting point set in menu item “012 diSP RTR STU.”
Available Values: –30 ~ 0°
Default Setting: 0°

Page 112 FT-2000 OPERATING MANUAL


MENU MODE
DISPLAY GROUP KEYER GROUP
014 diSP QMB MKR 018 tEy BEACON
Function: Enables/Disables the QMB Marker (White ar- Function: Sets the interval time between repeats of the
row “V”) to display on the Spectrum Band Scope when beacon message.
the optional DMU-2000 Data Management Unit is con- Available Values: OFF / 1 ~ 255 sec
nected. Default Setting: OFF
Available Values: On / OFF
Default Setting: On 019 tEy NUM STL
ADVICE: Function: Selects the Contest Number “Cut” format for
If the optional DMU-2000 Data Management Unit is not an imbedded contest number.
connected, this adjustment has no effect. Available Values: 1290 / AunO / Aunt / A2nO / A2nt /
12nO / 12nt
015 diSP LVL IND Default Setting: 1290
Function: Enables/Disables the Sub band (VFO-B) fre- 1290: Does not abbreviate the Contest Number
quency display to show each frequency or value while each AunO: Abbreviates to “A” for “One,” “U” for “Two,”
of the enabled knob is turned. “N” for “Nine,” and “O” for “Zero.”
Available Values: PI (PITCH) / SP (SPEED) / CO (CON- Aunt: Abbreviates to “A” for “One,” “U” for “Two,”
TOUR) / nO (NOTCH) / dn (DNR) / Cd (CW DELAY) / “N” for “Nine,” and “T” for “Zero.”
Ud (VOX DEALAY) / rP (RF POWER) / nG (MIC GAIN) / A2nO: Abbreviates to “A” for “One,” “N” for “Nine,”
Pr (PROCESSOR GAIN) / SH (IF SHIFT) / UI (IF and “O” for “Zero.”
WIDTH) A2nt: Abbreviates to “A” for “One,” “N” for “Nine,”
To disable the “function,” rotate the [SUB VFO-B] knob and “T” for “Zero.”
to recall the “function” to be disabled, then press the [ENT] 12nO: Abbreviates to “N” for “Nine,” and “O” for
key to change this setting to “OFF” (a “E E ” notation will “Zero.”
replace the “d d” notation). Repeat the same procedures to 12nt: Abbreviates to “N” for “Nine,” and “T” for
enable a function (setting it to “ON” (“E E ” notation ap- “Zero.”
pears)”).
020 tEy CONTEST
Function: Enters the initial contest number that will in-
DVS GROUP crement/decrement after sending during contest QSOs.
Available Values: 1 ~ 9999
016 dUS RX LVL
Default Setting: 1
Function: Sets the audio output level from the voice
ADVICE:
memory.
Press the [CLEAR] button to reset the contest number to
Available Values: 0 ~ 100
“1.”
Default: 50
021 tEy CW MEM1
017 dUS TX LVL
Function: Permits entry of the CW message for message
Function: Sets the microphone input level to the voice
register 1.
memory
Available Values: tyP1 / tyP2
Available Values: 0 ~ 100
Default Setting: tyP2
Default: 50
tyP1: You may enter the CW message from the front
panel’s Function Keys.
tyP2: You may enter the CW message from the CW
keyer.
022 tEy CW MEM2
Function: Permits entry of the CW message for message
register 2.
Available Values: tyP1 / tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the front
panel’s Function Keys.
tyP2: You may enter the CW message from the CW
keyer.

FT-2000 OPERATING MANUAL Page 113


MENU MODE
KEYER GROUP GENERAL GROUP
023 tEy CW MEM3 026 GEnE ANT SEL
Function: Permits entry of the CW message for message Function: Sets the method of antenna selection.
register 3. Available Values: bAnd / rEG
Available Values: tyP1 / tyP2 Default Setting: bAnd
Default Setting: tyP2 bAnd:The antenna is selected in accordance with the
tyP1: You may enter the CW message from the front operating band.
panel’s Function Keys. rEG: The antenna is selected in accordance with the
tyP2: You may enter the CW message from the CW band stack (different antennas may be utilized
keyer. on the same band, if so selected in the band
024 tEy CW MEM4 stack).
Function: Permits entry of the CW message for message 027 GEnE BEP LVL
register 4. Function: Sets the beep level.
Available Values: tyP1 / tyP2 Available Values: 0 ~ 100
Default Setting: tyP2 Default Setting: 50
tyP1: You may enter the CW message from the front
panel’s Function Keys. 028 GEnE CAT BPS
tyP2: You may enter the CW message from the CW Function: Sets the transceiver’s computer-interface cir-
keyer. cuitry for the CAT baud rate to be used.
Available Values: 4800 / 9600 / 192H(19200) /
025 tEy CW MEM5 384H (38400) bps
Function: Permits entry of the CW message for message Default Setting: 4800 bps
register 5.
Available Values: tyP1 / tyP2 029 GEnE CAT TOT
Default Setting: tyP2 Function: Sets the Time-Out Timer countdown time for a
tyP1: You may enter the CW message from the front CAT command input.
panel’s Function Keys. Available Values: 10 / 100 / 1000 / 3000 msec
tyP2: You may enter the CW message from the CW Default Setting: 10 msec
keyer. The Time-Out Timer shuts off the CAT data input after the
ADVICE: continuous transmission of the programmed time.
If the optional FH-2 Remote Control Keypad is not con- 030 GEnE CAT RTS
nected, this adjustment has no effect. Function: Enables/Disables the RTS port of the CAT jack.
Available Values: On/OFF
Default Setting: On
031 GEnE CAT IND
Function: Enables/Disables the flashing of the Data LED
inside the [CS] switch in conjunction with the CAT com-
mands.
Available Values: On / OFF
Default Setting: On
032 GEnE MEM GRP
Function: Enables/Disables Memory Group Operation.
Available Values: On / OFF
Default Setting: OFF
033 GEnE Q SPLIT
Function: Selects the tuning offset for the Quick Split fea-
ture.
Available Values: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz

