Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PNOZ X2 7P en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Unit features Safety features

` Positive-guided relay outputs: The relay meets the following safety


Gertemerkmale ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil

– 3 safety contacts (N/O), instanta- requirements:


neous ` The circuit is redundant with built-in
– 1 auxiliary contact (N/C), instan- self-monitoring.
taneous ` The safety function remains effec-
` Connection options for: tive in the case of a component fail-
– E-STOP pushbutton ure.
– Safety gate limit switch ` The correct opening and closing of
– Reset button the safety function relays is tested
– Light barriers automatically in each on-off cycle.
` LED indicator for:
Gertebild

– Switch status channel 1/2


Safety relay for monitoring E-STOP – Supply voltage
][Bildunterschrift_NOT_Sch.tuer_Licht

pushbuttons, safety gates and light ` Plug-in connection terminals (either


beam devices spring-loaded terminal or screw
terminal)
Approvals ` See order reference for unit types

Unit description
PNOZ X2.7P
The safety relay meets the require-
Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ

ments of EN 60947-5-1, EN 60204-1


‹ and VDE 0113-1 and may be used in
applications with
` E-STOP pushbuttons
‹ ` Safety gates
` Light beam devices
Zulassungen

Block diagram
il
tb
a
h
s
k
c
lo
B
d

A1 A2 S11 S12 S21 S22 S52 S12 S34 13 23 33 41

~ Reset/
)*

Input Input Input Start


= K1
(

Power
K2

14 24 34 42

*only with UB 24 – 240 VAC/DC

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Function description – short circuits in the input circuit – shorts between contacts in the
and, with a monitored reset, in input circuit.
` Single-channel operation: no re- the reset circuit too. ` Monitored reset: Unit is active once
][Funktionen_einkanalig_Erd_Start ][Funktionen_berStart_Wartezeit

dundancy in the input circuit, earth ` Dual-channel operation with detec- the input circuit is closed and once
][Funktionen_zweikanalig_mit_quer_ber

faults in the reset circuit are detect- tion of shorts across contacts: re- the reset circuit is closed after the
ed. dundant input circuit, detects waiting period has elapsed
` Dual-channel operation without de- – earth faults in the reset and input (see technical details).
][Funktionen_zweikanalig_ohne_quer

tection of shorts across contacts: circuit, ` Increase in the number of available


][Funktionen_Kontaktvervielfachung

redundant input circuit, detects – short circuits in the input circuit instantaneous safety contacts by
– earth faults in the reset and input and, with a monitored reset, in connecting contact expansion
circuit, the reset circuit too, modules or external contactors.

Timing diagram
x
2
b
u
_
rm
g
a
itd
e
][Z

POWER

Reset/Start

Input

Output safe

Output aux.
t3 t1 t2 t3 t1 t2

Key
` Power: Supply voltage ` Output safe: Safety contacts 13-14, ` t1: Switch-on delay
` Reset/start: Reset circuit S12-S34 23-24, 33-34 ` t2: Delay-on de-energisation
` Input: Input circuits S11-S12, S21- ` Output aux: Auxiliary contacts 41- ` t3: Waiting period
S22, S52 42

Wiring

Please note:
][Verdrahtung_Si_unverz_1Hi_unverz

` Information given in the “Technical


details” must be followed.
` Outputs 13-14, 23-24, 33-34 are
safety contacts, output 41-42 is an
auxiliary contact (e.g. for display).
` To prevent contact welding, a fuse
should be connected before the
output contacts (see technical de-
tails).
` Calculation of the max. cable runs
lmax in the input circuit:
Rlmax
Imax =
Rl / km

Rlmax = max. overall cable resist-


ance (see technical details)
Rl /km = cable resistance/km
` Use copper wire that can withstand
60/75 °C.
` Sufficient fuse protection must be
provided on all output contacts with
capacitive and inductive loads.

