Kozlosan Model Simpel 25 Og 40 - Manual
Kozlosan Model Simpel 25 Og 40 - Manual
Kozlosan Model Simpel 25 Og 40 - Manual
MODEL: SLIMPEL
Green Energy Engineering Ltd, 198 Lurgan Road, Dromore, Craigavon, Co.Down, Northern Ireland. BT25 1HL
Tel: +44 (0) 28 38 820 043 Fax: +44 (0) 28 38 820 987 Email: info@geeltd.org
Downloaded from www.Manualslib.com manuals search engine
TABLE OF CONTENTS
Section Page
Introduction 3
Safety instructions 4
How to biomass system works 6
Specifications 8
Installation 12
Operating the Heating system 15
Maintenance Overview 16
Troubleshooting 19
Installation Scheme 21
With proper installation and maintenance, your heating system will provide years of non-polluting, low cost
heat for your home.
To insure correct installation and safe operation of your KOZLUSAN biomass heating system, you should:
Hire a licensed heating contractor to install the biomass heating system and integrate it with your
heating system. This contractor should have experience with installation and operation of gas, oil,
and solid fuel heating appliances and be familiar with local building codes, fire codes and other
regulations.
Read this manual and learn how to safely operate and maintain your KOZLUSAN biomass heating
system.
The assembling and start up (setting) of KOZLUSAN biomass boiler has to be carried out by
our own customer service or by authorized qualified technicians.
Ö-Norm M 7135
DIN-PLUS Norm
SWISSPELLET
Diameter: 6 mm Length: 5-30 mm (20% - 45 mm)
Only this way low-emission, economical and reliable operation can be guaranteed. Any disregard of
these requisites leads to immediate expiry of warranty.
The pellets must be stored in dry conditions to enable them to be transported without problems and
to achieve trouble-free operation with optimum combustion combined with the greatest possible
efficiency.
We do not assume any liability for unauthorized technical modifications, and resulting damages are
not covered by warranty.
Operational procedures or alterations of any sort, carried out by unauthorized persons, as well as
disregarding the general guidelines and the indicated safety instructions as specified here, result in
immediate termination of all warranty claims.
Please read the safety instructions below before operating the system. Disregarding the safety
instructions may lead to injuries, perilous situations or damage the pellet boiler.
Page 3
The pellet heater system may only be operated be in faultless technical condition. Malfunctions
and damage which affect or could affect safety must be corrected immediately by our trained
personnel.
The assembly may only be conducted by our customer service, or by a certified specialist. The
system is equipped with rotating parts, which move with a relatively large turning movement
(crushing hazard).
Under the casing and in the terminal box there are voltaged components. Do not remove the
casing or terminal box.
Never open the inspection openings of the boiler while in continuous operation, hot exhaust gas
and dust may escape.
The system should be turned off before the implementation of maintenance work. Wait until the
pellet boiler has cooled down (check the temperature on the display).
The boiler needs to be switched off before carrying out the cleaning of the chimney. Wait until
the pellets have burned down completely (approx. 20 minutes – danger of explosion through
back up of exhaust gas.
Never perform independent repair work on our system, call trained personnel!
Put a signboard into the heating room that forbids to smoke or to use open light or fire.
Once a month, test the boiler doors and the water connections for leaks and damage.
Safety and monitoring devices may not be removed, bypassed or taken out of service in any
other way.
Page 4
When setting the domestic water temperature above 60 °C, you have to ensure that the hot water
is mixed with cold water to avoid scald.
The pellet heater system may only be set up and operated in heating and plant rooms which
comply with legal requirements.
Regular control of pellet feeding devices, automatic ignition devices and feeding features.
Please note that even when the system is turned off, different functions are in operation.
(For example the anti-freeze protective device; pumps and mixers are moved periodically during
the night avoid an accumulation of the storings). To ensure that no electricity runs through
the system, take off the system from electricity.
Make sure that the return temperature does not drop below 50 °C. Disregarding leads to expiry
of warranty!
Page 5
The KOZLUSAN biomass heating system produces few emissions and achieves a high level of heating
efficiency because of its unique design. The fully automated fuel delivery is ‘poured from top’ into an air
fed burn pot where the fuel is self ignited before the full modulation control system controls the burn for
minimum emissions with maximum heat output.