Page 114 FT-2000 OPERATING MANUAL


MENU MODE
GENERAL GROUP
034 GEnE TRACK 038 GEnE SNB LVL
Function: Sets the VFO Tracking feature. Function: Adjusts the Sub band (VFO-B) receiver’s IF
Available Values: OFF / bAND / FrEq Noise Blanker level, when the Noise Blanker is engaged.
Default Setting: OFF Available Values: nAin(MAIN) / 0~100
OFF: Disables the VFO Tracking feature. Default Setting: nAin(MAIN)
bAND: When you change bands on the Main (VFO- When this menu is set to “nAin(MAIN),” you may adjust
A) side, the Sub (VFO-B) band’s VFO will the Noise Blanker level using the front panel’s [NB] knob.
automatically change to be the same as that of
039 GEnE SUB FIL
VFO-A.
Function: Defines the Sub band (VFO-B) receiver’s CW
FrEq: This function is the almost same as “bAND,”
narrow filter.
however, furthermore, the Sub band’s (VFO-
Available Values: 1200 / 500 / 300 Hz
B) frequency changes together with the Main
Default Setting: 1200 Hz
Band’s (VFO-A) frequency when turning the
ADVICE:
Main Dial Tuning knob.
This Menu item tells the microprocessor which (if any)
035 GEnE TX TOT optional filter has been installed.
Function: Sets the Time-Out Timer countdown time.
040 GEnE MIC SCN
Available Values: OFF / 3 / 5 / 10 / 15 / 20 / 30 min
Function: Enables/disables scanning access via the
Default Setting: OFF
microphone’s [UP]/[DWN] keys.
The Time-Out Timer shuts off the transmitter after con-
Available Values: On / OFF
tinuous transmission of the programmed time.
Default Setting: On
036 GEnE TRV SET
041 GEnE SCN RSM
Function: Sets the 10’s and 1’s of the MHz digits display
Function: Selects the Scan Resume mode.
for operation with a transverter.
Available Values: CAr / 5SEc
Available Values: 30 ~ 49 MHz
Default Setting: 5SEc
Default Setting: 44 MHz
CAr: The scanner will hold until the signal disappears,
The default setting would be used with a 144 MHz
then will resume after one second.
transverter. If you connect a 430 MHz transverter to the
5SEc: The scanner will hold for five seconds, then re-
radio, set this menu to “30” (the “100 MHz” digits are
sume whether or not the other station is still
hidden on this radio).
transmitting.
037 GEnE μT DIAL
042 GEnE ANTIVOX
Function: Selects the μ-TUNE mode.
Function: Adjusts the Anti-VOX Trip Gain which is the
Available Values: StP1 / StP2 / OFF
level of negative feedback of receiver audio to the micro-
Default Setting: StP1
phone, to prevent receiver audio from activating the trans-
StP1: A c t i v a t e s t h e μ - T U N E s y s t e m u s i n g
mitter (via the microphone) during VOX operation.
“COARSE” steps of the [VRF] knob (2 steps/
Available Values: 0 ~ 100
click) on the 7 MHz and lower amateur bands.
Default Setting: 50
On the 10/14 MHz bands, “FINE” [VRF] knob
steps (1 step/click) will be used. 043 GEnE FRQ ADJ
StP2: Activates the μ-TUNE system using “FINE” Function: Adjusts the reference oscillator.
steps of the [VRF] knob (1 step/click) on the Available Values: –25 ~ 0 ~ +25
14 MHz and lower amateur bands on the Main Default Setting: 0
band (VFO-A). Connect a 50-Ohm dummy load and frequency counter to
OFF: Disables the μ-TUNE system. Activates the the antenna jack; adjust the [SUB VFO-B] knob so that
VRF feature on the 14 MHz and lower amateur the frequency counter reading is same as the VFO fre-
bands on the main band (VFO-A). quency while pressing the PTT switch.
ADVICE: ADVICE:
If the optional RF μTuning Kit is not connected, this ad- Do not perform this Menu item unless you have a high-
justment has no effect. performance frequency counter. Perform this Menu item
after aging the transceiver and frequency counter suffi-
ciently (at least 30 minutes).

