Water Tank Structures Drawings
Water Tank Structures Drawings
Water Tank Structures Drawings
500
[5] Hardcore to be hand packed and Compacted
to Engineer's satisfaction.
4200
4000
5000
5000
[b] Columns = 40mm
26T12-01-200T1 [c] Beams = 25mm
[d] Slabs = 20mm
500
site before commencing of any work
ISSUES
DATE TO APPLICATION TO
No. DATE BY
REVISIONS
DESCRIPTIONS GRP. LDR. C.S. ENG.
150
REFERENCE DRAWINGS
DESCRIPTIONS
600
GL GL GL
PROJECT TITLE
DRAWING TITLE
01
02 02 02 02 02 02 02 02 02 02
250
C1/Sfb
ENG. H. J. N. Nyaanga
LOW LEVEL WATER TANK SECTION X---X (Scale 1:25) CHIEF ENGINEER (STRUCTURAL)
NAME SIGN DATE
DESIGN/DRAWN K. T. Mutai
CHECKED BY: Eng. G. S. Otipa
MINISTRY OF TRANSPORT, INFRASTRUCTURE,
PUBLIC WORKS, HOUSING AND
URBAN DEVELOPMENT
STATE DEPARTMENT OF PUBLIC WORKS
STRUCTURAL DEPARTMENT
NOTES
[1] All Structural concrete to be class 20/20
2. The Contractor must confirm all dimensions on site [4] Damp proof course (DPC) to be laid under all
250 250
before commencing any work.
8 Nos. T-16 walls
500
3. All steel works to confirm to BS 5950
4. All welds shall be continous fillet weld and to [5] Hardcore to be hand packed and Compacted
BS 5135 and electrodes shall comply with BS 639 to Engineer's satisfaction.
T10 STIRRUPS @ 150mm c/c
5. All bolted connections shall be made with appropriate
SECTION B-B (Scale 1:25) washers under both the bolt head and nut. [6] All reinforcements Must be inspected by
6. All fabrication and connection details to be provided Structural Engineer before casting concrete.
by the steel fabricator for approval to the Project
25mm GROUT
25mm GROUT
Structural Engineer prior to commencement of fabrication. [7] Strip foundation to Structural Engineers specs
500 7. After fabrication of the steel work and all surfaces shall be
painted with two coats of red oxide primer. [8] This drawing to be read in conjunction with any
4Nos. H.D BOLTS 25mm Diameter 4Nos. H.D BOLTS 25mm Diameter 250 250
8. After transit and erection, all damaged paint work relevant Architectural, Civil, Structural or any other
x600mm Long @250mm c/c x600mm Long @250mm c/c
or coating shall be repaired to the Engineer's satisfaction. drawings
525 75
75
300
[9] Concrete cover to reinforcement steel to be as
G.L G.L G.L
600
600
follows:
525
Determine on Site
125 125 125 125 [d] Slabs = 20mm
2000
T10 STIRRUPS @ 150mm c/c T10 STIRRUPS @ 150mm c/c
[10] High Yield Ribbed Bars to KS:ISO 6935-2 are
denoted "T"
B B B B
[11] Mild steel reinforcement bars to BS 4449 are
denoted "R"
01 02 800
2000 [12] Any errors, discrepancies or omissions are to
02 02 02 02 02 02 02 be reported to the Engineer immediately for
SECTION C--C PLAN BRACINGS 2550 correction before work is undertaken
Scale 1:50
500
500
[13] Assumed bearing Capacity=80KN/M2
CODE MEMBER SIZE C C C C [16] All black cotton soil shall be removed during
HIGH LEVEL WATER TANK SECTION A---A (Scale 1:25). excavation of foundation.
M1 100x100x4mm SHS
BR1 50x50x4mm Angle [17] Minimum lap length for all reinforcement bars
shall be 50 x bar diameter
PB1 50x50x4mm Angle
HB2 50x50x4mm Angle
4100 BK1 50x50x4mm Angle
ISSUES
DATE TO APPLICATION TO
1050
500 500
4 Nos. H.D BOLTS 25mm 5450 No. REVISIONS
22T16-01-200B2/
22T12-02-200T2
500
REFERENCE DRAWINGS
775
775
DESCRIPTIONS
C C
125
125 125125
22T16-01-200B1/
1000
1000
CLIENT JOB No.
A 22T12-02-200T1 A
4100
4100
2000
1000
C C C C PROJECT TITLE
2000
5550
500 500
1000
500
500
DRAWING TITLE
1000
1050
1775
775
STR 01
150 150
225
FILE No.
5450 SCALE(S) FIGURED DIMENSIONS ONLY TO
1:50, 1:25, 1:20. BE TAKEN FROM THIS DRAWING