To understand how the KOZLUSAN heating system works, we need to look at the flow of air, fuel and gases
through the heating system and the transfer of heat from the superheated gases to the thermal transfer fluid.
We also need to understand some of the terminology used to describe the systems operation;
1. Fuel is fed from the fuel store via an auger. The fuel is poured from the top into the cylindrical burn
pot to maintain a physical separation between the fuel store and the fuel feed. Heat from the burning
fire is force fed air from a variable speed fan. Various sensors measure temperature in the boiler (a
thermostat that works in water) a flue gas temperature sensor (probe in the chimney), outside
temperature sensor (the weather or room temperature) and a safety cut off temperature sensor to
protect against overheating (high limit stat).
2. As air flows through the firebox, its temperature rises to nearly 1000º C.
3. This superheated air rises upwards and then through a series of heat tubes where the heat is
transferred into the thermal fluid.
4. By the time the exhaust air reaches the flue, most of its thermal energy has been absorbed. The final
temperature of the escaping flue gas is less than 175º C.
Page 6
1. KOZLUSAN heating systems recommends a mixture of water and propylene glycol as a heat
transfer fluid. Glycol is a non-toxic solution that works like the antifreeze in your car to prevent
corrosion and freezing.
2. A pump pushes fluid around the heat transfer jacket which absorbs heat from the combustion gases.
The fluid exits the internal manifold at about 80-85º C.
3. The fluid flows past an aquastat (water thermostat) that regulates the burn rate of the heating system
in conjunction with the flue gas temperature sensor that measure the temperature in the flue. This
information is used to determine the amount of air and fuel being used to ensure efficient heat
transfer and to ensure the fan does not simply blow the heat up the flue. The heated fluid is used to
transfers the heated fluid to your home system where it provides warmth to your home, garage,
basement and other structures; preheats your domestic hot water; heats your pool; and/or melts snow
on your driveway.
4. Having transferred the heat to the home system, the fluid exits the external heat exchanger and
repeats its path through the internal manifold.
Page 7
SLIMPEL 25
Page 8
Page 9
Page 10
load(pascal)
Dimensions
Page 11
Your KOZLUSAN heating system should be installed by a qualified heating contractor who is thoroughly
familiar with gas, oil, and solid fuel heating appliances. Also, you should be sure to comply with local
building codes, fire codes and other regulations when installing the heating system.
Safe Practices
Hire a licensed contractor with experience in design and installation automated heating systems.
Comply with local building codes, fire codes and other regulations when installing this heating system.
Make sure to identify sources of make-up air in the room where the heating system is located. The
KOZLUSAN Heating System, exhaust fans and other appliances all draw air from the room. Be certain
there is an adequate source of fresh air to offset these demands or you may create negative pressure in
the room and starve the heating system of combustion and create draft problems in your flue.
Connect the heating system to a properly installed and operating chimney and vent it to the outside.
Be sure your chimney is safely constructed and in good repair. Before installation, have the chimney
inspected by a qualified inspector.
Be sure to provide thermal spike protection for the heating system (see Wiring and Controls pg. 30).
DO NOT install the heating system in a mobile home or trailer. Instead, install the heating system
outside in a covered enclosure and pipe the hot water into the mobile home.
Page 12
A chimney performs two functions: it removes smoke and flue gases from the heating system, and it provides
“draft” for the fire. Draft is the term used to describe the suction that occurs when hot air rises and creates a
vacuum in the firebox. That vacuum draws fresh air into the firebox and feeds combustion of the wood. No
heating system can operate properly without adequate draft.
Proper installation of the chimney flue is critical to the performance of your KOZLUSAN Heating System.
The majority of problems encountered after installation are attributable to a flue that is improperly sized or
otherwise provides inadequate draft to the heating system.
You may connect the KOZLUSAN Heating System to an existing flue or chimney subject to the following
conditions.
1. A qualified professional has inspected, repaired (if necessary), thoroughly cleaned the chimney and
determined it is suitable for use with a residential heating appliance that burns solid fuel.
2. The chimney or flue should be at least 3-4 m tall and sized correctly for the KOZLUSAN Heating
System model installed.