FT-2000 OPERATING MANUAL Page 115


MENU MODE
S IF SFT (SUB BAND IF SHIFT) GROUP MODE-AM GROUP
044 S-iF LSB SFT 052 A3E MICGAIN
Function: Sets the center frequency of the Sub band (VFO- Function: Sets the microphone gain for the AM mode.
B) receiver’s IF filter in the LSB mode. Available Values: Ur (VR) / 0 ~ 100
Available Values: –1000 ~ +1000 Hz (20Hz/step) Default Setting: 30
Default Setting: 0 Hz When this menu is set to “Ur (VR),” you may adjust the
microphone gain using the front panel’s [MIC] knob.
045 S-iF USB SFT
Function: Sets the center frequency of the Sub band (VFO- 053 A3E MIC SEL
B) receiver’s IF filter in the USB mode. Function: Selects the microphone to be used on the AM
Available Values: –1000 ~ +1000 Hz (20Hz/step) mode.
Default Setting: 0 Hz Available Values: Frnt / dAtA / PC
Default Setting: Frnt
046 S-iF CWL SFT
Frnt: Selects the microphone connected to the front
Function: Sets the center frequency of the Sub band (VFO-
panel’s MIC jack while using the AM mode.
B) receiver’s IF filter in the CW (LSB) mode.
dAtA: Selects the microphone connected to pin 1 of
Available Values: –1000 ~ +1000 Hz (20Hz/step)
the PACKET Jack while using the AM mode.
Default Setting: 0 Hz
PC: This parameter is for future expansion of this
047 S-iF CWU SFT transceiver’s capabilities, but at this time is not
Function: Sets the center frequency of the Sub band (VFO- supported.
B) receiver’s IF filter in the CW (USB) mode.
Available Values: –1000 ~ +1000 Hz (20Hz/step)
Default Setting: 0 Hz
048 S-iF RTTY
Function: Sets the center frequency of the Sub band (VFO-
B) receiver’s IF filter in the RTTY mode.
Available Values: –1000 ~ +1000 Hz (20Hz/step)
Default Setting: 0 Hz
049 S-iF RTTY-R
Function: Sets the center frequency of the Sub band (VFO-
B) receiver’s IF filter in the RTTY reverse mode.
Available Values: –1000 ~ +1000 Hz (20Hz/step)
Default Setting: 0 Hz
050 S-iF PKT-LSB
Function: Sets the center frequency of the Sub band (VFO-
B) receiver’s IF filter in the Packet (LSB) mode.
Available Values: –1000 ~ +1000 Hz (20Hz/step)
Default Setting: 0 Hz
051 S-iF PKT-USB
Function: Sets the center frequency of the Sub band (VFO-
B) receiver’s IF filter in the Packet (USB) mode.
Available Values: –1000 ~ +1000 Hz (20Hz/step)
Default Setting: 0 Hz

Page 116 FT-2000 OPERATING MANUAL


MENU MODE
MODE-CW GROUP
054 A1A F-TYPE 058 A1A CW AUTO
Function: Selects the desired keyer operation mode for Function: Enables/disables CW keying while operating
the device connected to the front panel’s KEY jack. on SSB.
Available Values: OFF / buG / ELE / ACS Available Values: OFF / 50 / On
Default Setting: ELE Default Setting: OFF
OFF: Disables the front panel’s keyer (“straight key” OFF: Disables CW keying while operating on SSB.
mode for use with external keyer or computer- 50: Enables CW keying only while operating SSB
driven keying interface). on 50 MHz (but not HF).
buG: Mechanical “bug” keyer emulation. One paddle On: Enables CW keying while operating on SSB (all
produces “dits” automatically, while the other TX bands).
paddle manually produces “dahs.” NOTE:
ELE: Iambic keyer with ACS (Automatic Character This feature allows you to move someone from SSB to
Spacing) disabled. CW without having to change modes on the front panel.
ACS: Iambic keyer with ACS (Automatic Character
059 A1A BFO
Spacing) enabled.
Function: Sets the CW carrier oscillator injection side for
055 A1A F-REV the CW mode.
Function: Selects the keyer paddle’s wiring configuration Available Values: USb / LSb / Auto
for the KEY jack on the front panel. Default Setting: USb
Available Values: nor / rEU (REV) USb: Injects the CW carrier oscillator on the USB side.
Default Setting: nor LSb: Injects the CW carrier oscillator on the LSB side.
nor: Tip = Dot, Ring = Dash, Shaft = Ground Auto: Injects the CW carrier oscillator on the LSB side
rEU (REV): Tip = Dash, Ring = Dot, Shaft = Ground while operating on the 7 MHz band and below,
and the USB side while operating on the 10 MHz
056 A1A R-TYPE
band and up.
Function: Selects the desired keyer operation mode for
the device connected to the rear panel’s KEY jack. 060 A1A BK-IN
Available Values: OFF / buG / ELE / ACS Function: Sets the CW “break-in” mode.
Default Setting: ELE Available Values: SEni / FuLL
OFF: Disables the rear panel’s keyer (“straight key” Default Setting: SEni
mode for use with external keyer or computer- SEni (SEMI): The transceiver will operate in the semi
driven keying interface). break-in mode. The delay (receiver re-
buG: Mechanical “bug” keyer emulation. One paddle covery) time is set by the front panel’s
produces “dits” automatically, while the other [DELAY] knob.
paddle manually produces “dahs.” FuLL: The transceiver will operate in the full
ELE: Iambic keyer with ACS (Automatic Character break-in (QSK) mode.
Spacing) disabled.
061 A1A SHAPE
ACS: Iambic keyer with ACS (Automatic Character
Function: Selects the CW carrier wave-form shape (rise/
Spacing) enabled.
fall times).
057 A1A R-REV Available Values: 1 / 2 / 4 / 6 msec
Function: Selects the keyer paddle’s wiring configuration Default Setting: 4 msec
for the KEY jack on the rear panel.
062 A1A WEIGHT
Available Values: nor / rEU (REV)
Function: Sets the Dot:Dash ratio for the built-in elec-
Default Setting: nor
tronic keyer.
nor: Tip = Dot, Ring = Dash, Shaft = Ground
Available Values: (1:) 2.5 ~ 4.5
rEU (REV): Tip = Dash, Ring = Dot, Shaft = Ground
Default Setting: 3.0