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-2
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Preparing for operation


Betriebsbereitschaft herstellen

` Supply voltage

Supply voltage 24 – 240 VAC/DC 24 VAC/DC

A1 L1 A1 L+

S21

A2 N A2 L-

` Input circuit

Input circuit Single-channel Dual-channel


E-STOP S1 S1
without detection of shorts across con- S11 S11
tacts S21 S12 S21
S22 S52 S22 S12
S52

E-STOP S1
with detection of shorts across contacts S11
S11 S21
S52 S22
S12

Safety gate
without detection of shorts across con-
tacts
S1
S11 S11
S1
S21 S12 S21 S2
S22 S52 S22 S12
S52

Safety gate
with detection of shorts across contacts

S11
S1
S11 S12 S2
S52 S21
S22

Light beam device 24 V DC


S22
with detection of shorts across contacts
via ESPE S21
(not on units with a universal power supply) A2 S12
S52
GND

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

` Reset circuit

Reset circuit E-STOP wiring (single-channel) E-STOP wiring (dual-channel)


Safety gate (single-channel) Safety gate (dual-channel)
Monitored reset S3 S3
S12 S12

S34 S34

` Feedback circuit

Feedback circuit Automatic reset Monitored reset


Contacts from external contactors S3
S12
K5 K6
S34
13 (23, 33) L1
K5
14 (24 ,34) N
K6

` Key

S1/S2 E-STOP/safety gate switch


S3 Reset button

Switch operated

Gate open

Gate closed

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-4
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Terminal configuration
u
g
b
n
m
le
K

A1 13 23 33
P1
S52 S34 41 42
P2

PNOZ X2.7P

POWER
CH.1
CH.2
13 23 33 41

14 24 34 42

18992
P2
S11 S12 S21 S22
P1
A2 14 24 34

Installation Dimensions

` The safety relay should be installed * with spring-loaded terminals


Montage_PNOZ_X Abmessungen

in a control cabinet with a protec-


tion type of at least IP54.
` Use the notch on the rear of the unit
to attach it to a DIN rail.
` Ensure the unit is mounted securely
121 (4.76")

on a vertical DIN rail (35 mm) by us-


ing a fixing element (e.g. retaining
bracket or an end angle).

22,5
94 (3.70") (0.88")
* 101 (3.98")

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Notice Service life graph

This data sheet is only intended for use UB 24 VAC/DC


][WICHTIG_PDB_alt Lebensdauerkurve

during configuration. For installation

Corrente di esercizio nominale (A)


and operation, please refer to the op-

Corriente nominal de servicio (A)


10
erating instructions supplied with the

Nominale bedrijfsstroom (A)


unit.

Nominal operating current (A)


Nennbetriebstrom (A)

DC1: 24 V
Courant coupé (A)
1 DC13: 24 V

AC1: 230 V
AC15: 230 V
GB

0.1
NL
D

E
F

100 1000 10000 100000


I

D Schaltspielzahl x 103 E Número de ciclos x 103


GB Cycles x 103 I Numero dei cicli di commutazione x 103
F Nombre de manœuvres x 103 NL Aantal schakelingen x 103

UB 24 - 240 VAC/DC
Corrente di esercizio nominale (A)
Corriente nominal de servicio (A)

10
AC15: 230 V
Nominale bedrijfsstroom (A)
Nominal operating current (A)

DC1: 24 V
Nennbetriebstrom (A)

Courant coupé (A)

1
DC13: 24 V
AC1: 230 V

0.1
GB

NL
D

E
F

10 100 1000 10000


I

D Schaltspielzahl x 103 E Número de ciclos x 103


GB Cycles x 103 I Numero dei cicli di commutazione x 103
F Nombre de manœuvres x 103 NL Aantal schakelingen x 103
][Technische Daten PNOZ

Technical details

Electrical data
Supply voltage
Supply voltage UB AC/DC 24 - 240 V, 24 V
Voltage tolerance -15 %/+10 %
Power consumption at UB AC 4.5 VA Order no.: 777306, 787306
5.5 VA Order no.: 777305, 787305
Power consumption at UB DC 2.0 W Order no.: 777306, 787306
2.5 W Order no.: 777305, 787305
Frequency range AC 50 - 60 Hz
Residual ripple DC 160 %
Voltage and current at
Input circuit DC: 24.0 V 25.0 mA Order no.: 777306, 787306
30.0 mA Order no.: 777305, 787305
Reset circuit DC: 24.0 V 40.0 mA Order no.: 777305, 787305
50.0 mA Order no.: 777306, 787306
Feedback loop DC: 24.0 V 40.0 mA Order no.: 777305, 787305
50.0 mA Order no.: 777306, 787306