3. Do not share a flue with another heating system, appliance or fireplace. Do not use a flue that already
provides make-up air to the cellar or basement.
4. Tightly close the cleanout opening in the base of the chimney.
Mount the expansion tank (Optional “Open System” Installation Kit Only)
The heating system is leak-tested at the factory during final assembly, and the heat transfer fluid drained for
shipment. The recommended solution is a mix of 30% propylene glycol to 70% water unless you are located
in a very cold climate, or you plan to leave the heating system unused for a long period of time. A 30%
solution of propylene glycol is adequate to lower the freezing point to -13º C and raise the boiling point to
102º C.
Page 13
Page 14
Safe Practices
5. Use the tools provided if it is necessary to rake ashes or unburnt fuel from the burnpot
6. DO NOT jockey burning fuel in the burnpot.
7. DO NOT throw fuel into the burnpot via the access door
8. Keep the access door closed tight except when tending the burnpot.
9. Keep the heating system area clear of combustible materials, gasoline, and other flammable vapors or liquids.
10. DO NOT forget to regularly empty the ash collection box.
11. DO NOT store fuel or combustables within the appliance installation clearances or within the space required for fueling,
ash removal, and other routine maintenance operations.
12. DO NOT allow anyone who is under the influence of drugs or alcohol or is unfamiliar with the correct operation of the
heating system to add fuel or otherwise use this heating system.
13. DO NOT let children play around the heating system when it is operating. To avoid burns or other injury, alert all
persons to the hazards of hot heating system surfaces.
14. For adjustments of digital control panel, please read the “TCNet Boiler Controller Manual” that is given by the
boiler.
Page 15
1. Check your fuel supply regularly and allow suitable time for deliveies – try not to run out of fuel
2. Check the ash box and empty regularly.
3. Inspect chimney, flue pipes, flue pipe joints, and flue pipe seals regularly to ensure that smoke and flue gases are not
drawn into, and circulated by, your home’s air circulation system. If you observe rust or smoke escaping, replace the pipe
immediately.
4. Exercise the safety relief valve at least once a year.
5. Check the water pressure is between 1 and 2 bar – if too low top up system with more water.
6. DO NOT clean heating system surfaces when the unit is hot. Wait until the unit cools and then clean with soap and
water.
ATTENTION
This work may only be performed by certified specialists or by KOZLUSAN customer service
Every guarantee / warranty expires with independent maintenance work!
Periodical Maintenance
Brushing Burnpot
ATTENTION
We recommend letting the boiler cool down for at least 2-3 hours later switching off the system before proceeding with
these works.
Page 16
Cleaning of the suction fan and the flue tube (See pictures below)
Inspection of the grate cleaning lever
Inspection and cleaning of the air-flow sensor in aggregate test
Inspection of gaskets on the combustion chamber door and ash box
Operational test of the heat exchanger cleaning
Cleaning of the exhaust sensor
Test the igniter tube for residue
Test upper and lower parts of the burner for damage and leaks
Test the intervals of the sensors (grate motor, separator)
Lubrication of the heat exchanger cleaning drive and grate bar
Exhaust gas measurement
Page 17
Maintenance volume from the yearly maintenance and the following additional work
Visual check and cleaning of the hoist basket lever for the heat exchanger cleaning:
In addition, remove the boiler cover, vacuum out the existing ashes and check the function of the hoist basket lever.
According to function control, using caulking strip newly caulk the boiler cover and reassemble.
Cleaning of secondary air channels in burnpot and the base of burnpot.
Detach the hopper tank from the boiler firstly. Then remove the burnpot carefully. (See pictures below)
Test run of all electrical equipment
If necessary, exchange the ignition blower (after approx. 500 hours of operation)
If necessary, exchange the coal for the suction turbines. (after approx. 500 hours of operation)
Page 18
Dark screen Safety Temperature Limiter has relased Let the boiler cool down to 80 °C
Reset the Safety Temperature Limiter and search for
cause (e.g. Defect pump..)
No more pellets in fuel hooper Refill
Error: Out of Pellets
Defective pellet level sensor > Inform customer service
The ambient temperature should be 0-45 °C for
Too cold ambient temperature
proper working
Low quality pellets Change pellets
Error: Ignition failed
Ignition device malfunction > Inform customer service
Page 19