FT-2000 OPERATING MANUAL Page 117


MENU MODE
MODE-CW GROUP MODE-DAT GROUP
063 A1A FRQDISP 066 dAtA DATA IN
Function: Selects the frequency Display Format for the Function: Selects the data input path to be used on the
CW mode. PKT mode.
Available Values: dir / OFSt Available Values: dAtA / PC
Default Setting: OFSt Default Setting: dAtA
dir (Direct Frequency): Displays the receiver carrier dAtA:Uses the data input line connected to pin 1 of
frequency, without any offset the PACKET jack while using the PKT mode.
added. When changing PC: This parameter is for future expansion of this
modes between SSB and CW, transceiver’s capabilities, but at this time is not
the frequency display re- supported.
mains constant.
067 dAtA DT GAIN
OFSt (Pitch Offset): This frequency display re-
Function: Sets the data input level from the TNC to the
flects the added BFO offset.
AFSK modulator.
064 A1A PC KYNG Available Values: 0 ~ 100
Function: Enables/disables CW keying from the Default Setting: 50
“PACKET PTT” terminal (pin 3) on the rear panel’s
068 dAtA DT OUT
PACKET jack while operating on the CW mode.
Function: Selects the receiver to be connected to the data
Available Values: EnA (Enable) / diS (Disable)
output port (pin 4) of the PACKET jack.
Default Setting: diS (Disable)
Available Values: nAin (Main) / Sub
065 A1A QSKTIME Default Setting: nAin (Main)
Function: Selects the time delay between when the PTT
069 dAtA OUT LVL
is keyed and the carrier is transmitted during QSK opera-
Function: Sets the AFSK data output level at the output
tion when using the internal keyer.
port (pin 4) of the PACKET jack.
Available Values: 15 / 20 / 25 / 30 msec
Available Values: 0 ~ 100
Default Setting: 15 msec
Default Setting: 50
070 dAtA VOX DLY
Function: Adjusts the “VOX” delay (receiver recovery)
time on the PKT mode.
Available Values: 30 ~ 3000 msec
Default Setting: 300 msec
071 dAtA V GAIN
Function: Adjusts the “VOX” gain on the PKT mode.
Available Values: 0 ~ 100
Default Setting: 50
072 dAtA PKTDISP
Function: Sets the packet frequency display offset.
Available: –3000 ~ +3000 Hz (10 Hz/step)
Default: 0 Hz
073 dAtA PKT SFT
Function: Sets the carrier point during the SSB packet
operation.
Available: –3000 ~ +3000 Hz (10 Hz/step)
Default: 1000 Hz (typical center frequency for PSK31,
etc.)

Page 118 FT-2000 OPERATING MANUAL


MENU MODE
MODE-FM GROUP MODE-RTY GROUP
074 F3E MICGAIN 078 rtty R PLRTY
Function: Sets the microphone gain for the FM mode. Function: Selects normal or reverse Mark/Space polarity
Available Values: Ur (VR) / 0 ~ 100 for RTTY receive operation.
Default Setting: 50 Available Values: nor / rEU (REV)
When this menu is set to “Ur (VR),” you may adjust the Default Setting: nor
microphone gain using the front panel’s [MIC] knob.
079 rtty T PLRTY
075 F3E MIC SEL Function: Selects normal or reverse Mark/Space polarity
Function: Selects the microphone to be used on the FM for RTTY transmit operation.
mode. Available Values: nor / rEU (REV)
Available Values: Frnt / dAtA / PC Default Setting: nor
Default Setting: Frnt
080 rtty RTY OUT
Frnt (FRONT): Selects the microphone connected to
Function: Selects the receiver to be connected to the data
the front panel’s MIC jack while us-
output port (pin 2) of the RTTY jack.
ing the FM mode.
Available Values: nAin (Main) / Sub
dAtA: Selects the microphone connected to
Default Setting: nAin (Main)
pin 1 of the PACKET Jack while us-
ing the FM mode. 081 rtty OUT LEL
PC: This parameter is for future expansion Function: Sets the FSK RTTY data output level at the
of this transceiver’s capabilities, but output port (pin 2) of the RTTY jack.
at this time is not supported. Available Values: 0 ~ 100
Default Setting: 50
076 F3E 28 RPT
Function: Sets the magnitude of the repeater shift on the 082 rtty SHIFT
28 MHz band. Function: Selects the frequency shift for FSK RTTY op-
Available Values: 0 ~ 1000 kHz (10 kHz/step) eration.
Default Setting: 100 kHz Available Values:170 / 200 / 425 / 850 Hz
Default Setting: 170 Hz
077 F3E 50 RPT
Function: Sets the magnitude of the repeater shift on the 083 rtty TONE
50 MHz band. Function: Selects the Mark tone for RTTY operation.
Available Values: 0 ~ 4000 kHz (10 kHz/step) Available Values: 1275 / 2125 Hz
Default Setting: 1000 kHz Default Setting: 2125 Hz