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-6
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Electrical data
Number of output contacts
Safety contacts (S) instantaneous: 3
Auxiliary contacts (N/C): 1
Utilisation category in accordance with EN 60947-4-1
Safety contacts: AC1 at 240 V Imin: 0.01 A , Imax: 6.0 A Order no.: 777306, 787306
8.0 A Order no.: 777305, 787305
Pmax: 1500 VA Order no.: 777306, 787306
2000 VA Order no.: 777305, 787305
Safety contacts: DC1 at 24 V Imin: 0.01 A , Imax: 6.0 A Order no.: 777306, 787306
8.0 A Order no.: 777305, 787305
Pmax: 150 W Order no.: 777306, 787306
200 W Order no.: 777305, 787305
Auxiliary contacts: AC1 at 240 V Imin: 0.01 A , Imax: 6.0 A Order no.: 777306, 787306
8.0 A Order no.: 777305, 787305
Pmax: 1500 VA Order no.: 777306, 787306
2000 VA Order no.: 777305, 787305
Auxiliary contacts: DC1 at 24 V Imin: 0.01 A , Imax: 6.0 A Order no.: 777306, 787306
8.0 A Order no.: 777305, 787305
Pmax: 150 W Order no.: 777306, 787306
200 W Order no.: 777305, 787305
Utilisation category in accordance with EN 60947-5-1
Safety contacts: AC15 at 230 V Imax: 3.0 A Order no.: 777306, 787306
6.0 A Order no.: 777305, 787305
Safety contacts: DC13 at 24 V (6 cycles/min) Imax: 4.0 A Order no.: 777306, 787306
5.0 A Order no.: 777305, 787305
Auxiliary contacts: AC15 at 230 V Imax: 3.0 A Order no.: 777306, 787306
6.0 A Order no.: 777305, 787305
Auxiliary contacts: DC13 at 24 V (6 cycles/min) Imax: 4.0 A Order no.: 777306, 787306
5.0 A Order no.: 777305, 787305
Contact material AgCuNi + 0.2 µm Au
External contact fuse protection (IK = 1 kA) to EN 60947-5-1
Blow-out fuse, quick
Safety contacts: 10 A Order no.: 777305, 787305
6 A Order no.: 777306, 787306
Auxiliary contacts: 10 A Order no.: 777305, 787305
6 A Order no.: 777306, 787306
Blow-out fuse, slow
Safety contacts: 4 A Order no.: 777306, 787306
6 A Order no.: 777305, 787305
Auxiliary contacts: 4 A Order no.: 777306, 787306
6 A Order no.: 777305, 787305
Circuit breaker 24 VAC/DC, characteristic B/C
Safety contacts: 4 A Order no.: 777306, 787306
6 A Order no.: 777305, 787305
Auxiliary contacts: 4 A Order no.: 777306, 787306
6 A Order no.: 777305, 787305
Max. overall cable resistance Rlmax
input circuits, reset circuits
single-channel at UB DC 30 Ohm Order no.: 777305, 787305
45 Ohm Order no.: 777306, 787306
single-channel at UB AC 100 Ohm Order no.: 777305, 787305
45 Ohm Order no.: 777306, 787306
dual-channel without detect. of shorts across contacts at UB DC 50 Ohm Order no.: 777305, 787305
80 Ohm Order no.: 777306, 787306
dual-channel without detect. of shorts across contacts at UB AC 100 Ohm Order no.: 777305, 787305
80 Ohm Order no.: 777306, 787306
dual-channel with detect. of shorts across contacts at UB DC 15 Ohm
dual-channel with detect. of shorts across contacts at UB AC 15 Ohm

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Safety-related characteristic data


