7018FX2 Data Sheet - 0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

7018FX2 Industrial Ethernet Switch

N-Tron® Networking Series

Managed Industrial Ethernet Switch


The N-TRON 7018FX2 gigabit capable Industrial Ethernet Switch
offers outstanding performance and ease of use. It is ideally suited
for connecting Ethernet enabled industrial and/or security equipment
and is a fully managed switch.
PRODUCT FEATURES
• Fourteen 10/100BaseTX RJ-45 Ports
• Two 100BaseFX Ports, ST or SC Style
• Two Optional SFP (Mini-GBIC) Gigabit Transceivers
• 1000BaseSX/LX Fiber with LC style connectors or
• 1000BaseT Copper with RJ-45 connectors
• -40oC to 70oC Operating temperature
• ESD and Surge Protection Diodes on all Ports Shown with Optional Gigabit
• Auto Sensing 10/100BaseTX, Duplex, and MDIX SFP Transceivers installed
• Redundant Power Inputs (10-30VDC)
• Configurable Alarm Contact & Bi-Color Fault Status LED
Rapid Spanning Tree Protocol
Fully Managed Features: RSTP allows the switch to be configured in a ring or mesh topology,
• SNMP v1, v2, v3 and Web Browser Management and provides support for redundant path communications with high
• Detailed Ring Map and Fault Location Charting speed (rapid) healing.
• N-Ring™ Technology with ~30ms Healing
• N-View™ OPC Monitoring Remote Monitoring Options
• N-Link Redundant N-Ring Coupling For ease of configuration and monitoring, the 7018FX2 offers web
browser management and N-View OLE for process control (OPC) server
• Plug-and-play IGMP Support
software. The N-TRON N-View software can be combined with popular
• 802.1Q tag VLAN and Port VLAN HMI software packages to add network traffic monitoring, trending,
• 802.1p QoS and Port QoS and alarming to any application using N-TRON switches In addition,
• EtherNet/IP™ CIP Messaging SNMP is available for switch link and status monitoring. The alarm
• LLDP (Link Layer Discovery Protocol) contact and status LED can be configured to respond to power failure
• Port Trunking on power input 1 or input 2, N-Ring broken, partial break high, partial
• Port Mirroring break low, or if multiple ring managers are detected.
• 802.1d, 802.1w, 802.1D RSTP
N-Ring Technology
• DHCP Server, Option 82 relay, Option 61, IP Fallback
• Port Security—MAC Address Based N-TRON's 7018FX2 ring manager using N-TRON's N-Ring technology
offers expanded ring size capacity, detailed fault diagnostics, and
Management Features a standard healing time of ~30ms. The 7018FX2 ring manager
The 7018FX2 offers several management functions that can be easily periodically checks the health of the ring via packets. If the ring manager
configured using a web browser. stops receiving these health check packets, it converts the ring to a linear
topology within ~30ms. When all switches in the ring are N-TRON
IGMP Snooping - Internet Group Management Protocol allows the fully managed switches, a detailed ring map and fault location chart
7018FX2 switch to forward and filter multicast traffic intelligently. will also be provided on the ring manager’s web browser and OPC
VLAN - Virtual Local Area Network allows you to segment the switch server to identfy the health status of the ring. N-Link allows the
in order to create two or more separate local area network domains. linking of two N-Rings. Up to 250 fully managed N-TRON switches
QoS - Quality of Service provides prioritization of network traffic in can participate in N-Ring topologies.
order to provide better network service. QoS improves the latency of Industrial Packaging and Specifications
prioritized Ethernet packets required for ring management, real-time, The 7018FX2 is designed to operate in industrial environments. It is
and other interactive applications. housed in a rugged steel DIN-Rail enclosure. It has extended industrial
Port Trunking - Trunking (link aggregation) enables multiple physical specifications and features to meet or exceed the operating parameters
ports to be linked together and function as one uplink to another of connected equipment. These include extended temperature ratings,
N-TRON trunking capable switch configured in the same manner, extended shock and vibration specs, redundant power inputs, and high
thereby increasing the bandwidth between switches. This configuration MTBF (greater than 2M hours).
can provide increased bandwidth and redundancy to applications
requiring high levels of fault tolerant operation. Ease of Use
The 10/100BaseTX ports are auto sensing and auto configuring.
Port Mirroring - Allows the traffic on one port to be duplicated and sent Each copper port is automatically negotiated for maximum speed
to a designated mirror port. Port mirroring is used to monitor Ethernet and performance by default, but can also be hard coded through the
traffic on the designated source port using the assigned mirror port. user interface. The two optional gigabit ports support full 2000 Mb/s
DHCP-DHCP Server / Client automates the assignment of IP addresses. communications via 1000BaseSX/LX/T. For added flexibility, these
DHCP Option 82 assures that if a device on a specific port is replaced, SFP (Mini-GBIC) gigabit transceivers are field upgradable or can be
the replacement receives the same IP address as the original device. factory installed at the time of purchase.
7018FX2 Specifications