FT-2000 OPERATING MANUAL Page 119


MENU MODE
MODE-SSB GROUP RX AUDIO GROUP
084 J3E MIC SEL 090 rout AGC SLP
Function: Selects the microphone to be used on the SSB Function: Selects the gain curve of the AGC amplifier.
modes (LSB and USB). Available Values: nor / SLP
Available Values: Frnt / dAtA / PC Default Setting: nor
Default Setting: Frnt nor (NORMAL): The AGC output level will follow a
Frnt (FRONT): Selects the microphone connected to linear response to the antenna input
the front panel’s MIC jack while using level, while AGC is activated.
the SSB modes. SLP (SLOPED): The AGC output level will increase
dAtA: Selects the microphone connected to at 1/10 the rate of the antenna input
pin 1 of the PACKET Jack while us- level, while AGC is activated.
ing the SSB modes. SLOPE
PC: This parameter is for future expansion

Audio Output
of this transceiver’s capabilities, but at
NORMAL
this time is not supported.
085 J3E TX BPF
Function: Selects the audio passband of the DSP modula-
Input Signal
tor on the SSB mode.
Available Values: 1-30 / 1-29 / 2-28 / 3-27 / 4-26 / 3000
091 rout HEADPHN
1-30: 50-3000(Hz)
Function: Selects one of three audio mixing modes when
1-29: 100-2900(Hz)
2-28: 200-2800(Hz) using headphones during Dual Receive operation.
3-27: 300-2700(Hz) Available Values: SEP / Con1 / Con2
4-26: 400-2600(Hz) Default Setting: SEP
3000: 3000WB SEP (SEPARATE): Audio from the Main (VFO-A)
Default Setting: 3-27 (300-2700 Hz) receiver is heard only in the left
NOTE: ear, and Sub (VFO-B) receiver
The apparent power output, when using the widest band- audio solely in the right ear.
widths, may seem lower. This is normal, and it occurs be- Con1 (COMBINE 1): Audio from both Main (VFO-
cause the available transmitter power is distributed over a A) and Sub (VFO-B) receivers
wider bandwidth. The greatest compression of power out- can be heard in both ears, but
put, conversely, occurs when using the “4-26” setting (400- Sub (VFO-B) audio is attenu-
2600 Hz), and this setting is highly recommended for con- ated in the left ear and Main
test or DX pile-up work. (VFO-A) audio is attenuated in
the right ear.
086 J3E LSB CAR Con2 (COMBINE 2): Audio from both Main (VFO-
Function: Adjusts the receiver carrier point for the Main
A) and Sub (VFO-B) receivers
band’s (VFO-A) LSB mode.
is combined and heard equally
Available Values: –200 Hz ~ +200 Hz (10 Hz/steps)
in both ears.
Default Setting: 0 Hz
087 J3E USB CAR
Function: Adjusts the receiver carrier point for Main
band’s (VFO-A) USB mode.
Available Values: –200 Hz ~ +200 Hz (10 Hz/step)
Default Setting: 0 Hz
088 J3E SLSB CR
Function: Adjusts the receiver carrier point for the Sub
band’s (VFO-B) LSB mode.
Available Values: –200 Hz ~ +200 Hz (10 Hz/step)
Default Setting: 0 Hz
089 J3E SUSB CR
Function: Adjusts the receiver carrier point for Sub band’s
(VFO-B) USB mode.
Available Values: –200 Hz ~ +200 Hz (10 Hz/step)
Default Setting: 0 Hz

Page 120 FT-2000 OPERATING MANUAL


MENU MODE
RX DSP GROUP
092 rdSP CNTR LV 098 rdSP PKT SHP
Function: Adjusts the gain of the Contour filter. Function: Selects the passband characteristics of the DSP
Available Values: –40 ~ +20 dB filter for the PKT mode.
Default Setting: –15 dB Available Values: SOFt / ShAP
Default Setting: ShAP
093 rdSP CNTR WI
SOFt (SOFT): Primary importance is attached to the
Function: Adjusts the Q-factor of the Contour filter.
phase of the filter factor.
Available Values: 1 - 11
ShAP (SHARP): Primary importance is attached to the
Default Setting: 10
amplitude of the filter factor.
“Q”