PL in accordance with EN ISO 13849-1 PL e (Cat. 4)
Category in accordance with EN 954-1 Cat. 4
SIL CL in accordance with EN IEC 62061 SIL CL 3
PFH in accordance with EN IEC 62061 2.31E-09
SIL in accordance with IEC 61511 SIL 3
PFD in accordance with IEC 61511 2.03E-06
tM in years 20
Times
Switch-on delay
on monitored reset with rising edge typ. 30 ms
on monitored reset with rising edge max. 40 ms Order no.: 777306, 787306
50 ms Order no.: 777305, 787305
Delay-on de-energisation
with E-STOP typ. 10 ms Order no.: 777306, 787306
15 ms Order no.: 777305, 787305
with E-STOP max. 20 ms Order no.: 777306, 787306
30 ms Order no.: 777305, 787305
with power failure typ. 60 ms Order no.: 777305, 787305
with power failure max. 100 ms Order no.: 777305, 787305
with power failure typ. UB AC/DC: 24 V Order no.: 777306, 787306 180 ms Order no.: 777306, 787306
with power failure max. UB AC/DC: 24 V Order no.: 777306, 230 ms Order no.: 777306, 787306
787306
with power failure typ. UB AC : 240 V 1,100 ms Order no.: 777306, 787306
with power failure max. UB AC : 240 V 1500 ms Order no.: 777306, 787306
Recovery time at max. switching frequency 1/s
after E-STOP 50 ms
after power failure 200 ms Order no.: 777305, 787305
250 ms Order no.: 777306, 787306
after power failure on universal power supply 1500 ms Order no.: 777306, 787306
Waiting period with a monitored reset
with rising edge 250 ms Order no.: 777305, 787305
300 ms Order no.: 777306, 787306
Min. start pulse duration with a monitored reset
with rising edge 30 ms
Simultaneity, channel 1 and 2 ∞
Supply interruption before de-energisation 20 ms
Environmental data
EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4
Vibration to EN 60068-2-6
Frequency 10 - 55 Hz
Amplitude 0.35 mm
Climatic suitability EN 60068-2-78
Airgap creepage in accordance with EN 60947-1
Pollution degree 2
Overvoltage category III
Rated insulation voltage 250 V
Rated impulse withstand voltage 4.0 kV
Ambient temperature -10 - 55 °C
Storage temperature -40 - 85 °C
Protection type
Mounting (e.g. cabinet) IP54
Housing IP40
Terminals IP20
Mechanical data
Housing material
Housing PPO UL 94 V0
Front ABS UL 94 V0

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

-8
E-STOP relay, safety gate monitor

Up to PL e of EN ISO 13849-1
PNOZ X2.7P

Mechanical data
Cross section of external conductors with screw terminals
1 core flexible 0.25 - 2.50 mm² , 24 - 12 AWG Order no.: 777305, 777306
2 core, same cross section, flexible:
with crimp connectors, without insulating sleeve 0.25 - 1.00 mm² , 24 - 16 AWG Order no.: 777305, 777306
without crimp connectors or with TWIN crimp connectors 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 777305, 777306
Torque setting with screw terminals 0.50 Nm Order no.: 777305, 777306
Cross section of external conductors with spring-loaded termi- 0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 787305, 787306
nals: Flexible with/without crimp connectors
Spring-loaded terminals: Terminal points per connection 2 Order no.: 787305, 787306
Stripping length 8 mm Order no.: 787305, 787306
Dimensions
Height 101.0 mm Order no.: 787305, 787306
94.0 mm Order no.: 777305, 777306
Width 22.5 mm
Depth 121.0 mm
Weight 190 g Order no.: 777305, 787305
205 g Order no.: 787306
210 g Order no.: 777306
Technische Daten_Satz Normen

The standards current on 2009-04 apply.


][Dauerstrom_ACDC

Conventional thermal current

Number of contacts Ith (A) at UB DC Ith (A) at UB AC


1 6.00 A Order no.: 777306, 787306 6.00 A
8.00 A Order no.: 777305, 787305
2 6.00 A 4.00 A Order no.: 777305, 787305
6.00 A Order no.: 777306, 787306
3 4.50 A Order no.: 777306, 787306 3.50 A Order no.: 777305, 787305
5.00 A Order no.: 777305, 787305 4.50 A Order no.: 777306, 787306
Bestelldaten

Order reference

Type Features Terminals Order no.


PNOZ X2.7P C 24 VAC 24 VDC Spring-loaded terminals 787 305
PNOZ X2.7P 24 VAC 24 VDC Screw terminals 777 305
PNOZ X2.7P C 24 - 240 VAC 24 - 240 VDC Spring-loaded terminals 787 306
PNOZ X2.7P 24 - 240 VAC 24 - 240 VDC Screw terminals 777 306

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-331-2009-09
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

You might also like