7018FX2 Specifications
Switch Properties Fiber Transceiver Characteristics
Number of MAC Addresses: 8000 Fiber Length* 2km 15km 40km 80km
Aging Time: Programmable TX Power Min -19dBm -15dBm -5dBm -5dBm
Latency Typical: 2.6 μs RX Sensitivity Max -31dBm -31dBm -34dBm -34dBm
Wavelength 1310nm 1310nm 1310nm 1550nm
Switching Method : Store-and-Forward
* Fiber Length distances represent typical performance. Link budgets should be evaluated
based on specific application conditions.
Case Dimensions
Height: 2.3" (5.8 cm)
Width: 8.3" (21.0 cm) SFP Gigabit Fiber Transceiver Characteristics
Depth: 4.8" (12.1 cm) Fiber Length*
550m for 50/125µm 10km 40km 80km
275m for 62.5/125µm
Weight (max): 3.3 lbs (1.5 kg) TX Power Min -9.5dBm -9.5dBm -2dBm 0dBm
DIN-Rail Mount: 35mm RX Sensitivity Max -17dBm -20dBm -22dBm -24dBm
Wavelength 850nm 1310nm 1310nm 1550nm
Electrical Assumed Fiber Loss 3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km
Redundant Input Voltage: 10-30 VDC (Regulated) Laser Type VCSEL FP DFB DFB
Input Current (max): 520mA max. @24V * Fiber Length distances represent typical performance. Link budgets should be evaluated
based on specific application conditions.
BTU/hr: 42.6@24VDC
N-TRON Power Supply: NTPS-24-1.3 (1.3 A@24V)
Connectors
Environmental 10/100BaseTX: Fourteen (14) RJ-45 Copper Ports
Operating Temperature: -40 C to 70 C
o o 100BaseFX: Two (2) SC or ST Fiber Duplex Ports
Storage Temperature: -40oC to 85oC 1000BaseT: Up to Two (2) RJ-45 Gigabit
Copper Ports (optional)
Operating Humidity: 5% to 95%
(Non Condensing) 1000BaseSX: Up to Two (2) LC Duplex Gigabit
Fiber Ports (optional)
Operating Altitude: 0 to 10,000 ft.
Recommended Wiring Clearance
Shock and Vibration (bulkhead mounted) Front: 4" (10.16 cm)
Shock: 200g @ 10ms Side: 1" (2.54 cm)

Vibration/Seismic: 50g, 5-200Hz, Triaxial


Regulatory Approvals
FCC Title 47, Part 15, Subpart B - Class A; ICES-003 - Class A
Reliability UL Listed (US and Canada) 1604; ANSI/ISA-12.12.01-2007
Class I, Div 2, Groups A, B, C, D, and T4A
MTBF: >2 Million Hours
CE: EN61000-6-2:2001: EN61000-4-2, 3, 4, 5, 6
Network Media EN55022:1998+A1:1999+A2:2002-Class A
10BaseT: >Cat3 Cable EN50155 for Railway Applications
100BaseTX: >Cat5 Cable GOST-R Certified, RoHS Compliant
1000BaseT: >Cat5e Cable
100BaseFX, 1000BaseSX Multimode: 50-62.5/125µm
Designed to comply with:
IEEE 1613 for Electric Utility Substations
100BaseFXE, 1000BaseLX Singlemode: 7-10/125µm NEMA TS1/ TS2 for Traffic control
7018FX2 Specifications

7018FX2 Industrial Ethernet Switch Ordering Information

7018FX2-XX Fourteen 10/100BaseTX Ports, Two Multimode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports
7018FXE2-XX-YY Fourteen 10/100BaseTX Ports, Two Singlemode 100BaseFX Fiber Optic Ports, Two Optional Gigabit SFP Ports
NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port
NTSFP-SX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseSX Multimode GB Fiber Optic Port
NTSFP-LX-ZZ Optional SFP (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port
NTPS-24-1.3 N-TRON Power Supply - (1.3 Amp @ 24VDC)
700-PM Panel Mount kit
URMK Universal Rack Mount Kit
Where: XX = ST or SC
YY = 15, 40, or 80 for Singlemode, Blank for Multimode
E = Singlemode, and Blank Otherwise
ZZ = 10, 40, or 80 for GB Singlemode
If SFP Transceiver is not specified at the time of purchase, slots will remain blank with covers

For over 50 years, Red Lion has strived to be THE Industrial Data Company™. The company empowers industrial
organizations around the world to unlock the value of data by developing and manufacturing innovative
solutions to access, connect and visualize their information. Red Lion products make it easy for companies to
gain real-time data visibility that drives productivity. Red Lion is part of Spectris plc, the experts in providing
insight through precision measurement. For more information, please visit www.redlion.net.

www.redlion.net ©2013-2023 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron, N-View, N-Ring and THE Industrial Data Company
contact us are trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners.

LD1082 02 2023

You might also like