“+” Gain
099 rdSP PKT SLP
“-- ” Gain
Function: Selects the shape factor of the DSP filter for
the PKT mode.
Available Values: StP(STEEP) / nEd(MEDIUM) /
GEnt(GENTLE)
Default Setting: nEd (MEDIUM)
100 rdSP PKT NAR
IF Function: Selects the passband of the DSP filter for the
BANDWIDTH
PKT “Narrow” mode.
CONTOUR “GAIN” AND “Q” Available Values: 25 / 50 / 100 / 200 / 300 / 400 Hz
Default Setting: 300 Hz
094 rdSP NOTCH W 101 rdSP RTY SHP
Function: Selects the bandwidth of the DSP NOTCH fil- Function: Selects the passband characteristics of the DSP
ter filter for the RTTY mode.
Available Values: nArr (Narrow) / uuid (Wide) Available Values: SOFt / ShAP
Default Setting: uuid (Wide) Default Setting: ShAP
095 rdSP CW SHAP SOFt (SOFT): Primary importance is attached to the
Function: Selects the passband characteristics of the DSP phase of the filter factor.
filter for the CW mode. ShAP (SHARP): Primary importance is attached to the
Available Values: SOFt / ShAP amplitude of the filter factor.
Default Setting: ShAP 102 rdSP RTY SLP
SOFt (SOFT): Primary importance is attached to the Function: Selects the shape factor of the DSP filter for
phase of the filter factor. the RTTY mode.
ShAP (SHARP): Primary importance is attached to the Available Values: StP(STEEP) / nEd(MEDIUM) /
amplitude of the filter factor. GEnt(GENTLE)
096 rdSP CW SLP Default Setting: nEd (MEDIUM)
Function: Selects the shape factor of the DSP filter for 103 rdSP RTY NAR
the CW mode. Function: Selects the passband of the DSP filter for the
Available Values: StP(STEEP) / nEd(MEDIUM) / RTTY “Narrow” mode.
GEnt(GENTLE) Available Values: 25 / 50 / 100 / 200 / 300 / 400 Hz
Default Setting: nEd (MEDIUM) Default Setting: 300 Hz
097 rdSP CW NARR
Function: Selects the passband of the DSP filter for the
CW “Narrow” mode.
Available Values: 25 / 50 / 100 / 200 / 300 / 400 / 500 /
800 / 1200 / 1400 / 1700 / 2000 Hz
Default Setting: 500 Hz

FT-2000 OPERATING MANUAL Page 121


MENU MODE
RX DSP GROUP SCOPE GROUP
ADVICE:
104 rdSP SSB SHP
This group’s adjustment has no effect, if the optional DMU-
Function: Selects the passband characteristics of the DSP
2000 Data Management Unit is not connected.
filter for the SSB modes (LSB and USB).
Available Values: SOFt / ShAP 107 SCP 1.8 FIX
Default Setting: ShAP Function: Selects the scan start frequency of the FIX mode
SOFt (SOFT): Primary importance is attached to the Spectrum Scope while monitoring on the 160 m amateur
phase of the filter factor. band.
ShAP (SHARP): Primary importance is attached to the Available Values: 1.800 - 1.999 MHz (1 kHz/step)
amplitude of the filter factor. Default Setting: 1.800 MHz
105 rdSP SSB SLP 108 SCP 3.5 FIX
Function: Selects the shape factor of the DSP filter for Function: Selects the scan start frequency of the FIX mode
the SSB modes (LSB and USB). Spectrum Scope while monitoring on the 80 m amateur
Available Values: StP(STEEP) / nEd(MEDIUM) / band.
GEnt(GENTLE) Available Values: 3.500 - 3.999 MHz (1 kHz/step)
Default Setting: nEd (MEDIUM) Default Setting: 3.500 MHz
106 rdSP SSB NAR 109 SCP 5.0 FIX
Function: Selects the passband of the DSP filter for the Function: Selects the scan start frequency of the FIX mode
“Narrow” SSB mode. Spectrum Scope while monitoring on the 60 m amateur
Available Values: 200 / 400 / 600 / 850 / 1100 / 1350 / band.
1500 / 1650 / 1800 / 1950 / 2100 / 2250 Hz Available Values: 5.250 - 5.499 MHz (1 kHz/step)
Default Setting: 1800 Hz Default Setting: 5.250 MHz
110 SCP 7.0 FIX
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 40 m amateur
band.
Available Values: 7.000 - 7.299 MHz (1 kHz/step)
Default Setting: 7.000 MHz

STEEP 111 SCP 10.1 FIX


MEDIUM Function: Selects the scan start frequency of the FIX mode
GENTLE Spectrum Scope while monitoring on the 30 m amateur
DSP FILTER PASSBAND band.
Available Values: (1)0.100 - (1)0.149 MHz (1 kHz steps)
Default Setting: (1)0.100 MHz
SHARP SOFT

