Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

TeSys Deca Contactors - LC1DT20M7

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Product datasheet

Specifications

TeSys D contactor - 4P(4 NO) -


AC-1 - <= 440 V 20 A - 220 V AC
50/60 Hz coil
LC1DT20M7

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range TeSys
TeSys Deca

Range of product TeSys Deca

Product or component type Contactor

Device short name LC1D

Contactor application Resistive load

Utilisation category AC-1

Poles description 4P

[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz


Power circuit: <= 300 V DC

[Ie] rated operational current 20 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

[Uc] control circuit voltage 220 V AC 50/60 Hz

Complementary
Compatibility code LC1D

Pole contact composition 4 NO

Contact compatibility M6

Protective cover With

[Ith] conventional free air 10 A (at 60 °C) for signalling circuit


thermal current 20 A (at 60 °C) for power circuit

Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
250 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand 30 A 40 °C - 10 min for power circuit


current 61 A 40 °C - 1 min for power circuit
105 A 40 °C - 10 s for power circuit
210 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1


25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit

Average impedance 2.5 mOhm - Ith 20 A 50 Hz for power circuit

Power dissipation per pole 1.56 W AC-1

Nov 10, 2023 1


[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1

Overvoltage category III

Pollution degree 3

[Uimp] rated impulse withstand 6 kV conforming to IEC 60947


voltage

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability 15 Mcycles

Control circuit type AC at 50/60 Hz

Coil technology Without built-in suppressor module

Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz


0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)


70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)


VA 7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W at 50/60 Hz

Operating time 4...19 ms opening


12...22 ms closing

Maximum operating rate 3600 cyc/h 60 °C

Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end

Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Auxiliary contact composition 1 NO + 1 NC

Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1


type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz

Minimum switching voltage 17 V for signalling circuit

Minimum switching current 5 mA for signalling circuit

Insulation resistance > 10 MOhm for signalling circuit

Non-overlap time 1.5 ms on de-energisation between NC and NO contact


1.5 ms on energisation between NC and NO contact

Mounting support Rail


Plate

Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

2
Nov 10, 2023
IEC 60335-1

Product certifications GOST


BV
UL
CCC
GL
CSA
RINA
LROS (Lloyds register of shipping)
DNV

IP degree of protection IP20 front face conforming to IEC 60529

Protective treatment TH conforming to IEC 60068-2-30

Climatic withstand conforming to IACS E10 exposure to damp heat


conforming to IEC 60947-1 Annex Q category D exposure to damp heat

Permissible ambient air -40…60 °C


temperature around the device 60…70 °C with derating

Operating altitude 0...3000 m

Fire resistance 850 °C conforming to IEC 60695-2-1

Flame retardance V1 conforming to UL 94

Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)


Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)

Height 85 mm

Width 45 mm

Depth 92 mm

Net weight 0.365 kg

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 5.700 cm

Package 1 Width 9.500 cm

Package 1 Length 12.000 cm

Package 1 Weight 391.000 g

Unit Type of Package 2 S02

Number of Units in Package 2 16

Package 2 Height 15.000 cm

Package 2 Width 30.000 cm

Package 2 Length 40.000 cm

Package 2 Weight 6.800 kg

Offer Sustainability
Sustainable offer status Green Premium product

REACh Regulation REACh Declaration

REACh free of SVHC Yes

EU RoHS Directive Compliant


EU RoHS Declaration

Toxic heavy metal free Yes

Mercury free Yes

China RoHS Regulation China RoHS declaration

Nov 10, 2023 3


Pro-active China RoHS declaration (out of China RoHS legal scope)

RoHS exemption information Yes

Environmental Disclosure Product Environmental Profile

Circularity Profile End of Life Information

WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

PVC free Yes

Contractual warranty
Warranty 12 months

Recommended replacement(s)

4
Nov 10, 2023

You might also like