Haz Station 780-001
Haz Station 780-001
Haz Station 780-001
42004-156D
GAI-TRONICS®
A HUBBELL COMPANY
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive
business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains
all intellectual property and other rights in or to the information contained herein, and such information may
only be used in connection with the operation of your GAI-Tronics product or system. This manual may not
be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
General Information
GAI-Tronics hazardous area Page/Party® handset stations are designed to provide safe and clear
communications in hazardous areas, even in high-noise situations. These models are NRTL certified for
use in the US and Canada for the following areas: Class I, Div. 1, Groups C and D; Class II, Div. 1,
Groups E, F, and G; and Class III, Div. 1.
Each of these models includes a front-panel push button for paging, a 6-foot PVC coil cord, a noise-
canceling microphone for reduced transmission of background noise, and sidetone circuitry to reduce
amplification of the user’s voice and background noise into their earpiece. An electrical safety barrier
mounted inside the housing creates an intrinsically-safe handset. Multi-party stations include a durable
rotary switch for party line selection. The weatherproof stations include a nonmetallic housing with a front
door. This installation manual covers the following models:
Model Description
This manual provides instructions for station placement and mounting. Refer to Pub. 42004-184, 42004-
238, or 42004-239, as applicable, for information detailing how to maintain the explosion-proof integrity
of the stations. The appropriate publication is packed with each station.
Installation
Whether installing an entire system or only an add-on station, consult the system layout diagrams at the end
of this manual. These figures, used in conjunction with the station installation information and the cable
layout guide, should provide all the information necessary to install the Page/Party® stations. These figures
do not show an explosion-proof station; however, the basic points of the system layout and design still
apply.
NOTE A separate power feed is recommended for Page/Party® stations in Div.1 areas. With a
separate power feed, the Page/Party® stations can be shut off for maintenance without disrupting the power
supply to the other equipment in the Div. 1 area.
Enclosure Placement
All GAI-Tronics Page/Party® units are wired in parallel. Good system layout design minimizes the cable
required for each installation. GAI-Tronics multi-conductor cable, designed especially for this application,
is recommended. The number, size, and color-coding of conductors are listed in the accompanying system
connection diagrams.
System layout and power cable length are important considerations when installing Page/Party® equipment.
The rules vary for different systems, but generally, the total power cable length should not exceed 1 mile
(5280 feet) for 115 V ac systems. The length of cable between the stations is not a factor; the total cable
length is the most important consideration.
Mounting
To maintain the explosion-proof integrity of these stations, all mounting hardware is located outside the
aluminum enclosure. The suggested mounting height for all station enclosures is 54 inches (137 mm) up to
the centerline of the enclosure.
Indoor Station: Mount the indoor unit using the two mounting straps on the rear of the enclosure. Refer to
Figure 1. Use the standard 3/8-inch bolts to secure the enclosure to the mounting surface. Secure the two
bottom bolts first, then the top bolts. The mounting strap design allows the station to be removed from its
mounting surface by removing only two of the bolts.
Outdoor Station: The outdoor model stations are shipped with a separate glass-reinforced polyester
enclosure with a front door. This enclosure has four 0.44-inch diameter mounting feet in the 4 corners and
is suitable for mounting to many types of surfaces. Refer to Figure 2.
Conduit Installation
Refer to Pub. 42004-184 (US), 42004-238 (Canada) 42004-239 (Canada), as applicable. These
publications detail how to maintain the integrity of the explosion-proof stations.
NOTE External conduits in Class I, Groups C and D areas must have gas seals not more
than 18 inches (457 mm) from the station enclosure. External conduits in Class II and Class III
areas must have seals if the conduit system is not dust-tight.
Wiring
After the station is mounted, use a 7/16-inch wrench to open the front cover to access the Termination
PCBA. Refer to Pub. 42004-184 (US), and 42004-238 (Canada) or 42004-239 (Canada), as applicable
for wiring details.
Feed the wiring through the conduit and into the enclosure. Follow the wire colors carefully—these colors
correspond to GAI-Tronics 60029 or 60038 Series cable. The wires must be spade-lugged and connected
carefully and completely to the terminal block. An improper termination may result in diminished station
performance.
Before closing the station cover, plug the power interconnect cable from the front of the enclosure into the
connector on the power supply card in the rear enclosure.
NOTE All the bolts must be installed to maintain the integrity of the explosion-proof
construction.
To disable the muting feature, remove jumper W6 located on the 10489-001 Termination PCBA.. The
chart below describes how the muting function operates when specific combinations of wire jumpers W3,
W4, W5, and W6 are installed on the Termination PCBA.
O X X X The AUX/PAGE inputs to the amplifier are muted during station page
(as shipped from GAI-Tronics).
O X X O The AUX/PAGE inputs to the amplifier are not muted during a station page.
O X O X Mute the PAGE input only during a station page.
X X O X The PAGE input is muted during a station page or by contact closure between
the Mute A and B inputs.
X O X X The PAGE/AUX inputs are muted during a station page or by contact closure
between the Mute A and B inputs.
X O O O The PAGE/AUX inputs are not muted. Isolated normally open relay contact
output between the Mute A and B terminals is closed during station pages.
X = Installed O = Not Installed.