DSP FILTER SHAPE

Page 122 FT-2000 OPERATING MANUAL


MENU MODE
SCOPE GROUP TUNING GROUP
112 SCP 14.0 FIX 118 tun DIALSTEP
Function: Selects the scan start frequency of the FIX mode Function: Setting of the Tuning Dial knob’s tuning speed
Spectrum Scope while monitoring on the 20 m amateur except the FM and FM-PKT modes.
band. Available Values: 1 / 5 / 10 Hz
Available Values: (1)4.000 - (1)4.349 MHz (1 kHz/step) Default Setting: 10 Hz
Default Setting: (1)4.000 MHz
119 tun CW FINE
113 SCP 18.0 FIX Function: Enabling/disabling of the “Fine” tuning speed
Function: Selects the scan start frequency of the FIX mode in the CW, RTTY, and PKT-SSB modes.
Spectrum Scope while monitoring on the 17 m amateur Available Values: EnA (ENABLE) / diS (DISABLE)
band. Default Setting: diS (DISABLE)
Available Values: (1)8.000 - (1)8.199 MHz (1 kHz/step) EnA (ENABLE): Tuning in 1 Hz steps on the CW,
Default Setting: (1)8.068 MHz RTTY, and PKT-SSB modes.
diS (DISABLE): Tuning according to the steps deter-
114 SCP 21.0 FIX
mined via menu item “118 tun
Function: Selects the scan start frequency of the FIX mode
DIALSTEP.”
Spectrum Scope while monitoring on the 15 m amateur
band. 120 tun MHz SEL
Available Values: (2)1.000 - (2)1.449 MHz (1 kHz/step) Function: Selects the tuning steps for the [SUB VFO-B]
Default Setting: (2)1.000 MHz knob when the [MHz] button is pressed.
Available Values: 1 / 0.1 MHz
115 SCP 24.8 FIX
Default Setting: 1 MHz
Function: Selects the scan start frequency of the FIX mode
Spectrum Scope while monitoring on the 12 m amateur 121 tun AM STEP
band. Function: Selects the tuning steps for the microphone’s
Available Values: (2)4.800 - (2)4.989 MHz (1 kHz/step) [UP]/[DWN] keys in the AM mode.
Default Setting: (2)4.890 MHz Available Values: 2.5 / 5 / 9 / 10 / 12.5 kHz
Default Setting: 5 kHz
116 SCP 28.0 FIX
Function: Selects the scan start frequency of the FIX mode 122 tun FM STEP
Spectrum Scope while monitoring on the 10 m amateur Function: Selects the tuning steps for the microphone’s
band. [UP]/[DWN] keys in the FM and FM-PKT modes.
Available Values: (2)8.000 - (2)9.699 MHz (1 kHz/step) Available Values: 5 / 6.25 / 10 / 12.5 / 20 / 25 kHz
Default Setting: (2)8.000 MHz Default Setting: 5 kHz
117 SCP 50.0 FIX 123 tun FM DIAL
Function: Selects the scan start frequency of the FIX mode Function: Setting of the Tuning Dial knob’s tuning speed
Spectrum Scope while monitoring on the 6 m amateur band. in the FM mode.
Available Values: (5)0.000 - (5)3.999 MHz (1 kHz/step) Available Values: 10 / 100 Hz
Default Setting: (5)0.000 MHz Default Setting: 100 Hz
124 tun MY BAND
Function: Programs a band to be skipped while selecting
bands using the [SUB VFO-B] knob.
Available Values: 1.8 ~ 50 / GE / AU
Default Setting: ---
To program the band to be skipped, rotate the [SUB VFO-
B] knob to recall the band to be skipped while selecting
bands via the [SUB VFO-B] knob, then press the [ENT]
button to change this setting to “ON” (a “d
d” notation will
replace the “E
E” notation). Repeat the same procedures to
cancel the setting (skipped “Off”: “d
d” notation appears).

FT-2000 OPERATING MANUAL Page 123


MENU MODE
TX AUDIO GROUP
125 tAUd EQ1 FRQ 131 tAUd EQ3 FRQ
Function: Selects the center frequency of the lower range Function: Selects the center frequency of the high range
for the parametric microphone equalizer. for the parametric microphone equalizer.
Available Values: OFF / 100 ~ 700 Hz (100 Hz/step) Available Values: OFF / 1500 ~ 3200 Hz (100 Hz/step)
Default Setting: OFF Default Setting: OFF
OFF: The equalizer gain and Q-factor are set to OFF: The equalizer gain and Q-factor are set
factory defaults (flat). to factory defaults (flat).
100 ~ 700: Center frequencies of 100 Hz ~ 700 Hz. 1500 ~ 3200: Center frequencies of 1500 Hz ~ 3200 Hz.
You may adjust the equalizer gain and Q- You may adjust the equalizer gain and
factor at this selected audio frequency via Q-factor in this selected audio fre-
menu items “126 tAUd EQ1 LVL” and quency via menu items “132 tAUd EQ3
“127 tAUd EQ1 BW.” LVL” and “133 tAUd EQ3 BW.”
126 tAUd EQ1 LVL 132 tAUd EQ3 LVL
Function: Adjusts the equalizer gain of the low range of Function: Adjusts the equalizer gain of the high range of
the parametric microphone equalizer. the parametric microphone equalizer.
Available Values: –20 ~ +10 Available Values: –20 ~ +10
Default Setting: +5 Default Setting: +5
127 tAUd EQ1 BW 133 tAUd EQ3 BW
Function: Adjusts the Q-factor of the low range of the Function: Adjusts the Q-factor of the high range of the
parametric microphone equalizer. parametric microphone equalizer.
Available Values: 1 ~ 10 Available Values: 1 ~ 10
Default Setting: 10 Default Setting: 10
128 tAUd EQ2 FRQ 134 tAUd PE1 FRQ
Function: Selects the center frequency of the middle range Function: Selects the center frequency of the lower range
for the parametric microphone equalizer. for the parametric microphone equalizer when the speech
Available Values: OFF / 700 ~ 1500 Hz (100 Hz/step) processor is activated.
Default Setting: OFF Available Values: OFF / 100 ~ 700 Hz (100 Hz/step)
OFF: The equalizer gain and Q-factor are set Default Setting: 200 Hz
to factory defaults (flat). OFF: The equalizer gain and Q-factor are set to
700 ~ 1500: Center frequencies of 700 Hz ~ 1500 Hz. factory defaults (flat).
You may adjust the equalizer gain and 100 ~ 700: Center frequencies of 100 Hz ~ 700 Hz.
Q-factor at this selected audio frequency You may adjust the equalizer gain and Q-
via menu items “129 tAUd EQ2 LVL” factor at this selected audio frequency via
and “130 tAUd EQ2 BW.” menu items “135 tAUd PE1 LVL” and
“136 tAUd PE1 BW.”
129 tAUd EQ2 LVL
Function: Adjusts the equalizer gain of the middle range 135 tAUd PE1 LVL
of the parametric microphone equalizer. Function: Adjusts the equalizer gain of the low range of
Available Values: –20 ~ +10 the parametric microphone equalizer when the speech pro-
Default Setting: +5 cessor is activated.
Available Values: –20 ~ +10
130 tAUd EQ2 BW
Default Setting: 0
Function: Adjusts the Q-factor of the middle range of the
parametric microphone equalizer. 136 tAUd PE1 BW
Available Values: 1 ~ 10 Function: Adjusts the Q-factor of the low range of the
Default Setting: 10 parametric microphone equalizer when the speech proces-
sor is activated.
Available Values: 1 ~ 10
Default Setting: 2

