Monitor Instructions Eltec
Monitor Instructions Eltec
Monitor Instructions Eltec
Main Screen
Icon explanation
No engine No Machine Saw Active Hydraulic Oil Temp.
Error Errors (FB only) Normal
Engine Minor Minor Machine Harvester Not Hydraulic Oil Temp.
Error Error Active (FH only) High
Engine Major Major Machine Harvester Active Hoods
Error Error (FH only) Closed
Normal Hydraulic Hydraulic Filter Hoods
Oil Level Normal Open
Clogged Air Low Hydraulic Oil Hydraulic Filter Water Temp.
Filter Lever Clogged Normal
Engine Intake DPF Normal Swing Water Temp.
Heater ON Operation Unlocked High
Cooling Fan DPF Manuel Regen. Swing Fuel Level Below
Normal Cycle Requested Locked 10%
Cooling Fan Regenaration Track Speed Fuel Level Above
Reverse Cycle Inhibit Activated Slow 10%
Engine Oil Manual Regen. Track Speed Auto Throttle
Pressure Normal Activated Medium Actived
Low Engine Oil Saw Not Activate Track Speed Auto Throttle
Pressure (FB only) High Deactivated
273
Speed Ajustments
Table of contents Table des matières
Operator Ajustments
Hold for 3
seconds to
Reset to default
settings.
P.S. Defaults
can be
modified with
Plus1 tool
Minimum current: This is the first current that will be sent to piloting coil when the
joystick is at beginning of stroke. The higher the current is set, the more aggressive the
function will be at begging of joystick stoke.
Example: If spool Opens at 190ma and current is set at 170, joystick will have to be moved
farther for function to beging moving. If current is set 210, as soon as joystick begins to
move spool will kick open.
Maximum current: This is the utmost current that will be sent out to piloting coil when
the joystick is at end of stroke. Lowering this current will limit speed of function and
raising current will speed up function, until spool is against spool limit screw.
Example: If spool is fully opened at 310ma and current is set to 290ma function will not be
at full possible speed when joystick is at end of stroke, but if current is set a 330 the last
part of joystick stroke will be wasted because at 310 spool is against limit screws.
Acceleration ramp: This is the time it will take for the current to go from Minimum to
Maximum when the joystick is fully stoked.
Example: If time is set to 50ms (milliseconds), and currents are set to 170ma for minimum
and 310ma for maximum, when joystick is suddenly moved to full stroke it will take 50ms
for current to go from 170ma to 310ma and 50ms for function spool to be fully open.
Deceleration ramp: This is the time it will take for the current to go from Maximum to
Minimum when the joystick is released.
Example: If time is set to 50ms, and currents are set to 170ma for minimum and 310ma for
maximum, when joystick is suddenly released it will take 50ms for current to go from
310ma to 170ma and 50ms for function spool to close.
275
Table of contents Table des matières
Progression: This setting will modify current output to EPC's in relation to joystick
displacement. For the same hydraulic response, joystick will need to be
pushed much futher in progression 1 that it will in progression 5.
Progression 1 Progression 2
Current Current
Out to Out to
EPC EPC
Progression 3 Progression 4
Current Current
Out to Out to
EPC EPC
Progression 5
Current
Out to
EPC
Joystick out
276
Table of contents Table des matières
% Speed
In this screen operator can quickly increase or decrease speed of each fonction.
To do so simply use the up & down arrows to scroll to the desired function and use the
left and right arrow to decrease and increase the percentage.
What this does is lower or raise the Maximum current sent out to piloting EPC's.
Example: If Maximum current for boom up is set to 320ma in operator ajustments and
% Speed of boom up is 80%, max current actualy sent out to EPC will be 80% of 320ma
which is 256ma.
These settings will also follow the operator selection. So if operator 1 ajusts all % speed
at 80% and operator 2 runs with all speeds at 90% when the operator is changed in the
main screen the % speed will change along with all operator settings.
These include: Hydraulic settings, % speed, joystick buttons, joystick mode and
attachment rotor direction.
277
Table of contents
Dealer Settings Table des matières
Fan Control
278
Table of contents Table des matières
Auto Idle Time: This will set the time for the engine to drop to low idle when Auto idle is active.
Head Type: This will change certain drawings and available data in the monitor and also certain
outputs from ELTEC controler. Available options are Buncher and Harvester.
Anti Stall Agg: There are 5 available levels. Factory setting is 3. This setting will change how much the
controler will let the engine RPM drop before destroking the main hydraulic pumps. At Level 1 pumps
will remain engaged longer and let the engine lug down lower before destroking the pumps. At level 5
anti-stall will destroke pumps much faster to always keep engine RPM at maximum.
Calibration Joystick : Rocker Pedal: This menu will enter calibration screen for joysticks and pedals and will
also allow deadband adjustment for these as well. ENGINE MUST BE SHUT DOWN TO CALIBRATE
Attachement Settings: This will enter adjustment screen for attachement. Here you can ajust flows and
time delays for different attachment functions.
Current final speed: This current will set output flow from attachment valve. Max flow
should be around 102GPM. Spool limiter might need ajustment to reach maximum flow.
Start time High current: This will set the time for which high start current will last.
High starting current: This current will be the first current sent to attachment valve.
This will make the attachment valve open faster to get a better reaction from attachment
Feed rollers delay the saw: This is a time delay between roller current and saw current
for attachment valve. When going from feed signal (P2C) to saw signal (P2A OR P2B),
current will go from P2C current to 0 for the amount of time set and back to saw current.
This setting allows attachment spool to close between roller and saw functions to prevent
overspeeding of the saw motors.
P.S. It is important to connect pump signals to corect pin to have the delays between functions
280
Table of contents Table des matières
Go to attachment pinout
configuration.
281
Table of contents Table des matières
CN3P01 CN3P05
CN3P02 CN3P06
CN3P03 CN3P07
CN3P04 CN3P08
The outputs on connector CN3 for the Attachment, can be configured in different ways.
C1P12, C2P01, C2P02, C2P03, C2P05 & C2P08 can be configured 3 ways:
Digital + Attachement valve*, PWM + Attachment valve* or PWM alone.
The third page of the attachment settings is for Pinout configuration for a Grapple rotate float and a tool cylinder float**
For the Grapple rotate float the signal can be output in 1 of 2 places:
OXO24-99 C2P04 --> Sol37 or OXO24-99 C1P06 --> CN3P07
For the Tool cylinder float the signal can also be output in 1 of 2 places:
OXO24-99 C2P09 --> Sol38 or OXO24-99 C1P07 --> CN3P08
* + Attachment valve means that the attachment valve (sol23) will be simultaniously activated
** An additional external valve needs to be added to create this function.
Table of contents
Dealer Settings Page 2 Table des matières
Adjustment pressure Levelling: Select this menu to perform pressure adjustments on tilt cylinders.
X Axis Right Joystick: This will turn On or Off the right hand joystick X axis input in the IXO
module. This will prevent the ELTEC system from running diagnostics on this circuits so the
circuit can be removed from the IXO controller and sent to the Harvester head control system.
Harvester Head J1939: This will Enable/Disable the CAN communication function between
ELTEC and the harvester
Boom Stop: This will bring you to the boom stop menu. From there you can adjust decel time and
maximum speed. This is an option that will slow and limit the speed of the boom up function past a
certain height. A proximity switch and wiring need to be added to use this function.