Mutual Muting
Stations that are located closely together may require mutual muting of the page amplifiers. To set up
mutual muting between stations, connect the orange (spare) wire in the GAI-Tronics station cable to TB2-
11(A) on each of the Div. 1 stations that require muting. All the mutually muted stations are then muted
when any connected station is paging.
Note: Jumpers W4, W5, and W6 must be installed.
Mutual muting can be accomplished between the Div. 1 stations and Div. 2 enclosures using most
GAI-Tronics 600 or 700 Series enclosures by connecting the orange (spare) wire between TB2-11(A) on
the Div. 1 station and TB1-7 on the Div. 2 enclosure:
Div. 1 Stations
TB2-11(A) Div. 2 Enclosures (TB1-7)
Operation
GAI-Tronics offers two types of Page/Party® systems: Single party with one page line and one party line,
and multi-party with one page line and five party lines allowing up to five simultaneous two-way
conversations.
For single party systems, complete the following steps to make a page announcement:
1. Lift the handset from the cradle.
3. Speak directly into the microphone to broadcast your announcement over the loudspeakers.
For multi-party systems, complete the following steps to make a page announcement:
1. Lift the handset from the cradle. If party line conversation is desired, rotate the selector switch to an
unoccupied party line.
3. Speak directly into the microphone to broadcast your announcement over the loudspeakers.
With either type of system, the full duplex party line communication is not broadcast over the system
speakers. Other individuals can also pick up and join the conversation at any time. Always return the
handset to the cradle following a page or a party line conversation.
Maintenance
The following adjustments are accessible through the rear amplifier chassis using a small screwdriver. The
handset/speaker amplifier section must be completely removed from the enclosure to access these controls.
A silk-screen on the rear of the amplifier identifies the following controls.
• Microphone Gain: adjusts the gain level from the microphone signal to the page or party lines.
• Receiver Sidetone: adjusts the amount of signal transmitted from the microphone to the receiver. To
properly adjust the sidetone, blow into the handset microphone while turning the sidetone adjustment.
The sidetone is correctly set when the person blowing into the handset can barely hear themselves.
• Receiver Volume: adjusts the gain level from the party line to the receiver.
• Speaker Volume: adjusts the volume level of the speaker (if any) associated with this station.
Troubleshooting
The following table lists some hints to aid technicians in troubleshooting.
Problem Solution
Specifications
Power input ................................................... 90-140 V ac; 120 V ac nominal, 50-60 Hz; 0.5 amp maximum
Dimensions:
Indoor stations ............ 13.1 H × 7.9 W × 5.6 D (8.9 including handset) inches; (332 × 200 × 143 mm)
Outdoor stations ........................................... 14.6 H × 10.9 W × 10.5 D inches; (371 × 276 × 226 mm)
Temperature range ................................................................................ -22 °F to +158 °F (-30 °C to +70 °C)
Shipping weight ...............................................................Indoor: 27 lbs. (12.2 kg); outdoor: 35 lbs. (11.7 kg)
Handset
Material/finish.................................................................................................................................... Gray ABS
Microphone ................................................................................................ 10 ohms, noise-canceling, dynamic
Receiver............................................................................................................................... 150 ohms, dynamic
Cable ............................................................................... Retractile with sealed elbow, 6-foot extended length
Handset Amplifier
Output ............................................................................................................ 1.5 V nominal into 33-ohm load
Gain........................................................................................................................................ 55 dB, adjustable
Frequency response.................................................... 250-4000 Hz,+0/-3 dB ref @ 1 kHz (1.5 VRMS) output
Distortion ........................................................................................................ 1.5% maximum THD @ 1 kHz
Preset adjustments .....................................................Microphone gain, sidetone adjustment, receiver volume
Speaker Amplifier
Output ......................................................................... @ 120 V ac: 12 watt minimum into 8- or 16-ohm load
Voltage gain .......................................................................................................... 20 dB minimum, adjustable
Frequency response................................................................................. 250-4000 Hz; +0/-3 dB ref @ 1 kHz
Distortion ............................................................................................. 1% maximum THD @ 1 kHz/12 watts
Input impedance............................................................................................. 50,000 ohm, minimum @ 1 kHz
Controls, preset adjustments..................................................................................................... Speaker volume
Explosion-proof Enclosure
Material/finish........................................................................................................................... Aluminum alloy
Mounting..........................................................................Wall or column, four 3/8-inch slotted mounting feet
Connections.................................................................................... Internal screw-type barrier terminal blocks
Conduit entry ..................................Standard hole size top: ¾ NPT; standard size hole bottom 1½-inch NPT
Weatherproof Enclosure
Material/finish...........................................................................................................Glass-reinforced polyester
Mounting.................................................................................................................................... Wall or column
Environmental rating ....................................................................................................................... NEMA 4X
Approvals
NRTL certified for use in US and Canada ..................................................... Class I, Div. 1, Groups C and D
Class II, Div. 1, Groups E, F, and G
Class III, Div. 1
Replacement Parts
Services. Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,
shall be performed in accordance with the standard of care with which such services are normally
provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will,
for a period of one (1) year from the date of completion, re-perform such services at no cost to Buyer. Re-
performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-Tronics
warranty obligations with respect to services exceed 100% of the total cost of services provided
hereunder.
Warranty Periods. Every claim by Buyer alleging a defect in the goods and/or services provided
hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above. Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.
Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be
responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED
BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Return Policy
If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.
(Rev. 1/97)