Page 124 FT-2000 OPERATING MANUAL


MENU MODE
TX AUDIO GROUP TX GNRL GROUP
137 tAUd PE2 FRQ 143 tGEn BIAS
Function: Selects the center frequency of the middle range This Menu item does not work. Please do not change
for the parametric microphone equalizer when the speech this setting.
processor is activated.
144 tGEn MAX PWR
Available Values: OFF / 700 ~ 1500 Hz (100 Hz/step)
Function: Selects a maximum output power limit.
Default Setting: 800 Hz
Available Values: 10 / 20 / 50 / 100 W
OFF: The equalizer gain and Q-factor are set
Default Setting: 100 W
to factory defaults (flat).
700 ~ 1500: Center frequencies of 700 Hz ~ 1500 Hz. 145 tGEn PWRCTRL
You may adjust the equalizer gain and Function: Configures the [RF PWR] knob.
Q-factor at this selected audio frequency Available Values: ALL / CAr
via menu items “138 tAUd PE2 LVL” Default Setting: ALL
and “139 tAUd PE2 BW.” ALL:The [RF PWR] knob is enabled on all modes.
CAr: The [RF PWR] knob is enabled in all modes
138 tAUd PE2 LVL
except SSB. In this configuration, the SSB out-
Function: Adjusts the equalizer gain of the middle range
put power will be set to maximum, regardless
of the parametric microphone equalizer when the speech
of the [RF PWR] knob’s position.
processor is activated.
Available Values: –20 ~ +10 146 tGEn ETX-GND
Default Setting: 0 Function: Enables/Disables the TX GND jack on the rear
panel.
139 tAUd PE2 BW
Available Values: EnA(ENABLE) / diS(DISABLE)
Function: Adjusts the Q-factor of the middle range of the
Default Setting: diS(DISABLE)
parametric microphone equalizer when the speech proces-
sor is activated. 147 tGEn TUN PWR
Available Values: 1 ~ 10 Function: Selects a maximum output power limit for driv-
Default Setting: 1 ing the input circuit of an external linear RF amplifier
while tuning (while using the Remote Control function
140 tAUd PE3 FRQ
of the linear RF amplifier).
Function: Selects the center frequency of the high range
Available Values: 10 / 20 / 50 / 100 W
for the parametric microphone equalizer when the speech
Default Setting: 100 W
processor is activated.
Available Values: OFF / 1500 ~ 3200 Hz (100 Hz/step) 148 tGEn VOX SEL
Default Setting: 2100 Hz Function: Selects the audio input source for triggering
OFF: The equalizer gain and Q-factor are set TX during VOX operation.
to factory defaults (flat). Available Values: nic / dAtA
1500 ~ 3200: Center frequencies of 1500 Hz ~ 3200 Hz. Default Setting: nic
You may adjust the equalizer gain and nic(MIC): The VOX function will be activated by
Q-factor in this selected audio fre- microphone audio input.
quency via menu items “141 tAUd PE3 dAtA(DATA): The VOX function will be activated
LVL” and “142 tAUd PE3 BW.” by data audio input.
141 tAUd PE3 LVL 149 tGEn EMRGNCY
Function: Adjusts the equalizer gain of the high range of Function: Enables Tx/Rx operation on the Alaska Emer-
the parametric microphone equalizer when the speech pro- gency Channel, 5167.5 kHz.
cessor is activated. Available Values: EnA(ENABLE) / diS(DISABLE)
Available Values: –20 ~ +10 Default Setting: diS(DISABLE)
Default Setting: 0 When this Menu Item is set to “EnA(ENABLE),” the spot
frequency of 5167.5 kHz will be enabled. The Alaska
142 tAUd PE3 BW
Emergency Channel will be found between the Memory
Function: Adjusts the Q-factor of the high range of the
channels “P-1” and “01 (or 1-01).”
parametric microphone equalizer when the speech proces-
IMPORTANT:
sor is activated.
The use of this frequency is restricted to stations operat-
Available Values: 1 ~ 10
ing in or near Alaska, and only for emergency purposes
Default Setting: 1
(never for routine operations). See §97.401(c) of the
FCC’s regulations for details.

FT-2000 OPERATING MANUAL Page 125